• 제목/요약/키워드: PM sampler

검색결과 166건 처리시간 0.03초

미국 서부 국립공원 지역의 미국 서부 국립공원 지역의 PM2.5에 대한 오염원 확인 및 기여도 추정 (Source Identification and Estimation of Source Apportionment of Ambient PM2.5 at Western National Park Site in USA)

  • 황인조
    • 한국대기환경학회지
    • /
    • 제26권1호
    • /
    • pp.21-33
    • /
    • 2010
  • The objective of this study was to estimate the $PM_{2.5}$ source apportionment at the Pinnacles National Monument IMPROVE site in western coastal USA. The PMF was applied to identify the existing sources and apportion the $PM_{2.5}$ mass to each source. To analyze local source impacts from various wind directions, the NPR analysis was performed using source contribution results with the wind direction values measured at the site. Also, PSCF was applied to identify the locations by point sources relative to the back trajectories. A total of 1,634 samples were collected from March 1988 to May 2004 by IMPROVE sampler and 32 chemical species were analyzed by PIXE, PESA, XRF, IC, and TOR methods. The PMF modeling identified seven sources and the average mass was apportioned to gasoline vehicle, secondary sulfate, aged sea salt, secondary nitrate, wood/field burning, diesel emission, and soil, respectively. In this study, the average mass was apportioned to gasoline vehicle (33.0%), secondary sulfate (25.7%), aged sea salt (17.8%), and secondary nitrate (10.1%). Also, this study suggests the possible role for source apportionment study of $PM_{2.5}$ at similar areas such as wildness, national park, and coastal areas in Korea.

서울시 PM-10 오염원의 정량적 기여도 추정 (Quantitative Source Estimation of PM-10 in Seoul Area)

  • 유정석;김동술;김윤신
    • 한국대기환경학회지
    • /
    • 제11권3호
    • /
    • pp.279-290
    • /
    • 1995
  • Recently in Korea, due to the significant drop of lead and bromine levels as a marker of autoemission source in the urban areas, the conventional application of receptor methods has many difficulties to properly apportion mass contribution of some sources. It is then needed to urgently develop alternative source profiles and identify new emission markers. Thus, the study has extensively examined the results obtained from using PAHs and elemental data for receptor modeling and has provided an opportunity to identify alternative source compositions and to determine a proper number of the ambient emission sources in Seoul area. The purpose of the study is to identify the sources of PM-10 and to estimate their mass contributions in Seoul area. Thus, a receptor model, target transformation factor analysis(TTFA) has been massively applied. The TTFA offers the possibility of determining the number of sources and their mass contributions. The input data used in this study are composed of two separate sets: fine (d$_{p}$ < 2.5.mu.m) and coarse (2.5.mu.m < d$_{p}$ < 10.mu.m) mode aerosol samples. Each sample was simultaneously collected by a PM-10 dichotomous sampler during the daytime(8 AM to 8 PM) and the nighttime(8 PM to 8 AM) from February to October 1993 on the Sungdong-Gu, Seoul. All the samples were analyzed to determine the levels of 10 inorganic elements by an XRF system as well as 14 PAHs by a HPLC. However, only 8 inorganic elements and 7 PAHs were used for the various statistical analysis.sis.

  • PDF

PMF를 응용한 구미시 PM-10 오염원의 정량적 기여도 추정연구 (Quantitative Estimation of PM-10 Source Contribution in Gumi City by the Positive Matrix Factorization Model)

  • 황인조;조영혁;최우건;이혜문;김태오
    • 한국대기환경학회지
    • /
    • 제24권1호
    • /
    • pp.100-107
    • /
    • 2008
  • The objective of this study was to quantitatively estimate PM-10 source contribution in Gumi City, Korea. Ambient PM-10 samples were collected by a high volume air sampler, which operated for 84 different days with a 24-h sampling basis, from June 14,2001 though May 19, 2003. The filter samples were analyzed for determining 13 inorganic elements, 3 anions, and a total carbon. The study has intensively applied a receptor model, the PMF (Positive Matrix Factorization) model. The results from PMF modeling indicated that a total of seven sources were independently identified and each source was contributed to the ambient Gumi City from secondary sulfate (34%), motor vehicle (26%), soil relation (5%), field burning (3%), industrial relation (3%), secondary nitrate (22%), and incinration (7%) in terms of PM-10 mass, respectively.

Evaluation of genotoxic potentials in diesel exhaust particulate matter with the Ames test, the comet assay and the micronucleus assay

  • Kim, Soung-Ho;Lee, Do-Han;Han, Kyu-Tae;Oh, Seung-Min;Chung, Kyu-Hyuck
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.1
    • /
    • pp.165.1-165.1
    • /
    • 2003
  • This research was designed to examine the presence of mutagenic/carcinogenic compounds in airborne pollutants in diesel particulate matter using an integrated biological approach. Respirable air borne particulate matter (PM2.5: <2.5mm) was collected from diesel engine exhaust using a high-volume sampler equipped with a cascade impactor. (omitted)

  • PDF

서울지역의 PM10 중 미량원소의 특성 평가 (Trace Elements Characterization of PM10 in Seoul Area)

  • 신은상;최민규;영선우;정용삼
    • 한국대기환경학회지
    • /
    • 제18권5호
    • /
    • pp.363-372
    • /
    • 2002
  • PM$_{10}$ aerosols were collected using low volume air sampler every month intervals from September 1992 to August 1991 in Seoul. These samples were analyzed for 20 trace elements (Al, As, Ba, Br, Ca, Cl, Co, Cr, Fe, K, Mn, Na, Ni, Pb, Sc, Se, Si, Ti, V and Zn) by INAA (instrumental neutron activation analysis), XRF (x-ray fuorescence spectrometer), and ICP (inductively coupled plasma). PM$_{10}$ mass concentrations higher than 70 $\mu$g/m$^3$ were 32% of 60 samples and had significantly higher concentrations in spring and winter than in summer and fall (p-value<0.001). The elements of As, Br, Cl, Ni, Pb, Se, V, and Zn are enriched by factors of 20 to 2,000 relative to their natural abundance in crustal soil. To further identify common sources of pollution-related trace elements, factor analysis was applied to the trace elements concentration data. Major sources that contribute to the atmospheric loading of these elements were found to include fossil fuel combustion, automobile and waste incineration (33.2%), metal processing industry (18.2%), and soil(29.8%).8%).

Digital 분진계와 개인용 분진 포집기의 측정값의 관계 (Relationship between the Measurement Values of the Digital Dust Indicator and Personal Dust Sampler)

  • 윤영노;이정주;정호근;최호춘
    • Journal of Preventive Medicine and Public Health
    • /
    • 제20권2호
    • /
    • pp.255-260
    • /
    • 1987
  • The digital dust indicator (Sibata P-5), one of the direct·reading instruments was evaluated for the respirable dust in the underground coal mine environments. As a reference, respirable dust was determined using three cyclones and/or impactors. All the tests were performed on aerosol in twenty underground coal mines. The coefficients of mass-relative concentration were $0.067{\pm}0.054$ (Mean$\pm$Standard deviation) (range: 0.006-0.172). The relationship between relative concentration and temperature was not significant statistically. Also, the relationship of relative concentration and relative humidity was not significant. Mass concentration and relative concentration were $5.31{\pm}5.22mg/m^3$ and $162{\pm}163$ CPM ($Mean{\pm}Standard$ deviation) respectively. The range of mass concentration was $1.22-22.69mg/m^3$; relative concentration 16-628 CPM. The relationship of mass concentration and relative concentration was not significant in these ranges.

  • PDF

제주도 고산에서의 1994년 여름 측정: (I) 입자 이온 조성 (Measurements at Kosan, Cheju Island during the Summer, 1994: (I) Aerosol Ion Composition)

  • 김용표;김성주;진현철;백남준;이종훈;김진영;심상규;강창희;허철구
    • 한국대기환경학회지
    • /
    • 제12권3호
    • /
    • pp.297-305
    • /
    • 1996
  • Aerosol measurements were carried out at Kosan, Cheju Island, Korea for the period from July 20 to August 10, 1994. Total suspended particles were collected by high volume samplers and PM 2.5 particles with gaseous volatile species were collected by a filter pack sampler and their ionic composition are analyzed. The average mass concentration of PM 2.5 particles was comparable to that of PM 3 particles collected during March, 1994 at the same site but the average non sea-salt sulfate concentration was higher that that of PM 3 particles, implying the fraction of anthropogenic air apllutants during this period is higher than that during March, 1994. During the measurement period, two distincitive patterns were observed, high concentrations of mass and water soluble ions were observed between July 20 and August 1 while those during after August 2 were low. Back trajectory analysis results show that air masses arriving at Kosan during the earlier period were mainly from Korea and Japan while those during the later period were from the North Pacific Ocean. It is suggested that the particle ion concentrations during the later period are marine background concentrations at Kosan during the summertime.

  • PDF

확산포집기로 공기중 ppb 농도수준의 휘발성유기물질 포집시 확산길이와 기류변화가 시료포집속도에 미치는 영향 (The effects of face velocity and path length on the uptake rates of volatile organic compounds measured by diffusive samplers)

  • 변상훈;톰 스톡;마리아 모란디;아프샤;제이 크로스
    • 한국산업보건학회지
    • /
    • 제11권1호
    • /
    • pp.34-41
    • /
    • 2001
  • Passive samplers have been used for personal, indoor, and outdoor air monitoring of VOCs at ppb concentrations in community and office environments. The path length of modified passive sampler was shortened, so it was intended to increase an uptake rate. The performance of the modified 3M 3500 organic vapor monitor(OVM) as a tool for assessing exposures to toxic air pollutants in nonoccupational community environments was evaluated using combined controlled test atmospheres of six selected target volatile organic compounds(VOCs): benzene, methyl tert-butyl ether(MTBE), chloroform, 1,4-dichlorobenzene, tetrachloroethylene, and toluene. The experiments were conducted by exposing the dosimeters to concentrations of $50{\sim}100{\mu}g/m^3$ on six face velocity(0.00, 0.02, 0.06, 0.12, 0.20, 0.30 m/sec) for 24 hours. If the uptake rate was increased, that means that we could use the passive sampler more effectively. The uptake rates were increased linearly according to reduce the path length. Although the diffusion path length was shortened, the change of uptake rate was within ${\pm}25%$ of theoretical value, indicating that the modified passive sampler(TM) can be effectively used over the range of concentrations and environmental conditions tested with a 24-h sampling period if the face velocities were over 0.12 m/s for 6 components of VOCs. But when the face velocities were less than 0.12 m/s, uptake rates were reduced more than expected values. So, the passive sampler with the shortened path length should be used at indoor or outdoor environment where the face velocity should be over about 0.10 m/s. If the path length was shortened more, the uptake rate was more effected by starvation.

  • PDF

서울시 일부 지역의 대기 중 미세먼지에 관한 연구 (A Study on Airborne Particulate Matter of a Local Area in Seoul)

  • 김성연;정문호;손부순;양원호;최경호
    • 한국환경보건학회지
    • /
    • 제31권4호
    • /
    • pp.301-308
    • /
    • 2005
  • The purpose of this study was to characterize mass concentration of $PM_{10}\;to,\;PM_{2.5}$ and metallic composition using Minivol Portable Sampler from May 2003 to May 2004 in metropolitan city, Seoul. Annual average concentration of $PM_{10}$ were $57.67({\pm}28.20)\;{\mu}g/m^3\;and\;PM_{2.5},\;were\;42.06({\pm}20.23)\;{\mu}g/m^3$. The concentration was the highest in winter because persistent thermal inversion and in spring, particulate matter concentration was high because of yellow-sand events. The average $PM_{2.5}/PM_{10}$ ratio was 0.73. This indicated $PM_{2.5}$ fraction played a significant role in air pollution. The atmospheric metallic elements in the $PM_{10},PM_{2.5}$ came different emission sources such as soil, traffic, industry and resuspended particles. The results showed that average $PM_{10}$ composition order as Fe>Zn>Pb>Cu>Mn. The metallic elements Zn and Fe were the largest composition in the $PM_{2.5}$

일부 병원 실내에서의 공기중 미생물 오염에 관한 연구 (A Study on Airborne Microorganism in Hospital)

  • 정선회;백남원
    • 한국산업보건학회지
    • /
    • 제8권2호
    • /
    • pp.231-241
    • /
    • 1998
  • To assess biological indoor air quality in hospital, concentrations of viable airborne microbes were determined at intensive care unit(ICU), patient room (PR), outpatient waiting room(OPWR) in hospitals of large(1000 beds), middle(500 beds), small(100 beds) hospitals, respectively. Gram positive bacteria, gram negative bacteria, fungi were sampled using suctional sampling method by RCS sampler (Reuter centrifugal air sampler) and RCS GK-A agar plate. In gram positive bacteria groups, CNS(Coagulase Negative Staphylococcus), Micrococcus, Lactobacillus, S. aureus, Enterococcus, St. viridans identified. In gram negative bacteria groups, A. baumannii, Kl. peumoniae and E. coli were identified, and Penicillium was identified in fugi groups. Results of the study were as follows. 1. The highest concentrations of airborne microbes was $971CFU/m^3$ at 5:00 PM in small hospital patient room, and average concentrations of airborne microbes in large, middle and small hospitals were $282CFU/m^3$, $289CFU/m^3$ and $625CFU/m^3$, respectively. Average concentrations of airborne microbes in office(control) was $90CFU/m^3$. Thus, the small hospital showed the worst condition. 2. Representatives of 8 different genera were identified in 150 samples. The most frequently isolated organisms were Staphylococcus (73.0%), Micrococcus (20.7%) and Lactobacillus (4.7%), respectively. Pathogenic microbes isolated were A. baumannii, E. coli, Enterococcus, Kl. peumoniae, S. aureus, St. viridans and Penicillium as fungi. In office, no pathogenic microbes were identified. Average concentrations of airborne pathogenic microbes in large, middle and small hospital were $5CFU/m^3$ (2%), $11CFU/m^3$ (4%) and $12CFU/m^3$ (2%), respectively. Thus, condition in a large hospital was better than those in a middle and a small hospital.

  • PDF