• Title/Summary/Keyword: PIV Technique

Search Result 318, Processing Time 0.018 seconds

Phase-Locked Three-Dimensional Structures in the Cylinder Wake Observed from Cinematic PIV Data (Cinematic PIV에 의한 실린더 후류의 위상평균된 3차원 구조)

  • Sung, Jae-Yong;Park, Kang-Kuk;Yoo, Jung-Yul
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.661-666
    • /
    • 2000
  • Near-wake flow field of a circular cylinder is studied by means of a cinematic PIV system with high sampling rate and large internal memory block. Experiments are conducted in a closed-cycle water tunnel system and a cross-correlation algorithm in conjunction with FFT (Fast Fourier Transform) analysis and an offset correlation technique is used for vector processing. With the help of very high sampling frequency compared to the shedding frequency, it is possible to obtain phase-averaged information of the three-dimensional wake, even though the shedding is not forced but natural. Phase-locked vortical structures observed simultaneously from the spanwise and cross-stream planes are displayed in the wake-transition regime where fine-scale secondary vortices have a spanwise wavelength or around one diameter. Spatial relations and temporal evolutions of the primary Karman vortex and the secondary vortex are also discussed schematically.

  • PDF

Highly Efficient PIV Measurement of Complex Flows Using Refractive Index Matching Technique

  • NISHINO Koichi;KAWAGUCHI Daisuke;KOSUGI Takashi;ISODA Haruo
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.57-63
    • /
    • 2004
  • various applications is presented. It is based on rapid-prototyping of transparent model for flow visualization and on the use of refractive index matching that enables efficient and clear visualization of the flow inside the model. The model is immersed in the index-matching fluid in a glass tank so that any displacement and rotation of the model in the tank have no influence on the optical setup for image acquisition to be made through a glass wall. This can facilitate greatly the camera calibration for stereo PIV and 3-D PTV. As the flow model is generated directly from 3-D surface data, no laborious preparation of the flow model is needed. This approach for seamless linking of model generation and PIV measurement is applicable to various flow measurements in automobile, ship building, fluid machinery, turbine, electrical appliances, heat exchanger, electronic cooling, bio-engineering and so on.

  • PDF

Measurements of a Ship's Propeller Wake with Stereoscopic-PIV and Stereoscopic-PTV (스테레오 PTV와 스테레오 PIV에 의한 선박프로펠러 후류측정)

  • Doh, Deog-Hee;Hwang, Tae-Gyu;Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.5 no.2
    • /
    • pp.26-32
    • /
    • 2007
  • Stereoscopic PTV and Stereoscopic-PIV measurements have been carried out for the studies of the wake of a ship's propeller. Stereoscopic photogrammetry based on a 3D-PTV principle was introduced using two high-definition cameras(1k x 1k, 30Hz). The arrangement of the two cameras was based on angular position. The pair-matching of the three-dimensional velocity vectors were based on Genetic Algorithm based 3D-PTV technique. The results obtained by both measurement systems have been compared at the advance ratio J=0.88(290 rpm, d=54 mm). Turbulent properties have also been compared each other at the same condition.

PIV Measurements of Ventilation Flow inside a Passenger Compartment (PIV를 이용한 실차 내부 환기유동의 정량적 속도장 측정)

  • Lee, Jin-Pyung;Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.3
    • /
    • pp.24-29
    • /
    • 2011
  • The improvement of climatic comfort is crucial not only for passenger comfort but also for driving safety. Therefore, a better understanding on the flow characteristics of ventilation flow inside the passenger compartment is essential. Most of the previous studies investigated the ventilation flow using Computational Fluid Dynamics (CFD) calculations or scale-down water-model experiments. In this study, the ventilation flow inside the passenger compartment of a real commercial automobile was investigated using a Particle Image Velocimetry (PIV) velocity field measurement technique. Under real operating conditions, the velocity fields were measured at several vertical planes for several ventilation modes. The experimental data obtained from this study can be used to understand the detailed flow characteristics in the passenger compartment of a real car and to validate numerical predictions.

An Experimental Study on Flow Structure inside a Display Cooler Using PIV Techniques (PIV기법을 이용한 전시용 냉장기의 내부 유동장 측정)

  • Park, Cheol-Woo;Baek, In-Je
    • Journal of the Korean Society of Visualization
    • /
    • v.5 no.2
    • /
    • pp.48-55
    • /
    • 2007
  • Flow structure inside a refrigerating compartment of a scale-down display cooler model was investigated experimentally by using PIV (particle image velocimetry) method, a reliable velocity field measurement technique, in the present study. In addition, we also carried out flow visualization regarding flow structure and particle movement inside a display cooler by using a tracer method. As a result, the mean velocity field measurement shows a large scale vortical flow structure inside a refrigerating compartment due to strong entrainment flow, going through a base plate open gaps.

Experimental Study on Internal Flow of a Mini Centrifugal Pump by PIV Measurement

  • Wu, Yulin;Yuan, Huijing;Shao, Jie;Liu, Shuhong
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.2
    • /
    • pp.121-126
    • /
    • 2009
  • The internal flow field in a centrifugal pump working at the several flow conditions has been measured by using the particle image velocimetry (PIV) technique with the laser induced fluorescence (LIF) particles and the refractive index matched (RIM) facilities. The impeller of the centrifugal pump has an outlet diameter in 100mm, and consists of six two-dimensional curvature backward swept blades of constant thickness. Measured results give reliable flow patterns in the pump. It is obvious that application of LIF particle and RIM are the key methods to obtain the right PIV measured results in pump internal flow.

PIV Measurement of Flow Inside an Automotive HVAC Module with Varying Temperature Baffle (온도조절 격판 변화에 따른 차량용 HVAC 내부 유동의 PIV속도장 측정 연구)

  • Ji, Ho-Seong;Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.6 no.1
    • /
    • pp.27-33
    • /
    • 2008
  • Air flow inside an automotive HVAC module has been investigated using a high-resolution PIV technique with varying the temperature operation mode. The PIV system consists of a 2-head Nd:YAG laser (125 mJ), a high-resolution CCD camera (2K$\times$2K), optics and a synchronizer. A real automotive HVAC module was used directly under real operating condition. Some casing parts of the HVAC module were replaced with transparent windows for capturing clear flow images with laser light sheet beam illumination. Time-averaged velocity fields were obtained for two different temperature control modes. Flow characteristics of the air-conditioned air flow inside the automotive HVAC system for the two temperature baffle conditions were evaluated.

Measurement of Honeycomb Turbulence in a Cavitation Tunnel Using Particle Image Velocimetry Method (PIV 기법을 이용한 캐비테이션 터널에서의 Honeycomb 난류 계측)

  • Ryu, Min-Cheol;Oh, Jung-Geun;Kim, Yoo-Chul;Koh, Won-Gyu;Lee, Youn-Mo;Suh, Jung-Chun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.45 no.1
    • /
    • pp.42-53
    • /
    • 2008
  • The two dimensional PIV (particle image velocimetry) measurement technique is applied to water flow in a narrow cavitation tunnel. The nearly homogeneous and isotropic turbulent flows are generated by the honeycomb installed in the tunnel and visualized with a PIV technique. The velocities in the measurement plane at the tunnel centerline 184cm downward from the honeycomb were measured and calculated by an image correlation technique. The turbulent properties are evaluated and each term in the turbulent kinetic energy equation is calculated for the conditions with different internal pressures. Lowering the internal pressure gives an effect on the turbulent flow due to growing bubbles which are resolved in the water. The turbulent kinetic energy in the measurement plane is decayed much slower than those of other research results carried out with wind tunnels. With decreasing the tunnel internal pressures the turbulent intensities are increased about 1.5 times and the anisotropic tendency is also increased.

PIV System for the Flow Pattern Anaysis of Artificial Organs ; Applied to the In Vitro Test of Artificial Heart Valves

  • Lee, Dong-Hyeok;Seh, Soo-Won;An, Hyuk;Min, Byoung-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.4
    • /
    • pp.489-497
    • /
    • 1994
  • The most serious problems related to the cardiovascular prothesis are thrombosis and hemolysis. It is known that the flow pattern of cardiovascular prostheses is highly correlated with thrombosis and hemolysis. Laser Doppler Anemometry (LDA) is a usual method to get flow pattern, which is difficult to operate and has narrow measure region. Particle Image Velocimetry (PIV) can solve these problems. Because the flow speed of valve is too high to catch particles by CCD camera, high-speed camera (Hyspeed : Holland-Photonics) was used. The estimated maximum flow speed was 5m/sec and maximum trackable length is 0.5 cm, so the shutter speed was determined as 1000 frames per sec. Several image processing techniques (blurring, segmentation, morphology, etc) were used for the preprocessing. Particle tracking algorithm and 2-D interpolation technique which were necessary in making gridrized velocity pronto, were applied to this PIV program. By using Single-Pulse Multi-Frame particle tracking algorithm, some problems of PIV can be solved. To eliminate particles which penetrate the sheeted plane and to determine the direction of particle paths are these solving methods. 1-D relaxation fomula is modified to interpolate 2-D field. Parachute artificial heart valve which was developed by Seoul National University and Bjork-Shiely valve was testified. For each valve, different flow pattern, velocity profile, wall shear stress and mean velocity were obtained.

  • PDF

Quantitative Measurements of Complex Flow Field Around a Hydrofoil Using Particle Image Velocimetry (PIV를 이용한 수중익 주위 복잡유동장의 정량적 계측)

  • B.S. Hyun;K.S. Choi;D.H. Doh
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.37 no.3
    • /
    • pp.37-44
    • /
    • 2000
  • An experimental study has been carried out at circulating water channel to investigate the viscous flow around breaking waves generated by a submerged hydrofoil(NACA0012). Detailed flow measurements were made at several critical points including an incipient wave-breaking point and a fully-developed wave breaker. Particle Image Velocimetry(PIV) was employed to visualize the flow field very close to the breaker as well as at the near- and far-wake of the breaker. Generation, development and decay of the wave breaker have been investigated. It is found that PIV technique could be well applied to the complex flow field, including the vortical structures near the free surface as well as the wake of the hydrofoil.

  • PDF