• 제목/요약/키워드: PIV System

검색결과 381건 처리시간 0.026초

PIV에 의한 NACA0012 익 주변의 유동특성 (Flow Characteristics around a NACA0012 Airfoil by PIV)

  • 최민선;조대환;이영호
    • 동력기계공학회지
    • /
    • 제3권1호
    • /
    • pp.29-37
    • /
    • 1999
  • The flow characteristics of a NACA0012 airfoil was investigated in rectangular water circulating channel. The flow patterns around an airfoil at various angles of attack between $0^{\circ}\;and\;30^{\circ}\;at\;Re=1.91{\times}104$ were visualized and measured with 2-D PIV system and laser sheet illumination. Flow behaviors such as velocity distribution, kinetic energy and flow separation etc. around an airfoil were obtained by means of 2-D PIV system. The behaviors show the difference of flow pattern clearly and separation phenomena become more active with increasing angle of attack.

  • PDF

Dynamic PIV를 이용한 난류 제트유동 해석 (Measurement of turbulent jet flow using dynamic PIV technique)

  • 이상준;장영길;김석
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2005년도 추계학술대회 논문집
    • /
    • pp.36-39
    • /
    • 2005
  • Information on temporal evolution of whole velocity fields is essential for physical understanding of a complicated turbulent flow and was obtainable using dynamic PIV because of advances of high-speed imaging technique, laser and electronics. A dynamic PIV systme consists of a high-speed CMOS camera having $1K\times1K$ pixels resolution at 1 KHz and a high-repetition Nd:Yag pulse laser. In order to validate its performance, the dynamic PIV system was applied to a turbulent jet whose Reynolds number is about 3000. The particle images of $1024\times512$ pixels were captured at a sampling rate of 4 KHz. The dynamic PIV system measured successfully the temporal evolution of instantaneous velocity fields of the turbulent jet, from which spectral analysis of turbulent structure was also feasible.

  • PDF

Development of higher performance algorithm for dynamic PIV

  • NISHIO Shigeru
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 Proceedings of 2004 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.25-32
    • /
    • 2004
  • The new algorithm for higher performance of dynamic PIV has been proposed. Present study considered mathematical basis of PIV analysis for multiple-time-step images and it enables us to analyze the high time-resolution PIV, which is obtained by dynamic PIV system. Conventional single pair image PIV analysis gives us the velocity field data in each time step but it sometimes contains unnecessary information of target flow. Present technique utilize multi-time step correlation information, and it is analyzed.

  • PDF

PIV기법을 이용한 차량용 공조 시스템 내부유동에 대한 실험적 연구 (An experimental analysis of the fluid flow in an automobile HVAC system using a PIV technique)

  • 지호성;김보람;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2007년도 추계학술대회
    • /
    • pp.92-96
    • /
    • 2007
  • Internal flow characteristics for an automobile HVAC have been investigated using a high-resolution PIV technique. The PIV system consists of a 2-head Nd:YAG laser(125 mJ), a high-resolution CCD camera($2K\;{\times}\;2K$), optics and a synchronizer. An automobile HVAC module was used directly. Only the casing was remodeled transparently for capturing flow image and laser sheet beam illumination. Time-averaged velocity field were measured in three temperature control mode. For three temperature control modes, the internal flow characteristics for an automobile HVAC system were evaluated from PIV results..

  • PDF

고해상도 CCD카메라를 이용한 Single-Frame PIV 속도장 측정기법 개발 (Development of Single-Frame PIV Velocity Field Measurement Technique Using a High Resolution CCD Camera)

  • 이상준;신대식
    • 대한기계학회논문집B
    • /
    • 제24권1호
    • /
    • pp.21-28
    • /
    • 2000
  • Although commercial PIV systems have been widely used for the non-intrusive velocity field measurement of fluid flows, they are still under development and have considerable room for improvement. In this study, a single-frame double-exposure PIV system using a high-resolution CCD camera was developed. A pulsed Nd:Yag laser and high-resolution CCD camera were synchronized by a home-made control circuit. In order to resolve the directional ambiguity problem encountered in the single-frame PIV technique, the second particle image was genuinely shifted in the CCD sensor array during the time interval dt. The velocity vector field was determined by calculating the displacement vector at each interrogation window using cross-correlation with 50% overlapping. In order to check the effect of spatial resolution of CCD camera on the accuracy of PIV velocity field measurement, the developed PIV system with three different resolution modes of the CCD camera (512 ${\times}$ 512, lK ${\times}$ IK, 2K ${\times}$ 2K) was applied to a turbulent flow which simulate the Zn plating process of a steel strip. The experimental model consists of a snout and a moving belt. Aluminum flakes about $1{\mu}m$ diameter were used as scattering particles for the liquid flow in the zinc pot and the gas flow above the zinc surface was seeded with atomized olive oil with an average diameter of 1-$3{\mu}m$. Velocity field measurements were carried out at the strip speed $V_s$=1.0 m/s. The 2K ${\times}$ 2K high-resolution PIV technique was significantly superior compared to the smaller pixel resolution PIV system. For the cases of 512 ${\times}$ 512 and 1K ${\times}$ 1K pixel resolution PIV system, it was difficult to get accurate flow structure of viscous flow near the wall and small vortex structure in the region of large velocity gradient.

파노라마-PIV를 이용한 실내기류 해석 (Analysis of Airflows in a Room with Panoramic PIV)

  • 황태규;도덕희
    • 설비공학논문집
    • /
    • 제17권12호
    • /
    • pp.1154-1160
    • /
    • 2005
  • A panoramic-PIV system has been constructed for the analysis of the airflows in a room. Smoke is used as seeding particles and are visualized by a pulsed laser (Nd-Yag, 120 mJ). Panoramic images have been obtained by an image composition process using the two images obtained by the two cameras $(1k\times1k)$ that are viewing the wide measurement areas. Velocity vector fields have been obtained by the grey-level cross-correlation PIV method. Three room models $(L{\times}W{\times}H[mm^3],\;500\times500\times250,\;350\times350\times175,\;250\times250\times125)$ have been tested. The experimental results have proven that the constructed panoramic-PIV system can be used as a useful tool for analyzing the airflow characteristics in the room models.

스테레오 PIV (Stereoscopic PIV)

  • 도덕희;이원제;조경래;편용범;김동혁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.394-399
    • /
    • 2001
  • A new stereoscopic PIV is introduced. The system works with CCD cameras, stereoscopic photogrammetry, and a 3D-PTV principle. Virtual images are produced for the construction of a benchmark testing tool of PIV techniques. The arrangement of the two cameras is based on angular position. The calibration of cameras and the pair-matching of the three-dimensional velocity vectors are based on 3D-PTV technique.

  • PDF

Angiographic PIV 기법을 이용한 혈액유동의 in-vitro 연구 (In vitro application of Angiographic PIV technique to blood flows)

  • 김국배;임남윤;정성용;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2007년도 추계학술대회
    • /
    • pp.105-108
    • /
    • 2007
  • To diagnose the vascular diseases from the viewpoint of hemodynamics, we need detailed quantitative hemodynamic information of related blood flows with a high spatial resolution of tens micrometer and a high temporal resolution in the order of millisecond. For investigating in-vivo hemodynamic phenomena of vascular circulatory diseases, a new diagnosing technique combining a medical radiography and PIV method was newly developed. This technique called 'Angiographic PIV system' consists of a medical X-ray tube, an X-ray CCD camera, a shutter module for generating double pulse-type X-ray, and a synchronizer. Through several preliminary tests, the feasibility of the Angiographic PIV technique was verified. For in-vivo applications to real blood flows, we developed tracer microcapsules, which were optimized to this system, made of a contrast material of iodine and a matrix material of PVA (polyvinylpyrrolidone). In near future, the Angiographic PIV technique will be used for understanding hemodynamic phenomena of vascular diseases and for their early detection.

  • PDF

PIV에 의한 가정용 온수펌프의 유동장 계측 (Measurement of Flow Field in a Domestic Hot-Water Pump by PIV)

  • 이현;임유청;김재현;이영호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.264-271
    • /
    • 1999
  • The present experimental study is aimed to investigate the flow characteristics of the high-speed flow field within hot-water pump by PIV(Particle Image Velocimetry). As multi-point simultaneous velocity acquisition, 2-D PIV system based upon the two-frame gray-level cross correlation method is adopted using PC frame-grabber and simple video system. Gated image intensifier CCD Camera to cope with illumination problem is arranged for accurate PIV measurement of high-speed complex flow. The velocity vector distribution, velocity profile, and kinetic energy are represented quantitatively at the full-scale region for the deeper understanding of the unsteady flow characteristics in a pump.

  • PDF

공기부양 물체의 유동-구조 연동운동 해석을 위한 능동형 스테레오-PIV 시스템 (Adaptive Stereoscopic-PIV System for the Analyses of the Flow-Structure-Interactions (FSI) of Air-Lifted Bodies)

  • 도덕희;황태규;조효제
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.420-425
    • /
    • 2006
  • Measurements results of flow-structure-interactions (FSI) of an air-lifted body are introduced. An adaptive stereoscopic-PIV system has been constructed for the measurements of the air-lifted body. The measurement system consists of two cameras and optical sensors. The flow characteristics around a lifted cylinder body(length=60mmm, diameter =10mm, polystyrene) in the swirling flow field in a vertical pipe (length=600mm, inner diameter=) are investigated by the use of the constructed adaptive stereoscopic-PIV system. The images of the two cameras were used for the analysis of the flow fields around the floated cylinder body. The images of the cylinder body captured by the two cameras were used for the analyses of its motions. Four optical sensors (LED) were used for the detection of the postures of the freely-lifted cylinder body. The FSI analyses have been carried out to find the physical conditions at which the floating body is stabilized with its upright postures.

  • PDF