Exergy Analysis of On/Off Controlled Heat Pump

  • Jang, Ki-Tae;Nam, Kwan-Woo;Jeong, Sang-Kwon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제7권
    • /
    • pp.22-32
    • /
    • 1999
  • A multi-type heat pump controls the mass flow rate of the working fluid to cope with variable heat loads when it is under dynamic load condition. This paper describes the exergy analysis associated with the unsteady response of a heat pump. First, a basic heat pump cycle is examined at a steady state to show the general trends of exergy variations in each process of the cycle. Entropy generation issue for the heat exchangers is discussed to optimize the heat pump cycle. Secondly, the performance of the inverter-driven heat pump is compared to that of the conventional one when the heat load is variable. Thirdly, the exergy destruction rate of the heat pump with On/Off operation is calculated by simulating the thermodynamic states of the working fluid in the condenser and the evaporator. The inefficiency of On/Off operation during the transient period is quantitatively described by the exergy analysis.

  • PDF

유압펌프 회전속도 제어방식 유압제어시스템의 특성 비교 분석 (Comparative Characteristic Analysis of a Hydraulic Control System Using a Speed Controlled Hydraulic Pump)

  • 정헌술;정승욱
    • 유공압시스템학회논문집
    • /
    • 제7권3호
    • /
    • pp.13-19
    • /
    • 2010
  • Hydraulic systems are widely used as a power transfer and/or power control system due to its flexibility, controllability, accuracy and high power density. Valve controlled and/or pump capacity controlled systems are normally adopted as a control device, but nowadays pump speed controlled systems are emerging as a new energy-efficient hydraulic control system. In this paper the pump speed controlled system for the cylinder position control of a counter balance circuit is investigated by simulation study and position control experiments were carried out. As a result, the possibility and efficiency of the pump speed controlled system were verified.

  • PDF

사판식 피스톤 펌프-관로계에서의 맥동류 해석 (Analysis of Pulsating Flow in a Swash Plate Type Piston Pump and Transmission Line)

  • 최영학;이일영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.45-49
    • /
    • 2000
  • Vibration and noise problem in a hydraulic system became one of very important factors in evaluating the performance of a hydraulic system. It is known that vibration and noise in a hydraulic system is directly related to flow pulsation in the hydraulic pump in the system. This study investigated a modeling and simulation technique for pulsating flow in a swash plate type axial piston pump. The key design factors of the pump related to flow pulsation phenomenon of the pump are the physical parameters for notches on the valve plate of the pump. By the numerical analysis, effects of the physical parameters of the notch on the flow pulsation was elucidated.

  • PDF

오비터 진공펌프 성능해석 (Performance Analysis of Orbiter Vacuum Pump)

  • 심재휘;김현진
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.287-290
    • /
    • 2006
  • Orbiter mechanism has been applied to vacuum pump design for small oxygen generator where low vacuum of about 200mmHg is required. Performance of the designed vacuum pump has been numerically investigated: calculated volumetric and adiabatic efficiencies were 69.7% and 83.9%, respectively for leakage clearance of $10{\mu}m$. Total efficiency of the orbiter vacuum pump was 77.5%. At the shaft speed of 1700 rpm suction displacement volume of 6.3cc provided discharge flow at the rate of 2.3 liter/min with power consumption of 10.1Watt. Torque variation of the orbiter pump was only about 20% of that of diaphragm pump.

  • PDF

Control of Pump Performance with Attaching Flaps on Blade Trailing Edges

  • Kanemori, Yuji;Pan, Ying Kang
    • International Journal of Fluid Machinery and Systems
    • /
    • 제1권1호
    • /
    • pp.109-120
    • /
    • 2008
  • An innovative method of changing a centrifugal low specific speed pump performance and pressure fluctuation by applying outlet flaps to impeller exit has been investigated. The outlet blade edge section corresponds to the trailing edge of wing on the circular-cascade, which dominates the pump performance and pressure fluctuation. Computational fluid dynamics (CFD) analysis of the entire impeller and volute casing and an experimental investigation are conducted. The pressure fluctuation and the vibration of the shaft are measured simultaneously. Kurtosis is applied as a dimensionless parameter with which the unevenness of velocity distribution at impeller outlet is indicated. The influence of the flaps on the pressure fluctuation is explained by the kurtosis. This paper presents a theoretical method of predicting the pump performance related to the attachment of a flap at impeller outlet.

실험계수를 이용한 원심 펌프의 설계와 해석 (Design and Analysis of Centrifugal Pump using Experimental Factor)

  • 임효남;김진영;양창조;이영호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.434-440
    • /
    • 2000
  • This study is focused on the performance prediction and design of the centrifugal pump with optimum shape. Design and analysis of centrifugal pump rely on experience of designer due to many fluid mechanical and geometrical variables. In this study, a design method was developed with experimental factors and analysed the method by comparition with 2nd-order vortex panel method. Impeller is the most important component affecting the performance of the centrifugal pump. The predicted total head for three cases, of which designs were determined by this method, agrees well with a particular commercial pump. This study shows that satisfactory performance of an optimal pump shape can be obtained through the automatic design routine.

  • PDF

LPLi 연료펌프의 맥놀이 소음 저감 연구 (Reduction of Beating noise at LPLi pump)

  • 강태식;심재기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계 학술대회논문집(수송기계편)
    • /
    • pp.161-165
    • /
    • 2005
  • Until now LPG car has drived used to mixer and vaporizer. So LPG car always has problems back fire and when in the winter. LPG Car's Fuel consumption is rather than gasoline. But LPLi Fuel pump located in the fuel tank is directly injection in the engine. So Fuel consumption is better than LPG mixer system and result to reduced exhaust gas. In this paper to reduction of beating noise of LPLi(liquid phase LPG Injection) fuel pump. General speaking we know, beating noise is occur to near frequency each of pump. So we Modification of RPM through chang of amature turn number and area of dimension of the pump's body.

  • PDF

해수 열원 및 폐열 이용 고성능 열펌프 시스템 모사 (Simulation for High Efficient Heat Pump System using Seawater Heat Source and Exhaust Energy)

  • 최광일;오종택;오후규
    • 설비공학논문집
    • /
    • 제15권1호
    • /
    • pp.59-66
    • /
    • 2003
  • The purpose of this study is to analyze the characteristics (COP) of the heat pump system for various operating conditions with the use of seawater heat source and exhaust energy. To accomplish the goal, first of all, the computer simulation for heat pump system is carried out. The heat pump system model is made of a waste heat recovery system and a vapor compression refrigeration system, and the working fluid is R-22. The model calculated the change of COP with the variation of temperature and flow rate. The COP and the plate heat exchanger (PHE) area of the heat pump system are considered moderately high in the condensation temperature of $25^{\circ}^C$ and the evaporation temperature of $2^{\circ}^C$ in indoor culture system. The simulation results will be used effectively for the design and the performance prediction of heat pump system using unused energy in a land base aquaculture system.

하천수 열원 이용 열펌프 시스템의 LCC 분석 (LCC Analysis of a Heat Pump System Using River Water)

  • 한상수;박차식;김용찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1424-1428
    • /
    • 2009
  • The performance of a heat pump using river water as a heat source was compared with that of a conventional air-conditioner for cooling and a boiler system for heating. The heat pump system using river water considered the 1-stage cycle for cooling and the 2-stage cycle for heating. The COPs of the river water source heat pump were $0.5{\sim}1.1$ higher than those of the conventional system in the cooling season. The LCC of the river water source heat pump system was lower 13.5% and 32.4% than that of the conventional system I and II. In addition, when the initial cost ratios of the river water source heat pump system to the conventional system I and II were less than 1.2 and 1.4, respectively, an acceptable payback was found to be less than 5 years.

  • PDF

절자 비례 밸브를 갖는 펌프의 퍼지-동력제어기 설계 (Design of Fuzzy-Power Controller for a Pump with Electric Proportional Valve)

  • 전순용
    • 제어로봇시스템학회논문지
    • /
    • 제4권4호
    • /
    • pp.441-447
    • /
    • 1998
  • Motivated by a recent work, a fuzzy-power-controller(FPC) is designed for the relieving-horsepower control of output variable pump with electrical proportional valve and actually implemented on the industrial excavator. In order to calculate the output power of pump with input of FPC, a linear discrete time model of load system to pump is obtained and the result is applied to control the engine-pump coupled system by software without pressure and flow sensor. The FPC controls the engine and pump coupled system by relieving horsepower control according to the change of load and the running conditions in relieving horsepower control are selected by fuzzy inference engine. A case study is peformed through the construction of the control device and installation on the excavator. It shows that the relieving-horsepower control system with the FPC, as suggested in this paper, is superior to the conventional PID controllers. And also, the excavator, with the FPC, shows that the power-loss of the coupled system is reduced and the running speed of the hydraulic actuator is enhanced.

  • PDF