• Title/Summary/Keyword: PPT(Pulse Transit Time)

Search Result 4, Processing Time 0.026 seconds

Estimation of Non- Invasive Blood Pressure Using Peripheral Plethysmograph (말초혈관 혈류 측정을 이용한 비관혈적 혈압 추정법에 대한 연구)

  • Jeong In-cheol;Shin Tae-min;Yoon Hyung-Ro
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.8
    • /
    • pp.504-509
    • /
    • 2005
  • This paper presents a new method for obtaining the noninvasive and unrestrained blood pressure readings noninvasively and unrestrainedly using based on reflected wave arrival time(RAT) in the volume of pulse. Since this new method employs only volume pulse, is more rapider and simpler than the method using pulse transit time(PTT) because it only employs the volume of pulse. Blood pressure, PTT and RAT were acquired from 15 healthy subjects. Each subjects were performed forty trials of each measurement. As a result of those trials, the mean error between oscillometric and RAT measurements for systolic blood pressure was $4.55\pm5.64mmHg$. This result showed quite equal with the mean error between oscillometric and PPT measurf:ments, $4.22\pm5.30mmHg$, However, it was not obtained a satisfactory result in the relativity of oscillometric to both RAT and PPT measurements for diastolic blood pressure because of personal difference. To conclude, the method of systolic blood pressure estimation noninvasively and unrestrainedly using by RAT may be used as the method by PTT. Nevertheless, additional studies would be necessary for the RAT/PTT estimation of diastolic blood Pressure measurement.

Analysis of Relations Between Physiologic Parameters and Pulse Transit Time on the Ultrasound Therapy (초음파 재활치료 시 PTT와 생리변수의 상관관계 분석)

  • Kim, Sung-Min;Choi, Sang-Hyuk;Lee, Man-Pyo;Choi, Byeong-Cheol;Jung, Whoi-Seong;Park, Sung-Yoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1514-1520
    • /
    • 2007
  • Currently, the signal of the human body is measured with various methods, and a noninvasive investigation of various methods is useful diagnosis method. PTT(Pulse Transit Time) which is noninvasive investigation make use of to estimate the physiological phenomena. PTT has a latent information of cardiovascular system. So we have the experiments for analysis of the relations between PTT and physiological parameters. We examine to correlate to the physiological parameters, an age and degree of paralysis on the ultrasound therapy. The 40 patients who has a such paralysis join our experiment, and we obtain the PTT data that normal condition and states after ultrasound therapy. We study that PTT after the ultrasound therapy for patients who have a paralysis was related to an age and degree of paralysis.

Development of continuous blood pressure measurement system using ECG and PPG (ECG와 PPG를 이용한 실시간 연속 혈압 측정 시스템)

  • Kim, Jong-Hwa;Whang, Min-Cheol;Nam, Ki-Chang
    • Science of Emotion and Sensibility
    • /
    • v.11 no.2
    • /
    • pp.235-244
    • /
    • 2008
  • This study is to develop automatic extraction system of continuous blood pressure using ECG (Electrocardiogram) and PPG(Photoplethysmography) for u-health care technology. PTT (Pulse Transit Time) was determined from peak difference between ECG and PPG and its inverse made to get blood pressure. Since the peaks were vulnerable to be contaminated from noise and variation of amplitude, this study developed the adaptive algorithm for peak calculation in any noise condition. The developed method of the adaptive peak calculation was proven to make the standard deviations of PPT decrease to 28% and the detection of noise increase to 18%. Also, the correlation model such as blood pressure = -0.044 $\cdot$ PTT + 133.592 has successfully been determined for predicting the continuous pressure measured without using cuff but with using PPG and ECG, only.

  • PDF

Relationship between HsCRP and Pulse Transit Time (HsCRP와 맥파전달시간에 대한 연구)

  • Kim, Yun-Jin;Min, Hong-Gi;Kim, Young-Joo;Jeon, Ah-Young;Jeon, Gye-Rok;Ye, Soo-Young
    • Journal of Life Science
    • /
    • v.17 no.2 s.82
    • /
    • pp.218-222
    • /
    • 2007
  • The purpose of this study is to evaluate the relationship between high sensitive C-reactive protein (hsCRP) and pulse transit time (PPT). Apparently healthy 233 subjects had been enrolled in the health promotion center of the Pusan National University Hospital from Jan. 29 to Feb. 26, 2004. They had no previous history of diabetes, hypertension and hyperlipidemia. Subjects were categorized according to tertiles of hsCRP level [Group 1: first tertile $(0.01\;{\sim}\;0.02\;mg/dl)$, Group 2: second tertile $(0.03\;{\sim}\;0.05\;mg/dl)$, Group 3: third tertile $(0.06\;{\sim}\;0.12\;mg/dl)$, and Group 4: Fourth tertile $(0.13\;{\sim}\;16.8\;mg/dl)$]. PTT body mass index (BMI), total cholesterol (T-C), LDL-cholesterol(LDL-C), blood sugar (BS), systolic blood pressure (sBP) and diastolic blood pressure (dBP) were significantly different among hsCRP groups (p<0.05). HsCRP is positively related with BMI, tryglyceride (TG), LDL, sBP and dBP (p<0.05), and negatively related with PTT and HDL-cholesterol (HDL-C) (p<0.05). PTT is significantly negatively related with hsCRP, T-C, TG, LDL-C, BS, dBP and sBP (p<0.05). The hsCRP and PTT were related before controlling BMI, T-C, LDL-C, sBP, and dBP, but not related after conkolling. The relationship between hsCRP and PTT depends on cardiovascular disease risk factors.