An Experimental Study on Energy Consumption of Air Washer Outdoor Air Conditioning Systems for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 에어와셔 외기공조시스템의 에너지소비량에 관한 실험적 연구)

  • Kim, Ki-Cheol;Kim, Hyung-Tae;Song, Gen-Soo;Yoo, Kyung-Hoon;Son, Seung-Woo;Shin, Dae-Kun;Park, Dug-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.4
    • /
    • pp.297-305
    • /
    • 2012
  • In recent large-scale semiconductor manufacturing clean rooms, the energy consumption of outdoor air conditioning systems to heat, humidify, cool and dehumidify incoming outdoor air represents about 45% of the total air conditioning load required to maintain a clean room environment. Therefore, the energy performance evaluation and analysis of outdoor air conditioning systems is useful for reducing the outdoor air conditioning load for a clean room. In the present study, an experiment was conducted to compare the energy consumption of outdoor air conditioning systems with a simple air washer, an exhaust air heat recovery type air washer and a DCC return water heat recovery type air washer. It was shown from the present lab-scale experiment with an outdoor air flow of 1,000 $m^3/h$ that the exhaust air heat recovery type and DCC return water heat recovery type air washer outdoor air conditioning systems were more energy-efficient for the summer and winter operations than the simple air washer outdoor air conditioning system and furthermore, the DCC return water heat recovery type one was the most energy-efficient in the winter operation.

An Assessment of Energy Consumption in Steam-Humidification- and Water-Spray-Humidification-Type Outdoor Air Conditioning Systems for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 증기가습 및 수분무가습 외기공조시스템의 에너지소비량 평가)

  • Kim, Ki-Cheol;Song, Gen-Soo;Kim, Hyung-Tae;Yoo, Kyung-Hoon;Shin, Dae-Kun;Park, Dug-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.2
    • /
    • pp.55-63
    • /
    • 2013
  • For a large-scale semiconductor manufacturing clean room, the energy consumed in an outdoor air conditioning system to heat, humidify, cool and dehumidify incoming outdoor air is very large. In particular, the energy requirement to humidify outdoor air in the winter season is generally known to be high. Recently, in order to overcome the high energy consumption nature of a steam generator in a conventional steam humidification type outdoor air conditioning system, an air washer is often introduced instead of the steam generator in the outdoor air conditioning system, which can be called a water spray humidification type outdoor air conditioning system. Therefore, the assessment and comparison of the annual energy consumed in the steam humidification type and the water spray humidification type outdoor air conditioning systems deserves to be examined in order to reduce the outdoor air conditioning load of a clean room. In the present study, a numerical analysis was conducted to obtain the annual electric power consumption of the two outdoor air conditioning systems. It was shown from the comparison of the numerical results that the water spray humidification type outdoor air conditioning system can reduce about 30% of annual electric power consumption of the steam humidification type outdoor air conditioning system.

Effect of Cargo Employee Recognition of Work Environment on the Job Satisfaction and Organizational Commitment in the Port Industry (부산항 항만하역근로자의 근무환경에 대한 인식이 직무만족과 조직몰입에 미치는 영향)

  • Kim, Tae-Min;Ha, Myung-Shin;Choi, Sung-Kwang
    • Journal of Korea Port Economic Association
    • /
    • v.34 no.4
    • /
    • pp.85-104
    • /
    • 2018
  • Globally, more than 90 percent of all international commerce takes place via sea freight. In terms of container cargo volume, Busan Port is the world's sixth largest port, given its geographical conditions. Regarding geographic advantages, a cargo-working operation that met customers' demand using a 24-hour operating delivery system also contributed to the growth of Busan Port as a global hub. However, research and studies on the working conditions for stevedores are lacking, even though the port industry relies heavily on human resources. Therefore, this study identifies the awareness of the working environment by cargo-working employees at Busan Port and their satisfaction level related to their working environment, such as working two shifts in a 24-hour period.

Bandwidth Reservation and Call Admission Control Mechanisms for Efficient Support of Multimedia Traffic in Mobile Computing Environments (이동 컴퓨팅 환경에서 멀티미디어 트래픽의 효율적 지원을 위한 대역폭 예약 및 호 수락 제어 메커니즘)

  • 최창호;김성조
    • Journal of KIISE:Information Networking
    • /
    • v.29 no.6
    • /
    • pp.595-612
    • /
    • 2002
  • One of the most important issues in guaranteeing the high degree of QoS on mobile computing is how to reduce hand-off drops caused by lack of available bandwidth in a new cell. Each cell can request bandwidth reservation to its adjacent cells for hand-off calls. This reserved bandwidth can be used only for hand-offs, not for new calls. It is also important to determine how much of bandwidth should be reserved for hand-off calls because reserving too much would increase the probability of a new call being blocked. Therefore, it is essential to develop a new mechanism to provide QoS guarantee on a mobile computing environment by reserving an appropriate amount of bandwidth and call admission control. In this paper. bandwidth reservation and call admission control mechanisms are proposed to guarantee a consistent QoS for multimedia traffics on a mobile computing environment. For an appropriate bandwidth reservation, we propose an adaptive bandwidth reservation mechanism based on an MPP and a 2-tier cell structure. The former is used to predict a next move of the client while the latter to apply our mechanism only to the client with a high hand-off probability. We also propose a call admission control that performs call admission test only on PNC(Predicted Next Cell) of a client and its current cell. In order to minimize a waste of bandwidth caused by an erroneous prediction of client's location, we utilize a common pool and QoS adaptation scheme. In order evaluate the performance of our call admission control mechanism, we measure the metrics such as the blocking probability of new calls, dropping probability of hand-off calls, and bandwidth utilization. The simulation results show that the performance of our mechanism is superior to that of the existing mechanisms such as NR-CAT2, FR-CAT2, and AR-CAT2.

Comparative Study on Energy Consumption in Steam-Humidification- and Water-Spray-Humidification-Type Outdoor Air-Conditioning Systems for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 증기가습 및 수분무가습 외기공조시스템의 에너지소비량 비교연구)

  • Kim, Hyung-Tae;Song, Gen-Soo;Kim, Ki-Cheol;Yoo, Kyung-Hoon;Son, Seung-Woo;Shin, Dae-Kun;Park, Dug-Jun;Kwon, Oh-Myung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1249-1255
    • /
    • 2011
  • In modern large-scale semiconductor manufacturing clean rooms, the energy consumed by the outdoor air-conditioning system during heating, humidification, cooling, and dehumidification of the incoming outdoor air represents about 45% of the total air-conditioning load required to maintain a clean-room environment. In particular, the energy required for humidification of the outdoor air in winter is very high. Therefore, evaluation and comparison of the energy consumption in key humidification systems, viz., steam-humidification and water-spray-humidification systems, used in outdoor air-conditioning systems would be useful to reduce the outdoor air-conditioning load in clean rooms. In the present study, an experiment with an outdoor air flow of 1000 $m^3$/h was conducted to compare the air-conditioning process and energy consumption in outdoor air-conditioning systems with electrodeboiler steam humidifiers and air-washer water spray humidification systems. The experimental results showed that the water-spray-humidification-type outdoor air-conditioning system consumed less electrical power than did the steam-humidification-type system and was more energy efficient during winter.

Examining Mathematics Teachers' Intentions regarding Formative Assessment (수학 수업 지도안에 나타난 교사가 설계하는 형성평가 분석)

  • Lee, DaEun;Kim, Gooyeon
    • Communications of Mathematical Education
    • /
    • v.35 no.4
    • /
    • pp.527-546
    • /
    • 2021
  • The purpose of this study is to reveal what mathematics teachers focus on and how they assess students' thinking during lessons enacted. For this purpose, we googled and searched internet sites to collect formative assessment materials for the year 2014 to 2019. The formative assessment tasks data were analyzed according to the levels cognitive demand levels and tasks suggested in textbooks in terms of degrees to which how they are related. The data analysis suggested as follows: a) most of the formative assessment tasks were at the low-level, in particular, PNC level tasks that require applying particular procedures without connections to concepts and meaning underlying the procedures, b) the assessment tasks appeared to be very similar to the tasks suggested in the secondary mathematics textbooks, and c) it seemed that 3 types of formative assessment, observation notes, self-assessment, and peer-assessment were dominantly utilized during mathematics lessons and these different types of formative assessment were employed apparently to find out whether students participated actively in class and in group activity, not how they go through understanding or thinking processes.

Identification of Novel Single Nucleotide Polymorphisms on ADSL Gene Using Economic Traits in Korean Native Chicken (한국재래닭의 ADSL 유전자 내 단일염기변이를 이용한 경제형질과의 연관성 분석)

  • Lee, J.A.;Jeon, S.A.;Oh, J.D.;Park, K.D.;Choi, K.D.;Jeon, G.J.;Lee, H.K.;Kong, H.S.
    • Korean Journal of Poultry Science
    • /
    • v.36 no.3
    • /
    • pp.207-213
    • /
    • 2009
  • Adenylosuccinate lyase (ADSL) deficiency is a disease of purine metabolism which affects patients both biochemicall and behaviorally. An obstacle of this purine nucleotide cycle(PNC) can be caused brain functional disorder and growth disorder. So ADSL deficiency, which is associated with sever mental retardation, autistic features and energy metabolism. This study was performed to identify SNP on ADSL gene in chicken. The nucleotides were observed as T to C ($7724^{th}$ nucleotide), C to T ($7732^{nd}$ nucleotide), G to T ($10108^{th}$ nucleotide), A to T ($10356^{th}$ nucleotide), G to A($10375^{th}$ nucleotide), A to C ($10402^{nd}$ nucleotide), A to T ($12716^{th}$ nucleotide), T to A ($12717^{th}$ nucleotide), C to T ($15491^{st}$ nucleotide), C to T ($15542^{nd}$ nucleotide) and C to T ($15550^{th}$ nucleotide). The nucleotide substitutions at $15542^{nd}$ and $15550^{th}$ (GeneBank accession no. AY665559) were found as missense mutation (alanine$\rightarrow$valine, proline$\rightarrow$serine, respectively). This study will be useful for farther researches for identifying association between these SNPs and energy metabolism in chicken. The C15550T SNP showed three genotypes, CC, CT, TT by digestion with the genotype TT had significantly faster the first lay day (150.0) than CT (162.0, P<0.05) and genotype TT (150.0, P<0.05) had significantly higher the egg production rate than CT (172.4, P<0.05). According to result of this study, a C15550T was found to have a significantly effect first lay day and mean egg production. It will be possible to use SNP marker on selecting chicken to improve important economic traits, which is the first lay day and mean egg production.