• Title/Summary/Keyword: PPS(Pulse Per Second)

Search Result 18, Processing Time 0.026 seconds

Development of high repetition rate and high power pulsed Nd:YAG laser power supply using ZCS resonant converter (ZCS공진형 컨버터를 적용한 고반복 대출력 펄스형 Nd:YAG 레이저 전원장치 개발)

  • Joe, K.Y.;Kim, E.S.;Byun, Y.B.;Kim, H.J.;Park, J.M.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.514-517
    • /
    • 1996
  • Zero current switching(ZCS) series resonant converter is used to control laser power density in a pulsed Nd:YAG laser power supply. The high power and high repetition rate paused Nd:YAG laser is designed and fabricated to control current pulse width and pulse repetition rate in the double elliptical laser oscillator. In order to find out operational characteristics of pulsed Nd:YAG laser, the electrical properties of driving power supply and laser output power are investigated and experimented by changing of the current pulse width from 200uS to 350uS(step 50uS) and pulse repetition rate range of 500pps(pulse per second) to 1150pps. From that result, we obtaind maximum efficiency of 1.83% and maximum laser output or 220W at the condition of 350 uS and 1150pps with one Nd:YAG rod), and obtained that of more than 400W with two laser head connecting series.

  • PDF

The Repetition rate and Pulse-width control of Nd:YAG laser using One-Chip Microprocessor (One-Chip 마이크로프로세서를 이용한 Nd:YAG 레이저의 반복율 및 펄스폭제어)

  • Hong, J.H.;Chung, Y.H.;Yang, D.M.;Kim, W.Y.;Kim, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1696-1698
    • /
    • 1998
  • Pulsed Nd:YAG laser using Nd:YAG crystal operates stably in the thermal conductivity, mechanical, optical condition. That is used broadly in material processings because of easy reaction to the materials, and the maintenance is very easy because of lamp excitation. In these material processings, power dinsity control is very important to improve processing technology. Power density is controled by inductance and capacitance or repetition rate. Therefore we are going to control laser power density as One-Chip Microprocessor(PIC16C55) and 8051. We have been experimented at the pulse repetition rate range of 10pps to 60pps(pulse per second).

  • PDF

Development and Observation Result of High Speed Digital Conversion System of Astronomical Radio Siginal (우주 전파 신호의 고속 디지털 변환 장치 개발과 적용)

  • Kang, Yong-Woo;Song, Min-Gyu;Wi, Seog-Oh;Je, Do-Heung;Lee, Sung-Mo;Kim, Seung-Rae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.6
    • /
    • pp.1009-1018
    • /
    • 2017
  • We developed new Digital Sampler for KVN(: Korean VLBI Network). The sampler has 1024MHz sampling frequency with 2bits/sample. The sampler's input reference frequencies are 1pps(: pulse per second) and 10MHz, also UTC(: Universal Time Coordinated) time information out with 1PPS signal, synchronized. The output of sampling data is adapted VSI(: VLBI Standard Interface) specification including the time information. In order to confirm the performance of the sampler, we carried out the astronomical radio observation test in Ulsan Radio Observatory of KVN. It was confirmed the stable performance. In this paper, We introduce the new developed sampler and present the observational test result.

TDoA-Based Practical Localization Using Precision Time-Synchronization (정밀 시각동기를 이용한 TDoA 기반의 위치 탐지)

  • Kim, Jae-Wan;Eom, Doo-Seop
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.2
    • /
    • pp.141-154
    • /
    • 2013
  • The technology of precise time-synchronization between signal receive devices for separation distance operation can be a key point for the technology with TDoA-based system. We propose a new method for the higher accuracy of system's time-synchronization in this paper, which uses OCXO and DPLL with high accuracy to achieve phase synchronization at 1 pps (pulse per second) of signal. And the method receive time value from a GPS satellite. Essentially, the performance of GPS with high accuracy refers to long-term frequency stability for its reliability. As per the characteristic, as the GPS timing signals are synchronized continuously, the accuracy of time-synchronization gets improved proportionally. Therefore, if the time synchronization is accomplished, the accuracy of the synchronization can be up to 0.001 ppb (part per billion). Through the improved accuracy of the time-synchronization, the measurement error of TDOA-based location detection technology is evaluated. Consequently, we verify that TDoA-based location measurement error can be greatly improved via using the improved method for time-synchronization error.

The Time Synchronization Signals of the GNSS Receiver for KSLV-II and Their Performance Assessment (한국형발사체 위성항법수신기의 시각동기신호 생성 및 성능 평가)

  • Kwon, Byung-Moon;Shin, Yong-Sul;Ma, Keun-Su;Yun, Kwang-Ho;Seo, Hung-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.11
    • /
    • pp.812-820
    • /
    • 2019
  • The GNSS receiver for KSLV(Korea Space Launch Vehicle)-II provides real-time navigation data as well as precise time and time interval. The precise time signals provided by the GNSS receiver that can be used for the time synchronization between onboard systems, and between the onboard systems and ground stations have the forms of the 1PPS(One Pulse Per Second) and IRIG-B(Inter-Range Instrumentation Group Time Code B) which are synchronized with UTC(Coordinated Universal Time). A signal for timing faults also informs whether the time synchronization signals are available or not. This paper describes the time synchronization signals of the GNSS receiver for KSLV-II and their performance assessment.

Research on the Multi - purpose Nd:YAG Laser Power System using LLC Converter (LLC 공진형 컨버터를 사용한 다용도 Nd:YAG 레이저 전원장치 설계)

  • Zheng, Tao;Kim, Hee-Je;Lee, Jae-cheol;Xu, Guo-Cheng
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.6
    • /
    • pp.885-890
    • /
    • 2015
  • LLC resonant converter has been widely used because of its high efficiency and high energy density. In this paper, we designed a LLC resonant converter as the main power supply of the Nd:YAG pulse laser. First harmonic approximation (FHA) is used to model the LLC resonant converter. FHA equivalent circuit model and the transfer function of the LLC resonant converter is proposed. Soft start technology is also used to suppress the surge current. The laser output simulation test result is identical with the practical test, the laser energy of every pulse can reach up to 2.5J, and the pulse per second (PPS) can be adjusted from 6 to 18. The power system is verified stable and reliable by both of the simulation and experiment results.

The Research via Linear of Tantalum Thin Film Thickness Depending on Revolution Velocity of Spin Coater (스핀코터 회전속도에 따른 탄탈륨 박막두께의 선형모델에 관한 연구)

  • Kim, Seung Wook
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.1
    • /
    • pp.17-22
    • /
    • 2020
  • Recently, the decrease in thin film thickness has been actively studied by changing several physical elements such as the increase in revolution velocity of lower substrate equipped with AC or DC motor. In this paper, we propose a novel spin coater control system that changes AC or DC motor and common use software with limitation of velocity and position control into step motor and LABVIEW software based on GUI to control revolution velocity and position more precisely. By determining six input values of rotation velocity 1, 5, 10, 25, 50, 100 PPS, we fabricated six samples using coating target, TA(tantalum) on silicon substrate and measured their thin film thickness by SEM. Hence, this research can be applied to inferring thin film thickness of tantalum regarding any value of revolution velocity without additional experiments and for linear reference model via property analysis of thin film thickness using other thin-film materials.

Lasing Effects on the Dorsal Tongue Mucosa of Adult Rats by Pulsed Nd:YAG Laser (펄스식 Nd:YAG 레이저 조사에 따른 성체 흰주 혀배면 점막의 변화)

  • Jung-Ho Choi
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.1
    • /
    • pp.183-196
    • /
    • 1996
  • The author examined the clinical and histological changes on the dorsal tongue mucosa of adult Sprague-Dawley rats after lasing by pulsed Nd:YAG laser. The dorsal tongue was lased for 3 seconds by 1.5, 2.0, 2.5, 3.0, 3.5, 4.0W and 10, 15, 20, 20pps. After tissue changes were observed clinically, the excised samples were observed histologically and the width of tissue destruction was analyzed quantitatively under the Confocal laser microscope respectively. The following results were obtained : 1. Whitening of peripheral tissue was observed more as increasing pulsed per second (Hz) below power 2.5W and observed at all parameters above power 3.0W. 2. Charring of mucosal surface was observed at all parameters but mild at parameters below power 2.0W. 3. The destruction of epithelium was observed at all parameters and tissue destruction was extended to lamina propria at higher pulses per second. 4. The width of tissue destruction was more widening as increasing energies per pulse (p<0.001) and the narrowest at 20Hz than 10Hz, 15Hz and 30Hz(p<0.05). As the above results, author suggests power below-3.5W and 20Hz as the lasing parameters for oral soft tissue therapy.

  • PDF

Wireless Water Leak Detection System Using Sensor Networks (센서네트워크를 이용한 무선 누수 탐지 시스템)

  • Choi, Soo-Hwan;Eom, Doo-Seop
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.3
    • /
    • pp.125-131
    • /
    • 2011
  • Water leak detection system is a system based on wireless sensor networks(WSNs) which detect a leak on water supply, localize the leak position and finally inform a water management center. A traditional leak detection method is to use experienced personnel who walk along a pipeline listening to the sound that is generated by the leaks and their effectiveness depend on the experience of the user. Also making more successful detection, it should be processed at middle of the night when people do not use water, as the result users have to operate the leak detection system at midnight. In this paper, we propose a new method for the water leak detection system based on the WSNs and describe it in detail. Leak detection devices which detect a leakage of water transmit and receive the result of water leak detection with each other by configuring WSNs to improve reliability of the detection result. Also, we analyzed the sound from water flowed in pipeline, proposed the pre-signal processing to separate a leakage sound from noisy sound. And lastly, It is especially important to make a time synchronization with water leak detection devices that are installed on the pipeline, we used 1PPS(1 Pulse Per Second) signal generated by GPS, therefore we could get a precise time synchronization. The proposed system set up in Namyangju and performances were evaluated.

Sterilization of Escherichia coli Based on Nd: YAG Resonator with a Pulsed Xenon Flashlamp

  • Kim, Hee-Je;Kim, Dong-Jo;Hong, Ji-Tae;Xu, Guo-Cheng;Lee, Dong-Gil
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.275-279
    • /
    • 2011
  • Sterilization of Escherichia coli (E. coli) is examined using a unique pulsed ultra-violet (UV) elliptical reactor based on Nd:YAG laser resonator, UV radiation from a pulsed xenon flashlamp. The light from the discharge has a broadband emission spectrum extending from the UV to the infrared region with a rich UV contained. Sterilization method by using the UV light is fast, environment-friendly and it does not cause secondary pollution. A Nd:YAG laser resonator having elliptical shape has advantage of concentrating the radiation of the UV light at two foci as the quart sleeve filled with E. coli. The primary objective of this research is to determine the important parameters such as pulse per second (pps), the applied voltage for sterilizing E. coli by using an UV elliptical reactor. From the experiment result, the sterilization effect of UV elliptical reactor is better than that of UV cylindrical reactor, and it can be 99.9% of sterilization at 800V regardless of the pps within 10 minutes.