• Title/Summary/Keyword: PULSE

Search Result 10,423, Processing Time 0.038 seconds

Power Spectrum of Jittered Random Pulse Train (불규칙 Pulse 신호의 전력 Spectrum)

  • 최양희;김재경
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.17 no.1
    • /
    • pp.10-13
    • /
    • 1980
  • The power spectrum of jittered pulse train is derived for the independent stationary pulse sequence with a stationary Gaussian phase jitter. For the unipolar pulse train signal, it is shown that as the phase jitter increases, the continuous Part of the power spectrum increases chile the discrete part decreases.

  • PDF

Development of a High Voltage Pulse Power Supply with Battery Source (밧데리 전원을 이용한 고압 펄스 전원 장치 개발)

  • 강유리
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.95-97
    • /
    • 2000
  • With the increasing demands for clean environment development of air cleaning systems has been received increasing attention. Pulse power systems are widely used for air cleaning in the industrial applications. High voltage pulse power supply affects the performance of the overall environmental system. In this study high voltage micro pulse power supply for removing NOx in diesel engines is developed. The ratings of the pulse voltage is 20kV. The pulse width is 10usec and max. pulse repetition ratio is 1kHz.

  • PDF

Pulse Multiplication of 6-Pulse Thyristor Converter with Simple Auxiliary Circuit (간단한 보조회로 추가에 의한 6-펄스 싸이리스터 컨버터의 다펄스화)

  • 오준용
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.294-298
    • /
    • 2000
  • A new pulse multiplication technique based on 6-pulse thyristor converters is proposed in this paper. With the proposed technique 12-pulse 18-pulse and 24-pulse operations have been obtained both on the input current and on the output voltage. A control strategy over the whole range of phase angle is provided along with sophisticated input current and output voltage analysis. Experimental results from a laboratory prototype verify the proposed theory.

  • PDF

Influence of first sustain pulse width on equilibrium sustain current in AC-PDP with ramp reset pulse

  • 김성수
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.200-200
    • /
    • 2000
  • AC-PDP의 구동은 인가되는 Pulse의 파형에 의하여 결정된다. 이번 실험은 AC-PDP의 Subfield 파형중 Sustain 부분 첫 번째 Pulse의 폭(Width)에 변화를 주어 다음 Suatain Pulse 기간동안의 전기 광학적 특성을 구속 카메라와 전류의 변화를 통하여 측정하였으며 Sustain Pulse의 Rising Time을 변화 시켜 방전특성을 측정하였다. 이를 통하여 적합한 Sustain 구간의 초기조건을 예측하였으며, 적합한 Sustain Pulse를 찾아가는 실험 방법을 찾고자 하였다.

  • PDF

Power and Collection Characteristics of Superimposed Pulse Electrostatic Precipitator (중첩펄스 전기집진기의 전력 및 집진특성)

  • Seo, Gyeong-Won;Lee, Chang-Sin;Lee, Jeong-Seok;Chae, Jae-U
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.3
    • /
    • pp.177-185
    • /
    • 2000
  • In this study, the characteristics of various electricity and high resistivity ash collection were measured at superimposed nanosecond pulse energization. The pulse was generated through the hydrogen thyratron. Superimposed pulse was nanosecond duration pulse that had fast pulse rising time 100[ns], short pulse width 500∼850[ns] and pulse fall time 400∼750[ns]. The results of this study are summarized as followings; Frist, compared with the DC ESP(electrostatic precipitator), superimposed pulse ESP could induce higher peak voltage, and had the about 30[%] reduction of ESP collection area and 50∼80[%] reduction of power consumption. showing the same efficiency. Second, enhancement factor H had 1.9∼3.6 with the increase of migration velocity.

  • PDF

A study on three bu(部) nine hu(候) pulse diagnosis(三部九候診) (고대(古代) 경맥진단법(經脈診斷法) 중 삼부구후진(三部九候診)에 관(關)한 연구(硏究))

  • Hur, Keum-Bum;Yoon, Jong-Hwa;Kim, Kap-Sung
    • Journal of Acupuncture Research
    • /
    • v.19 no.3
    • /
    • pp.1-13
    • /
    • 2002
  • Objective : The purpose of this study is a investigation about alteration and meaning of three bu(部) nine hu(候) pulse diagnosis(三部九候診) Methods : We refered to prescriptions from anciant to modern such as Naekyung(內經) and Nankyung(難經) Results and Conclusion : 1. Three bu(部) nine hu(候) pulse diagnosis(三部九候診) is more important pulse diagnosis method than any other method in Naekyung(內經) 2. Three bu(部) nine hu(候) pulse diagnosis(三部九候診) is a simplized twlve meridian pulse diagnosis method based on Samjae philsophy(三才思想) 3. Three bu(部) nine hu(候) pulse diagnosis(三部九候診) is useful for venesection theraphy based on Naekyung(內經) and it is demolished with the progress of Chon-gu pulse diagnosis method(寸口脈診法)

  • PDF

A Study on the Arterial Pulse Wave Measuring System of an Oral Cavity (구강 내부 맥파 계측을 위한 센서 시스템 연구)

  • Kim, Kyung-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.6 no.4
    • /
    • pp.43-47
    • /
    • 2007
  • In this paper, we propose a novel sensor system for measuring the arterial pulse in an oral cavity. In order to measure pulse wave in oral cavity, the proposed system is designed with reflection type arterial wave sensor, not by using transmission type arterial pulse wave sensor. Driving circuit through pulse current is designed for solving self-heating problem of LED. The effectiveness of the proposed sensor system is compared with pulse wave between pulse wave of oral cavity and other body parts as well as with characteristic measurements. The experiment shows that the proposed sensor system is adaptive to capturing consecutive and meaningful biometric signals through the variation of pulse wave changes in oral cavity when exercising. The study result expects to design and develop mobile sensors which could be adapted to healthcare devices.

  • PDF

Computerized pulse diagnosis system (컴퓨터 맥진시스템)

  • Lee, Ho-Jae;Huh, Woong
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.4
    • /
    • pp.81-90
    • /
    • 1996
  • In this paper, we implemented a computerized pulse diagnosis system for the developement of pulse diagnosis algorithms and the generalization of the pulse diagnosis. The system consists of the hardware and software. The hardware detects pulse waves and inputs the waves into the computer system, while the software not only manages and analyzes the input pulse wave data but also privides the database. In order to clinically test the developed pulse diagnosis system, we applied the carotid-radial pulse diagnosis algorithm to the system. As the results, it is found that the genralizatio of the pulse diagnosis is possible.

  • PDF

Mechanical and Tribological Properties of Pulse and Direct Current Electrodeposited Ni-TiO2 Nano Composite Coatings

  • Gyawali, Gobinda;Woo, Dong-Jin;Lee, Soo-Wohn
    • Journal of the Korean institute of surface engineering
    • /
    • v.43 no.6
    • /
    • pp.283-288
    • /
    • 2010
  • Ni-$TiO_2$ nano composite coatings were fabricated using pulse current electrodeposition technique at 100 Hz pulse frequency with a constant 50% pulse duty cycles and reference was taken with respect to the direct current (dc) electrodeposition. The properties of the composite coatings were investigated by using SEM, XRD, Wear test and Vicker's microhardness test. Pulse electrodeposited composite has exhibited enhancement of (111), (220), and (311) diffraction lines with an attenuation of (200) line. The results demonstrated that the microhardness of composite coatings under pulse condition was significantly improved than that of pure nickel coating as well as dc electrodeposited Ni-$TiO_2$ composite coatings. Wear tracks have shown the less plastic deformation in pulse plated composite. Coefficient of friction was also found to be lower in pulse plated composite coatings as compared to dc plated composite coatings.

New Configuration of 36-pulse Voltage Source Converter Using Pulse-Interleaving Auxiliary Circuit (펄스다중화 보조회로를 이용한 새로운 구조의 36-펄스 전압원 컨버터)

  • Jon Young-Soo;Baek Seung-Taek;Han Byung-Moon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.5
    • /
    • pp.238-244
    • /
    • 2005
  • This paper proposes a new configuration of 36-pulse voltage source converter which consists of two 6-pulse bridges and a pulse-interleaving auxiliary circuit. The system topology of proposed converter was derived to increase the pulse number of converter output voltage without increasing the number of 6-pulse bridges. The gate pulse generation was analyzed using the theoretical approach of multi-pulse switching converter, The operational feasibility of proposed system was verified by computer simulations with PSCAD/EMTDC software and experimental works with 2kVA hardware prototype. The proposed converter can be widely used for the uninterruptible power supply, the power quality compensator, and the distributed power generation, such as solar and fuel cell power system.