• 제목/요약/키워드: PM10 Air Monitoring

검색결과 302건 처리시간 0.028초

Ambient Fine and Ultrafine Particle Measurements and Their Correlations with Particulate PAHs at an Elementary School Near a Highway

  • Song, Sang-Hwan;Paek, Do-Myung;Lee, Young-Mee;Lee, Chul-Woo;Park, Chung-Hee;Yu, Seung-Do
    • Asian Journal of Atmospheric Environment
    • /
    • 제6권2호
    • /
    • pp.96-103
    • /
    • 2012
  • Ambient particulate matter (PM) and particle-bound polycyclic aromatic hydrocarbon (PAH) concentrations were measured continuously for 70 days at a Korean elementary school located near a highway. The $PM_{10}$, $PM_{2.5}$, and $PM_1$ values were measured with a light-scattering, multi-channel, aerosol spectrometer (Grimm, Model 1.107). The number concentrations of the particles were measured using a scanning mobility particle sizer and counter (SMPS+C) which counted particles from 11.1 to 1083.3 nm classified in 44 channels. Particle-bound PAHs were measured with a direct reading, photoelectric aerosol sensor. The daily $NO_2$, $SO_2$, and CO concentrations were obtained from a national air-monitoring station located near the school. The average concentrations of $PM_{10}$, $PM_{2.5}$, and $PM_1$ were 75.3, 59.3, and $52.1{\mu}g/m^3$, respectively. The average number concentration of the ultrafine particles (UFPs) was $46,307/cm^3$, and the averaged particle-bound PAHs concentration was $17.9ng/cm^3$ during the study period. The ambient UFP variation was strongly associated with traffic intensity, particularly peak concentrations during the traffic rush hours. Particles <100 nm corresponded to traffic-related pollutants, including PAHs. Additional longterm monitoring of ambient UFPs and high-resolution traffic measurements should be carried out in future studies. In addition, transient variations in the ambient particle concentration should be taken into consideration in epidemiology studies in order to examine the short-term health effects of urban UFPs.

경기도 수원시 미세먼지 농도의 시계열모형 연구 (Analysis of time series models for PM10 concentrations at the Suwon city in Korea)

  • 이훈자
    • Journal of the Korean Data and Information Science Society
    • /
    • 제21권6호
    • /
    • pp.1117-1124
    • /
    • 2010
  • 미세먼지 농도는 국가의 중요한 환경 척도 중의 하나이다. 본 연구에서는 경기도 남부에 위치한 수원시 2003년-2009년 미세먼지 농도를 주위에서 쉽게 구할 수 있는 대기자료와 기상자료를 이용하여 자기회귀오차모형으로 월별로 분석하였다. 미세먼지 농도 분석을 위한 대기자료는 이산화황, 이산화질소, 일산화탄소, 오존 등을 사용했고, 기상자료로는 일 최고온도, 풍속, 상대습도, 강수량, 일사량, 운량을 사용하였다. 분석 결과, 자기회귀오차모형으로 월별 미세먼지 농도를 13%-49% 정도 설명할 수 있다.

서울시 지하철 구내의 공기중 분진 농도에 관한 연구 (A Study on Airborne Dust and Asbestos Concentrations in Subway Stations in Seoul Area)

  • 백남원;박두용;장익선;신용철;이정인
    • 한국환경보건학회지
    • /
    • 제14권2호
    • /
    • pp.1-12
    • /
    • 1988
  • Airborne dust and asbestos fiber concentrations were determined in subway stations located in Seoul area. Two stations, such as Eulchiro 4-Ka Station of Line #2, constructed during a period of 1980-1984 and Hyehwa Station of Line #4, opened in 1985, were selected. The results of the study are as follows. 1. Daily time-weighted average (TWA) concentrations of airborne dusts from 07:00 to 20:00 hours in Line #2 and Line #4 were 0.43$\pm$0.08 mg/m$^3$ and 0.37$\pm$0.12 mg/m$^3$, respectively. Thus, the dust levels in Line #2 were significantly higher than the levels in Line #4 (p < 0.05). 2. Dust levels in the morning (07:00-11:00 hours), noon (11:00-16:00 hours) and in the evening (16:00-20:00 hours) in Line #2 were 0.47$\pm$0.17 mg/m$^3$, 0.37$\pm$0.08 mg/m$^3$, and 0.46$\pm$0.07 mg/m$^3$ respectively. Thus, dust levels in the morning and evening (i.e., during rush hours) were significantly higher than levels in the noon (p < 0.02). However, there was no such difference in dust levels by time in Line #4. 3. Airborne total dust concentrations were well below the occupational health standard of 10 mg/m$^3$, however, the levels were exceeding the ambient air standard recommended by the Korean Environment Administration. 4. All of airborne asbestos fiber concentrations were equal to or below 0.005 fibers/cc. The levels are within both occupational health standards and U.S. EPA criteria. 5. A consideration should be given to the improvements of cleaning methods (such as use of vacuum cleaning instead of brushing) and the existing ventilation (such as more air change and filtration of supply air) for a reduction of dust levels. 6. It is recommended that routine monitoring of airborne dusts and asbestos fibers be conducted because more dusts and asbestos fibers can be produced in the air due to the deterioration of facilities by age and water damage in future.

  • PDF

건설업 옥외작업장 근로자의 미세먼지 노출 실태 조사 (Exposure of Outdoor Workers to Particulate Matter in Construction Sites)

  • 김승원;이가현;피영규;양원호;하권철;박현희
    • 한국산업보건학회지
    • /
    • 제27권1호
    • /
    • pp.46-58
    • /
    • 2017
  • Objectives: Particulate matter (PM) at construction sites mostly originates from either construction activities or the atmospheric environment. This study was conducted to evaluate the exposure level to PM and the contribution ratio of atmosphere sources at construction sites. Methods: We reviewed literature and governmental systems related to PM exposure in occupational settings and summarized them. In the field evaluation, five construction sites and one golf course were selected: two from Gyeonggi-do Province and four from North Gyeongsang-do Province. For each site, personal samples from outdoor construction workers and area samples from the outdoor area around the construction site office were collected according to construction work types. PM concentrations reported from nearby National Ambient Air Monitoring Stations were recorded. Respirable dust concentrations, respirable silica concentrations, and several metal concentrations including Cd, Cr, Pb, and As were monitored over four months. In the end we suggested how to manage particulate matter exposure at construction sites. Results: There was little literature reporting on exposure levels of construction workers to PM. Respirable dust concentrations measured in Gyeonggi-do Province were higher than those measured in North Gyeongsang-do Province. The geometric means of respirable dust concentrations in personal samples and area samples were $37.89{\mu}g/m^3$ and $92.86{\mu}g/m^3$, respectively. The respirable dust concentrations were higher than the PM concentrations reported from nearby National Ambient Air Monitoring Station. The geometric means of respirable silica concentrations of personal samples and area samples were $1.3{\mu}g/m^3$ and $1.1{\mu}g/m^3$, respectively. All metal concentrations were lower than 10% of individual Korean occupational exposure limits. Conclusions: Assuming that personal samples consisted of ambient PM and dust originating from work activities and area samples only collected ambient PM, we concluded that the dust exposure of outdoor construction workers originated 40.8% from the atmosphere and 59.2% from construction activities. PM exposure at construction sites should be controlled by employers, as in the case of outdoor heat stress. The Korean government needs to consider setting an occupational exposure limit for respirable dust.

통계분석을 이용한 광주지역 대기오염도 (An Assessment of Air Quality Using Statistical Analysis in Gwangju Area)

  • 서광엽;백계진;신대윤
    • 한국환경보건학회지
    • /
    • 제30권5호
    • /
    • pp.417-426
    • /
    • 2004
  • We investigate changing characteristics and concentration distribution of ambient air quality using data from which obtained local ambient air monitoring network and local meterological measuring sites in Gwangju area from January to December in 2003. Sulfur dioxide ($SO_2$) showed that increase from 8 AM and decrease in 6 PM but, it was not drastically changed concentration. it also 0.010 ppm in 1995 from at this time it's decrease step by step and than some constant in year 2001 to 2003. Nitrogen dioxide ($NO_2$) concentration was showed highest peak in 10 AM and increase again at 6 PM. And also it showed peak concentration (0.026 ppm) in 2001 and decreased from after that times. Ozone was showed peak concentration in 1 PM and Nitrogen dioxide was ditto in 10 AM from this data, we can conclude that this two article ws showed chemical reaction by 3 to 5 hours. There was no case of Ozone alarm in Gwangju area since 1995, but it showed highest ozone concentration (over 0.070 ppm) in May and June of the year and 2 to 4 PM of the day and sometimes it showed increase at the dawn. Ozone product optimum condition was that air temperature is over $25^{\circ}C$, no rain and increase solar radiation (over $20MJ/m^2$) and no wind or below 2.0 m/s wind speed.

전지구 대기질 재분석 자료의 평가와 국지규모 미세먼지 예보모델에 미치는 영향 (Assessment of Global Air Quality Reanalysis and Its Impact as Chemical Boundary Conditions for a Local PM Modeling System)

  • 이강열;이순환;김은지
    • 한국환경과학회지
    • /
    • 제25권7호
    • /
    • pp.1029-1042
    • /
    • 2016
  • The initial and boundary conditions are important factors in regional chemical transport modeling systems. The method of generating the chemical boundary conditions for regional air quality models tends to be different from the dynamically varying boundary conditions in global chemical transport models. In this study, the impact of real time Copernicus atmosphere monitoring service (CAMS) re-analysis data from the modeling atmospheric composition and climate project interim implementation (MACC) on the regional air quality in the Korean Peninsula was carried out using the community multi-scale air quality modeling system (CMAQ). A comparison between conventional global data and CAMS for numerical assessments was also conducted. Although the horizontal resolution of the CAMS re-analysis data is not higher than the conventionally provided data, the simulated particulate matter (PM) concentrations with boundary conditions for CAMS re-analysis is more reasonable than any other data, and the estimation accuracy over the entire Korean peninsula, including the Seoul and Daegu metropolitan areas, was improved. Although an inland area such as the Daegu metropolitan area often has large uncertainty in PM prediction, the level of improvement in the prediction for the Daegu metropolitan area is higher than in the coastal area of the western part of the Korean peninsula.

GIS 자료와 지상측정 기상·미세먼지 자료에 기반한 수원시 지역의 도시대기환경 특성 연구 (A Study on the Characteristics of the Atmospheric Environment in Suwon Based on GIS Data and Measured Meteorological Data and Fine Particle Concentrations)

  • 왕장운;한상철;문다솜;양민준;최석환;강은하;김재진
    • 대한원격탐사학회지
    • /
    • 제37권6_2호
    • /
    • pp.1849-1858
    • /
    • 2021
  • 본 연구에서는 2011년부터 2020년까지 수원시 내에서 측정한 기상과 미세먼지 농도 자료를 이용하여 월별, 연별 기상과 미세먼지 농도의 변화 경향을 분석하였고, 수원시 미세먼지 농도(PM10, PM2.5)와 기상 인자(풍속, 기온), 도시공간정보(건물부피비, 도로면적비) 간의 연관성을 조사하였다. 도시대기측정소의 도시공간정보를 산출하기 위해 국토지리정보원과 환경공간정보서비스에서 제공하는 수치지형도의 건물 고도 정보와 세분류 토지피복자료의 도로 정보를 이용하였고, 도시대기측정소를 중심으로 2 km×2 km 영역의 건물 부피와 도로면적을 계산하였다. 기상측정자료를 분석한 결과, 수원시는 주로 서풍과 서북서풍이 우세하게 나타났고, 평균풍속은 봄철에 높았다. 미세먼지 농도는 여름철(7월~9월)에 낮았고 봄철과 겨울철에 비교적 높았다. 연별 추이를 분석한 결과, 대부분의 지점에서 2020년에 미세먼지 농도가 가장 낮았다. 측정 미세먼지 농도는 풍속과 기온과 약한 음의 상관관계를 보였는데, 기온과 PM2.5 농도의 상관성이 상대적으로 높았다. 6개 도시대기측정소의 PM10, PM2.5 평균 농도와 도시매개수의 상관성을 조사한 결과, PM10 농도는 도로 배출이나 건물에 의한 지상 풍속 감소의 영향보다는 외부로부터의 유입 영향을 더 크게 받았고, PM2.5 농도는 국지적 배출이나 건물에 의한 풍속 감소 영향을 더 크게 받는 것으로 분석된다.

W-Station을 활용한 고밀도 초미세먼지 모니터링 연구: 제주도 사례 (A study on the monitoring of high-density fine particulate matters using W-station: Case of Jeju island)

  • 이종원;박문수;원완식;손석우
    • 한국입자에어로졸학회지
    • /
    • 제16권2호
    • /
    • pp.31-47
    • /
    • 2020
  • Although interest in air quality has increased due to the frequent occurrence of high-concentration fine particulate matter recently, the official fine particulate matter measuring network has failed to provide spatial detailed air quality information. This is because current measurement equipment has a high cost of installation and maintenance, which limits the composition of the measuring network at high resolution. To compensate for the limitations of the current official measuring network, this study constructed a spatial high density measuring network using the fine particulate matter simple measuring device developed by Observer, W-Station. W-Station installed 48 units on Jeju Island and measured PM2.5 for six months. The data collected in W-Station were corrected by applying the first regression equation for each section, and these measurements were compared and analyzed based on the official measurements installed in Jeju Island. As a result, the time series of PM2.5 concentrations measured in W-Station showed concentration characteristics similar to those of the environmental pollution measuring network. In particular, the results of comparing the measurements of W-Station within a 2 km radius of the reference station and the reference station showed that the coefficient of determination (R2) was 0.79, 0.81, 0.67, respectively. In addition, for W-Station within a 1 km radius, the coefficient of determination was 0.85, 0.82, 0.68, respectively, showing slightly higher correlation. In addition, the local concentration deviation of some regions could be confirmed through 48 high density measuring networks. These results show that if a network of measurements is constructed with adequate spatial distribution using a number of simple meters with a certain degree of proven performance, the measurements are effective in monitoring local air quality and can be fully utilized to supplement or replace formal measurements.

한반도 서부유입권역에서 대기 중 에어로졸 성분의 물리·화학적 특성 연구 III. 화학적 거동 및 장거리 이동 (Physico-chemical Characteristics of Submicron Aerosol at West Inflow Regions in the Korean Peninsula III. Physical-Chemical Behavior and Long-range Transport of PM1)

  • 박태현;안준영;최진수;임용재;박진수;김정호;오준;이용환;홍유덕;홍지형;최용주;이태형
    • 한국대기환경학회지
    • /
    • 제33권2호
    • /
    • pp.124-138
    • /
    • 2017
  • Physico-chemical measurement of non-refractory submicron particles($NR-PM_1$) was conducted in Baengnyeong Island, Korea using Aerodyne High Resolution Time of Flight Aerosol Mass Spectrometer (HR-ToF-AMS) from 2012 to 2014. Organics and ammoniated sulfate were dominant species in $NR-PM_1$. The organics was found to have similar fractions(approximate 40%) of $NR-PM_1$ during the summer and winter, while the sulfate fractions of $NR-PM_1$ were calculated to be approximately 47% and 31% for the summer and winter, respectively, suggesting the possibility that particles provide non-acidic surfaces for condensation of nitric acid in the winter. The nitrate fractions of approximate 4% and 20% of $NR-PM_1$ were observed in August (summer) and November (winter), respectively, resulting that the relatively low concentration of sulfate in $NR-PM_1$ provided a non-acidic surface for nitric acid condensation and formation of particulate ammoniated nitrate is favored thermodynamically in winter. The new particle formation (NPF) event and particle growth rate were analyzed for each month in 2014 using Scanning Mobility Particle Sizer(SMPS). The Percent of NPF events was the highest in winter, but NPF event was not observed during summer due to relatively high temperature and frequent rainfall. The average particle growth rate was 3.5 nm/h and the highest particle growth rate was 5.5 nm/h in May. We observed the long-range transport of the anthropogenic sulfate from the East Asia during the intensive monitoring period of November between Qingdao and Baengnyeong Island in 2013. The relatively high concentrations of m/z 60 measured in HR-ToF-AMS was observed in May and June at Baengnyeong Island, suggesting the possibility of the influence of biomass burning from the East Asia to the Korean Peninsula.

Comparison of Gene Mutation Frequency in $Tradescantia$ Stamen Hair Cells Detected after Chernobyl and Fukushima Nuclear Power Plant Accidents

  • Panek, Agnieszka;Miszczyk, Justyna;Kim, Jin-Kyu;Cebulska-Wasilewska, Antonina
    • 환경생물
    • /
    • 제29권4호
    • /
    • pp.373-378
    • /
    • 2011
  • Our aim was to investigate the genotoxicity of ambient air in the Krak$\acute{o}$w area after Fukushima Nuclear Power Plant (NPP) accident and compare with results from Chernobyl fallout. For the detection of ambient air genotoxicity the technique for screening gene mutation frequency in somatic cells of the $Tradescantia$ stamen hairs ($Trad$-SH assay) was used. Since 11th of March 2011 (Fukushima NPP accident), several pots containing at least 15 shoots of bioindicating plants were exposed to ambient air at 2 sites in the Krak$\acute{o}$w surrounding area, one in the city center, and about 100 pots in a control site (in the glasshouse of the Institute of Nuclear Physics) Continuous screening of mutations was performed. Progenies of 371,090 cells exposed were analyzed. Mutation frequency obtained in the first 10 days has shown a mean control level (GMF*100=$0.06{\pm}0.01$). At scoring period related to influence of a potential Fukushima fallout, a significant increase of gene mutation frequencies above the control level was observed at each site in the range, 0.10~0.33 depending on the location, (mean value for all sites GMF*100=$0.19{\pm}0.05$) that was associated with a strong expression of toxic effects. In the reported studies following the Chernobyl NPP accident monitoring $in$ $situ$ of the ambient air genotoxicity was performed in the period since April $29^{th}$ till June $3^{rd}$ 1986 also with Trad-SH bioindicator. In general, mutation frequency increases due to Chernobyl fallout(GMF*100=$0.43{\pm}0.02$) were corresponding to fluctuation of radioactivity in the air reported from physical measures, and to published reports about increase in chromosome aberration levels. Although, recent data obtained from monitoring of the ambient air quality in the Krak$\acute{o}$w and surroundings are lower when compared to results reported after Chernobyl NPP accident, though results express a significant increase above the control level and also are corresponding with increased air radioactivity reported from physical measurements. Statistically significant in comparison to control increase in gene mutation rates and more prolonged than that after Chernobyl fallout increase of GMF was observed during the period following the Fukushima NPP failure.