• Title/Summary/Keyword: PPS

Search Result 401, Processing Time 0.022 seconds

Morphology and Thermal Properties of PPS/ABS Blends (PPS/ABS 블렌드의 형태학적/열적 특성)

  • 이영관;김준명;남재도;박찬석;장승필
    • Polymer(Korea)
    • /
    • v.24 no.3
    • /
    • pp.366-373
    • /
    • 2000
  • In this study, the PPS/ABS blend system was investigated in order to collectively identify the relationship among blend morphology, chemical compatibilization and thermal property. ABS resin was chemically modified by the incorporation of maleic anhydride through reactive extrusion for enhanced compatibilization, and PPS, ABS and the modified ABS were blend by a sing twin screw extruder. The effect of chemical modification of ABS on the morphological, mechanical, and thermal properities of the resulting blend was examined. A strong interaction was observed between PPS and MABS by optical microsopy as well as scanning electron microscopy, exhibiting a well-dispersed morphological feature. The PPS/MABS blend showing a single glass transition temperature was observed in dynamic mechanical analysis, demonstrating a pseudo-homogeneous phase morphology induced by chemical compatibilization. PPS/MABS blend also exhibited an enhanced thermal stability and heat distortion temperature compared with modified PPS/ABS blend.

  • PDF

Change in Palliative Performance Scale (PPS) Predicts Survival in Patients with Terminal Cancer

  • Oh, Jee Hye;Lee, Yong Joo;Seo, Min Seok;Yoon, Jo Hi;Kim, Chul Min;Kang, Chung
    • Journal of Hospice and Palliative Care
    • /
    • v.20 no.4
    • /
    • pp.235-241
    • /
    • 2017
  • Purpose: The Palliative Performance Scale (PPS) is a widely used prognostic tool in patients with advanced cancer. This study examines the association between changes in PPS score and survival in patients with advanced cancer. Methods: We identified a cohort of 606 inpatients who died at a Korean university hospital's hospice/palliative care center. For each patient, the PPS score was measured twice according to a standard procedure: 1) upon admission, and 2) three days after admission (D3). "Change on D3" was defined as a difference between initial PPS and PPS on D3. We used a Cox regression modeling approach to explore the association between this score change and survival. Results: The changes in scores were associated with survival. A score change of >30% yielded a hazard ratio for death of 2.66 (95% CI 2.19~3.22), compared to a score change of ${\leq}30%$. PPS of ${\leq}30$ on D3 also independently predicted survival, with a hazard ratio of 1.67 (95% CI 1.38~2.02) compared to PPS of >30. Conclusion: A change of over 30% in PPS appears to predict survival in hospitalized patients with terminal cancer, even after adjustment for confounders. Changes in PPS may be a more sensitive indicator of impending death than a single PPS measured on the day of admission in terminal cancer patients. Further prospective study is needed to examine this important finding in other populations.

Mathematical Analysis of the Parallel Packet Switch with a Sliding Window Scheme

  • Liu, Chia-Lung;Wu, Chin-Chi;Lin, Woei
    • Journal of Communications and Networks
    • /
    • v.9 no.3
    • /
    • pp.330-341
    • /
    • 2007
  • This work analyzes the performance of the parallel packet switch (PPS) with a sliding window (SW) method. The PPS involves numerous packet switches that operate independently and in parallel. The conventional PPS dispatch algorithm adopts a round robin (RR) method. The class of PPS is characterized by deployment of parallel low-speed switches whose all memory buffers run more slowly than the external line rate. In this work, a novel SW packet switching method for PPS, called SW-PPS, is proposed. The SW-PPS employs memory space more effectively than the existing PPS using RR algorithm. Under identical Bernoulli and bursty data traffic, the SW-PPS provided significantly improved performance when compared to PPS with RR method. Moreover, this investigation presents a novel mathematical analytical model to evaluate the performance of the PPS using RR and SW method. Under various operating conditions, our proposed model and analysis successfully exhibit these performance characteristics including throughput, cell delay, and cell drop rate.

Synthesis and Thermal Properties of PPS/PPSS Copolymer (PPS/PPSS 공중합체의 합성 및 열적 성질)

  • Park, Lee-Soon;Lee, Tae-Hyung;Kwak, Kyu-Dae;Haw, Jung-Rim
    • Applied Chemistry for Engineering
    • /
    • v.9 no.3
    • /
    • pp.440-444
    • /
    • 1998
  • Poly(phenylene sulfide-co-phenylene sulfide sulfone), PPS/PPSS copolymers were synthesized from p-dichlobenzene(DCB), p-dibromobenzene(DBB), p-diiodobenzene(DIB), 4-chlorophenyl sulfone(CPS) and sodium sulfide as comonomers under high temperature and pressure utilizing N-methyl-2-pyrrolidinone(NMP) as solvent. The yield of PPS/PPSS copolymer shoed maximum at $190^{\circ}C$ with [DBB]/[CPS] and [DIB]/[CPS] comonomer pair, while [DCB]/[CPS] pair exhibited maximum yield at $230^{\circ}C$. The change of yield is in the order of I>Br>Cl as leaving groups were in accordance with nucleophilic aromatic substitution reaction mechanism suggested for the synthesis of PPS type polymers. The molecular weight of PPS/PPSS copolymer was the highest($M_w=8,330g/mol$) with [DBB]/[CPS] comonomers in which [CPS] was 10 mole%. The PPS/PPSS copolymer made with 10 mole% of [CPS] showed about $15^{\circ}C$ higher $T_g$ and $15^{\circ}C$ lower $T_m$ than those of PPS homopolymer, which may be useful from the processing and thermal property point of view. The PPS/PPSS copolymer with 30 mole% of CPS or above did not exhibit Tm. The PPS/PPSS copolymer obtained with comonomer feed ratio of [DBB]/[CPS] = 95/5 mole% under $240^{\circ}C$ showed even higher molecular weight($M_w=10,300g/mole$) than PPS homopolymer made under similar reaction condition, retaining high crystallinity and thermal stability.

  • PDF

Compatibilization of Linear PPS/PET Blends with SEBS Copolymers (SEBS 공중합체를 이용한 선형 PPS/PET 블렌드의 상용화)

  • Kim, Sungki;Hong, In-Kwon;Lee, Sangmook
    • Polymer(Korea)
    • /
    • v.37 no.3
    • /
    • pp.405-410
    • /
    • 2013
  • The effect of styrene-ethylene/butylene-styrene (SEBS) on the blend of polyphenylene sulfide (PPS) and polyethylene terephthalate (PET) was investigated. The blends were extruded by a single screw extruder equipped with a Maddock mixing screw, and their molded properties were examined. After the binary blends were prepared on the whole compositions of PPS/PET (80/20, 60/40, 40/60, 20/80), the thermal, rheological, mechanical properties and morphology of the blends were analyzed. The results showed the significant decline in the properties of the blends owing to the incompatibility between PPS and PET phases. As a basic blend composition, the PPS/PET (40/60) blend was selected by considering cost efficiency. To this basic blend, SEBS was added as a compatibilizer. With increasing SEBS addition, the mechanical properties were improved. From the domain size reduction observed in morphology, it might be due to the enhancement of compatibility between linear PPS and PET phases by addition of SEBS.

ORTHODONTIC BRACKET SHEAR BOND STRENGTH TO Nd:YAG LASER Er:YAG LASER IRRADIATED ENAMEL (Nd : YAG 및 Er : YAG 레이저로 치아표면 조사시 브라켓 전단접착강도에 관한 실험적 연구)

  • Choi, Seung-Hoon;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.141-155
    • /
    • 1997
  • The purpose of this study was to evaluate the effectiveness of the Nd:YAG laser and the Er:YAAG laser on etching enamel for direct bonding of orthodontic bracket. The advantages of laser etching rather than conventional acid etching are to reduce the subsurface demineralization rate, to inhibit the spillage of acid onto uninvolved ""its of enamel, and to save the clinical manipulation time involving drying, trashing and drying again. 189 freshly extracted human premolars were prepared for this research. 165 out of them were divided into 11 groups of 15 teeth. One group was acid etching and the rest groups were irradiated with Nd:YAG laser by four different energy levels(100mj 10pps, 100mj 20pps, 150mj 20pps, 200mj 20pps) and with Er:YAG laser by six different energy levels(60mj 5pps, 60mj 10pps, 100mj 10pps. 200mj 10pps, 200mj l5pps, 400mj 10pps). Shear bond strength was tested with Instron after 24 hours, one week, and three weeks. Twenty-four out of 189 teeth were divided into twelve groups untreated control, acid etching, and ten laser irradiation subgroups. And the ultrastructural enamel surfaces of each group were observed with scanning electron microscope. The results were as follows; 1. The means and the standard deviations of shear bond strength of Nd:YAG and Er:YAU laser irradiation by different energy levels were obtained. 2. Shear bond strengths of Er:YAG laser irradiation groups were higher than those of Nd:YAG laser irradiation groups at the identical energy level. 3. Maximum bond strengths was achieved at the energy of I50mj, 20pps in Nd:YAG laser irradiation groups or 60mj, 10pps in Er:YAG laser irradiation groups. 4. It was acceptible for direct bonding to irradiate lb0mj 20pps with Nd:YAG laser or to irradiate 60mj 10pps with Er:YAG laser considering the results of shear bond strength tests and SEM obsesvation.

  • PDF

Influences of Perceived Treatment Effect and Perceived Physical Suffering on Hope of Cancer Patients in Post-operative Period (치료 효과 감지정도와 신체적 고통 감지정도가 수술직후 암환자의 희망에 미치는 영향)

  • Ahn, Seong-Yoon;Kim, Dal-Sook
    • Korean Journal of Adult Nursing
    • /
    • v.15 no.1
    • /
    • pp.78-87
    • /
    • 2003
  • Purpose: The purposes of the study were 1) to examine what relationships exist between PTE(perceived treatments effect) and PPS (perceived physical suffering) as the independent variables and hope as the dependent variable and 2) to examine whether PTE and PPS predict hope in cancer patients in their post-operative period within the Stotland's hope theory. Method: The Visual Analog Scale was used for measuring PTE and PPS and the Kim & Lee's Hope Scale which had acceptable reliability and validity was used for measuring hope. The data was collected from 38 hospitalized cancer patients who were in the post-operative period with a convenient sampling method. Result: There was a significant positive relationship between hope and the PTE in the low PTE group. There was a significant negative relationship between hope and the PPS in the low PPS group. There were no significant relationships between hope and the PTE in the high PTE group, and between hope and the PPS in the high PPS group. And the PTE explained hope with 71.2% of the variance in the low PTE group. Conclusion: PTE in the low PTE group and PPS in the low PPS group were identified as the factors to explain hope.

  • PDF

Effects on the ESD Protection Performance of PPS(PMOS Pass Structure) Embedded N-type Silicon Controlled Rectifier Device with different Partial P-Well Structure (PPS 소자가 삽입된 N형 SCR 소자에서 부분웰 구조가 정전기 보호 성능에 미치는 영향)

  • Yang, Jun-Won;Seo, Yong-Jin
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.4
    • /
    • pp.63-68
    • /
    • 2014
  • Electrostatic Discharge(ESD) protection performance of PPS(PMOS pass structure) embedded N-type silicon controlled rectifier(NSCR_PPS) device with different partial p-well(PPW) structure was discussed for high voltage I/O applications. A conventional NSCR_PPS standard device shows typical SCR-like characteristics with low on-resistance, low snapback holding voltage and low thermal breakdown voltage, which may cause latch-up problem during normal operation. However, our proposed NSCR_PPS devices with modified PPW demonstrate the stable ESD protection performance with high latch-up immunity.

The Properties of Electrical Conduction and Photoconduction in polyphenylene Sulfide(PPS) by Uniaxal Elongation (일축연신에 따른 Polyphenylene Sulfide(PPS)의 전기전도 및 광전도 특성)

  • Lee, Un-Yong;Jang, Dong-Uk;Shin, Tae-Su;Lim, kee-Joe;Ryu, Boo-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.10
    • /
    • pp.763-767
    • /
    • 1998
  • In this paper, it is investigated how the morphology and electrical properties in Polyphenylene Sulfide(PPS) changed by uniaxial elongation. XRD(X-ray diffraction) pattern shows that interplanar distance and crystallinities are decreased by increasing elongation ratio. electrical conduction mechanism of PPS is explained as Schottky emission mechanism. the electrical current is decreased by increasing elongation ratio. The conductivity is changed considerably above the glass transition temperature around 82(>$^{\circ}C$). The band gap of PPS is evaluated as 3.7~4(eV)

  • PDF

Evaluation on the Accuracy of the PPS in the Proton Therapy System, Which Uses the Self Made QA Phantom (자체 제작한 QA Phantom을 이용한 양성자 PPS (Patient Positioning System)의 정확성 평가)

  • Lee, Ji-Eun;Kim, Jae-Won;Kang, Dong-Yoon;Choi, Jae-Hyeok;Yeom, Du-Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.115-121
    • /
    • 2012
  • Purpose: The process of the proton treatment is done by comparing the DRR and DIPS anatomic structure to find the correction factor and use the PPS to use this factor in the treatment. For the accuracy of the patient set up, the PPS uses a 6 axis system to move. Therefore, there needs to be an evaluation for the accuracy between the PPS moving materialization and DIPS correction factor. In order to do this, we will use a self made PPS QA Phantom to measure the accuracy of the PPS. Materials and Methods: We set up a PPS QA Phantom at the center to which a lead marker is attached, which will act instead of the patient anatomic structure. We will use random values to create the 6 axis motions and move the PPS QA Phantom. Then we attain a DIPS image and compare with the DRR image in order to evaluate the accuracy of the correction factor. Results: The average correction factor, after moving the PPS QA Phantom's X, Y, Z axis coordinates together from 1~5 cm, 1 cm at a time, and coming back to the center, are 0.04 cm, 0.026 cm, 0.022 cm, $0.22^{\circ}$, $0.24^{\circ}$, $0^{\circ}$ on the PPS 6 axis. The average correction rate when moving the 6way movement coordinates all from 1 to 2 were 0.06 cm, 0.01 cm, 0.02 cm, $0.1^{\circ}$, $0.3^{\circ}$, $0^{\circ}$ when moved 1 and 0.02 cm, 0.04 cm, 0.01 cm, $0.3^{\circ}$, $0.5^{\circ}$, $0^{\circ}$ when moved 2. Conclusion: After evaluating the correction rates when they come back to the center, we could tell that the Lateral, Longitudinal, Vertical were all in the acceptable scope of 0.5 cm and Rotation, Pitch, Roll were all in the acceptable scope of $1^{\circ}$. Still, for a more accurate proton therapy treatment, we must try to further enhance the image of the DIPS matching system, and exercise regular QA on the equipment to reduce the current rate of mechanical errors.

  • PDF