• Title/Summary/Keyword: PS4

Search Result 1,261, Processing Time 0.034 seconds

The Effect of Pressure Support on Respiratory Mechanics in CPAP and SIMV (CPAP 및 SIMV Mode하에서 Pressure Support 사용이 호흡역학에 미치는 효과)

  • Lim, Chae-Man;Jang, Jae-Won;Choi, Kang-Hyun;Lee, Sang-Do;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Park, Pyung-Whan;Choi, Jong-Moo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.3
    • /
    • pp.351-360
    • /
    • 1995
  • Background: Pressure support(PS) is becomimg a widely accepted method of mechanical ventilation either for total unloading or for partial unloading of respiratory muscle. The aim of the study was to find out if PS exert different effects on respiratory mechanics in synchronized intermittent mandatory ventilation(SIMV) and continuous positive airway pressure (CPAP) modes. Methods: 5, 10 and 15 cm $H_2O$ of PS were sequentially applied in 14 patients($69{\pm}12$ yrs, M:F=9:5) and respiratory rate (RR), tidal volume($V_T$), work of breathing(WOB), pressure time product(PTP), $P_{0.1}$, and $T_1/T_{TOT}$ were measured using the CP-100 pulmonary monitor(Bicore, USA) in SIMV and CPAP modes respectively. Results: 1) Common effects of PS on respiratory mechanics in both CPAP and SIMV modes As the level of PS was increased(0, 5, 10, 15 cm $H_2O$), $V_T$ was increased in CPAP mode($0.28{\pm}0.09$, $0.29{\pm}0.09$, $0.31{\pm}0.11$, $0.34{\pm}0.12\;L$, respectively, p=0.001), and also in SIMV mode($0.31{\pm}0.15$, $0.32{\pm}0.09$, $0.34{\pm}0.16$, $0.36{\pm}0.15\;L$, respectively, p=0.0215). WOB was decreased in CPAP mode($1.40{\pm}1.02$, $1.01{\pm}0.80$, $0.80{\pm}0.85$, $0.68{\pm}0.76$ joule/L, respectively, p=0.0001), and in SIMV mode($0.97{\pm}0.77$, $0.76{\pm}0.64$, $0.57{\pm}0.55$, $0.49{\pm}0.49$ joule/L, respectively, p=0.0001). PTP was also decreased in CPAP mode($300{\pm}216$, $217{\pm}165$, $179{\pm}187$, $122{\pm}114cm$ $H_2O{\cdot}sec/min$, respectively, p=0.0001), and in SIMV mode($218{\pm}181$, $178{\pm}157$, $130{\pm}147$, $108{\pm}129cm$ $H_2O{\cdot}sec/min$, respectively, p=0.0017). 2) Different effects of PS on respiratory mechanics in CP AP and SIMV modes By application of PS (0, 5, 10, 15 cm $H_2O$), RR was not changed in CPAP mode($27.9{\pm}6.7$, $30.0{\pm}6.6$, $26.1{\pm}9.1$, $27.5{\pm}5.7/min$, respectively, p=0.505), but it was decreased in SIMV mode ($27.4{\pm}5.1$, $27.8{\pm}6.5$, $27.6{\pm}6.2$, $25.1{\pm}5.4/min$, respectively, p=0.0001). $P_{0.1}$ was reduced in CPAP mode($6.2{\pm}3.5$, $4.8{\pm}2.8$, $4.8{\pm}3.8$, $3.9{\pm}2.5\;cm$ $H_2O$, respectively, p=0.0061), but not in SIMV mode($4.3{\pm}2.1$, $4.0{\pm}1.8$, $3.5{\pm}1.6$, $3.5{\pm}1.9\;cm$ $H_2O$, respectively, p=0.054). $T_1/T_{TOT}$ was decreased in CPAP mode($0.40{\pm}0.05$, $0.39{\pm}0.04$, $0.37{\pm}0.04$, $0.35{\pm}0.04$, respectively, p=0.0004), but not in SIMV mode($0.40{\pm}0.08$, $0.35{\pm}0.07$, $0.38{\pm}0.10$, $0.37{\pm}0.10$, respectively, p=0.287). 3) Comparison of respiratory mechanics between CPAP+PS and SIMV alone at same tidal volume. The tidal volume in CPAP+PS 10 cm $H_2O$ was comparable to that of SIMV alone. Under this condition, the RR($26.1{\pm}9.1$, $27.4{\pm}5.1/min$, respectively, p=0.516), WOB($0.80{\pm}0.85$, 0.97+0.77 joule/L, respectively, p=0.485), $P_{0.1}$($3.9{\pm}2.5$, $4.3{\pm}2.1\;cm$ $H_2O$, respectively, p=0.481) were not different between the two methods, but PTP($179{\pm}187$, $218{\pm}181 cmH_2O{\cdot}sec/min$, respectively, p=0.042) and $T_1/T_{TOT}$($0.37{\pm}0.04$, $0.40{\pm}0.08$, respectively, p=0.026) were significantly lower in CPAP+PS than in SIMV alone. Conclusion: PS up to 15 cm $H_2O$ increased tidal volume, decreased work of breathing and pressure time product in both SIMV and CPAP modes. PS decreased respiration rate in SIMV mode but not in CPAP mode, while it reduced central respiratory drive($P_{0.1}$) and shortened duty cycle ($T_1/T_{TOT}$) in CPAP mode but not in SIMV mode. By 10 em $H_2O$ of PS in CPAP mode, same tidal volume was obtained as in SIMV mode, and both methods were comparable in respect to RR, WOB, $P_{0.1}$, but CPAP+PS was superior in respect to the efficiency of the respiratory muscle work (PTP) and duty cycle($T_1/T_{TOT}$).

  • PDF

Photodegradability of Blends of Polystyrene and Vinyl Ketone Polymers (비닐 케톤계 고분자와 폴리스티렌 블렌드의 광분해성)

  • Kim, Jeong Ho
    • Clean Technology
    • /
    • v.4 no.2
    • /
    • pp.54-60
    • /
    • 1998
  • Polyphenylvinylketone (PPVK) having a carbonyl group at the side chain was blended with polystyrene (PS) to investigate the effect of vinylketone polymers on the photodegradability of the blend as a function of U.V. irradiation time. Hydrogenated polyphenylvinylketone (PPVK(H)) which is made by hydrogenation of some of the carbonyl groups in PPVK was also blended with PS to check the role of carbonyl carbonyl group in the process of photodegradation. Photodegradability was also investigated for blends of PS with polymethylvinylketone (PMVK) and for copolymers of styrene and methylvinylketone (SMVK) to compare the effect of copolymerization versus blending on photodegradability. PPVK showed higher photodegradability than PPVK(H), which followed that the blends of PS with PPVK gave higher degradability than with PPVK(H). In view of the fact that PPVK(H) is a partially hydrogenated version of PPVK, carbonyl group was confirmed to be involved in the photodegradation mechanism. When polymethylvinylketone (PMVK) was blended with PS, this blend showed a higher degradability than PS/PPVK blend. Therefore the highest photodegradability was achieved when PS was blended with PMVK followed by PPVK and PPVK(H) in order. When SMVK was UV irradiated, it showed the highest photodegradability than any blends mentioned above. Therefore, copolymerization was proved to be the better means of photodegradation than blending.

  • PDF

Prestressing Loss Management for PSC Girder Tendon Based on EM Sensing (EM센서를 활용한 PSC 텐던 긴장력 손실 관리)

  • Kim, Junkyeong;Park, Jooyoung;Zhang, Aoqi;Lee, Hwanwoo;Park, Seunghee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.4
    • /
    • pp.369-374
    • /
    • 2015
  • In this paper, an EM sensing based prestressing force estimation method is proposed, in which it can estimate tensile force of PS tendon for PSC girder. The PSC girder has more improved performance than the general concrete girder by introducing the prestressing to the concrete. Thus the PSC girder bridge is widely constructed due to its high performance and low cost. However, the prestressing force has not been managed nevertheless it is major factor for the maintenance of the PSC girder bridge. The prestressing force was just measured during construction using jacking device and after that, it can not be managed. For this reason, this paper proposes a tensile force estimation method of PS tendon based on EM sensor. The permeability of ferroelectric material is changed according to the induced stress to the material, in which it can be measured using EM sensor. To measure the permeability of PS tendon, the EM sensor was fabricated and verified by performing the MTS test. The test was performed using 7-wire steel tendon under the 0, 40, 80, 120, 160, 200 KN of tensile force. The permeability of PS tendon was gradually decreased according to the increasement of tensile force. The regression method was used to find the relation between permeability and stress. As a result, the permeability has linear relation with the tensile force of PS tendon and the pre-stressing force can be estimated by the derived estimation equation.

Risk of Smoke Occurring in the Combustion of Plastics (플라스틱의 연소 시 발생하는 연기 위험성에 관한 연구)

  • You, Jisun;Chung, Yeong-jin
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.69-75
    • /
    • 2019
  • In this study, the combustibility of five types of plastic plates, fiber reinforced plastic (FRP), polystyrene (PS), polycarbonate (PC), polypropylene (PP), and polyvinyl chloride (PVC), were tested using a cone calorimeter (ISO 5660). The PVC plate showed a $44.65kW/m^2$ lower peak heat release rate (HRR) and a $30.97kW/m^2$ lower maximum average rate of heat emission than the other four types of plastics, whereas the PS plate showed a $773.44kW/m^2$ higher peak HRR and $399.14kW/m^2$ higher maximum average rate of heat emission. The PC plate and PS plate showed the highest HRR by a maximum of 3.88 times in $CO_{mean}$ yields, while the PS pate and PP plate showed the highest HRR by a maximum 4.88 times in $CO_{2mean}$ yields. In addition, the smoke performance index (SPI) of the PS plate decreased by 74.81%~95.99%; the smoke growth index (SGI) increased to 76%~300%; the smoke intensity (SI) also increased to 917.73% ~ 9607.57%, and the danger of smoke increased. The PS plate was found to have the highest risk of life damage due to smoke on the thermal and smoke sides.

Removal Characteristics of Sr and Cu Ions using PS-FZ Beads fabricated by Immobilization of Zeolite prepared from Coal Fly Ash from an Ulsan Industrial Complex with Polysulfone (울산산업공단에서 배출되는 coal fly ash로 합성한 제올라이트를 폴리슬폰으로 고정화하여 제조한 PS-FZ 비드의 Sr 및 Cu 제거 특성)

  • Kam, Sang-Kyu;Lee, Chang-Han;Jeong, Kap-Seop;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.25 no.12
    • /
    • pp.1623-1632
    • /
    • 2016
  • Zeolite (FZ) prepared using coal fly ash from an Ulsan industrial complex was immobilized with polysulfone (PS) to fabricate PS-FZ beads. The prepared PS-FZ beads were characterized by scanning electron microscopy and Fourier transform infrared spectroscopy. The optimum ratio for preparing PS-FZ beads was 1 g of PS to 2 g of FZ. The removal efficiencies of Sr and Cu ions by the PS-FZ beads increased as the solution pH increased and nearly reached a plateau at pH 4. A pseudo-second-order model morel fit the adsorption kinetics of both ions by the PS-FZ beads better than a pseudo-first-order model. The Langmuir isotherm model fit the equilibrium data well. The maximum adsorption capacities calculated from the Langmuir isotherm model were 46.73 mg/g and 62.54 mg/g for the Sr and Cu ions, respectively. Additionally, the values of thermodynamic parameters such as free energy (${\Delta}G^{\circ}$), enthalpy (${\Delta}H^{\circ}$) and entropy (${\Delta}S^{\circ}$) were determined. The results implied that the prepared PS-FZ beads could be interesting an alternative material for Sr and Cu ion removal.

Flexural Strength Evaluation of PSC Beam with Loss of PS Tendon Area (PS강재의 단면적 감소에 따른 PSC보의 휨강도 평가)

  • Park, Soon-Hyung;Kim, Yong-Tae;Youn, Seok-Goo;Kim, Eun-Kyum
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.309-312
    • /
    • 2008
  • This paper describes ultimate load tests which were performed to show the effects of prestress loss and tendon corrosion on the flexural strength of post-tensioned concrete beams and the occurrence of wire fracture. Five test specimens were fabricated in laboratory with the variations of the prestress of tendons and the loss of tendon area. For two specimens, small area of tendon at the center of the beam was exposed by using diameter 25mm drill and the exposed tendon was corroded using accelerated corrosion equipment. During the tests, deflections, crack width, and strain changes were measured and acoustic events were monitored with two acoustic sensors. Tests results show that the ultimate flexural strength of test specimens with corroded tendons is smaller than the predicted flexural strength which is calculated considering the loss of tendon area. It is considered that estimation of flexural strength of PSC beams with corroded tendons is very complicated just based on the loss of tendon area obtained by one-side visual inspection.

  • PDF

Feasibility Study of 2200MPa PS strand in terms of Wedge and Anchor Head (2200MPa급 PS강연선의 적용성 연구(쐐기와 앵커헤드))

  • Kim, Jin-Kook;Lee, Pil-Goo;Lee, Man-Seop
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.145-146
    • /
    • 2009
  • In this paper, feasibility tests of 2200MPa PS strand in terms of wedge and anchor head used currently for 1860MPa PS strand were performed. Static and fatigue tests for PT anchorage systems from 4 companies were conducted in compliance with ETAG013(European Technical Approval Guideline). The test results implied that some of them can be used for 2200MPa PS strand without improvement and some with small improvement.

  • PDF

Removal of Air Pollutants Using Photosensitizers/Photocatalysts (감광제/광촉매에 의한 공기오염물질 제거)

  • Park, Ju-Hyoung;Ahn, Ki-Chang;Lee, Jae-Koo
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.4
    • /
    • pp.284-293
    • /
    • 2000
  • For the artificial removal of air pollutants such as pesticides, environmental toxicants, and pathogenic microorganisms in the greenhouse or the living environment, the accelerated photodegradation and the biocidal effects of some photosensitizers (PS)/photocatalysts (PC) were tested under the sunlight and/or artificial light. The selected photosensitizers/photocatalysts included the semiconductors (PC-1 and PC-2), the oxidizers (PC-3, PC-4, PC-5 and PC-6), the aromatic ketone (PS-7) and the aromatic amine (PS-8). In the case of dichlorvos, all the photocatalysts selected showed more accelerated photodegradation than the control without photocatalysts under both the sunlight and artificial light. Whereas, only the photocatalyst PC-1 accelerated the degradation of methyl tert-butyl ether about 17 times more than the control under both the sunlight and artificial light. Procymidone was much more degraded by the photosensitizer PS-8 and the two photocatalysts (PC-1, PC-6) than by PS-7. In the preliminary experiments to diminish the population of the microorganisms in the air, the photocatalyst PC-1 added to the suspensions of Pseudomonas putida, Phytophthora capsici, and Salmonella typhimurium obviously inhibited the microbial growth under the artificial light. The photocatalyst PC-1 showed a bactericidal activity against Salmonella typhimurium spread on the nutrient broth agar medium. These results suggest that the photosensitizers/photocatalysis under the light can remove some air pollutants and hence they can be used to reduce the exposure of the workers in the horticultural facilities and/or the public in the environment to the harmful pollutants.

  • PDF

Increase of Growth on Cool Season Turfgrass by Foliar Application of Preparations of Turfgrass Fertilizer during Fall Season (잔디 비료 제형의 엽면 살포가 가을철 한지형 잔디의 생장 증대)

  • Koo, Jun Hwak;Heo, Hyug Jae;Kim, Yang Sun;Yun, Jeong Ho;Chang, Seog Won;Lee, Seong Jun;Chang, Taehyun
    • Weed & Turfgrass Science
    • /
    • v.3 no.1
    • /
    • pp.41-49
    • /
    • 2014
  • Four preparations of liquid turfgrass fertilizers were tested cool season turfgrasses during fall season. The preparations of PS-A, PS-B, PH-C and PH-D for commercial products were contained with essential nutrient elements, seaweed extract, amino acids, and humus substance. Growth and quality of creeping bentgrass (Agrostis palustris Huds cv. Penn-A1) and Kentucky bluegrass (Poa pratensis L.) mixture (Midnight 33%, Moonlight 33%, Prosperity 33%) were evaluated by normalized difference vegetation index (NDVI), root length and fresh weight, shoot density, turf color, and chlorophyll content. Three foliar sprays of 4 preparations with an interval of 7 days were made in the fall of 2013 in the sod production field at Hapchun, Korea. No significant difference among 3 preparations was found in NDVI of creeping bentgrass. However, PS-A was significantly increased NDVI of Kentucky bluegrass. Two to three applications of PS-A significantly increased chlorophyll content and turf color. Three foliar sprays of PS-A and PS-B were significantly increased the shoot density of Kentucky bluegrass on 20 days after final application. These results may indicate that the use of some preparation is beneficial in producing higher quality turfgrass sod with better color and chlorophyll content during fall season.

Clinical Study of Ventricular Septal Defect (심실중격결손의 임상적 고찰)

  • Kim, Gyu-Tae;Lee, Jong-Tae;Lee, Jae-Seong
    • Journal of Chest Surgery
    • /
    • v.18 no.2
    • /
    • pp.157-164
    • /
    • 1985
  • Our series comprised 68 patients of ventricular septal defect who underwent open heart surgery at the Department of Thoracic and Cardiovascular Surgery, School of Medicine, Kyungpook National University, from January, 1980 to September, 1984. Of the 68 patients, 47 patients were male [69.1%] and 21 patients were female [30.9%]. Their age ranged from 3 years to 27 years, and the mean age was 10.1 years. Upon Kirklin`s anatomical classification, type I constituted 29.4%, type II 69.1%, type III 1.5%, and type IV 1%. The cardiac anomalies associated with ventricular septal defect were 21 in all; 5 PS, 4 Aortic insufficiency, 2 ASD, 4 Patent foramen ovale, and 1 Patent ductus arteriosus. Upon the data of cardiac catheterization, most of the patients had Qp/Qs of 1.4-1.8, Pp/Ps of 0.25 or less and Rp/Rs of 0.25 or less. There was no significant correlationship between the rate of operative complication & mortality and the increase of Qp/Qs, Pp/Ps, and Rp/Rs. The values of Qp/Qs, Pp/Ps and Rp/Rs were correspondingly increased according to increment of the defect size. 20 patients developed postoperative complications, such as 4 acute respiratory failure, 3 reexploration due to massive bleeding, 1 low cardiac output, 1 patch detachment, and 2 air embolism. Operative mortality rate was 7.4% [5 cases] among 68 patients.

  • PDF