• 제목/요약/키워드: PM generator

검색결과 177건 처리시간 0.039초

해상용 3 MW 영구자석형 동기발전기의 대안설계 (Alternative Design of 3MW Offshore PM Synchronous Generator)

  • 김동언;이홍기;한홍식;정영규;서형석;정진화;임민수;곽승근;오만수;최준혁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.274-277
    • /
    • 2008
  • Pohang Wind Energy Research Center (PoWER-C) is developing a 3 MW Radial Flux Permanent Magnet (RFPM) Synchronous Generator for offshore Wind Energy Converter (WEC). The blade rotor rpm is 15.7 and the gear ratio is set to be 92.93. The nominal generator rpm at the rated load is about 1459. Baseline design with surface mounted PM magnets are completed. However, there is some concern about the excessive eddy current heating in the magnets. To alleviate this problem, another design with embedded magnet is going on. With embedded magnets, the generator length should be increased to compensate the increased flux leakage. But the field fluctuation in the magnets due to the slots are greatly reduced. This means less eddy currents and lower magnet operating temperature. In this report, engineering efforts for embedded rotor is presented.

  • PDF

소형 풍력용 슬롯리스 영구자석형 발전기에 관한 연구 (A Study of Slotless Permanent Magnet Generator for Small Wind Turbine)

  • 김형길;공정식;오진훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.981-982
    • /
    • 2011
  • This paper discusses design aspects of slotless permanent magnet generator for high performance and low speed applications. The airgap flux density in was obtained from finite element analysis and the design of a PM generator. The relatively large diameter stator laminations of such machines tend, therefore, to have a very thin back of core and narrow teeth, which make them expensive and difficult to manufacture. this thesis proposes an alternative PM generator topology featuring a slotless stator whose laminations are manufactured from a split core. The test results with a resistive load confirm the satisfactory operation of generator.

  • PDF

750kW gearless 풍력발전기 인버터 시험 (Test results of an inverter system for 750kW gearless wind turbine)

  • 손윤규;서재학;권세진;장성덕;오종석;황진수;강신일;박가우;권오정;정진화;한경섭;전중환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.59-63
    • /
    • 2005
  • The 800-kW PM (permanent magnet) synchronous generator is developed as a wind power generator. The matching converter is designed to control the torque and power depending on the wind speed regime. The generator starts to generate the power at the speed of 9 rpm and the rated output is generated at the speed of 25 rpm. The rated output power of an inverter is 750 kW when the PM synchronous generator is delivering 800 kW to the inverter. The inverter is specially designed to perform the maximum power point tracking (MPPT) at the low wind speed regime that is typical wind environment in Korea. The inverter test was done with a 2 MW M-G system at KERI (Korea Electric Research Institute). The M-G set has a 2 MW motor driver and a 38:1 gear to match the speed between the motor and the PM generator. The torque simulating the wind is applied to the PM generator by a DC motor. The test results show the inverter efficiency of $94.3\%$ at the rated power generating condition. The measured values show that the MPPT algorithm is working well. Overall reliability will be verified through the long-term site test.

  • PDF

계통연계 태양광발전시스템과 회전계자형 동기발전기의 병렬운전 특성 (Parallel Operation Characteristics of Utility Interactive Photovoltaic System and Revolving Field Type Synchronous Generator)

  • 류연수;유왕진;이철규;문종범
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.43-48
    • /
    • 2008
  • Through simulations and field experiment on A.C. parallel operation of both Utility Interactive Photovoltaic System and Diesel Engine Revolving Field Type Synchronous Generator, following factors have been found. First, the inverter should be operated in three modes of frequency(mode.1: ${\pm}$0.3Hz, mode.2: ${\pm}$1Hz, mode.3: ${\pm}$2Hz) as default, considering properties of operating Synchronous Generator. Second, as a result of supplying 13.5kW of residual power, it has been found that Synchronous Generator takes the power input only as reactive power, because it was electrically stable with frequency of 60.14Hz and high voltage of 222.3V even when power factor was -0.94. Besides, it was mechanically stable, too, because the quake, noise, and temperature of Synchronous Generator in this case were 7.5mm/s, 97dB, and $6^{\circ}C$ respectively, which were lower than normal load connection of 145.6kW; 11.03mm/s. Thus, load share of Revolving Field Type Synchronous Generator reduces according to the supply of Photovoltaic System to the load power. In this experiment, 200kW of Synchronous Generator and 40kW of Photovoltaic System were operated in parallel. The load share was 20% in maximum. and 11.1lit/hr of fuel was saved.

  • PDF

횡자속형 영구자석 풍력발전기 설계 및 특성해석 (Design and Performance Analysis of Axial-Flux Permanent-Magnet Generator for Wind Energy System Applications)

  • 황돈하;강도현;김용주;배성우;최경호;김동희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.949-951
    • /
    • 2002
  • Permanent-magnet (PM) synchronous generator is feasible for use with a wind turbine, because the generator for wind power requires variable-speed generation, light weight, and high torque. In this paper, basic design and construction of an axial-flux permanentmagnet generator with power output at 60 [Hz], 300 [r/min] for wind energy system is introduced. Finite-element method (FEM) is applied to analyze generator performance. In order to save time, equivalent analysis model is developed. The performance of the proposed generator at no-load and resistive load are compared, and power output and voltage at various speed and loads are compared as well. The results of FE analysis show that this PM generator is a useful solution for small-scale wind-turbine applications.

  • PDF

2중 공극형 횡자속 영구자석 동기발전기 설계 및 특성분석 (Design and Characteristics Analysis of Dual Air-Gap Axial-Flux type Permanent-Magnet Synchronous Generator)

  • 배성우;황돈하;강도현;김용주;최경호;김동희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1063-1066
    • /
    • 2003
  • This paper presents the design and characteristics analysis of axial-flux permanent-magnet (PM) synchronous generator of two air-gap. Dual axial-flux type PM synchronous generator commonly appears in applications where the generator axial dimension is more limited than the radial dimension. The strengths of dual axial-flux generator include ; (1) by employing two air-gaps, the rotor-stator attractive forces are balanced and no net axial or thrust load appeals on the generator hearings ; (2) heat produced by the stator windings appears on the outside of the generator, making it relatively easy to remove, and so on. In this paper, the simple magnetic equivalent circuit approach is used for initial design iteration, and the finite-element method is applied to analyze the detailed characteristics. The test results of driving characteristics are presented as well. The results are very similar to predicted performance of design.

  • PDF

미세먼지 간이측정기 현장 검사용 시험 입자 발생기 개발 및 성능 평가 (Development and performance evaluation of a test particle generator for a field inspection equipment of PM-2.5 sensors)

  • 정혁;박진수
    • 한국입자에어로졸학회지
    • /
    • 제18권3호
    • /
    • pp.61-68
    • /
    • 2022
  • In this study, a fluidized bed particle generator was developed to generate an aerosol without supply of compressed air and to increase portability. It was assumed that the mixing ratio of the test particles and beads, the input amount, and the air flow rate supplied to the generator would have effect on the aerosol generation characteristics. The product of these three parameters was set as a characteristic parameter and particle generation characteristics according to the change of the characteristic parameter were observed. As a result, it was confirmed that the input amount of test particles and beads was not suitable as a characteristic parameter and a characteristic parameter expressed as a product of the mass mixing ratio and the air flowrate was newly defined. When the new characteristic parameter is applied, it can be confirmed that the total amount of particles generated from the particle generator is a function of the characteristic parameter. As a result of measuring the amount of particle generation by adjusting the characteristic parameter, it was confirmed that the performance required for the test particle generator for the field inspection equipment of PM-2.5 sensors could be satisfied.

A Study of On-Chip Voltage Down Converter for Semiconductor Devices

  • Seo, Hae-Jun;Kim, Young-Woon;Cho, Tae-Won
    • 전기전자학회논문지
    • /
    • 제12권1호
    • /
    • pp.34-42
    • /
    • 2008
  • This paper proposes a new on-chip voltage down converter(VDC), which employs a new reference voltage generator(RVG). The converter adopts a temperature-independence reference voltage generator, and a voltage-up converter. The architecture of the proposed VDC has a high-precision, and it was verified based on a 0.25${\mu}m$ 1P5M standard CMOS technology. For 2.5V to 1.0V conversion, the RVG circuit has a good characteristics such as temperature dependency of only 0.2mV/$^{\circ}C$, and the voltage-up circuit has a good voltage deviation within ${\pm}$0.12% for ${\pm}$5% variation of supply voltage VDD. The output voltage is stabilized with ${\pm}$1mV for load current varying from 0 to 100mA.

  • PDF

Optimal Design of a Direct-Driven PM Wind Generator Aimed at Maximum AEP using Coupled FEA and Parallel Computing GA

  • Jung, Ho-Chang;Lee, Cheol-Gyun;Hahn, Sung-Chin;Jung, Sang-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권4호
    • /
    • pp.552-558
    • /
    • 2008
  • Optimal design of the direct-driven Permanent Magnet(PM) wind generator, combined with F.E.A(Finite Element Analysis) and Genetic Algorithm(GA), has been performed to maximize the Annual Energy Production(AEP) over the entire wind speed characterized by the statistical model of wind speed distribution. Particularly, the proposed parallel computing via internet web service has contributed to reducing excessive computing times for optimization.

횡자속형 영구자석 풍력발전기의 운전특성 해석 (Performance Analysis of Axial-Flux Permanent-Magnet Synchronous Generator for Wind Power Applications)

  • 황돈하;강도현;김용주;최경호;배성우;김동희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.143-145
    • /
    • 2003
  • In this paper, wind power system with direct-driven axial-flux type permanent-magnet (PM) synchronous generator, 10 [kVA], 300 [rpm], is presented. In order to analyze the performance of axial PM generator, finite-element (FE) analysis is used, and the 2-dimensional equivalent model is developed. The steady-state and transient-state characteristics are respectively analyzed at no-load and resistive-inductive loads. The test results of driving characteristics are presented as well. The results are very similar to predicted performance of design. Proposed generator is feasible for use with a small-class wind power applications.

  • PDF