• Title/Summary/Keyword: PPG(photoplethysmograph)

Search Result 32, Processing Time 0.023 seconds

A Study on the Temperature Dependence of PPG Measurement Devices (PPG 측정 장치에서의 온도 영향에 대한 연구)

  • Kim, Namsub
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.3
    • /
    • pp.306-311
    • /
    • 2019
  • This paper presents the temperature dependence of transmission-type and reflection-type PPG measurement devices that have been developed in the previous research. PPG signal can be distorted by external temperature such as skin temperature so that many of research was focused on the skin temperature effect. However, this paper focuses on the temperature of the device itself and we studied on the effect of device internal temperature. Experimental results showed that the temperature was increased like an irrational function graph and the transmission-type was not affected by the internal temperature but the reflection-type was affected by the internal temperature.

Heart Rate Estimation Based on PPG signal and Histogram Filter for Mobile Healthcare

  • Lee, Ju-Won;Lee, Byeong-Ro
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.1
    • /
    • pp.112-115
    • /
    • 2010
  • The heart rate is the most important vital sign in diagnosing heart status. The simple method to measure the heart rate in the mobile healthcare device is using the PPG signal. In developing the mobile healthcare device using the PPG signal, the most important issue is the inaccuracy of the measured heart rate because the PPG signal is distorted from the user's motions. To improve the problem, this study proposed the new method that is to estimate the heart rate without an additional sensor in real life. The proposed method in this study is using the histogram filter. In order to evaluate the performance of the proposed method, the study compares its results with the moving average method in motion environment. According to the experimental results, the performance of the proposed method was more than 40% better than the performances of the MAF.

A Real Time Heartbeat Rate Estimation Algorithm Using PPG Signals (광용적맥파를 이용한 실시간 맥박 검출 알고리듬)

  • Kim, Chisung;Han, Dong Seog
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.82-87
    • /
    • 2016
  • The photoplethysmogram (PPG) signal is one of the mainly considered bio signals along with the electrocardiogram (ECG) signal. PPG signals can be used to estimate the speed of flow of blood in vein, saturation of peripheral oxygen and etc. The heartbeat rate is a common feature in order to evaluate those checkup lists. To estimate the correct heartbeat rate, dynamic noises must be removed in the PPG signal. Conventionally, the acceleration signal is used to remove dynamic noises. This method, however, increases the computational complexity. In this paper, we proposes a solution that uses only PPG signals to calculate the heartbeat rate, and which can be used as a basement in real-time healthcare solution.

Development of Blood Pressure Estimation Methods Using The PPG and ECG Sensors (PPG 및 ECG 센서를 이용한 혈압추정 기법 개발)

  • Park, Hyun-Moon;Lee, Jung-Chul;Hwang, Tae-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1257-1264
    • /
    • 2019
  • The traditional cuff-based method for BP(Blood Pressure) measurement is not suitable for continuous real-time BP measurement techniques. For this reason, the previous studies estimated various blood pressures by fusion with the electrocardiography (ECG) and photoplethysmogram (PPG) sensor signals. However, conventional techniques based on PPG bio-sensing measurement face many challenging issues such as noisy supply fluctuation, small pulsation, and drifting non-pulsatile. This paper proposed a novel BP estimation methods using PPG and ECG sensors, which can be derived from the relationship between PPG and ECG using PTT(Pulse Transit Time) and PWV(Pulse Wave Velocity). Unlike conventional height ratio features, which are extracted on the basis of the peaks in the PPG and ECG waveform. The proposed method can be reliably obtained even if there are missing peaks among the sensed PPG signal. The increased reliability comes from periodical estimation of the peak-to-peak interval time using ECG and PPG. After 250,000 times trials of the blood pressure measurement, the proposed estimation technique was verified with the accuracy of ±28.5% error, compared to a commercialized BP device.

Development of Oriental-Western Fusion Patient Monitor by Using the Clip-type Pulsimeter Equipped with a Hall Sensor, the Electrocardiograph, and the Photoplethysmograph (홀센서 집게형 맥진기와 심전도-용적맥파계를 이용한 한양방 융합용 환자감시장치 개발연구)

  • Lee, Dae-Hui;Hong, Yu-Sik;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.4
    • /
    • pp.135-143
    • /
    • 2013
  • The clip-type pulsimeter equipped with a Hall sensor has a permanent magnet attached in the "Chwan" position to the center of a radial artery. The clip-type pulsimeter is composed of a hardware system measuring voltage signals. These electrical bio-signals display pulse rate, non-invasive blood pressure, respiratory rate, pulse wave velocity (PWV), and spatial pulse wave velocity (SPWV) simultaneously measured by using the radial artery pulsimeter, the electrocardiograph (ECG), and the photoplethysmograph (PPG). The findings of this research may be useful for developing a oriental-western biomedical signal storage device, that is, the new and fusion patient monitor, for a U-health-care system.

A Design and Implementation of SpO2 Wearable Device for Companion Animals in PPG Signals

  • Kim, Woo-Chan;Chang, Jin-Wook;Kwon, Hoon;Lee, Won Joo;Kwak, Ho-Young
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.11
    • /
    • pp.191-198
    • /
    • 2022
  • The most basic thing to measure the condition of a companion animal is to check the breathing and pulse. There are several methods to measure the breathing and pulse of a companion animal, and the PPG method is generally used to measure the oxygen saturation (SpO2) in a companion animal. However, since the input PPG signal is inputted with various information as well as oxygen saturation, it is necessary to separate and extract oxygen saturation information from the PPG signal in order to measure the oxygen saturation. Therefore, in this paper, a wearable measuring device for companion animals that can be measured by applying the PPG method was designed and implemented, and an algorithm for separating oxygen saturation information from the PPG signal input through the wearable measuring device was proposed.

Design of Filter to Reject Motion Artifacts of PPG Signal by Using Two Photosensors

  • Lee, Ju-Won;Nam, Jae-Hyun
    • Journal of information and communication convergence engineering
    • /
    • v.10 no.1
    • /
    • pp.91-95
    • /
    • 2012
  • The photoplethysmography (PPG) signal measured from a mobile healthcare device contains various motion artifacts occurring from a patient’s movements. Recently, to reject the motion artifacts, the method of using an acceleration sensor was suggested, but such sensors are very expensive. Therefore, this study deals with a novel sensor device to replace the acceleration sensor, and evaluated the performance of the proposed sensor experimentally. In the results of the experiments, it is shown that the proposed sensor device can reconstruct the PPG signal despite the occurrence of motion artifacts, and also that the variation rate in heart rate analysis was 1.22%. According to the experimental results, the proposed method can be applied to design a low-cost device.

Comparison of blood flow ratio between normal and diabetic neuropathy group using photoplethysmograph (PPG를 이용한 정상인과 당뇨병 환자의 혈류량 비교)

  • Lee, Ju-Hyung;Kim, Sung-Woo;Kang, Eun-Seok;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.77-79
    • /
    • 2007
  • The purpose of this study was to suggest a new detection method for early diagnosing diabetic neuropathic foot by obtaining a ratio of toe to figer blood flow using photoplethysmography(PPG). Nerve conduction velocity (NCV) has been routinely used for diagnosing neuropathic foot, but it applies strong electric stimulus to peripheries resulting in stress and pain. The blood flow ratio of diabetic neuropathy(0.96${\pm}$0.20) was significantly higher in comoarison to normal control group(0.46${\pm}$0.15, left : p<0.05, right : p<0.05) and non-neuropathy diabetic group(0.49${\pm}$0.21, left: p<0.05. right: p<0.05).

  • PDF

Design of A Portable Device for Measuring Heart Rate Using Harmonic Signal and Adaptive Filter (하모닉 신호와 적응 필터를 이용한 휴대형 심박수 측정 장치 설계)

  • Lee, Ju-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.3
    • /
    • pp.723-728
    • /
    • 2010
  • This study proposed a design of a portable device for measuring heart rate using photoplethysmograph signal to minimize load of a nurse increased from insufficiency of an internal hospital nurse, and algorithm to measure reliable heart rate in PPG signals despite the existence of patient's motion artifacts. The proposed method for measuring heart rate is the method to minimize the motion interference by using the adaptive filter based on harmonic characteristic of PPG signal. To evaluate the performances of the a portable device implemented by the proposed method, we used several motion artifacts including finger and wrist movements; we then compared out results with the performance of the moving average filter. In this results, the proposed method showed a better performance than that of the moving average filter. Therefore, when nurses use the a portable device for measuring heart rate proposed in this study, it will enable to improve nurse work and to measure the reliable heart rate.

Design of Motion Artifacts Filter of PPG Signal based on Kalman filter and Adaptive filter (칼만필터와 적응필터를 기반한 PPG 동잡음 제거 필터 설계)

  • Lee, Byeong-Ro;Lee, Ju-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.4
    • /
    • pp.986-991
    • /
    • 2014
  • The PPG signal used in mobile-healthcare and telemedicine system is including the various motion artifact that is signal generated from patient's movements. Recently, although the various methods to remove motion artifacts have been suggested, the performances of these methods are still not satisfactory. Therefore, this s study suggested the novel method based on the Kalman filter and adaptive filter to remove motion artifacts, and we used various motion artifacts to analyze the performance of the proposed method. In the results of experiments, the signal-to-noise ratio of proposed method showed good performace that was 4.8 times of moving average filter.