• 제목/요약/키워드: PR connection

검색결과 30건 처리시간 0.024초

Seismic response and energy dissipation in partially restrained and fully restrained steel frames: An analytical study

  • Reyes-Salazar, Alfredo;Haldar, Achintya
    • Steel and Composite Structures
    • /
    • 제1권4호
    • /
    • pp.459-480
    • /
    • 2001
  • The damage suffered by steel structures during the Northridge (1994) and Kobe (1995) earthquakes indicates that the fully restrained (FR) connections in steel frames did not behave as expected. Consequently, researchers began studying other possibilities, including making the connections more flexible, to reduce the risk of damage from seismic loading. Recent experimental and analytical investigations pointed out that the seismic response of steel frames with partially restrained (PR) connections might be superior to that of similar frames with FR connections since the energy dissipation at PR connections could be significant. This beneficial effect has not yet been fully quantified analytically. Thus, the dissipation of energy at PR connections needs to be considered in analytical evaluations, in addition to the dissipation of energy due to viscous damping and at plastic hinges (if they form). An algorithm is developed and verified by the authors to estimate the nonlinear time-domain dynamic response of steel frames with PR connections. The verified algorithm is then used to quantify the major sources of energy dissipation and their effect on the overall structural response in terms of the maximum base shear and the maximum top displacement. The results indicate that the dissipation of energy at PR connections is comparable to that dissipated by viscous damping and at plastic hinges. In general, the maximum total base shear significantly increases with an increase in the connection stiffness. On the other hand, the maximum top lateral displacement $U_{max}$ does not always increase as the connection stiffness decreases. Energy dissipation is considerably influenced by the stiffness of a connection, defined in terms of the T ratio, i.e., the ratio of the moment the connection would have to carry according to beam line theory (Disque 1964) and the fixed end moment of the girder. A connection with a T ratio of at least 0.9 is considered to be fully restrained. The energy dissipation behavior may be quite different for a frame with FR connections with a T ratio of 1.0 compared to when the T ratio is 0.9. Thus, for nonlinear seismic analysis, a T ratio of at least 0.9 should not be considered to be an FR connection. The study quantitatively confirms the general observations made in experimental results for frames with PR connections. Proper consideration of the PR connection stiffness and other dynamic properties are essential to predict dynamic behavior, no matter how difficult the analysis procedure becomes. Any simplified approach may need to be calibrated using this type of detailed analytical study.

Seismic response analysis of steel frames with post-Northridge connection

  • Mehrabian, Ali;Haldar, Achintya;Reyes-Salazar, Alfredo
    • Steel and Composite Structures
    • /
    • 제5권4호
    • /
    • pp.271-287
    • /
    • 2005
  • The seismic behavior of two steel moment-resisting frames, which satisfy all the current seismic design requirements, are evaluated and compared in the presence of pre-Northridge connections denoted as BWWF and an improved post-Northridge connections denoted as BWWF-AD. Pre-Northridge connections are modeled first as fully restrained (FR) type. Then they are considered to be partially restrained (PR) to model their behavior more realistically. The improved post-Northridge connections are modeled as PR type, as proposed by the authors. A sophisticated nonlinear time-domain finite element program developed by the authors is used for the response evaluation of the frames in terms of the overall rotation of the connections and the maximum drift. The frames are excited by ten recorded earthquake time histories. These time histories are then scaled up to produce some relevant response characteristics. The behaviors of the frames are studied comprehensively with the help of 120 analyses. Following important observations are made. The frames produced essentially similar rotation and drift for the connections modeled as FR type and PR type represented by BWWF-AD indicating that the presence of slots in the web of beams in BWWF-AD is not detrimental to the overall response behavior. When the lateral displacements of the frames are significantly large, the responses are improved if BWWF-AD type connections are used in the frames. This study analytically confirms many desirable features of BWWF-AD connections. PR frames have longer periods of vibration in comparison to FR frames and may attract lower inertia forces. However, calculated periods of the frames of this study using FEMA 350 empirical equation is longer than those calculated using dynamic characteristics of the frames. This may result in even lower design forces and may adversely influence the design.

Dissipation of energy in steel frames with PR connections

  • Reyes-Salazar, Alfredo;Haldar, Achintya
    • Structural Engineering and Mechanics
    • /
    • 제9권3호
    • /
    • pp.241-256
    • /
    • 2000
  • The major sources of energy dissipation in steel frames with partially restrained (PR) connections are evaluated. Available experimental results are used to verify the mathematical model used in this study. The verified model is then used to quantify the energy dissipation in PR connections due to hysteretic behavior, due to viscous damping and at plastic hinges if they are formed. Observations are made for two load conditions: a sinusoidal load applied at the top of the frame, and a sinusoidal ground acceleration applied at the base of the frame representing a seismic loading condition. This analytical study confirms the general behavior, observed during experimental investigations, that PR connections reduce the overall stiffness of frames, but add a major source of energy dissipation. As the connections become stiffer, the contribution of PR connections in dissipating energy becomes less significant. A connection with a T ratio (representing its stiffness) of at least 0.9 should not be considered as fully restrained as is commonly assumed, since the energy dissipation characteristics are different. The flexibility of PR connections alters the fundamental frequency of the frame. Depending on the situation, it may bring the frame closer to or further from the resonance condition. If the frame approaches the resonance condition, the effect of damping is expected to be very important. However, if the frame moves away from the resonance condition, the energy dissipation at the PR connections is expected to be significant with an increase in the deformation of the frame, particularly for low damping values. For low damping values, the dissipation of energy at plastic hinges is comparable to that due to viscous damping, and increases as the frame approaches failure. For the range of parameters considered in this study, the energy dissipations at the PR connections and at the plastic hinges are of the same order of magnitude. The study quantitatively confirms the general observations made in experimental investigations for steel frames with PR connections; however, proper consideration of the stiffness of PR connections and other dynamic properties is essential in predicting the dynamic behavior.

CFT 각형 기둥-보 합성 반강접 접합부의 단조가력 실험 (Monotonic Loading Test for CFT Square Column-to-Beam Partially Restrained Composite Connection)

  • 최성모;박수희;박영욱;김진호
    • 한국강구조학회 논문집
    • /
    • 제17권3호통권76호
    • /
    • pp.325-335
    • /
    • 2005
  • 본 연구의 목적은 CFT각형기둥과의 접합에 성능이 개선된 합성 반강접 접합디테일을 제안하고 기둥-보 접합부의 단조가력시 역학적 거동을 보기 위함이다. 극한 거동에 결정적 영향을 끼치는 하부 접합부의 전단내력을 보강하고 시공성을 고려하여 합성 반강접 접합을 CFT구조 형식에 시도하여 CFT기둥-보 접합부의 접합디테일을 제안하였다. 본 연구에서 제안하는 하부 보 플랜지 용접접합(M-2)을 기존 합성 반강접 접합상세인 시트앵글접합(M-1)과 비교/검토하였다. 두 개의 실대형 CFT기둥-보 합성 반강접 접합부 실험체에 대한 단조가력실험을 수행하였다. 실험 결과, 제안형인 하부 보플랜지 용접접합된 실험체는 강접합된 철골보의 약 85%의 강성을 확보하였다. 이는 기존형 실험체와 거의 동일하였으며, 반강접으로 분류됨을 확인할 수 있었다. 제안형 실험체가 웨브 접합부에서 볼트지압에 의한 전단파괴가 발생하였으나 파단 직전까지는 슬래브 연성파괴가 일어난 기존형 실험체와 유사한 거동을 보였다. 슬래브 보강근에 의해 충분한 강성 및 내력이 확보되며, 웨브부분의 강관내의 앵커보강에 의해 전소성모멘트에 상응하는 내력 및 변형성능이 확보되어 충분한 연성거동을 보이는 것으로 판단된다.

Stochastic finite element analysis of structural systems with partially restrained connections subjected to seismic loads

  • Cavdar, Ozlem;Bayraktar, Alemdar;Cavdar, Ahmet;Kartal, Murat Emre
    • Steel and Composite Structures
    • /
    • 제9권6호
    • /
    • pp.499-518
    • /
    • 2009
  • The present paper investigates the stochastic seismic responses of steel structure systems with Partially Restrained (PR) connections by using Perturbation based Stochastic Finite Element (PSFEM) method. A stiffness matrix formulation of steel systems with PR connections and PSFEM and MCS formulations of structural systems are given. Based on the formulations, a computer program in FORTRAN language has been developed, and stochastic seismic analyses of steel frame and bridge systems have been performed for different types of connections. The connection parameters, material and geometrical properties are assumed to be random variables in the analyses. The Kocaeli earthquake occurred in 1999 is considered as a ground motion. The connection parameters, material and geometrical properties are considered to be random variables. The efficiency and accuracy of the proposed SFEM algorithm are validated by comparison with results of Monte Carlo simulation (MCS) method.

Effect of Pr substitution on the normal-state and superconducting properties of GdBa$_2$(Cu$_{2.9}$Al$_{0.1}$)O$_z$

  • Park, Jung-Rok;Ha, Dong-Han;Lee, Ho-Keum
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.70-75
    • /
    • 2000
  • We report results of a comparative study of the normal-state and superconducting properties in the GdBa$_2$(Cu$_{2.9}$Al$_{0.1}$)O$_z$ system with substitutions by Pr for the Gd and Ba sites. It is observed that, fur both Pr-doped systems, the superconducting transition temperature(T$_c$) decreases almost linearly with the Pr-content, but Pr at Ba sites results in a faster T$_c$ drop than that of Pr at Gd sites. The thermoelectric power measurements indicate that there is a strong correlation between the T$_c$ and the room temperature value of thermoelectric power. The experimental results are discussed in connection with existing models.

  • PDF

Effect of Pr substitution on the superconducting properties of (Pb0.5Cd0.5)SrLaCuOz

  • Lee, H.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권3호
    • /
    • pp.5-8
    • /
    • 2015
  • The effects of Pr substitution on the structural and the superconducting properties for Pb-based 1201 cuprates with compositions of $(Pb_{0.5-x}Pr_xCd_{0.5})SrLaCuO_z(0{\leq}x{\leq}0.25)$ and $(Pb_{0.45}Pr_{0.05}Cd_{0.5})(Sr_{1-y}La_{1+y})CuO_z(0{\leq}y{\leq}0.1)$ were investigated. It is found that $T_c$ decreases as the Pr-doping content x increases in the $(Pb_{0.5-x}Pr_xCd_{0.5})SrLaCuO_z$ samples, whereas $T_c$ of $(Pb_{0.45}Pr_{0.05}Cd_{0.5})(Sr_{1-y}La_{1+y})CuO_z$ samples increases as the La-doping content y increases. The experimental results were discussed in connection with the change in hole concentration of the samples.

스마트 반강접 (PR) 콘크리트 충전 강재 합성 (CFT) 접합 구조물에 대한 해석모델의 개발 (Development of A Component and Advanced Model for The Smart PR-CFT Connection Structure)

  • 선우현;허종완
    • 복합신소재구조학회 논문집
    • /
    • 제2권4호
    • /
    • pp.1-10
    • /
    • 2011
  • 본 연구는 각 연결부에 대한 수치 해석을 통하여 강재-콘크리트 합성 프레임 구조물의 성능을 조사하였다. 본 연구의 혁신적인 측면은 강재 보와 CFT 기둥의 연결부 사용과 저탄소강과 형상 기억 합금 구성요소의 조합을 활용하는데 있다. 이러한 새로운 연결부의 목적은 지진 후 건물의 손상과 잔류 흐름을 줄이기 위해 고탄성 형상기억합금 인장부에서 발생하는 교정 작용과 저탄소강의 우수한 에너지 분산 능력을 활용하는 것이다. 연결부의 핀, 전체적인 고정 또는 부분 구속으로 모델링을 할 수 없기 때문에 이러한 구조물들의 해석과 설계는 복잡하여 PR-CFT 연결부의 전체적인 거동을 알기 위한 수치해석을 위해 정교한 3차원 솔리드 요소로 구성된 유한해석 모델을 개발하였다. 이러한 유한요소 해석으로 얻은 결과를 바탕으로 스프링 요소를 이용하여 간단한 연결부 모델링을 공식화 시켰다. 반복 하중을 가하여 전체 프레임 구조물의 거동을 확인하였고 3D 유한요소 해석을 통하여 단순 거동을 비교하였다.

Effects of Divalent Cation Incorporation on the Emission Characteristics of $Srln_2O_4:Pr^{3+}$ Phosphors

  • Kang, Seung-Youl;Kang, Seong-Gu;Lee, Yong-Eui;Ahn, Seong-Doek;Suh, Kyung-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.1024-1027
    • /
    • 2002
  • In this study, we have investigated the substitutional effects of In ions with divalent ones in the $Srln_2O_4:Pr^{3+}$ phosphors and the relative change of the red and blue emissions. The substitutional Zn ions greatly intensified the blue emission band at 492 nm, but the red emission band at 608 nm was relatively less changed. On the other hand, Cd ions have no effect on the relative intensities. We explained the phenomena in connection with the distance of Pr-D, i.e., covalency experienced by a $Pr^{3+}$ion.

  • PDF

비선형 부하 연결시 마이크로그리드 인버터의 고조파 보상을 위한 출력 전압 제어 방식 (Inverter Output Voltage Regulation for harmonic compensation with non-linear load connection)

  • 임경배;최재호;장주영;문상호;김재식
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.552-553
    • /
    • 2014
  • 본 논문은 인버터 독립운전모드에서의 출력 전압 제어 방식을 다루고있다. 본 논문은 계통 연계 모드와 독립 운전 모드간의 모드 절환이 가능한 계통 연계형 인버터 출력단에 비선형 불평형 부하 연결시 발생하는 출력전압 왜곡현상에 대처하기위해 기존에 주로 사용되는 PI 제어를 이용한 방식을 대신해 고정좌 좌표계 또는 abc natural 프레임 하에서 사용되는 PR 제어를 사용하여 고조파 보상을 수행하였으며 추가적으로 계통 연계 모드시 외부 PR 출력 전류 루프와 내부 PR 출력 전압 루프를 가지는 제어기를 제안하였고 이러한 제어 방식이 계통 연계 모드의 출력 전압 THD 성능개선에 효과적임과 동시에 또한 모드 변환시의 동특성을 좀더 개선할 수 있다는 점을 입증하였다.

  • PDF