• Title/Summary/Keyword: PLC communication

Search Result 441, Processing Time 0.033 seconds

PLC monitoring and control system using the Internet (인터넷을 이용한 PLC 계측/제어 시스템)

  • 진선일;정진규;안광혁;유영동;홍석교;권오영
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.197-200
    • /
    • 2002
  • This paper is about a system development which control and monitor a PLC of the remote-distance through the Internet using the web-browser. In general, the PLC uses its own communication protocol of PLC Manufacture. It is actually impossible to be used through the Internet, because the PLC communication protocol is basically developed to be suitable for short-distance. Therefore, what we need is a transformation system which can convert the PLC communication protocol into the form which can connect to the Internet. In that sense, this paper is that about remote-control method through the WWW ( World Wide Web ). This system have three characteristics. First, it is possible to connect the Internet directly irrespective of CPU, Operating system and browser. Second, it is easy for user to access and treat. Third, it needs only HTML to operate without java or plug-in expansion. In this paper, we will introduce the monitoring and control system of PLC on the Linux with the Apache web-server.

  • PDF

Simulation of Power Line Communication Slient Node Problem Using OPNET

  • Huh, Jun-Ho;Seo, Kyungryong
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.3
    • /
    • pp.491-499
    • /
    • 2017
  • The Information & Communication Technology (ICT) and the Internet of Things (IoT) have become the major issues in Republic of Korea recently. While RS-232, Zigbee, and WiFi-related technologies are used in the ICT-based systems, we focus on the Power Line Communication (PLC) in this paper. By carrying out OPNET simulations, we've implemented the PLC Router Node Model, PLC Terminal Node Model, PLC Link Model, and PLC Palette Model and executed the simulations arranging 20 holds within the range of 400m (20m apart). As a result, we confirmed that the slient node problem had occurred at the point of 200m-2000m (as of 2016) distance preventing further communications. However, the control group, by contrast, was able to carry out the communications by installing a router. We expect that this paper will contribute to the development of a foundation technology which will saves costs by performing the simulation prior to building actual large-scale ICT Complex in the future work.

A Study on the development of Heating Facility Control and Remote Control System using Power Line Communication (PLC) (전력선 통신(PLC)을 이용한 난방기기 제어 및 원격제어 시스템의 개발에 관한 연구)

  • Kim, Yong-Tae;Shin, Kwan-Woo;Lee, Youn-Seop
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.65-67
    • /
    • 2001
  • PLC (Power Line Communication) is the communication method using the existing power line installed in houses and offices to convert and transmit high frequency communication signal from tens of KHz to tens of MHz, and receive the filtered signal using high frequency filter. The advantage of PLC is that PLC uses the existing power line installed in houses and offices so it does not require separate power line. Easy and convenient access using electric outlets is another advantage of PLC. However, PLC has some disadvantages such as limited transmission power, high load interference and noise, variable signal attenuation, characteristic of impedance selective possibility of frequency property. This study designed the boiler temperature control system by unit using the modem designed on the basis of technology used for PLC modem, and designed remote control system using internet. After conducting experiments with those two systems, it was possible to control stably. By commercializing this product, we can avoid unnecessary heating of separate temperature control unit, and save the cost according1y, and it is possible to control on a remote site using internet in a more convenient way.

  • PDF

A Shelter Guidance System using the PLC Communication (PLC 통신을 이용한 피난구 유도장치 시스템)

  • Lee, Chang-Young;Lee, Kyu-Yun;Lee, Hyun-Kwan;Kim, In-Kook;Eom, Ki-Hwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.583-586
    • /
    • 2005
  • We propose a shelter guidance system using the PLC communication to resolve that a conventional shelter guidance light for underground space has problems. The proposed shelter guidance system is composed of a main control part, a PLC remote control part, a charging part, a sound generation part, a display part, an alarm part and a smoke sensing part.. The efficacy of the proposed system is verified by means of experimental. Experimental results are presented that show the effectiveness and the improvement of noise.

  • PDF

Development of the High-Reliability PLC-CAN Communication Module for Construction Equipment (건설 중장비용 고신뢰성 PLC-CAN 통신 모듈 개발)

  • Ku, Ja-Yl;Jang, Se-Bong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.10
    • /
    • pp.228-234
    • /
    • 2014
  • In the case of construction equipment, internal wiring has a very complicated structure such as an electrical wiring and hydraulic equipments. Because of these complex wiring, a lot of time is spent on maintenance and equipment manufacturing. In this paper, we design and implementation of the high-reliability PLC(Power Line Communication) -CAN(Controller Area Network) communication module to reduce electrical wiring of the construction equipment.

Optimization for Relay-Assisted Broadband Power Line Communication Systems with QoS Requirements Under Time-varying Channel Conditions

  • Wu, Xiaolin;Zhu, Bin;Wang, Yang;Rong, Yue
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.10
    • /
    • pp.4865-4886
    • /
    • 2017
  • The user experience of practical indoor power line communication (PLC) applications is greatly affected by the system quality-of-service (QoS) criteria. With a general broadcast-and-multi-access (BMA) relay scheme, in this work we investigate the joint source and relay power optimization of the amplify-and-forward (AF) relay systems used under indoor broad-band PLC environments. To achieve both time diversity and spatial diversity from the relay-involved PLC channel, which is time-varying in nature, the source node has been configured to transmit an identical message twice in the first and second signalling phase, respectively. The QoS constrained power allocation problem is not convex, which makes the global optimal solution is computationally intractable. To solve this problem, an alternating optimization (AO) method has been adopted and decomposes this problem into three convex/quasi-convex sub-problems. Simulation results show the fast convergence and short delay of the proposed algorithm under realistic relay-involved PLC channels. Compared with the two-hop and broadcast-and-forward (BF) relay systems, the proposed general relay system meets the same QoS requirement with less network power assumption.

A multiple PLC wireless communication module using master-slave control concept (Mastey-Slave 개념을 이용한 PLC용 다대다 통신 모듈 개발)

  • 박종석;현웅근;김이곤
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.48-48
    • /
    • 2000
  • We developed a wireless communication system for multiple instrumentation system. The developed system has a function of remote instrumentation and PLC(Programmable Logic Controller) control. The system consists of CC(Control and Communication) protocol, wireless media access and physical media system. For multiple wireless communication, we propose a hub polling protocol based on master-slave control concept. To show the validity of the developed system, several experiments are illustrated.

  • PDF

A Investment on Wire-wireless Communication Method for Electrical Device Infrastructure Maintenance (전력설비 관리를 위한 무선 및 유선 통신 방법에 관한 고찰)

  • Kim, Young-Eok;Lee, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.2
    • /
    • pp.354-359
    • /
    • 2016
  • Power plants maintenance data is to be sent to management server system via a communication network. In this case, reliable communication network is required. Transmission of the power plants maintenance data is used in the wired communication network or wireless communication network. PLC communication network is a kind of wired communication network. However PLC communication network is easily affected by noise. On the vulnerable areas in power line system, such as a mountain or rural areas, it is difficult to form a power line communication network. For a wireless communication, environment are also influenced factors in wireless communication. Harsh environmental factors are bring the communication characteristic degradation. In such areas it can be used a combination of two networks and in this way the complementary function can be achieved. Power plants are distributed in various regions across the country. The appropriate communication network is needed to maintain the power plant.This study investigated the effect of environment on the wired communication and wireless communication. It would examine a variable factor which is affect to the communication characteristic. We used PLC communication for wired communication network and ZigBee communication for wireless communication network. We investigated the characteristics of a single communication network and it raised the need for a complex communication technology to complement a single communication network.

A development of multiple PLC communication module for near field control and measurement (근거리 원격 계측 및 제어를 위한 다중 PLC용 통신 모듈 개발)

  • 박종석;현웅근
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.661-664
    • /
    • 2000
  • A winless communication module for multiple PLC was developed. The function of the developed system are dual communication, concurrent multiple communication PLC control ,d interpretation of RC command, and A/D D/A converting. The multiple communication approach is based on master-slave control concept To show validity of the developed module, severial experiments are illustrated.

  • PDF

Iterative Coding for High Speed Power Line Communication Systems (고속 전력선 통신 시스템을 위한 반복 부호화 기법)

  • Kim, Yo-Cheol;Cho, Bong-Youl;Lee, Jae-Jo;Kim, Jin-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.5
    • /
    • pp.185-192
    • /
    • 2011
  • In this paper, we simulate and analyze performance of iterative coding scheme, double binary turbo code, for high speed power line communication (PLC) systems. PLC system has hostile environment for high speed data transmission, so error correction method is necessary to compensate effects of PLC channel. We employ the PLC model proposed by M. Zimmerman and Middleton Class A interference model, and system performance is evaluated in terms of bit error rate (BER). From the simulation results, we confirm double binary turbo code provides considerable coding gains to PLC system and BER performance is significantly improved as the number of iteration increase. It is also confirmed that BER performance increases as code rate is lager, while it decreases as the code rate is smaller.