• Title/Summary/Keyword: PM Template

Search Result 39, Processing Time 0.03 seconds

Template therapy for mouth opening limitation by temporomandibular joint disorders (턱관절원판 전방 변위로 인한 개구 장애의 템플레이트 치료)

  • Lee, Gi-Cheol;Shin, Seung-Woo;Pyo, Sung-Woon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.4
    • /
    • pp.270-274
    • /
    • 2010
  • Introduction: Limited mouth opening is a representative clinical symptom of temporomandibular disorders (TMD) with anterior disc displacement without reduction (ADDWOR). Various treatment methods have been proposed for patients with ADDWOR. This study examined the clinical effectiveness of template therapy for patients with mouth opening difficulty due to the ADDWOR. Material and Methods: A total of 14 patients (female 12, male 2, average age: $29.1{\pm}14.4$), who had been treated in the template clinic, Sooncheonhyang University Bucheon Hospital, from January of 2006 to December of 2008, were enrolled in this study. The subjects were selected according to the following criteria: more than 2 weeks after the onset of locking, mouth opening range <35 mm, and confirmed ADDWOR without a synovial pathology by magnetic resonance imaging (MRI). All patients were treated with the template appliance, instructed to wear it while sleeping and exercise for at least 10 hours per day. The maximum mouth opening (MMO) range and pain recognition scores before and after template therapy were recorded and compared. A paired t-test and Wilcoxon's signed rank test were used for statistical analysis. Results: After the periodical follow up, significant improvement in the opening range was observed in the template treatment group. The average MMO range before treatment was $30.2{\pm}3.5mm$ and the average MMO after treatment and follow up was $47.1{\pm}4.7mm$. The mean amount of mouth opening increment was $16.9{\pm}5.4mm$ (P<0.01) and the pain recognition scores before and after treatment was also improved.(P=0.001) Conclusion: The template appliance proved to be efficient for the treatment of TMD with a closed lock and painful joint due to ADDWOR.

Comparison of Visual- and Automatic Coregistration with MR Template based ROI Methods for Measurement of Specific Striatal Binding Ratio (SBR) in I-123 IPT SPECT

  • 주라형;서태석;최보영;이형구;김재승;문대혁
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.107-107
    • /
    • 2002
  • 목적: I-123 IPT SPECT에서 striatum에 ROI를 설정하여 Strial Binding Ratio를 측정하기 위해 사용되는 육안적인 방법과 MR Template based Coregistration 방법을 비교 평가하였다. 대상 및 방법: 파킨슨씨병 환자(IPD) 15명(남/녀:8/7, 63.3$\pm$4.8세)과 정상인 8명(남/녀:2/6, 61.4$\pm$16.5세) 에서 I-123 IPT(259MBq)를 주사한 후 2시간에 SPECT 영상을 얻었고 미상핵과 조가비핵의 전, 후부 및 후두엽에 각각 육안적인 방법과 MR Template based Coregistration방법으로 ROI를 설정하였다. MR Template based Coregistration 방법은 MNI TIMR template을 이용하여 SPECT영상을 voxel based intensity matching 방법으로 coregistration한 후midthalamic level에서 striatum의 경계를 따라 설정된 ROI를 이용하였다. 육안적인 방법은 striatal uptake가 가장 높은 level에서 3개의 ROI template를 striatum에 위치하였다. 두 방법으로 SBR과 nnterior/posterior ratio of SBR(APR)를 측정하였고 정상인과 파킨슨씨병 환자에서 두 방법을 비교하였다.

  • PDF

Usefulness of Registration in the Evaluation of Parkinson′s Disease (영상 융합하여 분석한 파킨슨씨병 환자영상의 유용성)

  • 주라형;김재승;문대혁;최보영;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.268-278
    • /
    • 2003
  • Purpose:The aim of this study was to evaluate the striatal binding ratio, the anterior/posterior ratio and reproducibility using a template based registration method using the standard MR template as a replacement for each patients MR image. Materials and Methods:This study analyzed the 123I IPT SPECT images of 30 patients with IPD, who were subdivided into 17 patients (56.6$\pm$10.8 yr, M/F : 8/9.) with mild IPD, and 13 patients (56.4$\pm$11.1 yr, M/F : 8/5) with severe IPD. In addition, 11 normal controls (57.8$\pm$14.4 yr, M/F : 4/7) were also analyzed. The ROIs were positioned manually in the same slice showing the highest striatal activity using the traditional manual method, whereas those were positioned automatically in a mid striatal slice of the SPECT image coregistered to the standard T1 weighted MR template. Results : The specific binding ratio (SBR) obtained using the template based registration method strongly correlated with those using the manual method in all groups : normal controls (r=0.85, P<0.001), mild IPD (r=0.84, P<0.001) and severe IPD (r=0.7, P=0.01). The SBRs obtained using both methods were significantly different among the three groups (P=0.05) and the SBRs obtained by the template based registration method were higher than those by the manual method (P=0.05) in all three groups. The APRs obtained by the template based registration correlated with those using manual method in only mild IPD (r=0.72, P=0.0). The APRs obtained by the template based registration method were significantly different from the normal controls and those with mild or severe IPD (P<0.05), whereas those obtained using the manual method were not significantly different among the three groups (P>0.1). The reproducibility (rmsCV) of the template based registration method was 7.2% (normal controls:5.2%, mild IPD:4.2%, severe IPD:10.8%), whereas the reproducibility of the manual method was 31% (normal controls:19.7%, mild IPD:21.7%, severe IPD:46.2%). Conclusion:These results show that the use of $^{123}$ I-IPT SPECT for assessing IPD is affected by the methods used to position the striatal ROI. The template based registration method using the standard MR template can be useful in diagnosing IPD and assessing the disease severity with a high reproducibility. Therefore, the template based registration method appears to be a good replacement for the manual method.

  • PDF

Development the Preventive Maintenance Template of the Nuclear Steam Turbine based on EPRI PMBD (EPRI의 예방정비기초자료에 근거한 원전 증기터빈의 예방정비기준 개발)

  • Lee, Byoung Hak;Lee, Hyuk Soon
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • The existing maintenance program is focused on time-based maintenance to inspect and repair components according to maintenance period, rather than condition-based maintenance or predictive maintenance. The preventive maintenance template of the steam turbine has been developed for optimizing maintenance procedure and improving reliability and availability of the steam turbine of nuclear power plants based on EPRI PM template methodology and EPRI technical reports about preventive maintenance.

  • PDF

A comparison with Result of Normalized image to Different Template image on Statistical Parametric Mapping of ADHD children patients (과잉행동장애 어린이의 SPM(Statistical Parametric Mapping)분석에서 서로 다른 Template image로 규격화된 SPEC 영상의 결과 비교)

  • Shin, Dong-Ho;Park, Soung-Ock;Kwon, Soo-Il;Joh, Chol-Woo;Yoon, Seok-Nam
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.71-78
    • /
    • 2003
  • We studied 64 ADHD children patients group($4{\sim}15\;ys$, mean age : $8{\pm}2.6\;ys$. M/F:52/12) and 12 normal group($6{\sim}7\;ys$, mean age : $9.4{\pm}3.4\;ys$, M/F:8/4) of the brain has been used to analysis of blood flow between normal and ADHD group. For analysis of Children ADHD, we used 12 children's mean brain images and made Template image of SPM99 program. In increase of blood flow(P-value 0.05), the result of normalized images to Template image to offer from SPM99 program, showed significant cluster in inter-Hemispheric and occipital Lobe, in the case of normalized images to children template image, showed inter-hemispheric and parietal lobe.

  • PDF

Driver's Eye Blinking Detection Method based on Template Matching using Line Profile (라인 프로파일을 이용한 템플릿 매칭 기반의 운전자 눈 깜박임 검출 방법)

  • Kim, Young Jae;Shin, Seung Seob;Kim, Kwang Gi
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.6
    • /
    • pp.873-881
    • /
    • 2017
  • Prevention of drowsy driving is one of the important issues for safe driving. In this study, the algorithm for detection of drowsy driving has been developed. The algorithm was implemented by applying template matching and line profile, which detects eye blink. The accuracy of eye detection and blink detection was $97.45{\pm}3.67%$ and $98.50{\pm}0.92%$, which was resulted from the verification experiment that 21 subjects participated. Consequently, the algorithm is expected to be used to prevent sleep-deprived driving.

Real-time Face Detection and Verification Method using PCA and LDA (PCA와 LDA를 이용한 실시간 얼굴 검출 및 검증 기법)

  • 홍은혜;고병철;변혜란
    • Journal of KIISE:Software and Applications
    • /
    • v.31 no.2
    • /
    • pp.213-223
    • /
    • 2004
  • In this paper, we propose a new face detection method for real-time applications. It is based on the template-matching and appearance-based method. At first, we apply Min-max normalization with histogram equalization to the input image according to the variation of intensity. By applying the PCA transform to both the input image and template, PC components are obtained and they are applied to the LDA transform. Then, we estimate the distances between the input image and template, and we select one region which has the smallest distance. SVM is used for final decision whether the candidate face region is a real face or not. Since we detect a face region not the full region but within the $\pm$12 search window, our method shows a good speed and detection rate. Through the experiments with 6 category input videos, our algorithm shows the better performance than the existing methods that use only the PCA transform. and the PCA and LDA transform.

Preparation of Nano Wire by Anodic Oxidation II. Production of Nano Wire Using Anodic Alumina Template (양극산화법에 의한 나노와이어 제조 II. 알루미나 템플레이트를 이용한 나노와이어 제조)

  • Jo, Su-Haeng;O, Han-Jun;Park, Chi-Seon;Jang, Jae-Myeong;Jo, Nam-Don;Ji, Chung-Su
    • Korean Journal of Materials Research
    • /
    • v.12 no.1
    • /
    • pp.89-93
    • /
    • 2002
  • To investigate the effect of properties of pores in anodic alumina template(AAT) on the formation and characteristics of metal nano wires, Cu and Ni nano wires were manufactured using anodic alumina template formed in various electrolytes. The characteristics of prepared metal nano wires using AAT could be replicated from those of pores in AAT. The diameters of nano wires could be controlled by the widening process of anodic porous film in $H_3PO_4$ solution. The shape ratio of the nano wire was shown to be $170{\pm}30$ for Ni nano wire formed by AAT made in sulfuric acid.

Implant Fixture Installation in the Anterior Mandible by Use of a Mucosa Supported Surgical Template Based on Computer Assisted Treatment Planning (컴퓨터보조 기반 점막지지 서지컬템프레이트를 이용한 하악전치부 임플란트 식립)

  • Lee, Jee-Ho;Kim, Soung-Min;Kim, Myung-Joo;Park, Jung-Min;Seo, Mi-Hyun;Myoung, Hoon;Lee, Jong-Ho;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.2
    • /
    • pp.158-165
    • /
    • 2011
  • A 73-year-old Korean female patient with a fully edentulous mandible was planned to have five implant fixtures installed in the anterior mandible for the fixed prosthesis. After 3-dimensional (3D) computed tomographic scanning was transferred to OnDemand3D$^{(R)}$ (Cybermed Co., Seoul, Korea) software program for the virtual planning, five fixtures of MK III Groovy RP implants of Branemark System$^{(R)}$ (Nobel Biocare AB Co., Goteborg, Sweden) were installed in the anterior mandible between both mental foramens using In2Guide$^{(R)}$ (CyberMed Co., Seoul, Korea) mucosa-supported surgical template with Quick Guide Kit$^{(R)}$ (Osstem Implant Co., Seoul, Korea) systems. Fixture installations were completed successfully without any complications, such as mental nerve injury, bony bleedings, fenestrations and other unexpected events. Postoperative computed tomographic scans were aligned and fused to the planned implant, then angular and linear deviations were compared with the planned virtual implants. The mean angular deviation between the planned and actual implant axes was $3.42{\pm}1.336^{\circ}$. The mean distance between the planned and actual implant at the neck area was $0.544{\pm}0.290$ mm horizontally and $0.118{\pm}0.079$ mm vertically. The average distance between the planned and actual implant at the apex area was $1.166{\pm}0.566$ mm horizontally and $0.14{\pm}0.091$ mm vertically. These results could be considered more precise and accurate than previous reports, and even our recent results. The entire procedures of this case are reported and reviewed.

Development of Source Template ICRT Dose Planning Software for Uterine Cervix Using the HDR: $^{192}Ir$ (강내조사를 위한 고선량률 근접조사 선원맞춤형 선량계획)

  • Choi, Tae-Jin;Oh, Young-Kee;Kim, Jin-Hee;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.112-118
    • /
    • 2009
  • The source position and source dwelling time in a given source arrangement in the applicators is very high effect to determine the expose time which in general is derived from the brachytherapy planning system. In high dose rate (HDR) intracavitary radiation therapy (ICRT), the treatment is often performed in based out-patient during the whole fractionation irradiations. However, the patient should be waited on coutch for ICR treatment in first start fraction as unconvinent and immobilized state until perform the dose plannings. In our experiments, the HDR source contributed dose for$55.89{\pm}4.20%$ for straight tandem source, $38.14{\pm}4.46%$ for the right ovoid soucre on the fornix and$5.97{\pm}0.50%$ for left ovoid source. It also showed the $60.33{\pm}6.53%$ for the tandem, $33.10{\pm}6.74%$ for right ovoid and $6.58{\pm}0.30%$ for the left ovoid source in 10 degrees of applicator. The authors designed the source template dose planning software for ICRT of uterine cervix results average $-0.55{\pm}2.15%$ discrepancy of the full charged brachytherapy dose planning. Developed Source temperate ICRT plaanning software guide a minimized the complains and operating times within a ${\pm}3%$ of dose discrepancies.

  • PDF