실내 온열환경 제어를 위한 PMV 센서의 개발 및 적용성 평가연구 (Development and Evaluation of a PMV Sensor for the Control of Indoor Thermal Environment)

  • 윤동원;강효석;안병욱
    • 설비공학논문집
    • /
    • 제15권10호
    • /
    • pp.870-878
    • /
    • 2003
  • The maintenance of thermal equilibrium between the human body and its environment is one of the primary requirements for health, wellbeing and comfort. For the effective control of indoor thermal environment, thermostat or humidistat is used. But, it is not sufficient to control the indoor thermal environment using only one or two parameters as human response for the indoor comfortable environment. So an environmental thermal index is required for the control of indoor thermal environment effectively. In this study, a PMV sensor has been developed which has integrated from various kinds of individual sensors for temperature, humidity, air velocity, radiant temperature. After applying the PMV and PPD equation, it is possible to monitor the indoor thermal environment with the sensor system, which is adopted to the circuit for optimization according to the human response with the metabolic rate and activities. The measurement was carried out to verify the performance of the integrated sensor system in comparison with existing measurement system, the PMV meter. As a result, the possibility of applying the PMV sensor to control the indoor thermal environment simultaneously was examined.

PMV 제어에 따른 사무소 건물의 실내열환경과 에너지소비량 분석 (Analysis of Indoor Thermal Environment and Energy Consumption in Office Building Controlled by PMV)

  • 장향인;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제33권4호
    • /
    • pp.15-22
    • /
    • 2013
  • The purpose of this study is to analyse the effects of air conditioned room controlled by PMV(Predicted Mean Vote)for energy consumption and human comfort in office building. The 'EnergyPlus' was used for the evaluation of indoor thermal environment and energy consumption by the controls of room temperature and PMV. The result indicates that the PMV control could prove more profitable method for improvement of indoor thermal environment and energy conservation. Consequently, PMV control has a distinct advantage over most other control methods. An additional study is required to establish the various thermal comfort control for rooms on the basis of this work.

안면 피부온도를 활용한 PMV 지표 기반 쾌적환경 조성의 타당성 연구 (The Validation Study of Shaping Comfortable Environments Based on the PMV Index Using Facial Skin Temperature)

  • 김보성;민윤기;신에스더;김진호
    • 감성과학
    • /
    • 제16권3호
    • /
    • pp.311-318
    • /
    • 2013
  • 본 연구는 인간의 생리적 지표 중 하나인 안면 피부온도를 활용하여 PMV 지표 값에 기반하여 조성된 쾌적/불쾌 실내 환경을 적절하게 구분할 수 있는지 그 타당성을 살펴보고자 하였다. 이를 위해 쾌적 실내 환경에 해당되는 PMV 지표 값을 기준으로 물리적 환경을 쾌적 실내 환경과 불쾌한 실내 환경으로 각각 구분하고, 구분된 환경내에서 재실자의 안면 피부온도를 측정하였다. 그 결과, PMV 지표 값으로 구분된 쾌적 실내 환경과 불쾌한 실내 환경에서의 재실자의 안면 피부온도가 서로 차이를 보이는 것으로 나타났다. 이는 안면 피부온도가 PMV 지표에 기반한 쾌적한 실내 환경 조성에 있어 활용될 수 있음을 시사한다. 그러나 쾌적한 실내 환경에 비해 불쾌한 실내 환경에서 안면 피부온도가 낮게 나타나는 결과를 통해 오히려 PMV 지표 값에 기반을 두고 조성되는 쾌적/불쾌환경이 타당하지 않을 수 있음도 시사한다.

  • PDF

PMV 온열 환경과 조도가 시작업 성능에 미치는 영향에 대한 연구 (A Study on the Effects of PMV Thermal Environment and Illumination on Visual Performance)

  • 김형선;김형태;김형식;곽원택;김진호
    • 감성과학
    • /
    • 제17권2호
    • /
    • pp.55-62
    • /
    • 2014
  • 본 연구에서는 PMV 온열환경이 변화함에 따라 LED광원의 조도가 시작업 성능에 미치는 영향을 분석하기 위해 오류검색수정작업 평가지를 개발하였고, 오류검색수정작업의 정확도 및 소요시간을 분석하였다. 또한 작업을 진행하면서 느끼는 시각피로도에 대한 설문을 실시하여 주관적인 평가도 병행하였다. 본 실험의 PMV 온열환경은 온도 $17{\pm}1{\sim}29{\pm}1^{\circ}C$, 습도 $50{\pm}5{\sim}60{\pm}5%$의 범위에서 PMV 값에 따라 4가지 형태를 구성하였으며, LED광원의 조도는 400lx, 700lx, 1000lx의 3가지 형태로 구성하여 실험을 진행하였다. 오류검색수정작업의 정확도(LED p 값=0.058, PMV*LED p값=0.083) 및 소요시간(LED p값=0.004, PMV p값=0.000)은 PMV 온열환경과 LED광원의 조도 변화에 모두 유의하였으나, 피로도는 PMV 온열환경(p값=0.003)과 유의한 차이를 보였다.

초등학교 교실에서 적용한 환경주의력 평가기법 개발에 관한 연구 (Study on Development of Environmental Attention Assessment Applied in the Elementary Classroom)

  • 정지원;이희관
    • 한국대기환경학회지
    • /
    • 제32권6호
    • /
    • pp.624-632
    • /
    • 2016
  • Attention plays vital role either students academic performance in classroom or work performance of workers. This study was accomplished among elementary school students of elementary school classroom for two years. Three experiment cases were designed based on the Predicted Mean Vote (PMV) indexes. Thermal environment and PMV were directly monitored; Thermal Sensation Vote (TSV) and Comfort Sensation Vote (CSV) were analyzed based on survey data; and attention was analyzed for different comfort level using FAIR program. PMV, TSV and CSV were varied with the change in thermal environment and there was not noticeable gender influence on impact. The good correlation between thermal environment, PMV, TSV and CSV confirmed the impact of thermal environment on indoor comfort. There were different impacts on attention with comfort conditions. Academic attention of low attention group i.e. weak students, can be improved by providing the comfort environment. Thermal environment influences the comfort and the comfort influences the attention, it is possible to assess the impact of thermal environment on attention in further.

공동주택의 냉방시 실내온열환경 평가 연구 (Evaluation of Indoor Thermal Environment for Cooling in Apartment House)

  • 김난행;안병욱
    • 한국주거학회논문집
    • /
    • 제14권3호
    • /
    • pp.1-8
    • /
    • 2003
  • It is not sufficient to control the indoor thermal environment using only one or two parameters by itself as human response for the control of indoor thermal environment. So a proper environmental thermal index is required for the control of indoor thermal environment effectively. In this study, the physical environment was measured and analysed and the skin temperature of the subjects and their response were investigated to evaluate the optimum thermal comfort range for cooling season in an apartment house. As a result, the optimal temperature was 26.1$^{\circ}C$ and the temperature ranges which more than 80% responded as satisfactory were 24.1~28.$0^{\circ}C$, respectively. As the OT had most significant interrelation with the PMV, it is desirable to use the OT in evaluating the thermal environment during cooling. Also, the comfort range was concluded between OT 25.5~27.3$^{\circ}C$ by appointing the PMV of -0.5~0.5 as the optimum comfort condition. In addition, the Human responses were compared with calculated PMV, OT and MRT and the relationships are suggested in order to utilize to control indoor thermal environment.

PMV지표를 이용한 공동주택의 난방제어에 따른 온열환경 및 에너지소비량 시뮬레이션 (An Approach of Indoor thermal Environment Control and Energy Saving Using the PMV Index)

  • 성남철;윤동원
    • 토지주택연구
    • /
    • 제1권1호
    • /
    • pp.19-25
    • /
    • 2010
  • 최근 에너지 절약을 화두로 건물에서의 에너지 절약기술들이 크게 요구되어 지는 반면 재실자의 온열쾌적환경은 비교적 비중 있게 다루어지지 않고 있다. 실내공간의 쾌적성은 재실자의 만족감과 더불어 생산성을 향상시키는 등의 역할을 하며, 최근 삶의 질 향상 등에 따라 그 필요성이 크게 요구되고 있는 실정이다. 따라서 본 연구에서는 공동주택을 대상으로 겨울철 난방 시 쾌적지표를 통한 실내 온열환경 제어의 타당성을 검토하고자 시뮬레이션을 수행하였으며, 주거건물에서의 일상적인 실내온도와 에너지 절약 설계기준에서 제시한 실내 설정온도, 그리고 쾌적지표를 설정으로 한 각 제어조건의 온열환경과 에너지 소비량을 비교 분석 및 검토하였다. 본 연구결과에 따르면, 쾌적지표인 PMV로 실내환경을 제어했을 때 에너지 절약설계 기준인 $22^{\circ}C$로 실내온도를 설정하였을 때보다 에너지 소비량은 29% 증가하지만 주거용 건물에서 일반적으로 유지되는 실내온도인 $24^{\circ}C$ 보다는 에너지소비량은 11% 정도 감소하며, 온열쾌적감도 각 제어조건 중 가장 우수하게 나타났다. 따라서 여러 가지 제어변수들을 통한 연구가 지속된다면 주거용 건물에서도 쾌적지표를 활용한 실내 공간의 제어방법은 건물의 에너지를 절약하고 실내 환경의 쾌적성을 증대시키는 주요기술이 될 수 있을 것으로 기대된다.

황토벽돌벽 주택의 실내온열환경에 관한 연구 (A Study on the Indoor Thermal Environment of House Using Earth Brick Wall)

  • 이재윤
    • 한국주거학회논문집
    • /
    • 제15권1호
    • /
    • pp.25-32
    • /
    • 2004
  • The purpose of this study is to understand the indoor thermal environment in the earth brick wall building what is called a ecological Architecture. To investigate thermal performances of the earth brick walls, it measured indoor and outdoor air temperature, relative humidity, globe temperature and PMV in reference house. The result of this study were summarized as the followings; 1) When the outdoor average air temperature was $21.8^{\circ}$, livingroom was $24.9^{\circ}$, kitchen was $25.1^{\circ}$ and 2nd floor room was $25.6^{\circ}$ at 150 cm height from the floor. 2) Although the average outdoor relative humidity was 78%, the livingroom was 67.5%. 3) As the air temperature difference between at the top and bottom was $0.6^{\circ}$ in living room, this value was below 1 % of PPD by ASHRAE Handbook. 4) Predicted Mean Vote(PMV) by ISO-7730 was +0.41.

실내 온열환경 쾌적 제어를 위한 단순 PMV 회귀모델의 적용에 관한 시뮬레이션 연구 (A Study on the Application of Simulation-based Simplified PMV Regression Model for Indoor Thermal Comfort Control)

  • 김상훈;윤성준;정광섭
    • 에너지공학
    • /
    • 제24권1호
    • /
    • pp.69-77
    • /
    • 2015
  • 본 연구에서는 보정된 모델링 건물을 대상으로 PMV 변수에 대한 데이터베이스를 구축하였고, 다중회귀분석을 통하여 PMV 회귀모델을 도출하였다. PMV 회귀모델은 민감도 및 데이터 분석을 통하여 단순화하여 단순 PMV 회귀모델을 제시하였다. 단순 PMV 회귀모델과 Fanger PMV 모델에 대한 MAE 및 RMSE 검증을 통하여 단순 PMV 회귀모델이 Fanger PMV 모델을 대체할 수 있는 것으로 분석되었다. EnergyPlus의 EMS(Energy Management System)를 이용하여 보정된 모델링 건물에 PMV 회귀모델 제어를 적용하였다. 단순 PMV 회귀모델과 Fanger PMV 모델 제어의 온열 쾌적도를 비교한 결과, 두 제어 모두 공조기간 동안 약 90% 이상이 온열쾌적 범위를 만족하였고, 온열 쾌적 제어의 특징인 설정 PMV를 만족하는 설정온도에 의하여 제어되는 것으로 나타났다.