• 제목/요약/키워드: PIV technique

검색결과 318건 처리시간 0.029초

편광기법을 이용한 수직교차평면의 PIV 속도장 동시측정 (Simultaneous Measurements of Velocity Fields at Two Vertically Crossing Planes by PIV Systems Using Polarization Technique)

  • 권성훈;윤상열;김경천
    • 한국가시화정보학회지
    • /
    • 제2권1호
    • /
    • pp.32-38
    • /
    • 2004
  • A new PIV technique was developed for decreasing optical error which was created during simultaneous measurements of velocity fields at a wall-normal plane and wall-parallel plane by a plane PIV and a Stereo-PIV systems. For experimental study, two different Reynolds number based on momentum thickness, Re$_{ =514 and 934 were generated in a blowing type wind tunnel under the condition of zero pressure gradient. The two Nd:Yag laser systems and three CCD cameras were synchronized. to obtain instantaneous velocity fields at the same time. To avoid optical noise at the crossing line by the two laser light sheets, a new optical arrangement using polarization was applied. The obtained velocity fields show the existence of hairpin packet structure vividly and the idealized hairpin vortex signature is confirmed by experiment.

  • PDF

Visualization of micro-interfacial conditions using Micro PIV

  • OKAMOTO Koji;SHINOHARA Kyosuke;SUGII Yasuhiko
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 Proceedings of 2004 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.111-118
    • /
    • 2004
  • A new micro-resolution PIV (Particle Image. Velocimetry) has been developed. To investigate transient phenomena in a microfluidic device, Dynamic micro-PIV system was realized by combining a high-speed camera and a CW(Continuous Wave) laser. The technique was applied to a micro-counter-current flow, consisting of water and butyl acetate. The velocity fields of water in the micro counter-current flow were visualized for a time resolution of 500 $\{mu}s$ and a spatial resolution of 2.2 x 2.2 $\{mu}m$. Using the Dynamic micro-PIV technique, the vortex-like motions of fluorescent particles at the water-butyl acetate interface were captured clearly

  • PDF

PIV를 이용한 다수원주 주위 유동장 해석 (Flow Field Analysis around Multi-Cylinders Using Particle Image Velocimetry)

  • 전완수;박준수;권순홍;하동대;최장운;이만형
    • 한국해양공학회지
    • /
    • 제10권3호
    • /
    • pp.89-95
    • /
    • 1996
  • The flow field around four cylinders for various angles was investigated utilizing particle image velocimetry(PIV) technique. Flow field was recorded by video camera first. Then application of PIV technique was done to the flow field. The results turned out to be useful to analyze complex flow field around multiple cylinders.

  • PDF

Industrial Applications of PIV/PTV Velocity Field Measurement Techniques

  • Lee Sang Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2001년도 Proceedings of 2001 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.23-35
    • /
    • 2001
  • Due to advances in digital image processing, computer and optical hardware, it is possible to extract full flow information from visualized flow images. Recently, the PIV/PTV methods have been accepted as a reliable velocity field measurement technique. In my laboratory, several velocity field measurement techniques have been developed and they were applied to various thermo-fluid flow problems. In this paper, some of the industrial applications will be discussed. As a result, the PIV/PTV technique was proved to be a powerful tool for industrial fluid flow diagnosis.

  • PDF

PIV기법을 이용한 정사각 실린더의 후류에 관한 실험적 연구 (An Experimental Study on the Wake of a Square Cylinder Using PIV Technique)

  • 이종붕;장태현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권1호
    • /
    • pp.124-135
    • /
    • 2004
  • An experimental study is performed turbulent flow behind a square cylinder by using 2-D PIV technique. The Reynolds number investigated are 10.000. 30.000 and 50,000. The mean velocity vector, time mean axial velocity turbulence intensity. kinetic energy and Reynolds shear stress behind the cylinder are measured, The numerical method used this study is a CFD code, STAR-CD. The numerical results are compared with these of experimental.

몰수실린더에 의하여 생성되는 쇄파주위 점성유동의 고찰(제3부 : PIV를 이용한 순간유동장 해석) (On the Viscous Flow Around Breaking Waves Generated by a Submerged Cylinder(Part 3 : Survey of Flow Field Using PIV Technique))

  • 현범수;신용헌;최경신
    • 대한조선학회논문집
    • /
    • 제37권2호
    • /
    • pp.38-45
    • /
    • 2000
  • 본 연구는 PIV 기법을 사용하여 쇄파와 몰수체의 상호작용에 의한 점성유동장의 변화를 가시화 함과 아울러 순간유동장을 해석하는데 목적을 두고 수행하였다. 몰수깊이의 변화에 따른 쇄파와 실린더의 상호작용은 S/D=1.5 정도에서 부터 감지되기 시작하여 몰수깊이가 얕아질수록 상호작용이 크게 발생하였으며 S/D=1.0 이하가 되면 쇄파로 인한 와류가 실린더로부터 유기되는 와류를 압도하여 실린더 후방의 전반적인 와도분포를 심하게 변형시킴을 알 수 있었다. 이로부터 PIV 기법은 와도분포 해석과 같은 비정상 보오텍스 유동장의 해석에 매우 유용한 방법임을 확인하였다.

  • PDF

PIV의 성능개선에 관한 연구 (A Study on the Improvement of PIV Performance)

  • 이영호;김춘식;최장운
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권3호
    • /
    • pp.34-42
    • /
    • 1994
  • The present study is aimed to improve the PIV performance by suggesting a two-frame particle identification technique and by introducing estimation method of wall pressure distribution from the velocity data. Adopted image processing system consists of one commercial image board slit into a personal computer, 2-D sheet light generator, flow picture recording apparatus and related particle identification software. A revised particle tracking method essential to PIV performance is obtained by particle centroid correlation pairing (CCP) and its effectiveness is ascertained by comparison with multi-frame identification.

  • PDF

단일 카메라 입자영상유속계를 이용한 이상유동 기포율 측정방법 (On the Measurement Technique of Void Fraction by Single Camera Two Phase PIV)

  • 최동환;성재용;유정열
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1558-1563
    • /
    • 2004
  • A measurement technique for the void fraction and the bubble dynamics in gas-liquid two-phase flows has been proposed using a time-resolved two-phase PIV system. For the three-dimensional evaluation of the bubble information, both the images from the front and side views are simultaneously recorded into a high speed CCD camera by reflecting the side image into the front view with the help of a $45^{\circ}$ oriented mirror. Then, a stereo-matching technique is applied to calculate the void fraction, bubble size and shape. To obtain the rising bubble velocities, the 2-frame PTV method was applied. Consequently, the present technique shows good feasibility for the measurements of the volume fractions, mean diameters, aspect ratios and velocities of the bubbles at the three-dimensional point of view.

  • PDF

Stereoscopic PTV 기법의 개발과 성능비교 연구 (Development of Stereoscopic PTV Technique and Performance Tests)

  • 이상준;윤전환
    • 대한기계학회논문집B
    • /
    • 제30권3호
    • /
    • pp.215-221
    • /
    • 2006
  • A stereoscopic particle tracking velocimetry (SPTV) technique based on the 2-frame hybrid particle tracking velocimetry (PTV) method was developed. The expansion of 2D PTV to SPTV is facilitated by the fact that the PTV method tracks individual particle centroids. To evaluate the performance and measurement accuracy of the present SPTV technique, it was applied to flow images of rigid body translation and synthetic standard images of jet shear flow and impinging jet flow. The data processing routine and measurement uncertainty of the SPTV technique are compared with those of conventional stereoscopic particle image velecimet.y (SPBV). In addition, the centroid translation effect of 2D particle image velocimetry (PIV) is defined and its effect on SPIV measurements is discussed. Compared to the SPIV method, the SPTV technique has inherited merits of concise and precise velocity evaluation procedures and provides better spatial resolution and measurement accuracy.

단일 광경로 스캔PIV기법의 개발 (Development of single optical axis scanning PIV method)

  • 김형범;정인영;이상혁;류청환
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2005년도 추계학술대회 논문집
    • /
    • pp.6-10
    • /
    • 2005
  • PIV(Particle image velocimetry) presents the flow velocity of whole flow fields in a fraction of a second. Conventional PIV method uses two optical axis configuration during the image grabbing process. That is, the illumination plane and the recording plane must be parallel. This configuration is very natural to grab the whole field without the image distortion. In the real problem, it is often to meet the situation which this configuration is hard to be fulfilled. In this study, we developed new PIV method which only uses single optical axis to grab the particle images. This new PIV method become possible by utilizing the scanning method similar to echo PIV technique. One particle image of scanning PIV consists of scanned several line images and by repeating this scanning process, two particle images were grabbed and processed to produce the velocity vectors.

  • PDF