• 제목/요약/키워드: PV/Thermal system

검색결과 85건 처리시간 0.025초

가혹조건에서의 태양전지모듈 내구성 평가를 통한 최적의 시험조건 제안 (Suggestion of Long-term Life Time Test for PV Module in Highly Stressed Conditions)

  • 김경수;강기환;유권종;윤순길
    • 한국태양에너지학회 논문집
    • /
    • 제30권5호
    • /
    • pp.63-68
    • /
    • 2010
  • To guarantee life time more than 20 years for manufacturer without stopping photovoltaic(PV) system, it is really important to test the module in realistic time and condition compared to outside weather. In here, we tested PV modules in highly stressed condition compared to IEC standards. In IEC 61215 and IEC 61646 standards, damp-heat, thermal cycle(TC200) and mechanical test are main test items for evaluating long-term durability of PV module in controlled temperature and humidity condition. So in this paper, we have lengthened the test time for TC200 and damp-heat test and increased the loading stress on surface of module. Through this test, we can get some clue of proper the method for measuring realistic life cycle of PV modules and suggested the minimum time for PV test method. The detail description is specified as the following paper.

GaN HEMT를 적용한 3kW급 계통연계 태양광 인버터의 방열 설계 및 개발 (Development of a 3 kW Grid-tied PV Inverter With GaN HEMT Considering Thermal Considerations)

  • 한석규;노용수;현병조;박준성;주동명
    • 전력전자학회논문지
    • /
    • 제26권5호
    • /
    • pp.325-333
    • /
    • 2021
  • A 3 kW grid-tied PV inverter with Gallium nitride high-electron mobility transistor (GaN HEMT) for domestic commercialization was developed using boost converter and full-bridge inverter with LCL filter topology. Recently, many GaN HEMTs are manufactured as surface mount packages because of their lower parasitic inductance characteristic than standard TO (transistor outline) packages. A surface mount packaged GaN HEMT releases heat through either top or bottom cooling method. IGOT60R070D1 is selected as a key power semiconductor because it has a top cooling method and fairly low thermal resistances from junction to ambient. Its characteristics allow the design of a 3 kW inverter without forced convection, thereby providing great advantages in terms of easy maintenance and high reliability. 1EDF5673K is selected as a gate driver because its driving current and negative voltage output characteristics are highly optimized for IGOT60R070D1. An LCL filter with passive damping resistor is applied to attenuate the switching frequency harmonics to the grid-tied operation. The designed LCL filter parameters are validated with PSIM simulation. A prototype of 3 kW PV inverter with GaN HEMT is constructed to verify the performance of the power conversion system. It achieved high power density of 614 W/L and peak power efficiency of 99% for the boost converter and inverter.

PV 모듈 내 바이패스 다이오드 손상에 의한 열적 전기적 특성 변화 분석 (Analysis on thermal & electrical characteristics variation of PV module with damaged bypass diodes)

  • 신우균;정태희;고석환;주영철;장효식;강기환
    • 한국태양에너지학회 논문집
    • /
    • 제35권4호
    • /
    • pp.67-75
    • /
    • 2015
  • PV module is conventionally connected in series with some solar cell to adjust the output of module. Some bypass diodes in module are installed to prevent module from hot spot and mismatch power loss. However, bypass diode in module exposed outdoor is easily damaged by surge voltage. In this paper, we study the thermal and electrical characteristics change of module with damaged bypass diode to easily find module with damaged bypass diode in photovoltaic system consisting of many modules. Firstly, the temperature change of bypass diode is measured according to forward and reverse bias current flowing through bypass diode. The maximum surface temperature of damaged bypass diode applied reverse bias is higher than that of normal bypass diode despite flowing equal current. Also, the output change of module with and without damaged bypass diode is observed. The output of module with damaged bypass diode is proportionally reduced by the total number of connected solar cells per one bypass diode. Lastly, the distribution temperature of module with damaged bypass diode is confirmed by IR camera. Temperature of all solar cells connected with damaged bypass diode rises and even hot spot of some solar cells is observed. We confirm that damaged bypass diodes in module lead to power drop of module, temperature rise of module and temperature rise of bypass diode. Those results are used to find module with a damaged bypass diode in system.

태양에너지 해수담수화시스템에의 적용을 위한 판형 해수담수기의 열성능에 관한 실험적 연구 (Experimental Study on Thermal Performance of Palte-type Fresh Water Generator for applying Solar Energy Desalination System)

  • 김정배;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.35-41
    • /
    • 2007
  • To demonstrate the desalination system, the demo-plant was scheduled to be installed. The system was planned to use solar thermal collector as heat source and PV as electricity source. For the design of the desalination demonstration system, firstly the solar thermal system would be well designed from the result between the supplied heat into the fresh water generator and the fresh water yield. The generator for demonstration system was chosen as the fresh water generator of the single stage and effect with plate-type heat exchanger using low pressure evaporation method. The test facility for the tests to reveal the relationship between the fresh water yield and the supplied heat flow rate was designed and manufactured. The maximum fresh water yield of two fresh water generators applied in this study was designed as 1.5 Ton/day. The parameters relating with the performance of fresh water generator are known as sea water inlet temperature, hot water inlet temperature, and hot water flow rate. Through the experiments, this study firstly showed detail operation characteristics of the generator and designed the solar thermal system for the demonstration system.

태양광 시스템용 단상 및 3-레벨 부스트 컨버터의 효율 및 전력밀도 비교 분석 (Comparative Analysis of Efficiency and Power Density of Single-Phase and 3-Level Boost Converters for PV System)

  • 김철민;김종수
    • 전력전자학회논문지
    • /
    • 제25권2호
    • /
    • pp.127-132
    • /
    • 2020
  • In this study, single-phase and three-level boost converters applied to the photovoltaic system were compared and analyzed in terms of efficiency and power density according to the input voltage and load conditions. For accurate analysis of efficiency, the losses in each device of the single-phase and three-level boost converters were derived using mathematical equations and simulations by using the PSIM thermal module. Then, the losses were compared with the efficiency confirmed through the actual experiments. Results confirmed that the efficiency and power density can be improved by applying the three-level boost converter to the system according to the selection of the switching frequency.

Utility scale solar power development in Nepal

  • Adhikari, Rashmi
    • 한국태양광발전학회지
    • /
    • 제6권1호
    • /
    • pp.86-91
    • /
    • 2020
  • Nepal is among the richest in terms of water resource availability and it is one of the most important natural resources of the country. Currently, 72% of the population is electrified through the national grid system. The power generation mix into the grid is hydro dominated with minor shares generated from solar and thermal (accounts for less than 1%). To achieve sustainable development in the power sector it is essential to diversify power generation mix into the grid. Knowing the facts, the government has a plan to achieve a 5-10% share of power generation from solar and mix it into the grid system. Solar is the second most abundant, prominent and free source of renewable in the context of Nepal. This study mainly focuses on the grid-connected solar system, its importance, present status, government efforts, and its need. It is based on the review of literature, news published in national newspaper online news and international organization's report.

경제성분석 프로그램을 이용한 도심형 마이크로그리드 최적 설계 (Optimal Design of Urban MICROGRID using Economical Analysis Program)

  • 유승덕;임성우;임유석;황성욱;이학주
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.69-72
    • /
    • 2022
  • This paper actually investigates the load on major large-scale buildings in the downtown area, examines the economic feasibility of installing PV and ESS in a microgrid target building, and evaluates whether an electric vehicle capable of V2G through two buildings is effective as an economical analysis program (HOMER) was analyzed using. It is economical to install a mixture of ESS rather than using the whole PV, and it is shown that if there is an electric vehicle using the V2G function of EV, there is an economic effect to replace the PV. So that Incentives and policies are needed to replace a large area of PV and utilize the existing parking lot to lead EV as a resource of the microgrid. Currently, P2X technology that stores power as ESS or converts it to other energy to control when surplus renewable energy occurs in large-capacity solar power plants and wind farms, etc. This is being applied, and efforts are being made to maintain the stability of the system through the management of surplus power, such as replacing thermal energy through a heat pump. Due to the increase in electric vehicles, which were recognized only as a means of transportation, technologies for using electric vehicles are developing. Accordingly, existing gas stations do not only supply traditional chemical fuels, but electricity, and super stations that also produce electricity have appeared. Super Station is a new concept power plant that can produce and store electricity using solar power, ESS, V2G, and P2G. To take advantage of this, research on an urban microgrid that forms an independent system by tying a large building and several buildings together and supplies power through a super station around the microgrid is in full swing.

결정질 실리콘 태양광시스템의 물 발자국 산정에 대한 연구 (Analysis on the Water Footprint of Crystalline Silicon PV System)

  • 나원철;김영환;김경남;이관영
    • 청정기술
    • /
    • 제20권4호
    • /
    • pp.449-456
    • /
    • 2014
  • 기후변화로 인한 국지적인 이상가뭄 빈발 및 물수지 관련 불확실성 증가 등으로 각국에서는 사용가능한 담수량 확보, 즉 물안보 문제가 크게 대두되고 있다. 사용가능한 담수량 중 상당부분이 전력을 생산하는 발전 분야에도 사용되기 때문에 그 중요성이 점차 증대하고 있다. 신재생에너지원인 태양광발전은 설비제조, 설치 및 운전의 전 과정(life cycle)에서 수자원을 소비하지만 전통적인 에너지원인 화력발전이나 원자력발전에 비하면 상대적으로 수자원을 적게 사용한다는 장점이 있다. 본 연구에서는 태양광시스템의 원료채취부터 운영발전까지 물 사용량을 알아보기 위해 전 과정의 물 발자국을 측정하여 그 결과를 분석했다. 물 발자국 산정결과 태양광시스템의 전체 물 발자국은 $0.989m^3/MWh$이며, 폴리실리콘과 태양전지 공정에서 물 발자국이 높게 나타났다. 폴리실리콘 공정은 에너지 다소비 공정이기 때문에 냉각수 사용량이 많았고 태양전지 공정에서는 고효율 결정질 실리콘 세척을 위한 탈 이온수(deionized water) 사용량이 많았기 때문에 물 발자국이 높은 것으로 보인다. 태양광발전은 기존 에너지원보다 물 사용량이 적은 발전원임을 확인할 수 있었으며, 에너지 분야의 물 사용량을 절감할 수 있는 가치를 가지고 있음을 알 수 있다. 향후 에너지정책 결정에 있어서 신재생에너지의 부가적인 가치로서 물 발자국 개념의 도입이 중요하다.

다기능 솔라윈도우의 열성능 연구 (The Study of Thermal Performance on Solar Window)

  • 조일식;김장회;양윤섭;김병수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.65.2-65.2
    • /
    • 2010
  • The aim of this study was to analysis the Heating/cooling performance of Solar Window built in apartments. The solar window is the idea to integrate daylight as a third form of solar energy into a PV/Solar Collector system and allows more control due to the possibility to close the reflectors. However, there can be a conflict between the desire for on one hand daylight and view and on the other hand optimal energy conversion for the PV/Solar Collector system. The process of this study is as follows: 1) The Solar Window system is designed through the investigation of previous paper and work. 2)The simulation program(ESP-r, Therm5.0, Window6.0) was used in Heating/cooling performance analysis. The reference model of simulation was made up to analysis Heating/cooling performance on Solar Window. 3)Selected reference model(Floors:15, Area of Unit:$148.5m^2$) for heating energy analysis, Energy performance simulation with various variants, such as U-value of Solar Window system according to its position and angle. Consequently, When Solar Window system is equipped with balcony window of Apartment, Annual heating and cooling energy of reference model was cut down about 5%~11%.

  • PDF

수치 계산을 통한 다목적 BIPV 시스템의 운전방법에 관한 연구 (A Study on the Operation Methods of Multipurpose BIPV System by Numerical Analysis)

  • 김의종;김헌중;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제26권1호
    • /
    • pp.49-55
    • /
    • 2006
  • The Multipurpose BIPV System(MBIPVS) was evaluated as an effective passive system through analyzing the thermal performance and the efficiency of PV power generation in the previous papers. To achieve the performance better, the operation method should be determined by considering physical conditions in each occasion. Thus, we cheesed the reference operation methods in each season set by the overview of the meteorological data for last 6 years, In-choen, and compared them with the various alternatives that we had made up with for improving thermal performance. The results from adopting various alternatives on MBIPVS showed that the appropriate operational model would be effective to the energy savings ; we could reduce the total loads 1,051.0[kWh] in summer and 108.9[kWh] in winter.