• Title/Summary/Keyword: PON

Search Result 410, Processing Time 0.028 seconds

Technical reviews in fiber to the home (FTTH) (FTTH 기술 발전 동향)

  • Shin, Byung-Gon;Park, Jae-Hyoung;Kim, Jin-Hee
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.283-286
    • /
    • 2008
  • This article describes developments in fiber to the home (FTTH), and introduces the technical reviews for the various types to realize FTTH. Also, we have presented the results of each EPON, GPON and WDM-PON standardization by each IEEE, ITU-T and TTA. Finally, based on the above results, we proposed the trend of FTTH service deployment strategies.

  • PDF

Cooper ions and hypochlorite are mainly responsible for oxidative inactivation of paraoxon-hydrolyzing activity in human high density lipoprotein

  • Su, Nguyen-Duy;Kim, Ju-Ryung;Eun, Sok-Dai
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.141.1-141.1
    • /
    • 2003
  • Paraoxonase, an antioxidant enzyme, exclusively located on HDL is well known for both hydrolysis of organophosphate and prevention against LDL oxidation. It have been reported that PON1 decrease its activity under oxidative stress and that PON1 activity is lower in subject with higher vulnerability to organophosphate poisoning. The aim of our study is to examine the effect of oxidative system on paraoxon-hydrolzing activity and to elucidate the plausible mechanisms responsible for the decline of HDL-asscociated PON1 activity in vivo system. (omitted)

  • PDF

Compact 2.5 Gb/s Burst-Mode Receiver with Optimum APD Gain for XG-PON1 and GPON Applications

  • Kim, Jong-Deog;Le, Quan;Lee, Mun-Seob;Yoo, Hark;Lee, Dong-Soo;Park, Chang-Soo
    • ETRI Journal
    • /
    • v.31 no.5
    • /
    • pp.622-624
    • /
    • 2009
  • This letter presents a compact 2.5 Gb/s burst-mode receiver using the first reported monolithic amplifier IC developed with 0.25 ${\mu}m$ SiGe BiCMOS technology. With optimum avalanche photodiode gain, the receiver module can obtain a fast response, high sensitivity and wide dynamic range, satisfying the overhead timing and various power specifications for a 2.5 Gb/s next-generation passive optical network (PON), as well as a legacy 1.25 Gb/s PON in the upstream.

Demonstration of RSOA-Based 20 Gb/s Linear Bus WDM-PON with Simple Optical Add-Drop Node Structure

  • Lee, Han-Hyub;Cho, Seung-Hyun;Lee, Eun-Gu;Lee, Sang-Soo
    • ETRI Journal
    • /
    • v.32 no.2
    • /
    • pp.248-254
    • /
    • 2010
  • We demonstrate a linear bus wavelength-reused gigabit wavelength-division multiplexing passive optical network (WDM-PON) with multiple optical add-drop nodes. A commercially available reflective semiconductor optical amplifier-based WDM-PON has a sufficient power budget to provide multiple optical add/drop nodes in 16 WDM channels. Sixteen 1.25 Gb/s WDM channels are successfully transmitted over 20 km of single-mode fiber with four optical add/drop multiplexers, even with 32 dB reflection and chromatic dispersion in the link.

Technology of Smart Optical Distribution Network and its Standardization Trends (스마트 광 분배망 기술 및 표준화 동향)

  • Kim, S.C.;Kim, G.Y.;Kim, J.J.;Yoo, H.;Lee, D.S.;Kim, Y.S.
    • Electronics and Telecommunications Trends
    • /
    • v.29 no.5
    • /
    • pp.145-155
    • /
    • 2014
  • 최근 급격히 증가하고 있는 모바일 데이터 트래픽으로 인하여 이를 효과적으로 수용할 수 있는 수동형 광 가입자망(PON: Passive Optical Network) 기술에 대한 요구사항도 높아져가고 있다. 특히, 서비스 제공 시간을 줄이고 망 신뢰성을 향상시키며 망 운용관리 비용을 줄이기 위하여 PON 인프라인 광 분배망(ODN: Optical Distribution Network) 링크에 대한 실시간 장애 검출 기술과 물리적 광 커넥션의 자동인식 및 통합관리 기술에 활발한 연구 및 표준화가 진행 중이다. 본고에서는 PON 링크의 실시간 장애 검출 기술 및 광 분배망 자동인식/통합관리 기술동향에 대하여 소개하고 연계된 국제 표준화 진행사항에 대해 알아본다. 마지막으로 ETRI에서 연구 개발 중인 스마트 RN(Remote Node) 기술에 대해 기술한다. 스마트 RN 기술은 장거리(60Km 이상), 고분기(128분기 이상) 추세로 진화되고 있는 PON망에 적용하여 자동화된 광계층의 장애 검출 및 ODN 인프라 자동인식/통합관리 기능을 제공한다.

  • PDF

A study on monitor filter PLC monitor device PON system (PON 시스템 감시 모니터용 PLC 소자)

  • Choi, Young-Bok;Park, Soo-Jin;Koh, Seok-Bong;Lee, Bong-Young
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.22-26
    • /
    • 2007
  • In the fibre to the home (FTTH) era, it is expected that broadband network provisioning will require thousands of optical fibres to be accommodated in a central office for optical access networks. An optical fibre line testing system could be used to reduce maintenance costs and improve service availability depending on the PON's element manager capabilities and the maintenance procedures adopted by the network supplier. When monitoring optical fibres transmitting communication lights, a wavelength of 1625 nm is used for maintenance testing. The splitter installed optical filters allow the communication light to pass but that cut off the test light in the front of optical line terminals (OLTs) and optical network terminals (ONTs). In the economic point of view, We design new planer lightwave circuit splitter embedded filtter and study it optical property.

  • PDF

FTTH FOR APARTMENT COMPLEXES USING CWDM-PON SYSTEM (공동주택에 대한 FTTH OSP 구축과 CWDM-PON 을 이용한 서비스 제공)

  • Kim, Bo-Gyum;Koh, Seok-Bong
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.289-292
    • /
    • 2007
  • FTTH (Fiber to the Home) is constructed with optical devices and optical cables from central office (CO) to subscribers. With FTTH, it is possible to provide service platform in order to meet the customers' emerging demands for more bandwidth/security and diverse IP multimedia applications including high definition (HD) video streaming service. FTTH can provide enough bandwidth from 100Mbps to several Gbps per subscriber. It is also most appropriate network architecture for convergence of communication and broadcasting. So, FTTH is thought the final destination of telecom operators, since it is the fastest and most reliable solution so far and various IP multimedia services are possible through it. In this paper, newly attempted technologies of FTTH construction for apartment complexes using CWDM-PON system are discussed.

  • PDF

A study of Queuing Algorithm on ONU of the Ethernet-PON according to the Traffic classes (트래픽 종류에 따른 Ethernet-PON 내의 OUN에서의 큐잉 알고리즘에 관한 연구)

  • Lee, Dong-Soak;Lee, Soon-Hwa;Kim, Chang-Bock
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2003.05b
    • /
    • pp.1289-1292
    • /
    • 2003
  • 고속 대용량의 통합된 정보를 전송하기 위한 기간망(backbone network)과 가입자망(access network) 사이에는 병목 현상에 따른 congestion 문제가 불가피하다. 따라서 증가하는 가입자측의 대역폭 수요에 따라 가입자측까지 광케이블의 연결을 현실화할 수 있는 기술로서 PON(Pasive Optical Network)구조가 대두되고 있다. 본 연구는 네트워크 시뮬레이션인 OPNET을 사용하여 기존의 망과 가장 호환이 용이한 ethernet 기술을 이용한 PON 구조의 상향링크에서 ONU내에 traffic 타입에 따른 큐잉 알고리즘을 적용하여 QoS(Qualify of Service)를 보장하고자 한다.

  • PDF

Next Generation OFDM-based Optical Access Network Technologies (OFDM 기반 차세대 광가입자망 연구 동향)

  • Doo, K.H.;Cho, S.H.;Bang, H.J.;Lee, S.S.;Lee, J.H.
    • Electronics and Telecommunications Trends
    • /
    • v.28 no.6
    • /
    • pp.63-74
    • /
    • 2013
  • 모바일, 클라우드, 빅데이터 등 최근 IT 산업의 패러다임의 변화로 인해 매년 25% 이상 증가하는 트래픽 추세에 따라 광 가입자망의 전송 기술도 빠르게 진화하고 있다. 가입자 망의 영역 확장을 위해 분기 수, 전송 거리 확대를 위한 기술개발 및 표준화 노력 또한 끊임없이 이어지고 있다. 링크당 40Gbps 이상의 전송 속도를 요구하는 차세대 광 가입자망 기술 중의 하나인 OFDM 기반 PON은 멀티캐리어 방식으로 대용량, 장거리 전송이 가능하며, 서브캐리어 별로 서비스를 분리할 수 있고, 유연한 서브캐리어 관리를 통해 동적 대역 할당이 가능하므로 향후 유무선 융합 가입자 망에 적합한 기술로써, 기존 광 분배망의 구조 및 시설 교체없이 WDM(Wavelength Division Multiplexing)-PON(Passive Optical Network), T(Time)DM-PON 기술과 융합하여, 전송 용량을 확장할 수 있는 큰 장점을 가지고 있다. 본고에서는 OFDMA-PON 기술을 소개하고, EU, 미국 등 선진 연구 기관의 연구동향을 소개하고 향후 전망에 대해 논하고자 한다.

Fast Management of ONUs Based on Broadcast Control Channel for a 10-Gigabit-Capable Passive Optical Network (XG-PON) System

  • Lee, Youngsuk;Lee, Dongsoo;Yoo, Hark;Kim, Youngsun;Kim, Younghan
    • Journal of Communications and Networks
    • /
    • v.15 no.5
    • /
    • pp.538-542
    • /
    • 2013
  • This paper proposes a broadcast software download (BSD) scheme for a 10-gigabit-capable passive optical network (XG-PON), which dramatically reduces the time required to update a remotely-located user terminal's software. The performance of the proposed BSD is examined by numerical analysis and demonstrated by experimental verification on our XG-PON test platforms. The results show that the BSD takes less than 5 minutes to update 45 user-terminal software, while the conventional unicast software download scheme normally takes more than one and half hours.