• 제목/요약/키워드: PTFE Composite

검색결과 51건 처리시간 0.028초

가압소결에 의한 PTFE/AI 복합재료 제조 (Fabrication of PTFE/Al Composite Materials by Hot Press Process)

  • 이길근;김우열
    • 한국분말재료학회지
    • /
    • 제9권2호
    • /
    • pp.103-109
    • /
    • 2002
  • To investigate the fabrication possibility of a polymer particle dispersed metal matrix composite, polytetrafluorothylene (PTFE) particles were incorporated into the Al by the powder metallurgy process. The characteristics of a PTFE/Al composite were evaluated by measuring the density and hardness, and analysis of XRD, FT-Raman and microstructure. And wear properties of these composites were evaluated under the dry wear condition. It was possible to obtain the PTFE particles stably dispersed Al matrix composites by the hot press process at the sintering temperature of $500^{\circ}C$. The wear coefficient of a PTFE/Al compoite decreased with increasing of the volume fraction of PTFE. The wear weight of a PTFE/Al composite increased with increasing of the volume fractionof PTFE in the range of 0~10 vol.%PTFE, and showed maximum value at 10 vol.%PTFE, and then decreased at 20vol.%PTFE.

Ni-PTFE 복합도금기술을 이용한 알칼리형 연료전지용 전극 제조 (Preparation of Electrode Using Ni-PTFE Composite Plating for Alkaline Fuel Cell)

  • 김재호;이영석
    • 한국수소및신에너지학회논문집
    • /
    • 제20권5호
    • /
    • pp.361-370
    • /
    • 2009
  • Ni-PTFE composite plated on graphite (C/Ni-PTFE) and PTFE (PTFE/Ni-PTFE) particles were prepared uniformly by electroless composite plating. The conductivity of C/Ni-PTFE particles was 280 S/m higher than 95 S/m of PTFE/Ni-PTFE particles at same composite plating condition (Ni:35~36 wt%, PTFE:8 wt%). The C/Ni-PTFE particles were formed into the C/Ni-PTFE plate using heat treatment at $350^{\circ}C$ under 10~$1000\;kg/cm^2$. The C/Ni-PTFE plate showed 1) high conductivity of $5.7\;{\times}\;10^4\;S/m$ due to the existence of graphite as conducting aid and the formation of 3-dimensional Ni network 2) good gas diffusion caused by various pore volumes (0.01~$100\;{\mu}m$) in the plate. The plate could be useful for an electrode in an alkaline fuel cell (AFC). The current density of C/Ni-PTFE electrode indicated $84\;mA/cm^2$ at 0.3V and it was 3.0 times higher than that of PTFE/Ni-PTFE electrode.

pH에 따른 무전해Ni-P-PTFE 복합도금의 표면형상 및 내식성에 대한 특성 연구 (Characterization of the Morphology and Corrosion Resistance in Electroless Ni-P-PTFE Composite Coating Prepared by Different pH Value)

  • 변영민;서선교;윤진두;나상조;류창환;황환일
    • 한국표면공학회지
    • /
    • 제52권3호
    • /
    • pp.156-162
    • /
    • 2019
  • Electroless Ni-P coatings are widely used in the chemical, mechanical, and electronic industries because of their excellent wear and abrasion resistance. In this study, The influence of pH values on properties of Ni-P-PTFE composite coatings was investigated. To improve mold lubrication, Ni-P-PTFE composite coatings at different pH value were studied. The morphology and phase structure of Ni-P-PTFE composite coatings were analyzed by scanning electron microscopy(SEM) and X-ray diffractometry(XRD). The result showed that Ni-P-PTFE composite coating is composed of Ni, P and PTFE. It exhibits an amorphous structure and good Corrosion Resistance to the substrate. Ni-P-PTFE composite coatings have higher open circuit potential than that of the substrate, which obtained at pH value of 5.0 optimal integrated properties.

Characterizations of Cr-P-PTFE composite coatings electroplated from trivalent chromium-based bath

  • Park, Jong-Kyu;Byoun, Young-Min;Seo, Sun-Kyo;Park, Su-Young;Choi, Sun-Woo
    • Journal of Ceramic Processing Research
    • /
    • 제19권6호
    • /
    • pp.455-460
    • /
    • 2018
  • Chromium plating is a common surface treatment technique extensively applied in industry due its excellent properties which include substantial hardness, abrasion resistance, corrosion resistance, surface color, and luster. In this study, the effect of PTFE on corrosion behavior of Cr-P plating, low carbon steel substrates are electroplated in Cr(III) baths without and with PTFE. Trivalent chromium carbon plating was electroplated from trivalent chromium sulfate-based baths with different PTFE dispersion contents. The study focused on the microstructure, PTFE content, roughness, and corrosion resistance of the Cr-P-PTFE composite plating. Scanning electron microscopy and atomic force microscopy images showed a smoother plating and a decrease in the surface roughness of the electrodeposited. The results demonstrate that PTFE eliminates the cracks within plating by reducing internal stress. Therefore, the corrosion resistance of Cr-P-PTFE composite platings were better than that of Cr-P alloy platings.

PTFE-폴리이미드 복합 재료의 마찰과 마모 특성 (Friction and Wear Characteristics of PTFE-Polyimide Composite)

  • 심현해;권오관
    • Tribology and Lubricants
    • /
    • 제11권4호
    • /
    • pp.28-34
    • /
    • 1995
  • PTFE has good mechanical and chemical stability at wide temperature range, and more over, shows a low value of friction coefficient. On the other hand, it shows cold flow and high wear rate. However, these short comings can be overcome by adding various fillers. In this experiment, PTFE and polyimide powder were mixed into composite and its tribological characteristics was investigated. 100% polyimide was also tested for comparison. The countefface material was a stainless steel (SUS304). Friction and wear tester of ring-on-block type was used at room temperature and under atmosphere. After the wear test, the worn surfaces were examined by optical microscope. The test results show that PTFE-polyimide composite generates. the wear transfer film on both sides of the friction surfaces, and, the friction coefficient and the wear rates are relatively low. 100% polyimide generated little wear transfer films, showed high friction and wear rates, and also showed some problems of vibration and noise. It even damaged the stainless steel countefface. It was concluded that 100% polyimide does not generate transfer film well because its shear resistanbe is high and it stickslips, thus, friction coefficients and wear rates are high. In case of PTFE-polyimide composite, on the other hand, transfer film containing sufficient PTFE adheres and remains on both wear surfaces well enough because PTFE has low shear resistance. Polyimide particles in the composite were proved to be able to bear normal load and does not show stick-slip because they are covered with transfer film containing much PTFE.

PTFE 복합재료의 마찰 . 마모 특성에 미치는 첨가제의 영향 (Effects of Additives on the Friction and Wear Properties of PTFE Composites)

  • 김용직;엄수현;김윤해
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 1999년도 추계학술발표대회 논문집
    • /
    • pp.88-94
    • /
    • 1999
  • Recently, PTFE-polyimide composites are being used self-lubricating parts for industrial field. Thus, this study is mainly concerned with friction and wear properties for the piston ring of non-lubricating air compressor which made of PTFE-polyimide composites. The friction and wear test was carried out for the different composition ratio under the atmosphere room temperature and constant load of 7.69N and their friction and wear properties were compared with each other at various sliding speed. Notable results are summarized as follows. PTFE 100% showed that friction coefficient was almost same values at 0.94 and 1.88m/s but the value was decreased at 2.83m/s because the friction temperature is higher than low speed. PTFE 80%-PI 20% showed the lowest mean friction coefficient at 2.83m/s. PTFE 20%-PI 80% showed the highest friction coefficient at 0.94m/s and the value was decreased at high speed but the value is higher than other materials except PTFE 100 %. PI 100% showed the highest friction coefficient at 0.94 and 1.88m/s because adhesive wear mainly occurred that speed. PTFE 100% showed highest specific wear rate on the whole. Specific wear rate of PTFE 80%-PI 20% was almost the same value with PTFE 20%-PI 80%. PI 100% showed the lowest value at high sliding speed because the friction surface was thicken and carbonated by high friction temperature.

  • PDF

연료전지용 부분불소계 Poly (arylene e ther sulfone)/PTFE 복합막의 제조 및 특성 분석 (Preparation and Characterization of Partially Fluorinated Poly (arylene ether sulfone)/PTFE Composite Membranes for Fuel Cell)

  • 김은희;장봉준;김정훈
    • 멤브레인
    • /
    • 제22권3호
    • /
    • pp.191-200
    • /
    • 2012
  • 불소관능기인 perfluorocyclobutane (PFCB)기를 포함하는 후술폰화 poly (arylene ether sulfone) 랜덤 공중합체를 다공성 Polytetrafluoroethylene (PTFE) 막에 함침시켜 새로운 복합막을 제조하였다. 후술폰화 랜덤 공중합체는 trifluorovinyloxy 그룹을 양말단에 포함하는 biphenyl계와 sulfonyl계 단량체로부터 제조되었는데, biphenyl계와 sulfonyl계의 비율을 6 : 4와 4 : 6으로 조절 후 중부가반응 형태의 열중합과 chlorosulfonic acid (CSA)를 이용한 후술폰화 반응을 통하여 얻어졌다. 이렇게 제조된 랜덤 공중합체의 농도를 달리하면서(5~20 wt%) 다공성 PTFE 막에 함침시켜 복합막을 제조하였고, 이온 교환 능력(IEC), 함수율, 이온전도도를 측정하여 강화되지 않은 랜덤공중합체 및 Nafion과 비교하였다. 제조된 단량체 및 고분자의 구조와 순도는 각각 $^1H$-NMR, $^{19}F$-NMR와 FT-IR를 통하여 확인하였으며, 제조된 복합막의 형태는 SEM으로 관찰하였다.

무급유 공기압축기용 복합재료 피스턴링의 마찰마모 특성에 관한 연구 (A Study on the Friction and Wear Property of Composite Piston Ring for Oil Free Air Compressor)

  • 김용직;정하돈;김윤해
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.766-771
    • /
    • 2000
  • This study is mainly concerned with friction and wear properties for the piston ring of non-lubricating air compressor which made of PTFE-polyimide composites. At the PTFE and polyimide alone mixture specimens, PTFE80%-polyimide20%, which shows the lowest men friction coefficient and specific wear rate at 0.94m/s sliding speed. At each of carbon, copper and oxide lopper mixed with PTFE80%-polyimide20%. In case of copper10%, at 0.94m/s sliding speed, the mean friction coefficient shows 0.087, which is the lowest value in all specimens. In case of the specific wear rate, copper30% specimen shows the lowest value of $2.537E-5(mm^3/Nm)$ in all specimens.

  • PDF

고주파 기판용 PTFE 복합체 형성 압력에 따른 유전 특성 (Dielectric Characteristics of Polytetrafluoroethylene-based Composites for Microwave Substrates with Formation Pressure)

  • 최홍제;전명표;조용수;조학래
    • 한국전기전자재료학회논문지
    • /
    • 제26권6호
    • /
    • pp.429-433
    • /
    • 2013
  • PTFE composites for use of microwave substrate were fabricated by impregnation and heat treatment fabrication with glass fabric. This study shows dielectric properties such as dielectric constant and loss can be controlled by thickness of PTFE composite with change of pressure condition in heating press process. The dielectric constant of the PTFE composites has decreasing tendency as given higher pressure condition. The dielectric loss has similar result too. Especially, the case of the dielectric loss was affected by the condition of pressure at heating press and had the best performance under 3 MPa. In order to see the reason why thickness conditions make different, their microstructures were also observed.