• Title/Summary/Keyword: PM(particulate matter)

Search Result 820, Processing Time 0.032 seconds

Flame Characteristics of Diesel Spray in the Condition of Partial Premixed Compression Ignition (부분 예혼합 압축착화 조건에서 디젤분무의 화염특성)

  • Bang, Joong Cheol;Park, Chul Hwan
    • Journal of the Korean Society of Combustion
    • /
    • v.17 no.2
    • /
    • pp.24-31
    • /
    • 2012
  • Diesel engines exhaust much more NOx(Nitrogen Oxides) and PM(Particulate Matter) than gasoline engines, and it is not easy to reduce both NOx and PM simultaneously because of the trade-off relation between two components. This study investigated flame characteristics of the partial premixed compression ignition known as new combustion method which can reduce NOx and PM simultaneously. The investigation was performed through the analysis of the flame images taken by a high speed camera from the visible engine which is the modified single cylinder diesel engine. The results obtained through this investigation are summarized as follows; (1) The area of the luminous yellow flame was reduced due to the decrease of flame temperature and even distribution of temperature. (2) The darkish yellow flame zone caused by the shortage of the remaining oxygen after the middle stage of combustion was considerably reduced. (3) Since the ignition delay was shortened, the violent combustion did not occur and the combustion duration became shortened.

Characteristics of Exhaust Emissions Reduction by Oxidation Catalyst for Light-duty Diesel Engine (산화촉매에 의한 소형디젤엔진의 배출가스 저감특성)

  • 김선문;임철수;엄명도;정일래
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.5
    • /
    • pp.411-417
    • /
    • 2002
  • The purpose of this study is to evaluate the emission reduction characteristics depending on the formation of the catalyst which influences the development of the diesel oxidation catalyst (DOC) suitable for small-sized diesel engines. We also attempted to suggest the feasibility of it as an after-treatment device. The reduction efficiency of DOC for CO and HC was proportional to the contents of precious metals, and the particulate matter (PM) has been reduced as much as 53∼59%. The reduction rate of soluble organic fraction (SOF) by DOC attachment revealed 100%. The composition of sulfate in PM increased from 3%, 7∼11% by installation of DOC. It is described that increase of sulfate contributed to the production of PM. This result also showed that the SOF and sulfate have trade-off relationship.

Composition and Size Variation of Airborne Fungal Spores in the Asian Dust Events (2000 ~ 2001)

  • Yeo, Hwan-Goo;Kim, Jong-Ho
    • Korean Journal of Environmental Biology
    • /
    • v.20 no.4
    • /
    • pp.294-299
    • /
    • 2002
  • PM (Particulate Matter) samples contained fungal spores were collected in the ambient air of Seosan, west Korea, in springtime of 2000 and 2001. PM concentrations were $199.8\mu{g}\;m^{-3}$ in the 1st Asian Dust Storm period (March, 23 ~ 24) and $249.4\mu{g}\;m^{-3}$ in the 2nd period (April, 7~9), 2000. Compared with the concentrations in 2000, relatively low PM concentration ($157.3\mu{g}\;m^{-3}$ ) was measured in the Asian Dust Storm period (April, 24 ~ 20) of 2001. Although there were somewhat differences for the total PM concentrations among the three periods, majorities of the PM were composed of coarse particles sized about 5 ~ 6 $\mu{m}$ over the periods of the two years. Diverse molds grown from fungal aerosols were observed in the PM samples and identified at the genus level. All the genera, Fusarium, Aspergillus, Penicillium, Basipetospora, Epicoccum and Monotospora are hyphomycetes in the division Fungi imperfecti (Deuteromycota). Especially, morphologically more diversified mycelia of hyphomycetes were grown on the fine PM sample (1.1 ~ 2.1 $\mu{m}$) than coarse PM samples in the periods of 2000. Furthermore, some molds were grown on even the background PM sample less than 0.43 $\mu{m}$ in the period of 2001. It was thought that some kinds of ultra fine sized fungal spores were transported by the Asian Dust Storm and suspended in the ambient air of study area during the events.

The Effects of PM10 on the Hospital Admission of Patients with Respiratory Disease in Seoul, Korea (서울지역 미세먼지가 호흡기계 질환으로 입원한 환자에 미치는 영향)

  • Pak, Hae-Yong;Pak, Yun-Suk
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.6
    • /
    • pp.194-201
    • /
    • 2019
  • This cohort study aimed to identify the effects of daily PM10 exposure on the hospital admission of patients with respiratory diseases, during the nine-year period (2002-2010), in Seoul, Korea. The research subjects were 13,974 patients who had been hospitalized with respiratory diseases, including chronic obstructive pulmonary disease (COPD), asthma, and pneumonia. During the follow-up period, an increase of 10 ug/m3 in PM10 under the threshold of 50 ug/m3 of PM10 led to hospital admission in 1.38% of the age group younger than 15 years, 1.62% in those 65 years or older, 2.87% in patients 75 years or older and in 1.50% of pneumonia patients, 1.51% of COPD patients, and 1.55% of pneumonia and asthma patients. Under the threshold of 80 ug/m3 of PM10, there was a 3.71% increase in new patients admitted in the age group 65 years or older and 4.25% in those at least 75 years old. Our study found that high PM10 was associated with increased risk of admission of respiratory patients, especially in the elderly. People who already have a respiratory disease should refrain from exposure to particulate matter when there is a high concentration of PM10, especially older patients.

Comparative Analysis of the CALPUFF and AERMOD Atmospheric Dispersion Models for Ready-Mixed Concrete Manufacturing Facilities Generating Particulate Matter (미세먼지 발생 레미콘시설에서의 대기확산모델 CALPUFF와 AERMOD 비교 분석)

  • Han, Jin-hee;Kim, Younghee
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.3
    • /
    • pp.267-278
    • /
    • 2021
  • Objectives: Using atmospheric dispersion representative models (AERMOD and CALPUFF), the emissions characteristics of each model were compared and analyzed in ready-mixed concrete manufacturing facilities that generate a large amount of particulate matter (PM-10, PM-2.5). Methods: The target facilities were the ready-mixed concrete manufacturing facilities (Siheung RMC, Goyang RMC, Ganggin RMC) and modeling for each facility was performed by dividing it into construction and operation times. The predicted points for each target facility were selected as 8-12ea (Siheung RMC 10, Goyang RMC 8, and Gangjin RMC 12ea) based on an area within a two-kilometer radius of each project district. The terrain input data was SRTM-3 (January-December 2019). The meteorological input data was divided into surface weather and upper layer weather data, and weather data near the same facility as the target facility was used. The predicted results were presented as a 24-hour average concentration and an annual average concentration. Results: First, overall, CALPUFF showed a tendency to predict higher concentrations than AERMOD. Second, there was almost no difference in the concentration between the two models in non-complex terrain such as in mountainous areas, but in complex terrain, CALPUFF predicted higher concentrations than AERMOD. This is believed to be because CALPUFF better reflected topographic characteristics. Third, both CALPUFF and AERMOD predicted lower concentrations during operation (85.2-99.7%) than during construction, and annual average concentrations (76.4-99.9%) lower than those at 24 hours. Fourth, in the ready-mixed concrete manufacturing facility, PM-10 concentration (about 40 ㎍/m3) was predicted to be higher than PM-2.5 (about 24 ㎍/m3). Conclusions: In complex terrain such as mountainous areas, CALPUFF predicted higher concentrations than AERMOD, which is thought to be because CALPUFF better reflected topographic characteristics. In the future, it is recommended that CALPUFF be used in complex terrain and AERMOD be used in other areas to save modeling time. In a ready-mixed concrete facility, PM-10, which has a relatively large particle size, is generated more than PM-2.5 due to the raw materials used and manufacturing characteristics.

A Study on the Factors Affecting the Air Environment in Chungnam Province - Focusing on Cheonan, Dangjin, and Seosan (충남 대기환경 영향요인에 관한 연구 - 천안, 당진, 서산 등을 중심으로)

  • Hwang, Kyu-Won;Kim, Jinyoung;Kwon, Young-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.118-127
    • /
    • 2021
  • Recently, the public's interest in the air environment has increased, and public health is threatened by fine particulate matter. Furthermore, the government continues efforts to improve air quality by expanding the monitoring of air pollutants and reinforcing environmental standards. Since air quality differs depending on the region in the Korean Peninsula, it is currently necessary to identify the cause and search for influencing factors. In this study, the atmospheric environment and regional differences in cities located in the Chungnam Province were observed. As a research method, regression analysis was performed for weather conditions, such as temperature, wind speed, precipitation, and season and targeted at air pollutants, such as SO2, NO2, CO, O3, PM10, and PM2.5, as well as heavy metals contained in particulate matter, such as Pb, Cd, Cr, Cu, Ni, As, Mn, Fe, Al, Ca, and Mg. In the case of PM10, the concentrations of Mn(0.4884) in Cheonan, CO(0.3329) in Dangjin, and Mg(0.5691) in Seosan were highest. In the case of PM2.5, Cheonan NO2(0.4759), Dangjin CO(0.4128), and Seosan NO2(0.3715) were significantly affected. In summary, the influencing factors vary according to the region in Chungnam province in terms of air quality, and there is a difference in the degree of contribution. Therefore, it is considered that the Korean government's management of air quality is required for each region.

The Effects of Diesel Exhaust Particulates and Particulate Matters on the Airway Remodeling in the Asthma-induced Mice (디젤분진 및 미세분진이 천식마우스에서 기도 재구성에 미치는 효과)

  • Li, Tianzhu;Lee, Soo-Jin;Jang, Yang-Ho;Park, Jun-Hong;Park, Se-Jong;Lee, Jeong-Hak;Choe, Nong-Hoon
    • Journal of Life Science
    • /
    • v.17 no.2 s.82
    • /
    • pp.248-253
    • /
    • 2007
  • This research investigated whether exposure of diesel exhaust particulate (DEP) and particulate matter (PM) effects on airway remodeling in asthma induced Balb/c and IL-10 knock out (KO) mouse. Mice were sensitized with intraperitoneal injection with ovalbumin, followed by challenges with intranasal ovalbumin. After that mice placed in inhalation chamber and exposed to DEP and $PM(10\;mg/m^3)$. The evidence of airway remodeling was assessed by masson's trichrome staining and PAS staining. The stainability of masson's trichrome and PAS reaction were increased in asthma-induced Baltic mice groups compared with control mice groups. More intensive stainability for masson's trichrome and PAS were appeared in the asthma-induced DEP and PM-exposed groups than asthama-induced groups. But, not significantly increased subepithelial fibrosis and the nember of goblet cell hyperplasia in asthma-induced IL-10 KO mice groups and asthma-induced+DEP and PM-exposed IL-10 KO mice than IL-10 KO mice groups. These results indirectly suggesting that exposure to DEP and PM in asthmatic patients might be aggravate clinical symptoms and IL-10 which seems to play a central role in allergic asthma. In conclusion, DEP and PM exposure might have additive effects on the ovalbumin- induced asthma in a murine model.

Development of a PM Sampler for Collecting Fine Particles via Condensation Magnification

  • Kim, D.S.;Kang, C.H.;Hong, S.B.;Lee, K.W.;Lee, J.H.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.E1
    • /
    • pp.24-31
    • /
    • 2008
  • In this study, a new PM (particulate matter) sampler was developed and fabricated to collect fine particles in the atmosphere, and laboratory and field tests were carried out to evaluate the performance of the sampler. The PM sampler, which was based on impingers, employed an aerosol condensation system as a PM magnifier to improve its collection efficiencies. Sodium chloride, ammonium sulfate and ammonium nitrate aerosols were used as test particles, because these components are rich in ambient aerosols. As a result, it was found that the collection efficiency of the novel PM sampler was very high. Thus, it is believed that the PM sampler is an effective device for sampling fine particles. In addition, it was demonstrated that this work could contribute to the collection or removal of fine particles and be applied to the semicontinuous sampling of ambient aerosols for chemical composition analysis.

A Study on Spatial Differences in PM2.5 Concentrations According to Synoptic Meteorological Distribution (종관 기상 분포에 따른 PM2.5 농도의 공간적 차이에 관한 연구)

  • Da Eun Chae;Soon-Hwan Lee
    • Journal of Environmental Science International
    • /
    • v.31 no.12
    • /
    • pp.999-1012
    • /
    • 2022
  • To investigate the reason for the spatial difference in PM2.5 (Particulate Matter, < 2.5 ㎛) concentration despite a similar synoptic pattern, a synoptic analysis was performed. The data used for this study were the daily average PM2.5 concentration and meteorological data observed from 2016 to 2020 in Busan and Seoul metropolitan areas. Synoptic pressure patterns associated with high PM2.5 concentration episodes (greater than 35 ㎍/m3) were analyzed using K-means cluster analysis, based on the 900 hPa geopotential height of NCEP (National Centers for Environmental Prediction) FNL (Final analysis) data. The analysis identified three sub-groups related to high concentrations occurring only in Busan and Seoul metropolitan areas. Although the synoptic patterns of high PM2.5 concentration episodes that occur independently in Busan and Seoul metropolitan areas were similar, there was a difference in the intensity of pressure gradient and its direction, which tends to be an important factor determining the movement time of pollutants. The spatial difference in PM2.5 concentration in the Korean Peninsula is due to the difference and direction of the atmospheric pressure gradient that develops from southwest to northeast direction.

Development of a High-Volume Simultaneous Sampler for Fine and Coarse Particles using Virtual Impactor and Cyclone Techniques

  • Okuda, Tomoaki;Shishido, Daiki;Terui, Yoshihiro;Fujioka, Kentaro;Isobe, Ryoma;Iwaki, Yusuke;Funato, Koji;Inoue, Kozo
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.1
    • /
    • pp.78-86
    • /
    • 2018
  • Filter-based sampling techniques are the conventional way to collect particulate matter, but particles collected and entangled in the filter fibers are difficult to be removed and thus not suited for the following cell- and animal-based exposure experiments. Collecting aerosol particles in powder form using a cyclone instead of a filter would be a possible way to solve this problem. We developed a hybrid virtual-impactor/cyclone high-volume fine and coarse particle sampler and assessed its performance. The developed system achieved 50% collection efficiency with components having the following aerodynamic cut-off diameters: virtual impactor, $2.4{\mu}m$; fine-particle cyclone, $0.18-0.30{\mu}m$; and coarse-particle cyclone, $0.7{\mu}m$. The virtual impactor used in our set-up had good $PM_{2.5}$ separation performance, comparable to that reported for a conventional real impactor. The newly developed sampler can collect fine and coarse particles simultaneously, in combination with exposure testing with collected fine- and coarse-particulate matter samples, should help researchers to elucidate the mechanism by which airborne particles result in adverse health effect in detail.