• Title/Summary/Keyword: PUMP

Search Result 6,404, Processing Time 0.027 seconds

Temperature analysis of extra vessel electromagnetic pump cooling for a Micro nuclear reactor with an electric power of 20 MW

  • Tae Uk Kang;Hee Reyoung Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.275-282
    • /
    • 2024
  • Lead bismuth eutectic (LBE) is used as coolant for MicroURANUS, a small marine nuclear power plant, and this coolant is transported in the plant by an electromagnetic pump. Given the considerable heat generated by the electromagnetic pump, the cooling of the pump is essential. This study compared air cooling and water-cooling methods and found that the maximum temperatures during air and water cooling were 640 K and 372 K, respectively. These findings were utilized to design an electromagnetic pump with water-cooling. The maximum temperature of the pump was lower than the boiling point of water; thus, the pump did not require a separate pressurization. Consequently, the resistance problem of the coil and the deformation problem of the material caused by generated heat can be solved through water-cooling.

Early and Midterm Outcome of Redo Coronary Artery Bypass Grafting: On-Pump versus Off-Pump Bypass

  • Shin, Yu Rim;Lee, Sak;Joo, Hyun Chel;Youn, Young-Nam;Kim, Jong Gun;Yoo, Kyung-Jong
    • Journal of Chest Surgery
    • /
    • v.47 no.3
    • /
    • pp.225-232
    • /
    • 2014
  • Background: Redo coronary artery bypass grafting (CABG) is still associated with increased morbidity and mortality as compared to the first-time operation. Further, the application of the off-pump technique to redo CABG is limited due to technical difficulties. The aim of this retrospective study was to analyze early and midterm results after redo CABG and compare the outcome of redo on-pump and off-pump CABG. Methods: From June 1996 to October 2011, elective redo CABG was performed in 32 patients. Mean age was 64.8 years (on pump 64.3 years vs. off pump 65.5 years; p=0.658), and 21 patients were male. Among these patients, 14 (43.8%) underwent on-pump CABG, and 18 (56.2%) underwent off-pump CABG. Results: Internal thoracic artery was used in 22 patients (68.8%), and total arterial revascularization was achieved in 17 patients (53.1%). The average number of distal anastomoses was 2.13, and the rate of incomplete revascularization was 43.8%. The rate of total arterial revascularization was higher in the off-pump group (14.3% vs. 83.3%, p<0.001), and the use of saphenous vein graft was more in the on-pump group (78.6% vs. 16.7%, p<0.001). Overall hospital mortality was 3.1% (n=1) and was comparable in both groups (on pump 7.1% vs. off pump 0%; p=0.249). Postoperative complications occurred in 9 patients (64.2%), and the rate of complications was high in the on-pump group without statistical significance (64.2% vs. 33.3%, p=0.082). The mean follow-up duration was 5.4 years, and overall survival at 10 years was $86.0%{\pm}10.5%$. There was no significant difference in the 10-year survival rate between the two groups (79.6% vs. 100%, p=0.225). Conclusion: Redo CABG can be safely performed with acceptable mortality. Redo off-pump coronary artery bypass is feasible with low mortality and morbidity, comparable target vessel bypass grafting, and long-term survival. The off-pump technique might be considered a safe option for redo CABG in high-risk patients.

Risk Factors of On-Pump Conversion during Off-Pump Coronary Artery Bypass Graft

  • Yoon, Sung Sil;Bang, Jung Hee;Jeong, Sang Seok;Jeong, Jae Hwa;Woo, Jong Soo
    • Journal of Chest Surgery
    • /
    • v.50 no.5
    • /
    • pp.355-362
    • /
    • 2017
  • Background: Off-pump coronary artery bypass grafting (OPCABG) procedures can avoid the complications of an on-pump bypass. However, some cases unexpectedly require conversion to cardiopulmonary bypass during OPCABG. The risk factors associated with a sudden need for cardiopulmonary bypass were analyzed. Methods: This retrospective study included 283 subjects scheduled for OPCABG from 2001 to 2010. These were divided into an OPCABG group and an on-pump conversion group. Preoperative, operative, and postoperative variables were compared between the 2 groups. Results: Of the 283 patients scheduled for OPCABG, 47 (16%) were switched to on-pump coronary artery bypass grafting (CABG). The mortality of the both the OPCABG and on-pump conversion groups was not significantly different. The major risk factors for conversion to on-pump CABG were congestive heart failure (CHF) (odds ratio [OR], 3.5; p=0.029), ejection fraction (EF) <35% (OR, 4.4; p=0.012), and preoperative beta-blocker (BB) administration (OR, 0.3; p=0.007). The use of intraoperative (p=0.007) and postoperative (p=0.021) inotropics was significantly higher in the conversion group. The amount of postoperative drainage (p<0.001) and transfusion (p<0.001) also was significantly higher in the conversion group. There were no significant differences in stroke or cardiovascular complications between the groups over the course of short-term and long-term follow-up. Conclusion: Patients who undergo OPCABG and have CHF or a lower EF (<35%) are more likely to undergo on-pump conversion, while preoperative BB administration could help prevent conversions from OPCABG to on-pump CABG.

Efficacy evaluation of syringe pump developed for continuous drug infusion

  • Jung, Bongsu;Seo, Kwang-Suk;Kwon, Suk Jin;Lee, Kiyoung;Hong, Suyong;Seo, Hyounsoon;Kim, Gi-Young;Park, Geun-Mook;Jeong, Juhee;Seo, Soowon
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.16 no.4
    • /
    • pp.303-307
    • /
    • 2016
  • Background: In dental intravenous sedation, continuous intravenous infusion of a low-dose drug requires an infusion pump such as a syringe pump. To develop a new syringe pump for clinical use, the functions of the pump must meet certain international standards. Various safety and efficacy tests must be performed on the syringe pump, as stipulated by these standards, and an approval must be received from the approving agency based on such test results. Methods: The authors of the present study developed a novel syringe pump and performed efficacy evaluation by testing its infusion speed at 1 and 25 ml/h, and infusion performance testing at 2 and 24 h. Moreover, performance evaluation was conducted by comparing the novel pump to an existing pump with the infusion speed varied from 1 to 5 ml/h. Results: In the efficacy testing on the newly developed syringe pump, infusion with the infusion speed initially set to 1 ml/h resulted in infusion speeds of 1.00 and 0.99 ml/h in the 2- and 24-h assessment, respectively. Changing the infusion speed setting to 25 ml/h resulted in an infusion speed of 25.09 and 23.92 ml/h in the 2- and 24-h assessment, respectively. These results show no significant differences when compared with other commercially available pumps. Conclusions: The efficacy testing of the newly developed syringe pump showed the accuracy to be within tolerance. Based on these findings, we believe that the newly developed syringe pump is suitable for clinical use.

Design of Remote Infusion Pump Monitoring System Using Wireless Network and RFID Technology (무선 네트워크와 RFID 기술을 이용한 원격 Infusion Pump 모니터링 시스템 설계)

  • Lee, Seo-Joon;Lee, Tae-Ro
    • Journal of Digital Convergence
    • /
    • v.11 no.6
    • /
    • pp.159-167
    • /
    • 2013
  • Development of infusion pumps enabled injecting medical substances continuously and automatically to patients in hospitals. However, in cases when patients encountered emergent situations when moving to other areas, no clear measures were taken. The problem is that even the lightest error in injecting medical substances could be critical to the patient. That is why we proposes a remote infusion monitoring system using wireless network and RFID technology in this paper. When a problem occurs in the infusion pump, the medical personnel are informed of their patients' emergent situation and location information via wireless network so not only can they swiftly and accurately provide medical services but also can prevent safety accidents due to infusion pumps.

Effects of the Lift Valve Opening Area on Water Hammer Pump Performance and Flow Behavior in the Valve Chamber

  • Saito, Sumio;Dejima, Keita;Takahashi, Masaaki;Hijikata, Gaku;Iwamura, Takuya
    • International Journal of Fluid Machinery and Systems
    • /
    • v.5 no.3
    • /
    • pp.109-116
    • /
    • 2012
  • Water hammer pumps can effectively use the water hammer phenomenon for water pumping. They are capable of providing an effective fluid transport method in regions without a well-developed social infrastructure. The results of experiments examining the effect of the geometric form of water hammer pumps by considering their major dimensions have been reported. However, these conventional studies have not fully evaluated pump performance in terms of pump head and flow rate, common measures of pump performance. The authors have focused on the effects on the pump performance of various geometric form factors in water hammer pumps. The previous study examined how the hydrodynamic characteristics was affected by the inner diameter ratio of the drive and lift pipes and the angle of the drive pipe, basic form factors of water hammer pumps. The previous papers also showed that the behavior of water hammer pump operation could be divided into four characteristic phases. The behavior of temporal changes in valve chamber and air chamber pressures according to the air volume in the air chamber located downstream of the lift valve was also clarified in connection with changes in water hammer pump performance. In addition, the effects on water hammer pump performance of the length of the spring attached to the drain valve and the drain pipe angle, form factors around the drain valve, were examined experimentally. This study focuses on the form of the lift valve, a major component of water hammer pumps, and examines the effects of the size of the lift valve opening area on water hammer pump performance. It also clarifies the behavior of flow in the valve chamber during water hammer pump operation.

On-Pump versus Off-pump Myocardial Revascularization in Patients with Renal Insufficiency: Early and Mid-term Results

  • Kim, Hwan-Wook;Lee, Jae-Won;Je, Hyung-Gon;Choi, Soo-Hwan;Jo, Keon-Hyon;Song, Hyun
    • Journal of Chest Surgery
    • /
    • v.44 no.5
    • /
    • pp.323-331
    • /
    • 2011
  • Background: Myocardial revascularization in patients with renal insufficiency is challenging to the cardiac surgeon, irrespective of utilizing extracorporeal circulation. This study aimed to compare the number of bypass grafts and the mid-term results and to evaluate independent survival predictors in patients with renal insufficiency undergoing on-pump or off-pump myocardial revascularization. Materials and Methods: We retrospectively analyzed the data of 103 patients with renal insufficiency, who had isolated myocardial revascularization between January 1999 and January 2009. The patients were divided into two groups, the on-pump group and the off-pump group. Results: The off-pump group received a significantly greater number of distal arterial grafts than the on-pump group. However, the mean number of total grafts, the degree of complete revascularization, and survival rate of the patients were not significantly different between the two groups. Multivariate analysis showed the independent predictors for reduced mid-term survival were the number of total grafts and postoperative periodic renal replacement therapy. Off-pump myocardial revascularization does not decrease the number of bypass grafts or influence on the mid-term results for patients with renal insufficiency, compared to on-pump myocardial revascularization. Conclusion: Myocardial revascularization with a large number of total grafts has a beneficial effect on survival in patients with renal insufficiency, irrespective of utilizing extracorporeal bypass.

A Study on the Development of a Infusion Pump based on an Active Muscle Pump (능동형 근육펌프 구조의 수액 주입 펌프 개발에 관한 연구)

  • Lee, Jeong-Whan;Lee, Sang-Yeob;Lee, Jung-Eun;Ahn, Ihn-Seok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.443-449
    • /
    • 2022
  • In this study, in order to improve the disadvantages of the environmental error of the infusion set that performs infusion therapy in the existing clinical practice and to maximize the user's convenience by miniaturizing the existing infusion pump system, the structure of the muscle pump of the human vein was imitated. As a double check valve method, a method for preventing the backflow of fluid and discharging a constant fluid in one direction by external pressure was proposed. The proposed bio-mimic muscle pump uses a check valve that controls the flow of fluid in one direction and a silicone tube with elasticity, and a chamber is constructed. A peristaltic pump for applying intermittent pressure to the tube chamber was constructed using a multi-cam structure roller. In order to verify the performance of the proposed pump, optimization was performed while changing the number of multi-cam rollers and adjusting the speed of the roller driving motor, and the reproducibility of the instantaneous discharge amount and the continuous discharge amount of the pump was compared and tested. The performance of the muscle pump proposed in this study was verified through experiments that it can inject up to 1L of fluid within 12 hours, and that it is possible to inject the fluid with an accuracy of ±0.1ml. Real-time monitoring of the fluid injection volume through the bio-mimic muscle pump proposed in this study not only increases the convenience of the administrator, but also provides a precise fluid administration environment to more patients at a low cost, and additionally applies bubble detection and occlusion detection technology If so, it is believed that a safer medical environment can be provided to patients.

Analytical Evaluation of Rotor Dynamic Characteristic of Roots Type Vacuum Pump (루츠타입 진공펌프 동특성의 해석적 평가)

  • Lee, Jong-Myeong;Kim, Yong-Hwi;Ha, Jeong-Min;Gu, Dong-Sik;Choi, Byeong-Keun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.12
    • /
    • pp.1112-1119
    • /
    • 2011
  • The goal of this study is the stability evaluation of a vacuum pump through modal test and rotor dynamics. Roots type vacuum pump, which is a dry vacuum pump, is necessary for the manufacturing process of the semiconductor and the display. Eigenvalue was solved by the finite-element method(FEM) using 2D and 3D models, then the modal test result was compared with the FEM result. According to the comparison, the analysis result using the 2D was more accurate than the 3D model. Therefore, rotor dynamics was performed by the 2D model. Campbell diagram and root-locus maps, which were calculated by complex-eigenvalue analysis, were used to evaluate the stability of the rotors of the vacuum pump. And displacement solved by unbalance response analysis was compared with the minimum clearance between two rotors of the vacuum pump. Thus, the vacuum pump is assumed operated under steady state through the evaluation of the rotor dynamics.

Development of the Automation System for a fish Pump(I) -Adjustable Speed Control of a Fish Pump Using a Simplified PWM Inverter- (피쉬펌프의 자동화 시스템 개발(I) -간이화 PWM 인버터를 이용한 피쉬펌프의 가변속 제어-)

  • 정석권
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.3
    • /
    • pp.328-334
    • /
    • 1999
  • A fish pump makes very important roles in an automation system of an aquaculture farm, thus it has been used widely in order to transfer fishes from one place to the other place automatically. In spite of its significant roles, the efforts for developing performance and promoting efficiency of the fish pump are not sufficient yet. In this paper, a method which makes the fish pump automation system is suggested. Automation of the fish pump can be accomplished by using variable voltage and variable frequency inverter system including induction motors. Especially, very simple logic to generate Pulse width Modulation(PWM) wave to control induction motor efficiently and three steps speed control method to regulate liquid quantity of the fish pump simply are suggested. Owing to the simplifies speed control and PWM wave generation technique, a cheaper microprocessor, 80C196KC, than a digital signal Processor(DSP) can be used to operate control algorithm in induction motor systems for real time control Also, a new idea of remote control for the simplifies novel inverter system by Programmable logic Controller(PLC) without special output unit, digital to analog converter(D/A), is suggested in this paper. Consequently the function of reliability, availability and serviceability of the fish pump system are developed. It will be expected to contribute expanding of application of the fish pump in aquaculture farms because the system can reduce energy consumption and some difficulties according to manual operation prominently.

  • PDF