발성역치능력(Phonation Threshold Power, PTW)의 타당도 및 임상적 유용성 연구: 예비연구 (A Study on the Validation of Phonation Threshold Power and the Clinical Usefulness of PTW: A Preliminary Study)

  • 황영진;이인애
    • 말소리와 음성과학
    • /
    • 제6권2호
    • /
    • pp.133-138
    • /
    • 2014
  • This study attempted to investigate the validation of Phonation Threshold Power of Patients who have Functional voice disorder. 50 subjects participated in the study (32 subjects were patients who had functional voice disorders and 20 subjects were normal adults). The PAS (Phonatory aerodynamic system, model 6600, KAY electronics, Inc.) was used to measure the data and to do the analysis. Data from the Phonation Threshold Power was measured multiplying Phonation Threshold Pressure and Phonation Threshold Airflow. Phonation Threshold Pressure and Phonation Threshold Airflow were measured by the PAS protocol. Those were used because of the ease of phonation. The results of this study showed that the differences in Phonation Threshold Power between patients who had functional voice disorder and normal adults could become a significant index. Patients who had functional voice disorder showed more higher figures than normal adults. The results of study showed that Phonation threshold Power is more sensitive than Phonation Threshold Pressure and Phonation Threshold Airflow. The measured data also provided useful information for diagnosing patients with vocal fold.

6 MeV 전자 빔의 교정에 원통형 이온함의 사용에 관한 연구 (The Study on the Use of a Cylindrical Ionization Chamber for the Calibration of a 6 MeV Electron Beam)

  • 김성훈;허현도;최상현;최진호;김혁주;임천일;신동오
    • 한국의학물리학회지:의학물리
    • /
    • 제20권4호
    • /
    • pp.317-323
    • /
    • 2009
  • 6 MeV 전자빔과 같은 저메가전압 전자빔 교정 시에 물흡수선량에 기반한 선량측정 체계에선 평행평판형 이온함을 사용하도록 하고 있다. 이러한 전자 에너지 범위에선 원통형 이온함을 정기적 기준 선량측정으로서 사용되어서는 안되지만, 사용자 편의상 임시적 사용 가능성에 대해 살펴보고자 하였다. 본 연구에선 빔 선질 $R_{50}=2.25\;g/cm^2$인 명목 에너지 6 MeV 전자빔의 경우에 원통형 이온함인 PTW30013 이온함의 사용가능성에 대해 조사하였다. 2차 표준기관인 식품의약품안전청(KFDA)으로부터 10개 이온함에 대해 물흡수선량 교정인자 $N_{D,W,Q_0}$를 받았다. 교차교정된 평행평판형 ROOS 이온함으로 6 MeV 전자빔에 대해 측정한 선량값을 사용하여 "임시적" $k_{Q,Q_0}$값을 구하였다. 10개의 이온함에 대해 평균한 값인 "0.9352"를 해당 선질에 대한 이온함의 $k_{Q,Q_0}$로 간주하여 흡수선량을 계산하였다. ROOS 이온함으로 측정한 선량값과 최대 2% 범위 안에서 일치하였다. 사용자 편의상 원통형 이온함을 사용해야 하는 경우에 이 "0.9352" 값을 본 연구의 빔선질과 이온함에 대한 빔선질보정인자로서 임시적으로 사용할 수 있으리라고 본다.

  • PDF

흡수선량 측정 시 동종 원통형 이온함에서 이온함 간 변화 (Chamber-to-chamber Variations in the Same Type of a Cylindrical Chamber for the Measurements of Absorbed Doses)

  • 김성훈;허현도;최상현;김혁주;임천일;신동오;최진호
    • 한국의학물리학회지:의학물리
    • /
    • 제21권1호
    • /
    • pp.120-125
    • /
    • 2010
  • 물흡수선량에 기반한 표준 측정법을 사용하여 흡수선량을 측정 시에 여러 요인들이 크건, 작건, 미미하건 간에 선량 측정의 정확성에 영향을 미칠 수 있다. 이온함의 선질 보정 인자(the beam quality correction factor) ${\kappa}_{Q,Q_0}$ 값 또한 그 중 한 요인이 될 수 있다. 본 연구에서는 특정 이온함 유형(PTW30013, PTW, Germany)을 선정하여, 국내에서 사용하고 있는 기관들로부터 9개의 이온함을 수집하였다. 동일한 전위계와 전기선으로 9개 이온함을 국내 이차표준기관으로부터 교정을 받았다. 이렇게 교정받은 이온함들을 사용하여 Siemens ONCOR 장비의 광자 빔 6 MV와 10 MV 그리고 전자 빔 12 MeV에 대해 기준 조건하에서 흡수선량을 측정하였다. 이온함 간 선량 값의 최대 차이는 광자 빔 6 MV의 경우엔 2.4%, 10MV의 경우에 0.8%, 전자 빔 12 MeV의 경우엔 0.8%이었다. 6 MV에서의 큰 차이는 측정 과정에 문제가 없었다면, 동일한 ${\kappa}_{Q,Q_0}$ 값을 모든 이온함에 적용한 게 한 요인이 될 수 있다. 이는 또한 외부 독립검사가 왜 중요한지를 보여 주는 예라 하겠다.

원통형 전리함을 이용한 Ir-192 선원에 대한 공기커마세기 측정 시 선질보정에 관한 연구 (Quality Correction for Ir-192 Gamma Rays in Air Kerma Strength Dosimetry Using Cylindrical Ionization Chambers)

  • 정동혁;김진기;김기환;오영기;김수곤;이강규;문성록
    • 한국의학물리학회지:의학물리
    • /
    • 제20권1호
    • /
    • pp.30-36
    • /
    • 2009
  • Co-60 선원에 대해 교정된 원통형 전리함 이용하여 Ir-192 선원에 대한 공기커마세기를 측정하는 경우에 선질 차이에 대한 보정이 필요하다. 본 연구에서는 측정학적 방법을 적용하여 PTW-N30001과 N23333 전리함에 대하여 Ir-192 감마선에 대한 선질 인자를 결정하였다. Ir-192 선원(microSelectron)의 에너지스펙트럼을 적용할 경우에 선질인자($k_u$)는 두 전리함에 대해 각각 $k_u$=1.016 (N30001)과 $k_u$=1.017 (N23333)으로 계산되었다. 치료용 microSelectron 선원에 대해 선질 인자를 적용하여 공기커마 세기를 측정하였으며 결과를 기준값과 비교하였다. 결과적으로 선질인자를 적용하는 경우에 기준 공기커마율과 약 -0.5% 이내의 차이를 보였으며 적용하지 않는 경우에는 약 -2.0%의 차이를 보였다.

  • PDF

Mutagenicity and Immune Toxicity of Emulsion-type Sausage Cured with Plasma-treated Water

  • Kim, Hyun-Joo;Sung, Nak-Yun;Yong, Hae In;Kim, Hanwool;Lim, Younggap;Ko, Kwang Hyun;Yun, Cheol-Heui;Jo, Cheorun
    • 한국축산식품학회지
    • /
    • 제36권4호
    • /
    • pp.494-498
    • /
    • 2016
  • Cold plasma has been developed to reduce microbial contamination and to improve safety of food and medical products. In addition, the technology can be used in the manufacture of sausages without addition of nitrite. To be applied in food industry commercially, the new technology should be safe and efficient. However, toxicological test of plasma-treated food is limited. Therefore, the purpose of this study was to determine the mutagenicity and immune toxicity of the meat products cured with plasma-treated water (PTW) as a nitrite source. Emulsion sausages were prepared with no nitrite (control), sodium nitrite (SCS), and PTW (SCP). For a mutagenicity test, the Ames test was performed with the sausage samples. For immune toxicity test, 8-wk-old female Balb/c mice were given free access to the sausages in order to evaluate the tumor necrosis factor (TNF)-α level. As a result, no mutagenicity was detected in the sausages by the Ames test. The serum TNF-α values were less than 10 pg/mL in mice after feeding control and treated samples for 32 d, indicating that no inflammatory response was occurred by feeding the sausages made by PTW. Therefore, the present study opens the possibility of using plasma-treated water as a nitrite source without any toxicity.

Development of a polystyrene phantom for quality assurance of a Gamma Knife®

  • Yona Choi;Kook Jin Chun;Jungbae Bahng;Sang Hyoun Choi;Gyu Seok Cho;Tae Hoon Kim;Hye Jeong Yang;Yeong Chan Seo;Hyun-Tai Chung
    • Nuclear Engineering and Technology
    • /
    • 제55권8호
    • /
    • pp.2935-2940
    • /
    • 2023
  • A polystyrene phantom was developed following the guidance of the International Atomic Energy Association (IAEA) for gamma knife (GK) quality assurance. Its performance was assessed by measuring the absorbed dose rate to water and dose distributions. The phantom was made of polystyrene, which has an electron density (1.0156) similar to that of water. The phantom included one outer phantom and four inner phantoms. Two inner phantoms held PTW T31010 and Exradin A16 ion chambers. One inner phantom held a film in the XY plane of the Leksell coordinate system, and another inner phantom held a film in the YZ or ZX planes. The absorbed dose rate to water and beam profiles of the machine-specific reference (msr) field, namely, the 16 mm collimator field of a GK PerfexionTM or IconTM, were measured at seven GK sites. The measured results were compared to those of an IAEA-recommended solid water (SW) phantom. The radius of the polystyrene phantom was determined to be 7.88 cm by converting the electron density of the plastic, considering a water depth of 8 g/cm2. The absorbed dose rates to water measured in both phantoms differed from the treatment planning program by less than 1.1%. Before msr correction, the PTW T31010 dose rates (PTW Freiberg GmbH, New York, NY, USA) in the polystyrene phantom were 0.70 (0.29)% higher on average than those in the SW phantom. The Exradin A16 (Standard Imaging, Middleton, WI, USA) dose rates were 0.76 (0.32)% higher in the polystyrene phantom. After msr correction factors were applied, there were no statistically significant differences in the A16 dose rates measured in the two phantoms; however, the T31010 dose rates were 0.72 (0.29)% higher in the polystyrene phantom. When the full widths at half maximum and penumbras of the msr field were compared, no significant differences between the two phantoms were observed, except for the penumbra in the Y-axis. However, the difference in the penumbra was smaller than variations among different sites. A polystyrene phantom developed for gamma knife dosimetry showed dosimetric performance comparable to that of a commercial SW phantom. In addition to its cost effectiveness, the polystyrene phantom removes air space around the detector. Additional simulations of the msr correction factors of the polystyrene phantom should be performed.

산업용 수변전 계통의 근사화 해석 기법 (Approximated Analysis method of Industrial Distribution System)

  • 이배희;설용태
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.172-174
    • /
    • 1999
  • In this paper the approximated analysis method of industrial distribution system using PTW(Power Tools for Windows). System input data, cable impedance and transformer data etc., were calculated by the approximated method using EMTP(Electro Magnetic Transient Program). The effectiveness of this method was improved by electrical characteristics analysis of real factory.

  • PDF

Feasibility Study of Mobius3D for Patient-Specific Quality Assurance in the Volumetric Modulated Arc Therapy

  • Lee, Chang Yeol;Kim, Woo Chul;Kim, Hun Jeong;Lee, Jeongshim;Huh, Hyun Do
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.120-127
    • /
    • 2019
  • Purpose: This study was designed to evaluate the dosimetric performance of Mobius3D by comparison with an aSi-based electronic portal imaging device (EPID) and Octavius 4D, which are conventionally used for patient-specific prescription dose verification. Methods: The study was conducted using nine patients who were treated by volumetric modulated arc therapy. To evaluate the feasibility of Mobius3D for prescription dose verification, we compared the QA results of Mobius3D to an aSi-based EPID and the Octavius 4D dose verification methods. The first was the comparison of the Mobius3D verification phantom dose, and the second was to gamma index analysis. Results: The percentage differences between the calculated point dose and measurements from a PTW31010 ion chamber were 1.6%±1.3%, 2.0%±0.8%, and 1.2%±1.2%, using collapsed cone convolution, an analytical anisotropic algorithm, and the AcurosXB algorithm respectively. The average difference was found to be 1.6%±0.3%. Additionally, in the case of using the PTW31014 ion chamber, the corresponding results were 2.0%±1.4%, 2.4%±2.1%, and 1.6%±2.5%, showing an average agreement within 2.0%±0.3%. Considering all the criteria, the Mobius3D result showed that the percentage dose difference from the EPID was within 0.46%±0.34% on average, and the percentage dose difference from Octavius 4D was within 3.14%±2.85% on average. Conclusions: We conclude that Mobius3D can be used interchangeably with phantom-based dosimetry systems, which are commonly used as patient-specific prescription dose verification tools, especially under the conditions of 3%/3 mm and 95% pass rate.

6 MV 광자빔에 대한 MicroLion 액체이온함의 특성 연구 (A Study of Characteristics of MicroLion Liquid Ionization Chamber for 6 MV Photon Beam)

  • 최상현;허현도;김성훈;지영훈;김금배;김우철;김헌정;신동오;김찬형
    • 한국의학물리학회지:의학물리
    • /
    • 제22권4호
    • /
    • pp.216-223
    • /
    • 2011
  • 최근 PTW사에서는 물등가물질로 구성되어 있고, 측정체적(sensitive volume, $0.002cm^3$)이 매우 작은 MicroLion 액체이온함을 내놓았다. 본 연구의 목적은 외부방사선 치료용 광자빔에 대해 MicroLion 액체이온함의 선량선형성, 선량률의존성, 공간분해능, 그리고 출력인수와 같은 선량측정학적 특성을 조사하는 것이다. 이 결과를 Semiflex 이온함($0.125cm^3$), Pinpoint 이온함($0.015cm^3$), 다이오드 검출기($0.0025mm^3$)의 결과와 비교분석하여 소조사면 측정에 적절한지를 평가하고 자 하였다. Varian clinac 2300 C/D의 6 MV 광자빔에서 측정하였으며, MP3 물팬톰(PTW, Freiburg)을 이용하였다. 공간분해능은 반음영(penumbra)을 측정하여 평가하였으며, $0.5{\times}0.5cm^2$에서 $10{\times}10cm^2$까지 다양한 조사면에 대하여 측정하였다. 출력인수는 $0.5{\times}0.5cm^2$에서 $40{\times}40cm^2$에 대하여 측정하였다. 선량에 따른 MicroLion 액체이온함의 측정값은 선형적인 비례성을 보였다. 그러나 선량률은 100 MU/min와 600 MU/min에 의한 측정값의 차이가 최대 5%의 차이를 보였으며, 선량율이 커질수록 출력선량이 작아지는 결과를 보였다. 공간분해능의 경우 조사면 $0.5{\times}0.5cm^2$에서 $10{\times}10cm^2$까지의 측방선량분포 비교에서 Semiflex 이온함을 제외한 다른 모든 검출기들의 경우 2% 이내에서 일치하였다. 출력선량은 $2{\times}2cm^2$에서 $10{\times}10cm^2$ 조사면에서 Semiflex 검출기 대비 모든 검출기가 2% 이내에서 잘 일치하였다. 연구 결과 MicroLion 액체이온함은 물등가물질로 이루어져 있으며, 감응 면적이 매우 작기 때문에 소조사면에서 매우 유용할 것으로 사료된다.

교정정수 변화에 의한 원통형이온함의 안정성 평가 (Evaluation of the Long-Term Stability for the Cylindrical Ionization Chambers)

  • 라정은;홍주영;김귀야;임천일;정희교;신동오;서태석
    • Radiation Oncology Journal
    • /
    • 제24권2호
    • /
    • pp.138-143
    • /
    • 2006
  • 목적: 식품의약품안전청(Korea Food Drug Administration, KFDA)의 도움을 받아 1998년부터 2004년까지 장기간에 걸친 교정정수의 분석을 통해 원통형이온함의 모델별 안정성을 확인하고자 한다. 대상 및 방법: 치료방사선기관에서 교정을 의뢰한 이온함 중 Farmer형의 원통형이온함만을 대상으로 하였으며 모델은 PTW사의 30001 (30006), 30013, 30002, 30004, 23333과 Capintec사의 PR06C, NE사의 2571, Exradin사의 A12 그리고 Wellhofer사의 FC65G (IC70) 등 총 9개 종류의 이온함에 대해 에어커마 교정정수 및 물흡수선량 교정정수를 분석하였으며 에어커마 교정정수를 이용하여 계산한 물흡수선량 교정정수(cal. $N_{D,W}$)와 실제측정에 의해 결정된 물흡수선량 교정정수(mea. $N_{D,W}$)를 상호 비교하였다. 결과: 교정정수 변화를 분석해 본 결과, PTW사의 30013 (30006), Wellhofer사의 FC65G (IC70) 그리고 NE사의 2571 이온함의 경우 측정 표준편차 0.2% 이내에서 잘 일치하여 다른 모델의 이온함에 비해 안정된 값을 가지는 것으로 나타났으며 계산에 의한 물흡수선량 교정정수와 실제 측정에 의해 결정된 물흡수선량 교정정수를 비교 분석한 결과는 모든 이온함에서 측정에 의한 물흡수선량 교정정수가 약 1.0% 큰 것으로 나타났다. 결론: 본 연구에서는 원통형이온함의 교정정수 값들에 대하여 장기간의 안정성 평가를 토대로 임상에서 요구되는 이온함의 선택 기준을 제시함으로써 표준체계에 따른 이온함의 선택 뫼 선량측정의 정확성을 향상시킬 것으로 기대한다.