• Title/Summary/Keyword: POSITION

Search Result 28,592, Processing Time 0.044 seconds

Stepping motor controlling apparatus

  • Le, Ngoc Quy;Jeon, Jae-Wook
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1858-1862
    • /
    • 2005
  • Stepping motor normally operates without feedback and may loss the synchronization. This problem can be prevented by using positional feedback. This paper introduces one method for closed loop control of stepping motor and a method for combining full-step control and micro-step control. This combination controlling apparatus can perform position control with high accuracy in a high speed, so that it will not suffer from vibration (or hunting) problem when stopping motor. Controlling apparatus contains a position counter block for detecting rotor position of stepping motor, a driving block for supplying current to windings of stepping motor, a control block for comparing output signal of position counter block with command position (desired position) and outputting current command signal based on deviation between current position and command position of rotor. To output current command signal, the control block refers to a sine wave data table. This table contains value of duty cycle of Pulse Width Modulation signal. As the second object of this paper, the process of building this data table is also presented.

  • PDF

Effect of Head Elevation and Position on Intracranial Pressure(ICP) in the Neurosurgical Patient with a Cerebral Aneurysm (뇌동맥류 수술환자에게 적용한 두부체위가 두개강내압에 미치는 영향)

  • 박혜자;최경옥;이병옥;정은주;유양숙
    • Journal of Korean Academy of Nursing
    • /
    • v.27 no.3
    • /
    • pp.503-509
    • /
    • 1997
  • This study was undertaken to identify optimal head elevation and position in the care of the neurosurgical patient with a cerebral aneurysm. The effects of 0°. 15° and 30° head elevation and three positions (supine, side tying position opposite to the operation site, and side tying position on the same side as the operation site) on ICP was studied in fourteen neurosurgical patients with cerebral aneurysms. The results are as follows : 1. The mean intracranial pressure was significantly lower when the patient's head was elevated at 30° as compared to 0° and 15°. 2. The mean intracranial pressure was significantly lower when the patient was positioned in the supine as compared to side tying position opposite to the operation site and side tying position on the same side as the operation site. The data indicate that head elevation to 30° and the supine position reduce ICP in neurosurgical patients with cerebral aneurysm.

  • PDF

A study on the real-time Position measurements of mobile object using neural network (신경 회로망을 이용한 이동물체의 실시간 위치측정에 대한 연구)

  • Ro, Jae-H.;Yi, Un-K.;Ro, Young-S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.832-834
    • /
    • 1999
  • This paper is a study on the real-position measurements of mobile object using n network. 2-D PSD sensor is used to measure th position of moving object with light source. Position Sensitive Detector(PSD) is an useful which can be used to measure the position o incidence light in accuracy and in real-time. T the position of light source of moving target, neural network technique are proposed and applied. Real-time position measurements of the mobile robot with light source is examined to validate the proposed method. It is shown that the proposed technique provides accurate position estimation of the moving object.

  • PDF

A Study on Back Bead Formation in Inclined-up Position of Flasma An Orbital Welding (플라즈마 아크 오비탈 용접의 경사상진자세에서 이면비드 형성에 관한 연구)

  • Kim, Hyo-Won;Cho, Sang-Myung
    • Journal of Welding and Joining
    • /
    • v.27 no.1
    • /
    • pp.71-78
    • /
    • 2009
  • In the circumferential welding of pipe, welding phenomenon changes with the position of pipe. Especially in the overhead position, back bead of vertical-up position would be sunk. To investigate the size of back bead and keyhole with the change of the flow rate of pilot and shield gas at each position, bead-on plate welds were conducted on 6mm thickness SS400 with inclined-up position. When the rest of welding conditions remained constant, the width of back bead was increased as the flow rate of pilot gas was increased. And back bead tended to convex as the flow rate of shield gas was increased.

Algorithm for a Initial Pole Position Estimation of PMLSM (영구자석 선형동기전동기의 초기각 추정 알고리즘)

  • Lee Young-Ho;Choi Jong-Woo;Kim Heung-Geun
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.104-108
    • /
    • 2003
  • This paper explained algorithm for a initial pole position estimation of a permanent magnet linear synchronous motor(PMLSM). Generally this motor is considered initial pole position with a position sensor such as incremental encoder for the precise initial pole position estimation and high performance. But this is based on the principle that the initial pole position is accomplished by the PI controller using the maximum values of a position error generated by the new proposed two reference frames and also by using a rated force for input. the proposed algorithm does not utilize the general methods such as impedance ratio, EMF and using the magnetic saturation. In other words, this can be applied without respect to variety of the motor structure because of insensitivity to the motor parameters. In conclusion, simulation results are presented to confirm performance of initial pole position estimation method.

  • PDF

Effect of Biomechanical Intervention based on Custom Seating System on Activities of Mouse Click for Children with Cerebral Palsy (맞춤형 착석장치를 통한 생체역학적 중재가 뇌성마비 아동의 마우스 클릭 동작에 미치는 영향)

  • Jeong, Dong-Hoon
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.2
    • /
    • pp.57-65
    • /
    • 2012
  • Purpose: This study was to investigate the effect of biomechanical intervention, based on the custom seating system on the activities of a mouse click for children with cerebral palsy. Methods: Thirteen children with cerebral palsy participated in this study. We compared reaction time and frequency for proper mouse click in the subject's typical position, in addition to an intervention position. The intervention position conformed to the principle and practice of research on promoting the upper-extremity movement and postural control. The intervention position was achieved through an external postural support, which was based on the custom seating system. Results: Reaction time and frequency for proper mouse click were moderately improved in the intervention position, compared with that of the typical position. There was a statistically significant difference between the typical position and that of the intervention position (p<0.05). Conclusion: Results provide evidence of the positive effects of functional seating on the activities of a mouse click for children with cerebral palsy.

Optimal Angle Error Reduction of Magnetic Position Sensor by 3D Finite Element Method

  • Kim, Ki-Chan
    • Journal of Magnetics
    • /
    • v.18 no.4
    • /
    • pp.454-459
    • /
    • 2013
  • This paper deals with an optimal angle error reduction method of magnetic position sensor using hall effect elements. The angle detection simulation for the magnetic position sensor is performed by 3 dimensional finite element method and Taguchi method, one of the design of experiments. The magnetic position sensor is required to generate ideal sine and cosine waveforms from its hall effect elements according to rotation angle for precise angle information. However, the output signals are easy to include harmonics due to uneven magnetic field distribution from permanent magnet in the air-gap in the vicinity of hall effect elements. For the Taguchi method, three design parameters related to position of hall effect elements and shape of back yoke are selected. The characteristics of optimal magnetic position sensor are compared with those of original one in terms of simulation as well as experiment. Finally, the performances of the motor adopting original model and optimal model are represented for the purpose of verification of motor performance due to signals from magnetic position sensor.

The Knee Joint Position Sense in Healthy Women (정상 성인 여성의 무릎관절 위치감각)

  • Yang, Kyung-Hye;Lee, Hyun-Ok
    • PNF and Movement
    • /
    • v.8 no.1
    • /
    • pp.31-39
    • /
    • 2010
  • Purpose : The purpose of this study is to ascertain whether age, body mass index(BMI) and exercise frequency(EF) are correlated with knee joint position sense in healthy women. Methods : Healthy women of 150 who participated in this study were tested knee joint position sense; each reposition error was analyzed according to the age, BMI and EF. Reposition error was measured with a Myrin goniometer. Results : The age groups, BMI groups and EF groups demonstrated significant differences of the knee joint position sense. The older the healthy women are, the higher BMI is, and the lower EF is, the more decreased knee joint position sense has become. Conclusion : The older the women are, the higher BMI is, and the lower EF is, the more decreased the knee joint position sense in healthy women is. Therefore it needs to be considered to require management of obesity and regular exercise for prevention of knee injuries due to decreased joint position sense.

  • PDF

Computation of Sun Position for the Sun Tracking Control System of Solar Concentrator (집광식 태양열 집열기의 태양추적장치를 위한 태양위치계산)

  • Park, Y.C.;Kang, Y.H.
    • Solar Energy
    • /
    • v.18 no.4
    • /
    • pp.87-94
    • /
    • 1998
  • This work presents a method to compute the sun position(azimuth and elevation), sunrise and sunset times. Accurate computation of sun position is very important to the precise tracking of the sun for the solar concentrator, which enables the maximum collection of solar energy. Methods to compute the sun position are available in the literature already. However most of them do not have accuracy verification, thus makes hard in selecting the most accurate sun position computation method. We first select the most accurate sun position computation method among the methods presented in the literature by comparing the computed sun position with Korean Almanac of Korea Astronomy Observatory. Then a procedure to compute the sunrise and sunset times is presented. Computed sun position shows $0.02^{\circ},\;0.6^{\circ}$ and one minute differences in azimuth, elevation and sunrise/sunset times respectively compared with Korean Almanac.

  • PDF

Position Estimator Employing Kalman Filter for PM Motors Driven with Binary-type Hall Sensors

  • Lee, Dong-Myung
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.931-938
    • /
    • 2016
  • Application of vector control scheme for consumer products is enlarging to improve control performance. For the field-oriented control, accurate position detection is essential and generally requires expensive sensors. On the other hand, cost-reduction is important in home appliances, so that binary-type Hall-effect sensors are commonly used rather than using an expensive sensor such as an encoder. The control performance is directly influenced by the accuracy of the position information, and there exist non-uniformities related to Hall sensors in electrical and mechanical aspects, which result in distorted position information. Therefore, to get high-precision position information from low-resolution Hall sensors, this paper proposes a new position estimator consisting of a Kalman filter and feedforward compensation scheme, which generates a linearly changing position signal. The efficacy of the proposed scheme is verified by simulation and experimental results carried out with a 48-pole permanent magnet motor.