• Title/Summary/Keyword: PULSE

Search Result 10,452, Processing Time 0.033 seconds

Comparative Evaluation of Concrete Compressive Strength According to the Type of Apartment Building Finishing Materials Using Nondestructive Testing (비파괴검사법을 이용한 공동주택 마감재 종류에 따른 콘크리트 압축강도 비교평가)

  • Seong-Uk Hong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.1
    • /
    • pp.32-38
    • /
    • 2024
  • In the case of apartment building, it is difficult to conduct non-destructive testing due to the actual presence of people and the dust and noise generated during the core test, so inspections are performed each time in the common area and underground parking lot, and the tests are conducted on the finishing material rather than on the concrete surface due to low-cost orders. As the process progresses, poor inspection is inevitable. In addition, the proposed formulas for strength estimation have large fluctuations depending on the differences in test conditions and environments, and even if they show the same measured value, the deviation between each proposed formula is large, making it difficult to accurately estimate strength, making it difficult to use. Accordingly, we would like to select finishing materials mainly used in apartment complexes and compare and evaluate the compressive strength of concrete according to the type of finishing material by using non-destructive testing methods directly on the finishing materials without removing the finishing materials. The reliability evaluation results of the estimated compressive strength of concrete using the ultrasonic velocity method according to the type of finishing material are as follows. The error rate between the estimated compressive strength and compressive strength derived through the ultrasonic velocity method shows a wide range of variation, ranging from 21.83% to 58.89%. The effect of the presence or absence of finishing materials on the estimated compressive strength was found to be insignificant. Accordingly, it is necessary to select more types of finishing materials and study ultrasonic velocity methods according to the presence or absence of finishing materials, and to study estimation techniques that can increase reliability.

Association of Airflow Limitation and COPD Composite Index with Peripheral Oxygen Saturation in Patients with Chronic Obstructive Pulmonary Disease (만성폐쇄성폐질환자에서 기류제한 및 COPD 복합지수와 말초산소포화도의 연관성)

  • Jong Seong Lee;Jae Hoon Shin;Jin Ee Baek;Hyerim Son;Byung-soon Choi
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.1
    • /
    • pp.57-66
    • /
    • 2024
  • Objective: Chronic obstructive pulmonary disease (COPD) is characterized by progressive airflow obstruction that is only partly reversible, inflammation in the airways, and systemic effects. This study aimed to investigate the association between low peripheral oxygen saturation levels (SpO2), and composite indices predicting death in male patients with (COPD). Method: A total of 140 participants with post-bronchodilator FEV1/FVC ratio less than 0.7 were included. Three composite indices (ADO, DOSE, BODEx) were calculated using six variables such as age (A), airflow obstruction (O), body mass index (B), dyspnea (D), exacerbation history (E or Ex), and smoking status (S). Severity of airflow limitation was classified according to Global Initiative for Obstructive Lung Disease (GOLD) guidelines. SpO2 was measured by pulse oximetry, and anemia and iron deficiency were assessed based on blood hemoglobin levels and serum markers such as ferritin, transferrin saturation, or soluble transferrin receptor. Results: Participants with low SpO2 (<95%) showed significantly lower levels of %FEV1 predicted (p=0.020) and %FEV1/FVC ratio (p=0.002) compared to those with normal SpO2 levels. The mMRC dyspnea scale (p<0.001) and GOLD grade (p=0.002) showed a significant increase in the low SpO2 group. Receiver Operating Characteristic analysis revealed higher area under the curve for %FEV1 (p=0.020), %FEV1/FVC(p=0.002), mMRC dyspnea scale (p=0.001), GOLD grade (p=0.010), ADO (p=0.004), DOSE (p=0.002), and BODEx (p=0.011) in the low SpO2 group. Conclusion: These results suggest that low SpO2 levels are related to increased airflow limitation and the composite indices of COPD.

Assessment of the Application Status of Transcutaneous/Percutaneous Vagus Nerve Stimulation for Musculoskeletal Pain: A Scoping Review for Utilization in Korean Medicine and Subsequent Research (경피적 미주 신경 자극술의 근골격계 통증에 대한 적용 현황 파악: 한의학적 활용 및 후속 연구를 위한 Scoping Review)

  • Gun Hee Bae;Jeong Hoon Ahn;Dong Jin Jang;Jeong Hee Noh;Jae Kwon Shin;Eun Seok Jin;Sun Kyu Yeom;Seung Ju Oh
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.34 no.1
    • /
    • pp.65-81
    • /
    • 2024
  • Objectives This study aimed to understand the general research trends, applicated disease, and methodology of transcutaneous/percutaneous vagus nerve stimulation, contemplating its clinical use in traditional Korean medicine and future research directions. Methods A scoping review was conducted following Arksey and O'Malley Framework Stage and adhering to the PRISMA extension for scoping reviews: checklist and explanation. Papers published until October 30, 2023, were investigated across 10 databases (PubMed, Embase, Scopus, Web of Science, China National Knowledge Infrastructure, Oriental Medicine Advanced Searching Integrated System, Korean Studies Information Service System, KMbase, Science ON, Research Information Sharing Service. The search terms used were 'Transcutaneous/Percutaneous vagus nerve stimulation'. Results Since 2021, the application of transcutaneous/percutaneous vagus nerve stimulation for musculoskeletal symptoms has been actively researched, predominantly in Asia (37%), Europe (37%), and North America (21%). All 19 papers were part of clinical studies. Chronic pain was noted that most applied disease, it also was found to potentially aid in acute post-surgical pain relief. Major assessment tools include not only simple pain metrics but also pain perception, vagal nerve tension, quality of life, and inflammatory markers. Most procedures were carried out through the ear, which offers a favorable site for therapeutic stimulation without notable side effects. And parameter analysis, frequencies typically ranged around 25 Hz to 30 Hz, while pulse widths were commonly set at 250 ㎲ or 300 ㎲. Conclusions Transcutaneous/percutaneous vagus nerve stimulation is easily accessible through acupuncture in Korean medicine. Therefore, if future studies establish parameters and clinical significance, it could be utilized as a therapeutic modality.

Identification of an effective and safe bolus dose and lockout time for patient-controlled sedation (PCS) using dexmedetomidine in dental treatments: a randomized clinical trial

  • Seung-Hyun Rhee;Young-Seok Kweon;Dong-Ok Won;Seong-Whan Lee;Kwang-Suk Seo
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.24 no.1
    • /
    • pp.19-35
    • /
    • 2024
  • Background: This study investigated a safe and effective bolus dose and lockout time for patient-controlled sedation (PCS) with dexmedetomidine for dental treatments. The depth of sedation, vital signs, and patient satisfaction were investigated to demonstrate safety. Methods: Thirty patients requiring dental scaling were enrolled and randomly divided into three groups based on bolus doses and lockout times: group 1 (low dose group, bolus dose 0.05 ㎍/kg, 1-minute lockout time), group 2 (middle dose group, 0.1 ㎍/kg, 1-minute), and group 3 (high dose group, 0.2 ㎍/kg, 3-minute) (n = 10 each). ECG, pulse, oxygen saturation, blood pressure, end-tidal CO2, respiratory rate, and bispectral index scores (BIS) were measured and recorded. The study was conducted in two stages: the first involved sedation without dental treatment and the second included sedation with dental scaling. Patients were instructed to press the drug demand button every 10 s, and the process of falling asleep and waking up was repeated 1-5 times. In the second stage, during dental scaling, patients were instructed to press the drug demand button. Loss of responsiveness (LOR) was defined as failure to respond to auditory stimuli six times, determining sleep onset. Patient and dentist satisfaction were assessed before and after experimentation. Results: Thirty patients (22 males) participated in the study. Scaling was performed in 29 patients after excluding one who experienced dizziness during the first stage. The average number of drug administrations until first LOR was significantly lower in group 3 (2.8 times) than groups 1 and 2 (8.0 and 6.5 times, respectively). The time taken to reach the LOR showed no difference between groups. During the second stage, the average time required to reach the LOR during scaling was 583.4 seconds. The effect site concentrations (Ce) was significantly lower in group 1 than groups 2 and 3. In the participant survey on PCS, 8/10 in group 3 reported partial memory loss, whereas 17/20 in groups 1 and 2 recalled the procedure fully or partially. Conclusion: PCS with dexmedetomidine can provide a rapid onset of sedation, safe vital sign management, and minimal side effects, thus facilitating smooth dental sedation.

Development of Radar System for Laser Tracking System (레이저 추적 시스템을 위한 레이더 시스템 개발)

  • Ki-Pyoung Sung;Hyung-Chul Lim;Man-Soo Choi;Sung-Yeol Yu
    • Journal of Space Technology and Applications
    • /
    • v.4 no.1
    • /
    • pp.1-11
    • /
    • 2024
  • Korea Astronomy and Space Science Institute (KASI) developed an satellite laser ranging (SLR) system for tracking space objects using ultra-pulsed lasers. For the safe operation of SLR system, aircraft surveillance radar system (ASRS) was developed to prevent human damage from high power laser transmitted from the SLR system. The ASRS consists of the radar hardware subsystem (RHS) and main control subsystem (MCS), in order to detect flying objects in the direction of laser propagation and then stop immediately the laser transmission. The RHS transmits the radio frequency (RF) pulse signals and receives the returned signals, while the MCS analyzes the characteristics of received signals and distinguishes the existence of flying objects. If the flying objects are determined to be existed, the MCS sends the command signal to the laser controller in SLR system to pause the laser firing. In this study, we address the interface and operational scenarios of ASRS, including the design of RHS and MCS. It was demonstrated in the aircraft experiments that the ASRS could detect an aircraft and then stop transmitting high power laser successfully.

Photosynthetic Characteristics of Benthic Microalgae Measured by HPLC and Diving Pulse Amplitude Modulated (PAM) Fluorometry on the Nakdong River Estuary of the Korean Peninsula (HPLC 및 Diving-PAM을 이용한 낙동강 하구 저서미세조류의 광합성 특성)

  • Jeong Bae Kim;Mi Hee Chung;Jung-Im Park
    • Korean Journal of Ecology and Environment
    • /
    • v.57 no.2
    • /
    • pp.61-74
    • /
    • 2024
  • Daemadeung, located in the estuary of the Nakdong River, is formed by sand dunes and possesses well-developed intertidal flats. This study aimed to investigate the habitat of benthic microalgae, photosynthetic pigments, and photosynthetic efficiency in the intertidal flats of Daemadeung from January to December 2011. The inorganic nitrogen content in the sediment pore water was primarily composed of ammonium, while nitrate + nitrite was dominant in the upper layer water. The concentration of chlorophyll a and fucoxanthin in the sediment surface was significantly higher than the mean of all the sediment layer. The average Fv/Fm of benthic microalgae during the entire survey period was 0.52±0.03, with the highest value (0.61±0.08) observed in February. The rETRmax showed a seasonal trend, being high from spring to early autumn (April to October) and low from winter to early spring (January to March, November, December), with the highest value (153.05±2.30 µmol electrons m-2 s-1) in July and the lowest (38.49±5.17 µmol electrons m-2 s-1) in January. The average Fv/Fm of diurnal microalgae was 0.48±0.03, with the highest value (0.61±0.08) observed at noon. The rETRmax showed a highest peak at noon (54.24±11.35 µmol electrons m-2 s-1) and reached its lowest point at 16:00 (26.17±4.75 µmol electrons m-2 s-1). These findings suggest that the productivity of benthic microalgae varies significantly depending on the survey time and sediment depth. Therefore, to quantify the productivity of benthic microalgae using Diving-PAM, surveys should be conducted based on tidal conditions, and simultaneous pigment analysis of sediment layers should also be performed.

CNN Model-based Arrhythmia Classification using Image-typed ECG Data (이미지 타입의 ECG 데이터를 사용한 CNN 모델 기반 부정맥 분류)

  • Yeon-Suk Bang;Myung-Soo Jang;Yousik Hong;Sang-Suk Lee;Jun-Sang Yu;Woo-Beom Lee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.24 no.4
    • /
    • pp.205-212
    • /
    • 2023
  • Among cardiac diseases, arrhythmias can lead to serious complications such as stroke, heart attack, and heart failure if left untreated, so continuous and accurate ECG monitoring is crucial for clinical care. However, the accurate interpretation of electrocardiogram (ECG) data is entirely dependent on medical doctors, which requires additional time and cost. Therefore, this paper proposes an arrhythmia recognition module for the purpose of developing a medical platform through the analysis of abnormal pulse waveforms based on Lifelogs. The proposed method is to convert ECG data into image format instead of time series data, apply visual pattern recognition technology, and then detect arrhythmia using CNN model. In order to validate the arrhythmia classification of the CNN model by image type conversion of ECG data proposed in this paper, the MIT-BIH arrhythmia dataset was used, and the result showed an accuracy of 97%.

Review of laser-plasma physics research and applications in Korea

  • W. Bang;B. I. Cho;M. H. Cho;M. S. Cho;M. Chung;M. S. Hur;G. Kang;K. Kang;T. Kang;C. Kim;H. N. Kim;J. Kim;K.B. Kim;K. N. Kim;M. Kim;M. S. Kim;M. Kumar;H. Lee;H. W. Lee;K. Lee;I. Nam;S. H. Park;V. Phung;W. J. Ryu;S. Y. Shin;H. S. Song;J. Song;J. Won;H. Suk
    • Journal of the Korean Physical Society
    • /
    • v.80
    • /
    • pp.698-716
    • /
    • 2022
  • Laser plasmas can be produced when high-power laser beams are focused in matter. A focused laser beam of TW(terawatt)-level high power has an extremely strong electric field, so neutral atoms are immediately ionized by the laser electric field, leading to a laser-produced plasma. The laser plasma can be produced by small table-top TW lasers based on the CPA (chirped-pulse amplification) technique, and now they are rather easily available even in university laboratories. In Korea, there are several CPA-based TW (or even petawatt) lasers in a few institutions, and they have been used for diverse laser plasma physics research and applications, including the laser acceleration for electrons and ions, high-power THz (tera-hertz) generation, advanced light sources, high-energy-density plasmas, plasma optics, etc. This paper reviews some of the laser plasma physics research and applications that have been performed in several universities and research institutes.

Effect of a 12-Week Combined Exercise Program on Cardiovascular Function and Electrocardiogram Based ST Segment, QRS in Obese Middle-Aged Women (12주 복합운동 프로그램이 비만 중년여성의 심혈관계 기능과 심전도 기반의 ST 분절, QRS군에 미치는 영향)

  • Jeong-Hee Yun;Ki-Wook Jo;Chang-Hwan Kim
    • Journal of the Korean Applied Science and Technology
    • /
    • v.41 no.3
    • /
    • pp.705-720
    • /
    • 2024
  • This study randomly assigned 24 middle-aged women to determine the effect of a 12-week combined exercise program on cardiovascular function and electrocardiogram-based ST segment and QRS in obese middle-aged women. Analysis of the results was conducted to verify differences within groups and between periods and groups. In terms of cardiovascular function, myocardial oxygen consumption showed a significant decrease in the experimental group during the resting phase and the highest intensity phase during exercise, and an interaction between group and period at rest was also observed. The heart rate recovery rate showed a significant decrease in the experimental group at 2 minutes of recovery, while in the control group, on the contrary, a significant increase was observed. The experimental group showed a significant decrease in systolic blood pressure, and an interaction between group and period was also observed. There was no change in diastolic blood pressure in both the experimental and control groups, and there was a statistically significant decrease in pulse pressure only in the experimental group at the 3-minute recovery stage. In the case of the electrocardiogram, the QRS height in the experimental group showed a significant increase in most cases at rest and at 3, 6, and 9 minutes during the recovery period, while there was no significant difference in the QRS period in both the experimental and control groups, and the ST segment height was significantly increased at rest in the experimental group. appeared to have increased. Therefore, summarizing the results of this study, it is believed that the 12-week combined exercise program has a positive effect in improving cardiovascular function, ventricular contractility in electrocardiograms, and myocardial ischemia in obese middle-aged women.

Quasi-breath-hold (QBH) Biofeedback in Gated 3D Thoracic MRI: Feasibility Study (게이트 흉부자기 공명 영상법과 함께 사용할 수 있는 의사호흡정지(QBH) 바이오 피드백)

  • Kim, Taeho;Pooley, Robert;Lee, Danny;Keall, Paul;Lee, Rena;Kim, Siyong
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.72-78
    • /
    • 2014
  • The aim of the study is to test a hypothesis that quasi-breath-hold (QBH) biofeedback improves the residual respiratory motion management in gated 3D thoracic MR imaging, reducing respiratory motion artifacts with insignificant acquisition time alteration. To test the hypothesis five healthy human subjects underwent two gated MR imaging studies based on a T2 weighted SPACE MR pulse sequence using a respiratory navigator of a 3T Siemens MRI: one under free breathing and the other under QBH biofeedback breathing. The QBH biofeedback system utilized the external marker position on the abdomen obtained with an RPM system (Real-time Position Management, Varian) to audio-visually guide a human subject for 2s breath-hold at 90% exhalation position in each respiratory cycle. The improvement in the upper liver breath-hold motion reproducibility within the gating window using the QBH biofeedback system has been assessed for a group of volunteers. We assessed the residual respiratory motion management within the gating window and respiratory motion artifacts in 3D thoracic MRI both with/without QBH biofeedback. In addition, the RMSE (root mean square error) of abdominal displacement has been investigated. The QBH biofeedback reduced the residual upper liver motion within the gating window during MR acquisitions (~6 minutes) compared to that for free breathing, resulting in the reduction of respiratory motion artifacts in lung and liver of gated 3D thoracic MR images. The abdominal motion reduction in the gated window was consistent with the residual motion reduction of the diaphragm with QBH biofeedback. Consequently, average RMSE (root mean square error) of abdominal displacement obtained from the RPM has been also reduced from 2.0 mm of free breathing to 0.7 mm of QBH biofeedback breathing over the entire cycle (67% reduction, p-value=0.02) and from 1.7 mm of free breathing to 0.7 mm of QBH biofeedback breathing in the gated window (58% reduction, p-value=0.14). The average baseline drift obtained using a linear fit was reduced from 5.5 mm/min with free breathing to 0.6 mm/min (89% reduction, p-value=0.017) with QBH biofeedback. The study demonstrated that the QBH biofeedback improved the upper liver breath-hold motion reproducibility during the gated 3D thoracic MR imaging. This system can provide clinically applicable motion management of the internal anatomy for gated medical imaging as well as gated radiotherapy.