• 제목/요약/키워드: PMV 환경

검색결과 85건 처리시간 0.023초

바닥온도와 실내 환기에 따른 인체반응 및 실내공기질 분석 (An Analysis of Human Reaction & IAQ Analysis by Changing the Floor Temperature & Ventilation)

  • 이지원;진경일;김세환
    • KIEAE Journal
    • /
    • 제15권1호
    • /
    • pp.97-102
    • /
    • 2015
  • Recently many buildings are airtight, deterioration takes the high stage. As this room ventilation is increasingly difficult, the importance of indoor air was emphasized. And Got a few provisions on the indoor ventilation, the building is used for other purposes also requires a lot of careful research. In this study, consisting of floor heating ventilation in the room and wants to know the impact on the human body react with the carbon dioxide concentration in the indoor air were investigated PMV. We have get the data through the experimental study like this. It can be inferred correlations of ventilation and temperature according to human comfort that you should consider when using the work of residential buildings in accordance with the changing social conditions and social. It is also determined that in the future through additional experiments related data can be established basic experimental data.

사무실 공간의 냉방시 천장 및 바닥 급기 공조 방식에 따른 열환경 평가 실험 (Experimental Analysis of Thermal Comfort of an Office Space for Ceiling and Floor Supply Air Conditioning Systems)

  • 조용;권혁승;김성현;김영일
    • 설비공학논문집
    • /
    • 제12권9호
    • /
    • pp.810-816
    • /
    • 2000
  • Thermal comfort plays an important role in modern office buildings. Four major factors affecting thermal comfort are air temperature, velocity, humidity and radiation temperature. Distribution of these thermal factors in indoor space depends largely on the air flow which is related to the method of supplying and extracting air. In this study, an experimental analysis on indoor thermal comfort is conducted to study the difference between a ceiling supply cooling system and a floor supply one. The two cooling systems are applied to an office space during summer season and the distributions of temperature, velocity, radiation temperature and PMV are measured. Results show that the floor supply cooling system is superior in terms of thermal comfort and energy saving. Studies need to be done, however, to reduce the vertical temperature difference of a floor supply air conditioning system.

  • PDF

여름철 열대야 발생시 탑상형 아파트의 실내온열환경에 대한 연구 (A Study on Indoor Thermal Environment in an Tower Type Apartment House at Tropical Nights)

  • 장현재;김형진
    • 설비공학논문집
    • /
    • 제22권1호
    • /
    • pp.20-25
    • /
    • 2010
  • In this study, As a basic research for improving indoor thermal environment at tower type apartment houses, specifications of heat storage and heat emission in the structures of apartment houses were investigated, and the ratio of indoor and outdoor air velocity at tower type apartment house was examined, too. Indoor temperature at night time was higher than outdoor air temperature because heat emission from the structure of wall, ceiling and floor those are constructed by use of reinforced concrete which has large heat capacity. The ratio of indoor and outdoor air velocity was lower than 0.1 and this was caused by the plan of tower type apartment house. PMV was in the range of 0.3~1.9, and was about 1.0 (it means slightly warm) at 10 : 00 p.m.. To improve indoor thermal environment in summer season at tower type apartment houses, it needs more investigation on specifications of heat storage and heat emission in the structure including winter season, and on the improvement of the ratio of indoor and outdoor air velocity.

A Comparison between In-situ PET and ENVI-met PET for Evaluating Outdoor Thermal Comfort

  • Jeong, Da-in;Park, Kyung-hun;Song, Bong-guen
    • KIEAE Journal
    • /
    • 제16권1호
    • /
    • pp.11-19
    • /
    • 2016
  • Purpose: PMV, PET, and similar thermal comfort indices and microclimate modeling have recently become actively used to evaluate thermal comfort. This study will look at pedestrian roads with diverse spatial characteristics on university campus using the ENVI-met model as the base for onsite measurement. Method: The PET was used as the thermal comfort index. The first microclimate measures were collected on September 20, 2014, and the second microclimate measures were collected on June 1, 2015. The ENVI-met model was used at the same time. Result: As a results, Onsite measurement results differed depending on the PET spatial characteristics. The location associated with the most discomfort had a PET of $47.8^{\circ}C$. The spatial characteristics of this place included a with no shade. The most comfortable location had shade, and the PET was $24.6^{\circ}C$. When the ENVI-met model and onsite measurements were compared, similar patterns were found, but with a few differences at specific points; this was due to the limitation of using input materials such as trees, buildings, and covering materials with the ENVI-met model. This factor must be thoroughly considered when analyzing modeling results.

교실 천장형 Unit의 위치에 따른 온열환경 평가 연구 (A Study on the Evaluation of Thermal Environment according to the Location of Ceiling Type Unit in Classroom)

  • 조성우;최정민;손영환
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.135-140
    • /
    • 2005
  • Installation of ceiling type unit is achieved by one of efforts for agreeable classroom environment embodiment along with economic growth. But research about changing the position of ceiling type unit is lacking in present. Therefore, this thesis is to study the thermal environment of 5 different position cases of ceiling type, namely Case A, B, C, D, E. Here, Case C is the case that has the position of ceiling type center of the classroom and the other 4 alternatives are 0.7 m away from the Case C according to x and z axis. In this thesis temperature distributions, air current distribution, heat amenities such as PMV of occupants are analyzed as the environmental factors. Through these factors, Case C and Case D are the better position alternatives than the alternatives of Case A, Case B and Case E because the latter cases the air current reaches directly to indoor occupants so that occupants feel chilly. This thesis has a conclusion under the condition of only one inlet air temperature and seat arrangement. But afterwards more inlet air condition and seat arrangement must be considered.

  • PDF

기류유인팬을 이용한 새 국립중앙박물관 로튠다에서의 열환경 평가 (Evaluation on Thermal Environment Installed Ventilating Fans in the Rotunda at New National Museum of Korea)

  • 이승철
    • 설비공학논문집
    • /
    • 제16권3호
    • /
    • pp.303-309
    • /
    • 2004
  • In order to improve thermal comfort in the Rotunda, which is high and wide visiting space of the new national museum of Korea, eight ventilating fans were installed near the ceiling of Rotunda. It has been analyzed thermal comfort of Rotunda with/without ventilating fans by numerical simulation. To evaluate thermal comfort of the Rotunda, well-known indices, PMV and PPD were introduced. The results of present investigation show that temperature distribution of the case with fans is closer to target temperature than the case with-out fans at the breathing zone. In the case without fans, thermal stratification with 16$^{\circ}C$ of temperature difference occurs along the height of the Rotunda which makes the thermal environment worse and the PPD values reach up to 50% in the 6th floor connection passage. In the case with fans, however, the vertical temperature difference were reduced to 9$^{\circ}C$ and the PPD values were lower below 20%. Consequently, the ventilating fans adopted on this study are effectively used for improving the thermal comfort in large space structure with thermal stratification.

실내수영장의 열, 기류 및 습도환경에 관한 연구 (A Study of Thermal, Air-flow and Humidity Conditions in an Indoor Swimming Pool)

  • 강석윤;이태구;문종선;이재헌
    • 설비공학논문집
    • /
    • 제15권8호
    • /
    • pp.683-689
    • /
    • 2003
  • The thermal comfort of an indoor swimming pool is different from that of general indoor space because of the characteristics of large space and the wear conditions of swimmers. Dew condensation by humid air not only makes mold on the floor, wall and roof but also decreases the durability of buildings by penetrating into their structures. In this study, the characteristics of the flow field, the temperature field and the humidity distribution in an indoor swimming pool have been examined by the numerical method to estimate the level of thermal comfort and the generation rate of dew condensation. The results showed that the dew condensation regions were spread widely at the eastern parts of the swimming pool due to the insufficient air flow rate with low velocity and temperature. To prevent the generation of dew condensation in a region, a sufficient warm air flow rate should be supplied to make an air mixing. The values of PMV at horizontal plane of 1.5 m height have the range of -1.0∼1.2, which means the suitable level for swimmers.

환경생태계획의 도시기후 변화 대응 가능성 연구 -남양주 월산리 마스터플랜을 중심으로 (A Study on the Urban climate Mitigation Effects with Ecological Landscape Planning with reference to Namyang-Ju Walsanli Master-plan)

  • 문수영;김현수;이광복
    • KIEAE Journal
    • /
    • 제10권6호
    • /
    • pp.11-19
    • /
    • 2010
  • To meet with the nation's policy of Green Growth, local governments are rushing to propose an ecological urban development plan. And although various studies stress on the need of ecological planning to harmonize development with preservation, we have come to a point in which a quantitative evaluation of how much ecological planning contributes to the environmental load is needed. Through the increasing tendency of making plans based on the development of IT technology, capability of gathering environmental data and scientific instrument, studies on ecological planning's effect towards environmental load has recently begun. This study aims to perform a quantitative evaluation on how ecological planning mitigate urban heat island in the region of Namyang-ju Wallsanli. Three theories were used to mitigate urban heat island ; White network, Green network and Blue network. As a result, the atmosphere temperature was reduced the whole site $1.1^{\circ}C$ and partly $7^{\circ}C$ and the mean radiant temperature was reduced the whole site $1.1^{\circ}C$ and partly $8.7^{\circ}C$ on the modified ecological landscape plan in summer. The PMV index is 0~1 in ecologically modified landscape plan otherwise almost 3 in landscape plan. This study has its limits on the fact that results may differ from the actual plan as the study was performed based on the land use plan and building plan. However, what is important is that it shows a quantitative result of the effect that ecological planning has on surrounding environment and reducing environmental load.

소음이 실내 온열감과 온열쾌적감에 미치는 영향 (Effects of Noise on Indoor Thermal Sensation and Comfort)

  • 양원영
    • KIEAE Journal
    • /
    • 제17권1호
    • /
    • pp.83-89
    • /
    • 2017
  • Purpose: Thermal sensation or thermal comfort was randomly used in many studies which focused on combined effects of thermal and acoustic environments on human perception. However, thermal sensation and thermal comfort are not synonyms. Thermal comfort is more complex human perception on thermal environment than thermal sensation. This study aims to investigate effects of noise on thermal sensation and thermal comfort separately, and also to investigate effects of temperature on acoustic sensation and comfort. Method: Combined thermal and acoustic configurations were simulated in an indoor environmental chamber. Twenty four participants were exposed to two types of noise (fan and babble) with two noise levels (45 dBA and 60 dBA) for an hour in each thermal condition of PMV-1.53, 0.03, 1.53, 1.83, respectively. Temperature sensation, temperature preference, thermal comfort, noisiness, loudness, annoyance, acoustic comfort, indoor environmental comfort were evaluated in each combined environmental condition. Result: Noise did not affected thermal sensation, but thermal comfort significantly. Temperature had an effect on acoustic comfort significantly, but no effect on noisiness and loudness in overall data analysis. More explicit interactions between thermal condition and noise perception showed only with the noise level of 60 dBA. Impacts of both thermal comfort and acoustic comfort on the indoor environmental comfort were analyzed. In adverse thermal environments, thermal comfort had more impact than acoustic comfort on indoor environmental comfort, and in neutral thermal environments, acoustic comfort had more important than thermal comfort.

재실자 활동량 산출을 위한 딥러닝 기반 선행연구 동향 (Research Trends for the Deep Learning-based Metabolic Rate Calculation)

  • 박보랑;최은지;이효은;김태원;문진우
    • KIEAE Journal
    • /
    • 제17권5호
    • /
    • pp.95-100
    • /
    • 2017
  • Purpose: The purpose of this study is to investigate the prior art based on deep learning to objectively calculate the metabolic rate which is the subjective factor for the PMV optimum control and to make a plan for future research based on this study. Methods: For this purpose, the theoretical and technical review and applicability analysis were conducted through various documents and data both in domestic and foreign. Results: As a result of the prior art research, the machine learning model of artificial neural network and deep learning has been used in various fields such as speech recognition, scene recognition, and image restoration. As a representative case, OpenCV Background Subtraction is a technique to separate backgrounds from objects or people. PASCAL VOC and ILSVRC are surveyed as representative technologies that can recognize people, objects, and backgrounds. Based on the results of previous researches on deep learning based on metabolic rate for occupational metabolic rate, it was found out that basic technology applicable to occupational metabolic rate calculation technology to be developed in future researches. It is considered that the study on the development of the activity quantity calculation model with high accuracy will be done.