• Title/Summary/Keyword: PPG(Photoplethysmogram)

Search Result 45, Processing Time 0.024 seconds

Postoperative Pain Assessment based on Derivative Waveform of Photoplethysmogram (광용적맥파 미분 파형 기반 수술 후 통증 평가 가능성 고찰)

  • Seok, Hyeon Seok;Shin, Hangsik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.962-968
    • /
    • 2018
  • In this study, we developed novel indicators to assess postoperative pain based on PPG derivative waveform. As the candidate indicator of postoperative pain assessment, the time from the start of beating to the n-th peak($T_n$) and the n-th peak amplitude($A_n$) of the PPG derivative were selected. In order to verify derived indicators, each candidate indicator was derived from the PPG of 78 subjects before and after surgery, and it was confirmed whether significant changes were observed after surgery. Logistic classification was performed with each proposed indicator to calculate the pain classification accuracy, then the classification performance was compared with SPI(Surgical Pleth Index, GE Healthcare, Chicago, US). The results showed that there were significant differences(p < 0.01) in all indicators except for $T_3$ and $A_3$. The coefficient of variation(CV) of every time-related indicators were lower than the CV of SPI(30.43%), however, the CV in amplitude-related parameters were higher than that of SPI. Among the candidate indicators, amplitude of the first peak, $A_1$, showed that highest accuracy in post-operative pain classification, 68.72%, and it is 15.53% higher than SPI.

A Study of Photoelectric Plethysmography System for the Measurement SpO2 (산소포화도 측정을 위한 광전용적맥파 시스템에 관한 연구)

  • Kim, Hong-Yeop;Kim, Kyung-Ho;Song, Min-Wook
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2010.07a
    • /
    • pp.39-42
    • /
    • 2010
  • 본 연구에서는 두 파장을 이용한 광적용적맥파(photoelectric plethysmography, PPG)의 시스템을 기반으로 산소포화도 및 다양한 맥파 관련 건강정보를 분석할 수 있는 시스템에 관하여 연구하였다. 광적용적맥파를 이용한 산소포화도 측정을 위해 서로 다른 두 파장의 빛을 이용하여 비 침습적 맥파 측정 방식으로 손가락 끝 부분에서 측정하고, 혈액 내 헤모글로빈의 빛 대한 광흡수도의 차이를 분석하여 검출하였다. 또한 정확한 분석을 위하여 두 파장의 빛을 순차적으로 제어하는 스위칭 기법을 사용하고, 조직을 통과한 두 파장의 빛을 분리하기 위하여 수광부에 시간의 차이를 두어 각 파장에 대한 광전용적맥파를 측정하였다. 본 연구에서는 산소포화도를 측정하기 위한 방법으로 서로 다른 두 파장을 이용한 광전용적맥파 측정기기를 설계하고, 측정 결과의 정확성 및 유의성에 대한 검증하였다.

  • PDF

Development of Human Sensibility Evaluation and Biofeedback Technology using PPGs (맥파를 이용한 감성평가 및 Biofeedback 기술의 개발)

  • Lee, Hyun-Min;Kim, Dong-Jun;Woo, Seung-Jin;Yang, Heui-Kyung;Kim, Kyeong-Seop;Lee, Jeong-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.463-464
    • /
    • 2007
  • This study describes a method of a human sensibility evaluation using photoplethysmogram(PPG) signal and a biofeedback algorithm to enhance the sensibility For this objective, the heart rate variability(HRV) is extracted from the PPG signal and using the HRV and its FFT the human sensibility is evaluated. The biofeedback algorithm is designed with motion image player interacting with the results of sensibility evaluation. The sensibility evaluation test showed feasibility of the designed method.

  • PDF

Age-related Changes of the Finger Photoplethysmogram in Frequency Domain Analysis (연령증가에 따른 지첨용적맥파의 주파수 영역에서의 변화)

  • Nam, Tong-Hyun;Park, Young-Bae;Park, Young-Jae;Shin, Sang-Hoon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.1
    • /
    • pp.42-62
    • /
    • 2008
  • Objectives: It is well known that some parameters of the photoplethysmogram (PPG) acquired by time domain contour analysis can be used as markers of vascular aging. But the previous studies that have been performed for frequency domain analysis of the PPG to date have provided only restrictive and fragmentary information. The aim of the present investigation was to determine whether the harmonics extracted from the PPG using a fast Fourier transformation could be used as an index of vascular aging. Methods: The PPG was measured in 600 recruited subjects for 30 second durations, To grasp the gross age-related change of the PPG waveform, we grouped subjects according to gender and age and averaged the PPG signal of one pulse cycle. To calculate the conventional indices of vascular aging, we selected the 5-6 cycles of pulse that the baseline was relatively stable and then acquired the coordinates of the inflection points. For the frequency domain analysis we performed a power spectral analysis on the PPG signals for 30 seconds using a fast Fourier transformation and dissociated the harmonic components from the PPG signals. Results: A final number of 390 subjects (174 males and 216 females) were included in the statistical analysis. The normalized power of the harmonics decreased with age and on a logarithmic scale reduction of the normalized power in the third (r=-0.492, P<0.0001), fourth (r=-0.621, P<0.0001) and fifth harmonic (r=-0.487, P<0.0001) was prominent. From a multiple linear regression analysis, Stiffness index, reflection index and corrected up-stroke time influenced the normalized power of the harmonics on a logarithmic scale. Conclusions: The normalized harmonic power decreased with age in healthy subjects and may be less error prone due to the essential attributes of frequency domain analysis. Therefore, we expect that the normalized harmonic power density can be useful as a vascular aging marker.

  • PDF

Application of Biosignal Data Compression for u-Health Sensor Network System (u-헬스 센서 네트워크 시스템의 생체신호 압축 처리)

  • Lee, Yong-Gyu;Park, Ji-Ho;Yoon, Gil-Won
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.352-358
    • /
    • 2012
  • A sensor network system can be an efficient tool for healthcare telemetry for multiple users due to its power efficiency. One drawback is its limited data size. This paper proposed a real-time application of data compression/decompression method in u-Health monitoring system in order to improve the network efficiency. Our high priority was given to maintain a high quality of signal reconstruction since it is important to receive undistorted waveform. Our method consisted of down sampling coding and differential Huffman coding. Down sampling was applied based on the Nyquist-Shannon sampling theorem and signal amplitude was taken into account to increase compression rate in the differential Huffman coding. Our method was successfully tested in a ZigBee and WLAN dual network. Electrocardiogram (ECG) had an average compression ratio of 3.99 : 1 with 0.24% percentage root mean square difference (PRD). Photoplethysmogram (PPG) showed an average CR of 37.99 : 1 with 0.16% PRD. Our method produced an outstanding PRD compared to other previous reports.

Evaluation of Immediate Effects of an Electrical Massager on Stress Relaxation Using the Heart Rate Variability(HRV) (심박변위도를 이용한 전동 안마기의 단기적 스트레스 완화 효과 평가)

  • Kim, Yong-Dae;Chang, Yun-Seung;Choi, Dong-Hyuk;Lee, Hyun-Ju;Tae, Ki-Sik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.6
    • /
    • pp.75-81
    • /
    • 2010
  • The purpose of this study was to investigate the short-term effects of electrical massager on stress-related parameters including heart rate variability (HRV), heart rate (HR) using the photoplethysmogram (PPG) signal with motion artifact correction. Twenty healthy subjects were randomly allocated to receive a 15-min section of three types ((1) resting mode (control group), (2) light massage mode, (3) strong massage mode). Results indicated that self-report, VAS (Visual Analog Scale) significantly decreased for two massage modes after massage except control group. In strong massage mode, it was associated with significant increases in HF, but significant decreases in LF and LH/HF ratio compared with the light massage mode. For all outcomes, similar changes were not observed in the control group. Also, the result founded that mean HR of all groups decrease. We conclude that electrical massager reduces perceived stress and improves adaptive autonomic response to stress in healthy adults.

Comparison of peripheral vascular sclerosis in diabetic groups using the second derivative of photoplethysmogram (연령별 당뇨병 환자의 PPG 2차 미분 파형의 d/a를 이용한 말초혈관 경화도 비교)

  • Shim, Young-Woo;Lee, Tak-Hyung;Ji, Hyo-Chul;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2008.04a
    • /
    • pp.125-126
    • /
    • 2008
  • 현재, 우리나라 당뇨병의 유병률은 빠른 속도로 증가하고 있으며 당뇨병의 유병기간이 길수록 각종 합병증이 발생하며 더욱 심각한 증세를 나타내기도 한다. 그 중, 비만 및 고혈당, 당대사장애로 인한 당뇨병성 혈관 합병증과 말초 혈관 경화증이 많이 발병하고 있는 실정이다. 본 연구에서는 광혈류량 측정법(Photoplethysmograaphy)으로 손가락에서 얻어진 맥파의 2차 미분 분석을 통해 당뇨병으로 확진된 36명의 당뇨병 환자에 대해 말초혈관 경화도를 연령별로 비교하고자 하였다. 이때 사용한 PPG 파형의 2차 미분 분석 평가 인자는 a와 d이고, d/a는 혈관의 경화도를 의미하며 경화도가 클수록 d/a의 값은 감소하게 되고, 연령이 증가할수록 경화도는 증가하게 된다. 50대 미만의 당뇨병 환자의 d/a값은 $-0.32{\pm}0.12$, 50대는 $-0.48{\pm}0.13$, 60대는 $-0.55{\pm}0.16$, 70대 이상에서는 $-0.59{\pm}0.19$로 연령이 높아질수록 d/a값이 감소하는 것을 확인하였다. 또한, SPSS 13.0 for Windows(SPSS Inc, USA)의 Oneway ANOVA 분석 결과, 연령과 경화도는 통계적으로 유의한 차이를 보였다(p<0.05). 하지만 70대 이상의 당뇨병 환자 그룹에서는 유의한 차이를 확인할 수 없었다. 본 연구에서는 PPG 파형의 2차 미분 분석을 통하여 연령별 당뇨병 환자의 말초혈판 경화도를 비교하였으며, 향후 보완 연구를 통해 비침습적이고 간단한 방법으로 당뇨병 환자의 말초혈관 경화도를 객관적으로 평가하고 진단할 수 있는 시스템 개발로 당뇨병 환자들의 심혈관계질환 사전예방과 치료효과 판정에 도움을 줄 것으로 기대한다.

  • PDF

Reliable Measurement and Analysis System for Ubiquitous Healthcare (고신뢰 유비쿼터스 헬스케어 데이터 측정 및 분석 시스템)

  • Jung, Sang-Joong;Seo, Yong-Su;Kim, Jong-Jin;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.293-297
    • /
    • 2009
  • This paper describes a real-time reliable measurement and analysis system for ubiquitous healthcare based on IEEE802.15.4 standard. In order to obtain and monitor physiological body signals continuously, wearable pulse oximeter is designed in wrist that could used to measure oxygen saturation of a patient unobtrusively. The measured data was transferred to a central PC or server by using wireless sensor nodes via a wireless sensor network for storage and analysis purposes. LabVIEW server program was designed to monitor and process the measured photoplethysmogram(PPG) to accelerated plethysmogram(APG) by appling second order derivatives in server PC. These experimental results demonstrate that APG can precisely describe the features of an individual's PPG and be used as estimation of vascular elasticity for blood circulation.

  • PDF

A Study on Stress Index Estimation using Face Image (얼굴영상을 이용한 스트레스 지수 추정에 관한 연구)

  • Park, Jin-Soo;Hong, Kwang-Seok
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.04a
    • /
    • pp.824-825
    • /
    • 2016
  • 본 논문에서는 얼굴영상을 이용한 스트레스 지수 추정 방법을 제안한다. 얼굴영상으로부터 스트레스 지수(Stress Index)를 추정하기 위해 ROI(Region of Interest) 영역을 지정하고 지정된 영역의 색상공간을 RGB에서 YCgCo로 변환한다. 검출된 얼굴영역에서 프레임별 Cg값의 평균을 구하고 Cg신호의 주기를 이용하여 스트레스 지수를 추정한다. 제안방법의 성능평가를 위해 PPG(Photoplethysmogram) 측정 장비로부터 측정된 스트레스 지수와 얼굴영상을 이용하여 얻은 스트레스 지수를 서로 비교 분석하는 실험을 진행하였고, 성능평가 결과 오차율이 8.32%인 것을 확인하였다.

A Study on Arterial Characterization by using Up-stroke Time of Photoplethysmogram (용적맥파 상승시간에 의한 혈관 특성화 연구)

  • Byeon, M.K.;Han, S.W.;Huh, W.
    • Journal of IKEEE
    • /
    • v.11 no.3
    • /
    • pp.108-116
    • /
    • 2007
  • This paper proposed an analyzable parameter and its analytic method to provide more accurate information than currently employed 4 channels system which uses pulse wave velocity (PWV) information of the volume pulse wave measured from 4 arterial channels for the characterization of arterial vessel. In order to verify the volume pulse waves on 4 sites were simultaneously acquired subjects aged from 12 to 81 years old. and the proposed parameters were extracted from time (UT) was then compared with blood pressure. Then, the regression analyses were done relationships among the proposed parameter and others, such as aging, pulse transit time pressure (BP). The followings are the results of linear regression analysis of the proposed parameter for total 50 normal subjects. We selected any two subjects (58 years and 27 years) and measured PPG (photoplethysmogram) and BP of before and after exercise. The coefficient of correlations between BP and UT observed was -0.928 for 50 years subject, and -0.922 for 20 years subject. For total 50 normal subjects, in case of correlation between the pulse transit time and BP, the result showed -0.170 on left side and -0.233 on right side, and the coefficient value of correlation between the pulse transit time and UT was -0.607 on left side and -0.510 on right side. UI is strongly correlated with the pulse transit time than BP. Hence, we believe that the proposed parameter is related with the index of arterial stiffness.

  • PDF