• Title/Summary/Keyword: PLANTS FAULT

Search Result 160, Processing Time 0.022 seconds

Multihazard capacity optimization of an NPP using a multi-objective genetic algorithm and sampling-based PSA

  • Eujeong Choi;Shinyoung Kwag;Daegi Hahm
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.644-654
    • /
    • 2024
  • After the Tohoku earthquake and tsunami (Japan, 2011), regulatory efforts to mitigate external hazards have increased both the safety requirements and the total capital cost of nuclear power plants (NPPs). In these circumstances, identifying not only disaster robustness but also cost-effective capacity setting of NPPs has become one of the most important tasks for the nuclear power industry. A few studies have been performed to relocate the seismic capacity of NPPs, yet the effects of multiple hazards have not been accounted for in NPP capacity optimization. The major challenges in extending this problem to the multihazard dimension are (1) the high computational costs for both multihazard risk quantification and system-level optimization and (2) the lack of capital cost databases of NPPs. To resolve these issues, this paper proposes an effective method that identifies the optimal multihazard capacity of NPPs using a multi-objective genetic algorithm and the two-stage direct quantification of fault trees using Monte Carlo simulation method, called the two-stage DQFM. Also, a capacity-based indirect capital cost measure is proposed. Such a proposed method enables NPP to achieve safety and cost-effectiveness against multi-hazard simultaneously within the computationally efficient platform. The proposed multihazard capacity optimization framework is demonstrated and tested with an earthquake-tsunami example.

A Study on Setting SPS for Generator Tripping Action considering Operating Conditions of Power Systems (전력계통 운영조건을 고려한 발전기차단용 SPS 동작설정에 관한 연구)

  • Gwon, Han Na;Son, Hyeok Jin;Kook, Kyung Soo;Yang, Sung-Chae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.411-417
    • /
    • 2014
  • Special Protection Scheme(SPS) for generator tripping action is an emergency control tool that secures the power system stability by instantly tripping the pre-determined number of generators to avoid the acceleration of the remaining generators in a large-scaled power plants when a fault occurs on the drawing transmission lines. However, since the existing operating conditions of SPS are set based on a peak demand, SPS could trip more generators than required if it is activated during the off-peak demand period. For this, this paper proposes the algorithm for setting the operating conditions of SPS through the online stability evaluation with the periodically updated operating conditions of power systems. The proposed algorithm adopts COA for the accuracy and speed of the stability evaluation, and can reduce the number of tripping generators by SPS during the off-peak demand period. This results in reducing the loss of profit caused by a fault on power systems.

External and Internal Morphological Standard of original plants and herbal states in Pogostemonis and Agastachis Herba (광곽향(廣藿香)과 토곽향(土藿香)의 외부(外部) 및 내부형태연구)

  • Kim, Hong-Jun;Choi, Jeong;Ju, Young-Sung
    • Korean Journal of Oriental Medicine
    • /
    • v.12 no.2 s.17
    • /
    • pp.75-83
    • /
    • 2006
  • Pogostemonis and Agastachis Herba are the whole of Pogostemon cablin (BLANCO) BENTH or Agastache rugosa (FISCHER et MEYER) O. KUNTZE (family Labiatae) which is produced in all part of Korea and China. This drug is used for removing dampness by means of aromatics in oriental medicine. The standard formula of this drug is important from the viewpoint of the quality control. A characteristic discrimination of internal and external morphological standard in original plants and herbal states of Pogostemonis and Agastachis Herba are as follows. 1. The external characteristics: Pogostemon cablin has hairs and brown-like in stem, elliptical fruit. In the other hand, Agastache rugosa has no hairs and red-like in stem, obovatic trigone fruit. 2. The physical characteristics: Pogostemon cablin is gray in whole, has hairs in stem and numerous hairs of ash in leaf. In the other hand, Agastache rugosa is yellow-green in whole, has no hairs in stem. Specially the latter has deep-green colour and numerous hairs presenting mostly at lower epidermis in leaf. 3. The physical characteristics in currents: Pogostemon cablin is brown, has hairs and round-like stem. In the other hand, Agastache rugosa is green or yellow-green, has no hairs and tetragon in stem. 4. The internal characteristics: Pogostemon cablin has progressed spongy tissue in epidermal cell of leaf and many rank of epidermal cell in stem. In other hand, Agastache rugosa has 1 rank palisade tissue in leaf and few rank of epidermal cell in stem. In the external shape, it was possible that herbs were distinguished according to artificial classification and that same genus-degree of relatedness among herbs could be distinguished by more precise and active observation. In the shape of real herbs, I compared current herbs in market with original herbs which were just collected or were on the course of drying. In addition, it was possible that the internal shape could be identified by using microscope after butanol series. Though it was impossible to make distinction of herbs which are not current in my search contents, this search contents will be a standard for applying herbs in the future. An Additional standard establishment including physiochemical reaction and gene research is required in order to supplement the fault of this search.

  • PDF

Cable Functional Failure Temperature Evaluation of Cable Exposed to the Fire of Nuclear Power Plant (원자력발전소 케이블 노출 화재 시 기능상실온도 분석)

  • Lim, Hyuk-Soon;Bae, Yeon-Kyoung;Chi, Moon-Goo
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.10-15
    • /
    • 2012
  • The fire event occurred in fire proof zone often causes serious electrical problems such as shorts, ground faults, or open circuits in nuclear power plants. These would be directed to the loss of safe shutdown capabilities performed by safety related systems and equipments. The fire event can treat the basic design principle that safety systems should keep their functions with redundancy and independency. In case of a cable fire, operators can not perform their mission properly and can misjudge the situation because of spurious operation, wrong indication or instrument. These would deteriorate the plant capabilities of safety shutdown and make disastrous conditions. In this paper, investigation and cause analysis of cable fire in Nuclear Power Plant, we described the cable fire temperature and functional failure criteria and the cable functional failure temperature evaluation by exposed fire is studied.

On discrete nonlinear self-tuning control

  • Mohler, R.-R.;Rajkumar, V.;Zakrzewski, R.-R.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1659-1663
    • /
    • 1991
  • A new control design methodology is presented here which is based on a nonlinear time-series reference model. It is indicated by highly nonlinear simulations that such designs successfully stabilize troublesome aircraft maneuvers undergoing large changes in angle of attack as well as large electric power transients due to line faults. In both applications, the nonlinear controller was significantly better than the corresponding linear adaptive controller. For the electric power network, a flexible a.c. transmission system (FACTS) with series capacitor power feedback control is studied. A bilinear auto-regressive moving average (BARMA) reference model is identified from system data and the feedback control manipulated according to a desired reference state. The control is optimized according to a predictive one-step quadratic performance index (J). A similar algorithm is derived for control of rapid changes in aircraft angle of attack over a normally unstable flight regime. In the latter case, however, a generalization of a bilinear time-series model reference includes quadratic and cubic terms in angle of attack. These applications are typical of the numerous plants for which nonlinear adaptive control has the potential to provide significant performance improvements. For aircraft control, significant maneuverability gains can provide safer transportation under large windshear disturbances as well as tactical advantages. For FACTS, there is the potential for significant increase in admissible electric power transmission over available transmission lines along with energy conservation. Electric power systems are inherently nonlinear for significant transient variations from synchronism such as may result for large fault disturbances. In such cases, traditional linear controllers may not stabilize the swing (in rotor angle) without inefficient energy wasting strategies to shed loads, etc. Fortunately, the advent of power electronics (e.g., high-speed thyristors) admits the possibility of adaptive control by means of FACTS. Line admittance manipulation seems to be an effective means to achieve stabilization and high efficiency for such FACTS. This results in parametric (or multiplicative) control of a highly nonlinear plant.

  • PDF

Towards the Application of Safety Integrity Level for Improving Process Safety (공정안전향상을 위한 Safety Integrity Level의 적용 방향)

  • Kwon, Hyuck-Myun;Park, Hee-Chul;Chun, Young-Woo;Park, Jin-Hyung
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.5
    • /
    • pp.64-69
    • /
    • 2012
  • The concept of SIL is applied in the most of all standards relating to functional system safety. However there are problems for the people to apply SIL to their plants. as these standards don't include sufficient informations. In this regards, this paper will suggest the direction of SIL application and concept based on IEC 61508 and IEC 61511. A Safety Integrity Level(SIL) is the discrete level(one out of possible fours), corresponding to a range of the probability of an E/E/PE (Electric/Electrical/Programmable Electrical) safety-related system satisfactorily performing the specific safety functions under all the stated conditions within a stated period of time. SIL can be divided into the target SIL(or required SIL) and the result SIL. The target SIL is determined by the risk analysis at the analysis phase of safety lifecycle and the result SIL is calculated during SIL verification at the realization phase of safety lifecycle. The target SIL is determined by the risk analysis like LOPA(Layer Of Protection Analysis), Risk Graph, Risk Matrix and the result SIL is calculated by HFT(Hardware Fault Tolerance), SFF(Safe Failure Fraction) and PFDavg(average Probability of dangerous Failure on Demand). SIL is applied to various areas such as process safety, machinery(road vehicles, railway application, rotating equipment, etc), nuclear sector which functional safety is applied. The functional safety is the part of the overall safety relating to the EUC and the EUC control system that depends on the correct functioning of the E/E/PE safety-related systems and other risk reduction measures. SIL is applied only to the functional safety of SIS(Safety Instrumented System) in safety. EUC is the abbreviation of Equipment Under Control and is the equipment, machinery, apparatus or plant used for manufacturing, process, transportation, medical or other activities.

Development of a Computer Code for Common Cause Failure Analysis (공통원인 고장분석을 위한 전산 코드 개발)

  • Park, Byung-Hyun;Cho, Nam-Zin
    • Nuclear Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.14-29
    • /
    • 1992
  • COMCAF, a computer code for the common-cause failure analysis, is developed to treat the common-cause failures in nuclear power plants. In the treatment of common-cause failures, the minimal cut sets of the system are obtained first without changing the fault-tree structure. The occurrence probabilities of the minimal cut sets are then calculated accounting for the common-cause failures among components in the same minimal cut set or in different minimal cut sets. The basic parameter model is used to model the common-cause failures between similar or identical components. For dissimilar components, the assumption of symmetry used in the basic parameter model is applied to the basic events affecting two or more components. The top event probability is evaluated using the inclusion-exclusion method. In addition to the common-cause failures of components in the same minimal cut sets, failures of components in the different minimal cut sets are also easily accounted for by this method. This study applied this common-cause failure analysis to the PWR auxiliary feedwater system. The results in the top event probability for the system are compared with those of no common-cause failures.

  • PDF

An Implementation of Realtime Remote-Monitoring System for Distributed Photovoltaic Power Plants (분산형 태양광 발전 시스템을 위한 실시간 원격 모니터링 시스템 구현)

  • Kim, Chang-Joon;Kim, Jung-Ki;Jang, Kyung-Sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.10
    • /
    • pp.2450-2456
    • /
    • 2015
  • In this paper, we propose a real-time remote monitoring system for distributed solar power generation system. The proposed system consists of PVC, UTC, OTC and monitoring server. PVC collects the operational information from the PV's inverter via serial interface. The sensing data is transmitted to the server by wireless communications and stored in the DB server. The PV's status is monitored via UTC, and the operating of PVC and UTC are managed by OTC. In addition, by providing information about the power generated by PV system and failure diagnosis in real time, the proposed system shows the possibility of reducing the maintenance costs and improved failure recovery time.

Process Hazard Review and Consequence Effect Analysis for the Release of Chlorine Gas from Its Storage Tank (염소저장탱크에서의 가스 누출시 공정위험검토 및 결과영향분석)

  • Ko, Jae-Sun;Kim, Hyo
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.61-73
    • /
    • 2003
  • Most of the accidents occurred from the chemical plants are related to the catastrophic gas release events when the large amount of toxic materials is leaked from its storage tank or transmitting pipe lines. In this case, the greatest concerns are how the spreading behaviors of leakages are depended on the ambient conditions such as air stability and other environmental factors. Hence, we have focused on the risk assessments and consequential analysis for chlorine as an illustrative example. As appeared in the result, Fire & Explosion Index depicted it a bit dangerous with presenting the comprehensive degrees of hazard 90.7. And as a result of Phast6.0/ALOHA, the trends of each scenario appeared considerably identical although there are some differences in the resulting effects according to the input data for the Gas Model. The consequence analysis is performed numerically based on the dense gas mode. In the future, using more correct input data, material properties, and topographical configuration, the method of this research will be useful for the guideline of the risk assessment when the release of toxicants breaks out.

A study on the advanced method of aging manufacturing factory (노후화된 제조공장의 고도화 방법에 관한 연구)

  • Kim, Jeong-Min;Jang, Jong-Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.69-71
    • /
    • 2018
  • Looking at Korea's manufacturing industry, there are many old manufacturing plants. In fact, the manufacturing process of the product inventory management and the unit price of the product are all created by using Excel, and the factory is operated by using it. Also, the operator can not predict the failure of the equipment in order to produce the product at work. Problems related to this may result in the loss of the documents during the instruction and work process between the manager and the worker, and the communication between the manager and the worker can not be properly performed, There is appear a situation in which the operation is continued by using the equipment without recognizing in the failure. In this paper, we propose a method for upgrading the aging manufacturing plant to improve the productivity and productivity of the product by predicting the efficient inventory management, unit price management, production volume, and the operator's failure prediction.

  • PDF