• Title/Summary/Keyword: PUF4

Search Result 48, Processing Time 0.022 seconds

The Effects of Kevlar Pulp on Polyurethane Foam for Cryogenic Temperature (극저온용 폴리우레탄 폼에 미치는 케블라 펄프의 영향)

  • Oh, Jong-Ho;Bae, Jin-Ho;Lee, Jae-Myung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.55 no.6
    • /
    • pp.514-520
    • /
    • 2018
  • Polyurethane foam has excellent mechanical strength and insulation performance, and has been adopted as an insulation material for $-163^{\circ}C$ liquefied natural gas carrier. In this study, Kevlar Polyurethane Foams(K-PUF) were synthesized by adding Kevlar pulp with excellent mechanical strength for the purpose of improving the performance of existing polyurethane foam. Since polyurethane foam has mechanical performance depending on the proportions of Kevlar pulp added, the mechanical strength of the K-PUF with ratios of fiber0.2wt.%, 0.4wt.%, 0.6wt.%, 0.8wt.% and 1.0wt.%) was evaluated. The compression tests were performed on the 4 different temperatures($20^{\circ}C$, $-50^{\circ}C$, $-110^{\circ}C$ and $-163^{\circ}C$) in consideration of the environmental characteristics as a cryogenic insulation used in LNG carrier. Besides, the effects of the fiber addition on polyurethane foam with closed cell structure were evaluated in a phenomenological approach through SEM analysis. All the results were compared to Neat-polyurethane foam. As a results, 0.8wt.% K-PUF showed the improved mechanical strength, and the addition of Kevlar pulp in a certain ratio improves the mechanical performance by enhancing the compression resistance.

On the Leakage Safety Analysis of Membrane LNG Storage Tank With Thermal Resistance Effects (열저항 효과를 고려한 멤브레인식 LNG 저장탱크의 누설 안전성에 관한 연구)

  • Kim C.K.;Cho S.H.;Suh H.S.;Hong S.H.;Lee S.R.;Kim Y.G.;Kwon B.K.
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.4 s.25
    • /
    • pp.1-7
    • /
    • 2004
  • In this paper, the FE analysis has been presented for the leakage safety of the membrane LNG storage tank based on the thermal resistance effects between the insulation panel and prestressed concrete structure. The FEM calculated results show that the leakage safety of plywood and polyurethane materials does not guarantee any more due to a strength failure of the insulation structure. But the PC structure of outer tank may delay leaked LNG of 10 days even though the inner tank and insulation structure are simultaneously failed. This means that the membrane LNG storage tank may be safe because of the stiffness of the outer tank.

  • PDF

Estimation of PCBs Concentrations in Ambient Air Using Pine Needles as a Passive Air Sampler (PAS) (소나무잎을 Passive Air Sampler(PAS)로 이용하여 대기 중 PCBs 농도 추정)

  • Chun, Man-Young
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.4
    • /
    • pp.360-368
    • /
    • 2012
  • Objective: This study was carried out to use pine needles as a passive air sampler (PAS) of atmospheric Polychlorinated Biphenyls (PCBs). Methods: PCB concentrations in ambient air ($C_a$, ng/$m^3$) and deposited on pine needles ($C_p$, ng/g dry) were analyzed simultaneously from June 1 to December 31. Air samples were taken using a low volume PUF active air sampler and the overall average air volume was about 900-1,000 $m^3$. Pine needles were collected at the end of August and December near the air sampler. Results: $C_a$ were higher at higher air temperature and lower chlorinated PCB congeners, but $C_p$ showed irregular distribution. The average PCB sampling rates from air to pine needles were 0.116 (0.002-0.389) $m^3$/day - g dry. Conclusions: A poor correlation was shown between $C_a$ and $C_p$. However, a good correlation was shown between the logarithm of octanol-air partitioning coefficient ($logK_{oa}$) and log ($C_p/C_a$), and the interrelation was better with longer sampling time (June to December) than shorter sampling time (June to August). The average PCB sampling rates from air to pine needles were the lowest with respect to PUF disk, XAD-2 resin and semipermeable membrane devices (SPMDs) PAS. The average ratio ($C_{a-calc}/C_{a-meas}$) of calculated ($C_{a-calc}$) and measured ($C_{a-meas}$) PCB concentration was 0.69 with a shorter sampling time and 1.24 with a longer, so $C_{a-calc}$ was close to $C_{a-meas}$. It was found that pine needles can be used as PAS of atmospheric PCBs, and are especially suitable for long-time PAS.

Relationship of the Redox State of Pyridine Nucleotides and Quinone Pool with Spectral Complex Formation in Rhodobacter sphaeroides 2.4.1 (Rhodobacter sphaeroides 2.4.1 내의 pyridine nucleotide와 quinone pool의 redox 상태와 광합성기구의 합성과의 상관관계)

  • Ko, In-Jeong;Oh, Jeong-Il
    • Journal of Life Science
    • /
    • v.19 no.7
    • /
    • pp.852-858
    • /
    • 2009
  • The homeostasis of the pyridine nucleotide pool [NAD(P)H and NAD(P)$^+$] is maintained in Rhodobacter sphaeroides mutant strains defective in the cytochrome bci complex or the cytochrome c oxidases in terms of its concentration and redox state. Aerobic derepression of the puf operon, which is under the control of the PrrBA two-component system, in the CBB3 mutant strain of R. sphaeroides was shown to be not the result of changes in the redox state of the pyridine nucleotides and the ubiquinone/ubiquinol pool. Using the bc$_1$ complex knock-out mutant strain of R. sphaeroides, we clearly demonstrated that the inhibitory effect of cbb$_3$, oxidase on spectral complex formation is not caused indirectly by the redox change of the ubiquinone/ubiquinol pool.

Performance Improvement of Precooling Process and Cold Box in Hydrogen Liquefaction Process Using LNG Cold Energy (LNG 냉열이용 액체수소 제조공정의 예냉 및 Cold box의 성능 개선 연구)

  • Yun, Sang-Kook;Yoon, Na-Eun
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.56-61
    • /
    • 2020
  • For the hydrogen liquefaction, the large amount of energy is consumed, due to precooling, liquefaction and o-p conversion processes. The aim of this work is to improve the performance of hydrogen liquefaction process by introducing the new energy saving processes, that are the liquid nitrogen precooling process by using LNG cold energy, and the new design of cold box insulation using cold air circulation. The results show that the indirect use of LNG cold energy in precooling process enables not only to get energy saving, but to make safer operation of liquefaction plant. In new cold box, the energy loss of equipments could be reduced by nearly 35%~50% compared to the present perlite insulation, if insulation structure is organised as 3mm steel wall/20cm PUF/5cm air/20cm PUF/equipment. Additionally the equipments installed in cold box can get cooling effect, if the temperature is higher than the temperature of cold air. The application of this results can gives to increase the liquid yield of about 50% substantially in industrial hydrogen liquefaction plant.

Synthesis of Polyurethane Foam/Organonanoclay/Phosphates Composites and its Characterization (폴리우레탄폼/유기나노점토/포스페이트 복합체의 합성과 그 특성)

  • Park, Kyeong-Kyu;Lee, Sang-Ho
    • Elastomers and Composites
    • /
    • v.46 no.4
    • /
    • pp.343-351
    • /
    • 2011
  • We prepared polyurethane foam/cloisite30B/phosphates composites and characterized their rise time, density, cell morphology, and thermal properties. The composites were synthesized with polyadipatediol-cloisite30B composite (f=2.0), polyether-polyol (f=4.6), polymeric 4,4-diphenyl methane diisocyanate (f=2.5), and D-580 (phenyl polyoxyalkenyl phosphate). As a blowing agent, cyclopentane and distilled water were used at various concentrations of D-580 from 0 to 2.81 wt%. The rise times of PUF/Closite30B/Phosphate composites blown with distilled water were faster than those blown with cyclopentane by 30%. The composites blown with cyclopentane had spherical-shape cells and the cell diameter was decreased with increasing D-580 wt%. While $T_g$ of the composites blown with cyclopentane linearly decreased with increasing the D-580 content, the $T_g$ of the composites blown with distilled water increased with the D-580 content. All PUF/Closite30B/Phosphate composites began to decompose from $250^{\circ}C$. The composites blown with cyclopentane showed the second thermal decomposition at temperatures higher than $500^{\circ}C$. The thermal stability of all composites increased with the D-580 content. The effect of D-580 on the thermal stability of the composites was measured higher at the composites blown with distilled water.

Gas-particle Partitioning of Organochlorine Pesticides in Atmosphere (대기 중 유기염소계 살충제의 가스-입자 분배)

  • Choi, Min-Kyu;Chun, Man-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.4
    • /
    • pp.457-465
    • /
    • 2007
  • This study was performed to estimate the gas-particle partitioning of organochlorine pesticides (OCPs) in atmosphere, the samples were collected by PUF high volume air sampler for two years from June, 2000 to June, 2002. The gas phase fraction of ${\alpha/\gamma}-HCH$, heptachlor epoxide, ${\alpha/\gamma}-chlordane$ and trans-nonachlor was over 90%. But the gas phase fraction of ${\beta}-HCH$, p,p'-DDE, endosulfan sulfate, p,p'-DDD and p,p'-DDT was range of 20% through 80%, which means the gas phase fraction of OCPs components described above is sensitive to temperature. The correlation between the gas phase fraction and molecular weight of each OCPs component was not found in this research. The slope of regression line between gas-particle partitioning coefficient(${\log}K_p$) and subcooled liquid vapor(${\log}{P^o}_L$), gal-particle partitioning coefficient(${\log}K_p$) and octanol-air partitioning coefficient(${\log}K_{oa}$) which show -0.54 and 0.43 was not steep. So the equilibrium state between gas and particle was not reached and in this state the particulate fraction was low.

Relationship between PAHs Concentrations in Ambient Air and Deposited on Pine Needles

  • Chun, Man-Young
    • Environmental Analysis Health and Toxicology
    • /
    • v.26
    • /
    • pp.4.1-4.6
    • /
    • 2011
  • Objectives: This study was carried out to determine whether or not pine needles can be used as passive samplers of atmospheric polycyclic aromatic hydrocarbons (PAHs) using the correlation between accumulated PAH concentrations in air (Ca, ng/$m^3$) and those deposited on pine needles (Cp, ng/g dry). Methods: PAHs in ambient air was collected using low volume PUF sampler and pine needles was gathered at same place for 7 months. Results: A good correlation ($R^2$=0.8582, p<0.05) was found between Ca and Cp for PAHs with a higher gaseous state in air (AcPy, Acp, Flu, Phen, Ant, Flt, Pyr, BaA and Chry), but there was a poorer correlation ($R^2$=0.1491, p=0.5123) for the PAHs with a lower gaseous state (BbF, BkF, BaP, DahA, BghiP and Ind123). A positive correlation ($R^2$=0.8542) was revealed between the logarithm of the octanol-air partitioning coefficient ($logK_{oa}$) and Cp/Ca for the PAHs with a higher gaseous state in air, but there was a negative correlation ($R^2$=0.8131) for the PAHs with a lower gaseous state. The Ca-Cp model could not be used to estimate PAHs concentrations in air using deposited PAHs concentrations on pine needles, but the logKoa-Cp/Ca model could be used. Conclusions: It was found that pine needles can be used as passive samplers of atmospheric PAHs.

Dynamic Response of Polyurethane Foam with Density and Temperature Effects (폴리우레탄 폼의 동적 응답에 미치는 밀도 및 온도의 영향)

  • Hwang, Byeong-Kwan;Kim, Jeong-Hyun;Kim, Jeong-Dae;Lee, Jae-Myung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.56 no.4
    • /
    • pp.291-297
    • /
    • 2019
  • Polyurethane foam is the most efficient, high-performance insulation material, used for liquefied natural gas carrier (LNGC) insulation. Because LNGC is exposed to sloshing impact load due to ship motion of 6 degrees of freedom, polyurethane foam should be sufficient dynamic properties. The dynamic properties of these polyurethane foam depends on temperature and density. Therefore, this study investigates the dynamic response of polyurethane foam for various temperature($25^{\circ}C$, $-70^{\circ}C$, $-163^{\circ}C$) and density($90kg/m^3$, $113kg/m^3$, $134kg/m^3$, $150kg/m^3$) under drop impact test with impact energy of 20J, 50J, and 80J. For dynamic response was evaluated in terms of peak force, peak displacement, absorb energy, and the mechanical property with minimized density effects. The results show the effect of temperature and density on the polyurethane foam material for the dynamic response.

Charge-discharge capacity and AC impedance of $LiMn_{2-y}M_{y}O_{4}$(M=Mg, Zn) cathode ($LiMn_{2-y}M_{y}O_{4}$(M=Mg, Zn) 정극의 충방전 용량 및 AC 임피던스 특성)

  • 정인성;위성동;이승우;구할본
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.455-458
    • /
    • 2001
  • Spinel $LiMn_{2-y}$$M_{y}$ $O_4$powder was prepared solid-state method by calcining the mixture of LiOH - $H_2O$, Mn $O_2$, ZnO and MgO at 80$0^{\circ}C$ for 36h. To investigate the effect of substitution with Mg, Zn cation, charge-discharge experiments and initial impedance spectroscopy performed. The structure of $LiMn_{2-y}$$M_{y}$ $O_4$crystallites was analyzed from powder X-ray diffraction data as a cubic spinel, space group Fd3m. all cathode material showed spinel phase based on cubic phase in X-ray diffraction. Ununiform which calculated by (111) face and (222) face was constant in spite of the change of y value, except PUf\ulcorner LiM $n_2$ $O_4$. The discharge capacities of the cathode for the cation subbstitUtes $LiMn_{2-y}$$M_{y}$ $O_4$/Li cell at the 1st cycle and at the 40th cycle were about 120~124 and 108~112mAh/g except LiM $n_{1.9}$Z $n_{0.1}$ $O_4$/Li cell, respectively. This cell capacity is retained by 93% after 40th cycle. AC impedance of $LiMn_{2-y}$$M_{y}$ $O_4$/Li cells revealed the similar resistance of about 65~110$\Omega$ before cycling. before cycling.g.g.

  • PDF