• Title/Summary/Keyword: PIV method

Search Result 320, Processing Time 0.028 seconds

An Experimental Study on Flow Characteristic around a Flap rudder (플랩러더 주위의 유동특성에 관한 실험적 연구)

  • Gim, Ok-Sok;Cho, Dae-Hwan;Lee, Gyoung-Woo;Ko, Jae-Yong
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.11a
    • /
    • pp.277-282
    • /
    • 2006
  • The purpose in having a control surface on a ship is to control the motion of the ship. The control surface may be composed entirely of a single movable surface or of a combination of fixed and movable portion A control surface has one sole function to perform in meeting its purpose, and that is to develop a control force in consequence of its orientation and movement relative to the water. The forces and moments generated as a result of this rotation and angle of attack then determine the maneuvering characteristics of the ship. In this paper the study of flapped rudder's 2-dimensional section was accomplished. Model tests had been carried out with different angles of attack of a main foil and flap's deflection angles to predict the performance of the flapped rudder and the 2 frame particle tracking method had been used to obtain the velocity distribution in the flow field $Re=2.8\times10^4$ had been used during the whole experiments and measured results had been compared with each other.

  • PDF

A Fundamental Study on Lower Duct Flow of passive anti-rolling tanks System (수동형 감요수조의 하부덕트 유동에 관한 기초연구)

  • Lee, Cheol-Jae;Lim, Jeong-Sun;Jung, Han-Sic;Jung, Hyo-Min
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.11a
    • /
    • pp.265-269
    • /
    • 2006
  • Anti-Roll Tanks, also called Sloshing Tanks, is a rather common and sometimes an efficient method of limiting the roll angles. The important parameters, when considering using anti-roll tanks, are positioning, size, duct area, flow control device etc. Measurement by the PIV(Particle Image Velocimetry) was conducted to investigate the flow characteristics around control damper and inlet area of duct for three kind of inclined angle $(\alpha=0^*,\;10^*\;and\;20^*)$. Flow behaviors such as instantaneous and time-mean velocity vectors are investigated. Furthermore, to reveal boundaries between flowing and stagnant zones and to extract velocity profiles at any selected sections of the lower duct for passive anti-rolling tanks system.

  • PDF

Effect of Pressure Gradients on the Hairpin Structures in Turbulent Boundary Layers (난류 경계층의 Hairpin와 구조에 대한 압력구배의 영향)

  • Kim, Gyeong-Cheon;Yun, Hong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.8
    • /
    • pp.1103-1112
    • /
    • 2001
  • The effect of pressure gradients on the hairpin structures in three different turbulent boundary layers (ZPG : Re(sub)$\theta$=910, FPG : Re(sub)$\theta$=575, APG : Re(sub)$\theta$=1290) has been examined with instantaneous velocity fields obtained in streamwise-wall-normal planes using PIV (particle image velocimetry) method. In the outer layer hairpin vortices occur in streamwise-aligned packets that propagate with small velocity dispersion. The signature pattern of the hairpin consists of a spanwise vortex core located above a region of strong second quadrant fluctuation (u<0 and v>0 : Q2 event) is clearly observed. The formation of packets explains the occurrence of multiple VITA events in turbulent burst. Noticeable differences are found in the average inclination angles of hairpin vortex packets which are 45$^{\circ}$, 35.7$^{\circ}$, and 51.9$^{\circ}$in the case of ZPG, FPG and APG, respectively. It is found that the large, time-varying, irregularly shaped zones with nearly constant streamwise momentum exist throughout the boundary layer. Within the interior of the envelope the spatial coherence between the velocity fields induced by the individual vortices leads to strongly retarded streamwise momentum, explaining the zones of uniform momentum. The formation of the uniform momentum zone is remarkably different with respect to the pressure gradients especially in the logarithmic layer.

The Change of Flow Characteristics in Lateral Aneurysm Models for Different Coil Locations (코일 위치에 따른 측방 동맥류 내부 혈류 유동의 변화)

  • 이계한;송계웅;변홍식
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.375-383
    • /
    • 2002
  • Aneurysm embolisation method using coils have been widely used. Micro coils are introduced via a small catheter, and are packed inside of aneurysm sac, which induces intraaneurysmal flow stagnation and thrombus formation. When partial blocking of an aneurysm is inevitable, the location of coils is important since it changes the flow patterns inside the aneurysm, which affect the embolisation process. We measured the flow field inside the partially blocked lateral aneurysm models in vitro, and tried to suggest the effective locations of coils for aneurysm embolisation. Velocity fields are measured using a particle image velocitimeter for different coil locations- proximal neck, distal neck, proximal dome and distal dome. Flow into the aneurysm sac was significantly reduced in the distally blocked models, and coils at distal neck blocked inflow more effectively comparing to those at distal dome. This study suggests that distal neck should be the most effective location for aneurysm embolisation.

A Study on the Flow Analysis according to the change of Surface Roughness Gap in the Leisure Ship (레저선박의 표면조도 간격변화에 따른 유동해석에 관한 연구)

  • Oh, Woo-Jun;Cho, Dea-Hwan;Lee, Dong-Sub;Shon, Chang-Bae;Lee, Gyoung-Woo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2009.10a
    • /
    • pp.243-244
    • /
    • 2009
  • From large to small vessels of the surface is not smooth. and The surface ship has a surface roughness. Because surface roughness increases the surface resistance and heat transfer, be considered when designing a ship that is an important design factor. Due to surface roughness study on flow around and due to changes in flow and turbulence intensity for the ongoing research is conducted. Roughness of the surface ships from the ship by air as well as machines can be widely applied. In this study, the surface roughness of the leisure marine interval, any change will affect the surface flow, area due to surface roughness for boundary-experimental study was performed.

  • PDF

Flow Characteristics in a Real Scale Vegetation Patch using LSPIV Method (LSPIV 기법을 이용한 실규모 식생패치에서의 흐름특성)

  • Kim, Sung Jung;Kim, Hyung Suk;Ko, Dong Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.279-279
    • /
    • 2019
  • 본 연구는 안동 하천실증연구센터에서 수행된 RIED 실험의 일환으로 실험수로내 식재된 버드나무 식생패치의 밀도에 따른 표면흐름의 특성을 검토하는 실험이다. 실험의 목적은 식생의 침수수위에 따른 식생주변 및 하도의 흐름특성을 검토하는 것으로 침수 수위조건은 유량공급조건의 변화를 통해 재현하였다. 본 연구에 사용된 LSPIV 기법은 하도내 입자투여를 통해 영상을 이용하여 입자간 이동속도를 분석하여 흐름장을 분석하는 것으로 본 연구에서 사용된 입자는 강랭이를 사용하였으며, 영상촬영은 크레인을 이용하여 캠코더를 이용하여 수로 상부에서 흐름영상을 취득하였다. 실험수로는 저면폭 3m, 만제폭 11m 사면경사 1:2의 구조로 이루어진 사다리꼴 형태의 직선수로로 이루어져 있다. 식생패치는 동일수로내 상부기준 32m 간격으로 설치되어 있으며 패치의 크기는 $4{\times}1.5m$의 크기로 이루어져 있다. 그림 1은 상공에서 촬영된 영상을 나타낸 그림으로 실험수로 및 LSPIV 분석을 위해 투하된 입자를 나타내는 그림이다. PIV 분석프로그램을 이용하여 분석된 식생대 및 하도영역에서의 유속장은 그림 2와 같다. 영상분석은 30초영상(900 frame)을 이용하여 분석하였다. 실험결과 식생패치 설치지점에서는 주흐름이 발생하는 우안측에서 높은 유속이 발생하고 약간의 편향된 흐름이 나타나는 것으로 확인되었다. 식생후면에서는 식생으로 인한 흐름의 차단 및 스크린효과로 인해 유속의 저감되는 것을 확인할 수 있다. 밀도에 따른 패치 후면부에서는 높은 밀도를 갖는 첫 번째 패치에서 유속의 저감효과가 높게 나타났으나 유량조건에 차이가 발생하는 것으로 나타났는데 이는 수위상승으로 인한 식생의 침수면적과 관계가 있는 것으로 판단된다.

  • PDF

Diagnostic Performance of Blood Culture Bottles for Abscess Culture in Patient with Abdominal Soft Tissue Abscess (복부 연조직 농양 환자에서 농양 배양을 혈액배양병으로 했을 때의 성과 1예)

  • Jo, Kyo Jin;Chang, Chulhun L.;Hwang, Jae-Yeon;Park, Su Eun
    • Pediatric Infection and Vaccine
    • /
    • v.28 no.2
    • /
    • pp.118-123
    • /
    • 2021
  • Culture tests are very important in choosing the appropriate antibiotics for bacterial infections. In some cases, bacteria that could not be identified in standard culture bottles could be detected using blood culture bottles. A previously healthy 13-year-old boy visited our emergency room. He experienced pain, redness, and hardness of periumbilical skin and a fever for five days. There was no history of abdominal surgery and penetrating trauma. Computed tomography showed abscess with cellulitis at the periumbilical soft tissue with no congenital anomaly. Ultrasonography-guided aspiration was performed, and about 8.5 mL of the purulent abscess was aspirated. The abscess was cultured using blood culture bottle. The pus grew Actinomyces radingae and Clostridium ramosum. When performing the pus culture, using blood culture bottles can be more effective and rapid than the standard culture method for the detection of bacterial pathogens.

Study on Evaluation Method of Flow Characteristics in Steady Flow Bench(3) - Velocity Profile(1) (정상유동 장치에서 유동 특성 평가 방법에 대한 연구(3) - 유속분포(1))

  • Park, Chanjun;Sung, Jaeyong;Ohm, Inyong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.2
    • /
    • pp.169-182
    • /
    • 2016
  • This paper is the third investigation on the evaluation methods of flow characteristics in a steady flow bench. In the previous works, several assumptions used in the steady flow bench were examined and the flow characteristics were estimated both by the conventional impulse swirl meter and a particle image velocimetry at 1.75B position. From these works, it was concluded that the assumption of the solid rotation might cause serious problems and both of the eccentricity and the velocity profile distort the flow characteristics when using the ISM at 1.75B plane. Therefore, the understanding of the detail velocity profiles is very important to keep discussing the issues about the steady flow evaluation method. For this purpose, the planar velocity profiles were measure at 1.75B position by particle image velocimetry and the characteristics were examined according to the valve angles and lifts. The results show that the planar velocity profiles of 11, 16, $21^{\circ}$ valve angle heads according to the lift are similar to each other, however, that of $26^{\circ}$ angle is an exceptional case in the all aspects. In addition, the swirl behaviors are not apparent up to 6~8 mm lift under the $21^{\circ}$ angle and somewhat arranged motions are observed over the whole plane near the highest lift. At this point, the narrower the angle, the lower the lift at which the swirl motions become clear. On the other hands, when the angle is $26^{\circ}$, the center of swirl is always farthest from the cylinder center and only the indistinct swirl is observed even if at the highest lift. Also, all the swirl centers are quite apart from the cylinder center so that the effect of eccentricity may not be negligible at 1.75B regardless the valve angle. Related to the tangential velocity along with the radial direction, the bands of the velocity distribution are very wide and the mean velocities of cylinder center basis are lower than the velocity which is assumed in the ISM evaluation. Lastly, the mean tangential velocity profiles of swirl center basis are sometimes higher than that of ISM-assumed up to 0.6 non-dimensional distance less than 6mm lift, however, as the lift increases the profiles are different according to the angles and profile $11^{\circ}$ is the most closed to the ideal profile. Consequently, the real velocity profile is far from the assumption of ISM evaluation.

Establishment and Application of a Multibead Serotyping Assay for Pneumococci in Korea (다중구슬 폐구균 혈청형 분석법의 국내 확립과 적용 연구)

  • Kim, Han Wool;Lee, Soyoung;Lee, Miae;Kim, Kyung-Hyo
    • Pediatric Infection and Vaccine
    • /
    • v.22 no.2
    • /
    • pp.97-105
    • /
    • 2015
  • Purpose: Serotyping pneumococcal isolates is important to monitor efficacy of pneumococcal vaccines. Because of difficulties of typing pnueumocci, a multiplex bead-based (multibead) serotyping assay was recently introduced. The aim of this study is to establish a new multibead serotyping assay and to apply this method to analyze clinical isolates of pneumococci in Korea. Methods: To establish the multibead serotyping assay, six key reagents were transferred from University of Alabama at Birmingham (UAB) to Ewha Center for Vaccine Evaluation and Study (ECVES): bead set coated with polysaccharide and monoclonal antibody pool were used in one multiplex inhibition-type immunoassay and 2 bead sets coated DNA probe and 2 primer pools were used in two multiplex PCR-based assays. After multibead serotyping assay was set up, 75 test samples of pneumococci were analyzed whether ECVES is able to identify serotype correctly. After confirming the performance, serotyping assay was applied to identify serotypes of 528 clinical isolates of pneumococci collected from 3 different hospitals. Results: After establishment of the multibead pneumococcal serotyping assay system at ECVES, 75 test samples were analyzed. There was no discrepancy of serotypes of 75 test samples between the results assigned at UAB and those at ECVES. The serotypes of 528 pneumococci isolated from patients or healthy subjects were determined in 94.3% of isolates (498/528). Conclusions: The multibead pneumococcal serotyping assay can be successfully established in Korea. With this method, surveillance of serotypes of pneumococci isolated from patients as well as healthy subjects could be studied.

Discordance between Tuberculin Skin Test and Interferon-gamma Release Assays for Diagnosis of Tuberculosis Infection in Korean Children (국내 소아 결핵감염 진단에서의 결핵피부반응 검사와 Interferon-gamma Release Assay (IGRA)의 비교 연구)

  • Yoo, Reenar;Kim, Joon-Il;Kim, Seohee;Lee, Jina
    • Pediatric Infection and Vaccine
    • /
    • v.23 no.1
    • /
    • pp.18-24
    • /
    • 2016
  • Purpose: There is a the great diagnostic challenge in pediatric tuberculosis especially in high burden setting. The purpose of this preliminary study is to evaluate the agreement between tuberculin skin test (TST) and interferon-gamma release assay (IGRA) including T-SPOT$^{(R)}$.TB and QuantiFERON$^{(R)}$-TB Gold (QFT-G) in Korean children. Method: This retrospective study included children and adolescents who visited to Asan Medical Center to evaluate tuberculosis infection using at least two assays of TST, T-SPOT.TB and QFT-G, from January 2014 to April 2015. Results: A total of 20 patients were included, whose median age was 13.3 years (range, 3.8-18.1 years), and all of them had history of BCG vaccination. Eleven patients had underlying diseases including 7 patients with immunosuppressant medication. The concordance rate between T-SPOT.TB and QFT-G was 90%. However, the concordance rate between TST and T-SPOT.TB was 50%, and between TST and QFT-G was 42.9%. Specificity for the diagnosis of tuberculosis infection of T-SPOT.TB, QFT-G, and TST was 93.3%, 86.7%, and 58.3%, respectively. Conclusions: Although there was a discrepancy between TST and IGRA to diagnose tuberculosis, agreement between T-SPOT.TB and QFT-G was relatively high. Further prospective study to validate the clinical usefulness of each assay for immunologic evidence of tuberculosis infection in Korean children will be mandatory.