• Title/Summary/Keyword: PTV

Search Result 394, Processing Time 0.024 seconds

Synthesis of PPV-PTV Alternating Copolymer and EL Devices Using the Polymer

  • 황도훈;정상돈;도래미;안택;심홍구;정태형
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.3
    • /
    • pp.332-335
    • /
    • 1998
  • An alternating copolymer of PPV and PTV, poly[2-methoxy-5-(3,7-dimethyl)octyloxy-1,4-phenylenevinylene-alt-2,5-thienylenevinylene] (DAPPV-PTV) has been synthesized and light-emitting properties of the polymer have been studied. A single layer EL device using DAPPV-PTV as an emitting layer between ITO and Al electrodes (ITO/DAPPV-PTV/Al) has been fabricated, and light emission of the device becomes visible at 3 V. The EL emission maximum of the device is about 620 nm. Double layer EL device using DAPPV-PTV and Alq3 (ITO/DAPPV-PTV/Alq3/Al) has also been fabricated. The double layer EL device shows two-color emission depending on the applied voltage. The device emits a pale green color from 8 V, and then the color turns to red at about 18 V.

[ $PERIOTEST^{(R)}$ ] ASSESSMENT OF DENTAL IMPLANT MOBILITY : A CLINCAL STUDY ($PerioTest^{(R)}$를 이용한 임플란트 동요도에 관한 임상적 연구)

  • Kim, Sun-Jai;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.5
    • /
    • pp.758-771
    • /
    • 1998
  • Assessment of implant mobility is an important and reliable method to clinically evaluate implant stability. PerioTest is a precise and reproducible device that cam dynamically measure the reaction of damping characteristics of peri-implant tissue. The aim of this study is to evaluate the effects of amount of implant surface area, diameter, type, implantation site, degrees of cortical engagement, and length of time in function on PTVs and to find out the most determining factor on PTVs. The results are as follows 1. 5.0mm diameter implants show significantly lower PTV than that of 3.75mm diameter implants. 2. PTV in the mandible is significantly lower than that of the maxilla 3. In the maxilla, there is no significant difference in PTV during the first year of implant function, but during the second year a significant decrease in PTV is noted. 4. In the mandible, there is a significant decrease in PTV during the first and second year of implant function. 5. Implantation site seems to be the most determining factor on PTV among the influencing factors in this study. In conclusion, the amount of implant surface area, type, degrees of cortical engagement had no significant effect on PTV, but installation site and diameter influenced significantly on PTV

  • PDF

MOBILITY OF NATURAL TEETH AND OSSEOINTEGRATED IMPLANTS (자연 치아와 골유착성 임플랜트의 동요도에 관한 연구)

  • Jang, Kyoung-Soo;Kim, Yong-Ho;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.1
    • /
    • pp.144-155
    • /
    • 1995
  • It is well known that implants showing no clinical mobility are successfully osseointegrated and have good prognosis. When implants are under load, their mobility begins to increase. It is of necessity to substantiate whether excessive load is on or premature occlusal force is acting prior to desirable osseointegration. Using Periotest unit, we could measure the pattern of mobility change. Consequently, osseointegrated treatment has come to success by intercepting progressive mobility and doing perceptive treatment according to the result of Periotest Value(PTV). In this study, we took records of intangible mobility of 70 osseointegrated implants. And we also measured the mobility of periodontally sound natural teeth as a standard from 30 dental personnel. Conclusions were summarized as followings ; 1. Lower lateral incisor has the highest PTV, whereas lower canine, upper canine, lower premolars and lower 1st molar have the lowest PTV in natural dentition. 2. There are little significant statistical difference of PTV between men and women in both(natural and implant) dentition. 3. In general, lower natural teeth show lower PTV than upper counterpart. 4. Mandibular implants have lower PTV than those of maxillary implants. 5. All of the successfully osseointegrated implants have lower PTV than those of periodontally healthy teeth.

  • PDF

Development of High-Definition 3D-PTV and its Application to High-Precision Measurements of a Sphere Wake (고해상 3차원 입자영상유속계 개발과 구 유동장 정밀해석 적용연구)

  • Hwang Tae-Gyu;Doh Deog-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.12
    • /
    • pp.1161-1168
    • /
    • 2005
  • A Multi-Sectional 3D-PTV algorithm was developed to reduce the calculation time of the conventional GA-3D-PTV. The hardware system of the constructed 3D-PTV system consists of two high-speed cameras ($1,024\times1,018$ pixels, 60 fps), a metal halogen lamp (400W) and a host computer. The sphere(D=30mm) is suspended in a circulating water channel $(300mm\times300mm\times1,200m)$ and Reynolds number is 1,130. About 5,000 instantaneous three-dimensional velocity vectors have been obtained by the constructed 3D-PTV system. Turbulent properties such as turbulent intensity, Reynolds stress and turbulent kinetic energy were obtained. An eigenvalue analysis was carried out using the obtained instantaneous 3D velocity vectors to get the topological relations of the asymptotically stable critical point. Two structured shells, inner shell and outer shell, were found in the sphere wake and their motions were clarified by the measured data.

Synthesis and Electro-optical Properties of π-Conjugated Polymer Based on 10-Hexylphenothiazine and Aromatic 1,2,4-Triazole

  • Choi, Ji-Young;Kim, Dong-Han;Lee, Bong;Kim, Joo-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.9
    • /
    • pp.1933-1938
    • /
    • 2009
  • New $\pi$-conjugated polymer with vinylene linkage, poly((10-hexyl-3,7-phenothiazine)-alt-(4-(4-butyl-phenyl)- 3,5-diphenyl-4H-[1,2,4]triazole)-3,5-vinylene) (PTV-TAZ) was synthesized by the Heck coupling reaction. The photoluminescence (PL) maximum wavelength and the band gap energy of PTV-TAZ film were 555 nm and 2.41 eV, respectively. The HOMO energy level of PTV-TAZ was -4.99 eV, which was slightly lower than that of PTV (-4.89 eV). Electron deficient aromatic 1,2,4-triazole (TAZ) in the polymer backbone does not affect the HOMO energy level significantly. The maximum efficiency and brightness of double layer structured electroluminescent (EL) device (ITO/PEDOT (30 nm)/PTV-TAZ (60 nm)/Al) were 0.247 cd/A and 553 cd/$m^2$, respectively, which were significantly higher than those of the device based PTV (1.65 ${\times}\;10^{-4}$ cd/A and 4.3 cd/$m^2$). This is due to that TAZ unit improves electron transporting ability in the emissive layer. The turn-on voltage (defined as the voltage required to give a luminescence of 1 cd/$m^2$) of brightness of the device based on PTV-TAZ was 12.0 V, which was similar to that the based on PTV (11.5 V). This is due to that the ionization potential of PTV-TAZ is very similar to that of PTV.

3D-PTV Measurements of the Wake of a Goldfish (3D-PTV에 의한 금붕어 후류 계측)

  • Doh, D.H.;Hwang, T.G.;Chang, G.S.;Bang, Y.S.;Sang, J.W.;Kim, D.J.;Baek, T.S.;Cho, Y.B.;Pyun, Y.B.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2054-2059
    • /
    • 2003
  • 3D-PTV measurement was conducted on the wake of a goldfish in order to understand its swimming motions. The measurement system consisted of three CCD cameras, an image grabber, an Ar-Ion laser and a host computer. The flow properties of the wake of the goldfish were measured under three different velocities of the currents. Unsteady flow structures around the goldfish were quantitatively clarified using the time-consecutive instantaneous three-dimensional vectors obtained by the constructed 3D-PTV system.

  • PDF

3D-PTV Measurements of the Statistical Turbulent Properties on the Wake of a Sphere (3D-PTV에 의한 구 후류 난류통계량 계측)

  • Doh, D.H.;Hwang, T.G.;Cho, Y.B.;Baek, T.S.;Pyun, Y.B.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1748-1753
    • /
    • 2003
  • 3D-PTV measurement was conducted on the wake of a sphere. The Reynolds number is 1130 with the diameter(d=30mm). The measurement system consisted of three CCD cameras, an image grabber, an Ar-Ion laser and a host computer. An eigenvalue analysis was introduced for the analysis on the wake. Statistical turbulent properties were quantitatively clarified using the time-consecutive instantaneous three-dimensional vectors obtained by the 3D-PTV system. The spatial distributions of the sphere wake showed strong relations with spiral motions of the vortcies shedded from the surface of the sphere.

  • PDF

4-D PTV

  • Doh Deog Hee;OKAMOTO Koji
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.33-40
    • /
    • 2004
  • A 4D-PTV system was constructed. The measurement system consists of three high-speed high-definition cameras(1k x 1k, 2000fps), Nd-Yag laser(2000Hz) and a host computer. The GA-3D-PTV algorithm was used for completing the measurement system. The 4D-PTV is capable of probing the spatial distribution of velocity vectors of the flow field overcoming the temporal resolution of the characteristic turbulence length scales of the measured flow fields. A horizontal impinged jet flow (H/D=7) was measured. The Reynolds number is about 33,000. Spatial temporal evolution of the jet flow was examined and physical properties such as spatial distributions of vorticity and turbulent kinetic energy were obtained with the constructed.

  • PDF

Measurements of a Ship's Propeller Wake with Stereoscopic-PIV and Stereoscopic-PTV (스테레오 PTV와 스테레오 PIV에 의한 선박프로펠러 후류측정)

  • Doh, Deog-Hee;Hwang, Tae-Gyu;Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.5 no.2
    • /
    • pp.26-32
    • /
    • 2007
  • Stereoscopic PTV and Stereoscopic-PIV measurements have been carried out for the studies of the wake of a ship's propeller. Stereoscopic photogrammetry based on a 3D-PTV principle was introduced using two high-definition cameras(1k x 1k, 30Hz). The arrangement of the two cameras was based on angular position. The pair-matching of the three-dimensional velocity vectors were based on Genetic Algorithm based 3D-PTV technique. The results obtained by both measurement systems have been compared at the advance ratio J=0.88(290 rpm, d=54 mm). Turbulent properties have also been compared each other at the same condition.

Fall Velocity Measurement in the Turbulent Flow Using Image Analysis Method (영상해석 기법을 이용한 난류 흐름 중 침강속도의 측정)

  • Yun, Sang-Hun;Yu, Gwon-Gyu;Yun, Byeong-Man
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.6
    • /
    • pp.745-751
    • /
    • 2001
  • Fall velocities of sand particles in the turbulent flow are analyzed through measurements using PTV. PTV is believed to be the only instrument to measure the fall velocity in the turbulent flow, since it can trace the individual particle. The method is verified by comparison with existing formula for still-water case. The experimental results show that the fall velocity in the turbulent flow decreases compared with that in still water, and decreases by 40% as the turbulent intensity normalized by the friction velocity increases upto 1.

  • PDF