• 제목/요약/키워드: PIV Measurement

검색결과 359건 처리시간 0.025초

PIV계측에 의한 디퓨져펌프 안내깃에서의 유동특성 (Flow Characteristics of Guide Vane of Diffuser Pump by PIV Measurement)

  • 김정환;최장운;김미영;이현;이영호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.391-396
    • /
    • 2000
  • The present experimental study is focused on the application of multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to guide vane region within a diffuser pump. Various different kinds of clearance were selected as experimental conditions. Optimized cross correlation identification to obtain velocity vectors was implemented with direct calculation of correlation coefficients. Fine optical setup important in PIV performance is arranged for the accurate PIV measurement of high-speed complex flow. Various flow patterns are represented quantitatively at the stator passages.

  • PDF

PIV를 이용한 터빈펌프의 동${\cdot}$정익 속도장 계측 (Measurement of the Velocity Field of Rotor-Stator in a Centrifugal Turbine Pump Using PIV)

  • 임유청;서민식;이영호
    • 한국유체기계학회 논문집
    • /
    • 제2권1호
    • /
    • pp.35-42
    • /
    • 1999
  • The present experimental study is focused on the application of multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to rotor-stater region within centrifugal turbine pump. Six different kinds of rpm(120, 500, 1000, 1500, 2000 and 2500) are selected as experimental condition. Optimized cross correlation identification to obtain velocity vectors is implemented with direct calculation of correlation coefficients. Fine optical setup concerned with PIV performance is arranged for the accurate PIV measurement of high-speed complex flow. The instantaneous and time-mean velocity distribution and velocity profile are represented quantitatively at the rotor and stator region.

  • PDF

Stereoscopic PIV 기법의 개발과 이를 이용한 축류 홴 후류의 유동해석 (Development of Stereoscopic PIV Measurement Technique and Its Application to Wake behind an Axial Fan)

  • 윤정환;이상준
    • 대한기계학회논문집B
    • /
    • 제26권2호
    • /
    • pp.362-373
    • /
    • 2002
  • A stereoscopic PIV (SPIV) measurement system based on the translation configuration was developed and applied to the flow behind a forward-swept axial-fan. Measurement of three orthogonal velocity components is essential for flow analysis of three-dimensional flows such as flow around a fan or propeller. In this study, the translation configuration was adopted to calculate the out-of-plane velocity component from 2-D PIV data obtained from two CCD cameras. The error caused by the out-of-plane motion was estimated by direct comparison of the 2-D PIV and 3-D SPIV results that measured from the particle images captured simultaneously. The comparison shows that the error ratio is relatively high in the region of higher out-of-plane motion near the axial fan blade. The turbulence intensity measured by the 2-D PIV method is bigger by about 5.8% in maximum compared with that of the 3-D SPIV method. The phase-averaged velocity field results show that the wake behind an axial fan has a periodic flow structure with respect to the blade phase and the characteristic flow structure is shifted downstream in the next phase.

미소입자영상유속계를 이용한 굴절률이 다른 두 유체 유동 측정 (Micro PIV Measurement of Two-Fluid Flow with Different Refraction Indices)

  • 김병재;유임정;성형진
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.107-114
    • /
    • 2003
  • The influence of property difference in refraction index on micro PIV measurement of two-fluid flow in a microchannel was analyzed. The difference of measurement planes in two fluids would bring misunderstanding of the physics. The objective-imaging system for two-fluid flow measurement was presented, and the condition for measurement of valid velocity profile across two-fluid interface was derived. A micro PIV experimental system was set up to measure two-fluid flow inside a Y-shape microchannel. Under the conditions, three cases of two-fluid flow of glycerol solutions at different concentration (${\phi}$), e.g., (${\phi}=0\;and\;{\phi}=0.2,\;{\phi}=0.1\;and\;{\phi}=0.5,\;{\phi}=0\;and\;{\phi}=0.6$, were measured. Close agreement of experimental and numerical results was found.

  • PDF

Miniature Stereo-PIV 시스템의 개발과 응용 (Development and Application of a Miniature Stereo-PIV System)

  • 김경천;;김상혁
    • 대한기계학회논문집B
    • /
    • 제27권11호
    • /
    • pp.1637-1644
    • /
    • 2003
  • Stereoscopic particle image velocimetry is a measurement technique to acquire three dimensional velocity field by two cameras. With a laser sheet illumination, the third velocity component can be deduced from out-of$.$plane velocity components using a stereoscopic matching method. Most industrial fluid flows are three dimensional turbulent flows, so it is necessary to use the stereoscopic PIV measurement method. However the existing stereoscopic PIV system seems hard to use since it is very expensive and complex. In this study we have developed a Miniature Stereo-PIV(MSPIV) system based on the concept of the Miniature PIV system which we have already developed. In this paper, we address the design and some primitive experimental results of the Miniature Stereo-PIV system. The Miniature Stereo-PIV system features relatively modest performances, but is considerably smaller, cheaper and easy to handle. The proposed Miniature Stereo-PIV system uses two one-chip-only CMOS cameras with digital output. Only two other chips are needed, one for a buffer memory and one for an interfacing logic that controls the system. Images are transferred to a personal computer (PC) via its standard parallel port. No extra hardware is required (in particular, no frame grabber board is needed).

PIV에 의한 인삼세척기 모델 내부의 유동계측 (Measurement of Flow Field in a Ginseng Cleaner Model Using PIV)

  • 송치성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권1호
    • /
    • pp.139-145
    • /
    • 2001
  • The objective of experimental study is to apply simultaneous measurement by PIV(Particle Image Velocimetry) to high_speed flow characteristics within ginseng cleaner model. Three different kinds of flow rate(15. 20, 27l/min) are selected as experimental condition. Optimized cross correlation identification to obtain velocity distribution, time-mean velocity distribution, velocity, profile, kinetic energy and turbulence intensity are represented quantitatively for the deeped understanding of the flow characteristics in a ginseng cleaner model.

  • PDF

인삼세척기 내부유동장의 PIV계측 및 유동특성 (PIV Measurement and Flow Characteristics of Internal Flow Field within Ginseng Washing Machine)

  • 나은수;송치성
    • 연구논문집
    • /
    • 통권30호
    • /
    • pp.59-65
    • /
    • 2000
  • The objective of experimental study is to apply simultaneous measurement by PIV(Particle Image Velocimetry)to high_speed flow characteristics within Ginseng washing machine. Three different kinds of flow rate(15,20,27 $\ell$/min)are selected as experimental conditions. Optimized cross correlation identification to obtain velocity vectors is implemented by direct calculation of correlation coefficients. Instantaneous velocity distribution, time-mean velocity distribution and velocity profiles are represented quantitatively at the full-scale region for the deeper understanding of the flow characteristics in Ginseng washing machine.

  • PDF

아데노이드 비대증에 의한 비정상 비강 내 유동의 PIV해석 (PIV Measurement on Airflows in the Abnormal Nasal Cavity with the Adenoid Vegetation)

  • 김성균;손영락
    • 대한기계학회논문집B
    • /
    • 제27권4호
    • /
    • pp.518-523
    • /
    • 2003
  • Airflow in the nasal cavity of Korean adults is investigated experimentally by PIV measurement. Quantitative data for normal and abnormal nasal cavities with adenoid vegetation are obtained. The CBC PIV algorithm with window offset is used for PIV flow analysis. Average and RMS distributions are obtained for inspirational and expirational nasal airflows. Comparisons between western and Korean nasal airflows are appreciated. Due to the difference in geometry of the frontal part of nasal cavity, the flow near nares shows the difference. For the joint research on nasal deceases, PIV measurements of nasal airflow for nasal cavities with 50% and 70% adenoid vegetation are conducted for the first time. Comparisons in nasal airflows for both normal and abnormal cases are also appreciated.

초음파 조영제를 애용한 Echo PIV 기법의 개발 (Development of Echo PIV Using Ultrasound Contrast Agent)

  • 김형범
    • 대한기계학회논문집B
    • /
    • 제28권12호
    • /
    • pp.1528-1534
    • /
    • 2004
  • The combination of ultrasound echo images with digital particle image velocimetry (DPIV) methods has resulted in a two-dimensional, two-component velocity field measurement technique appropriate for opaque flow conditions including blood flow in clinical applications. Advanced PIV processing algorithms including an iterative scheme and window offsetting were used to increase spatial resolution. The optimum concentration of the ultrasound contrast agent used for seeding was explored. Velocity validation tests in fully developed laminar pipe flow result of echo PIV showed good agreement with both optical PIV measurements and the known analytic solution based on a volume flow measurement.

PIV 기법과 Digital Mask 기법을 적용한 버블유동 측정 (The Measurement of Bubble Driven Flow Using PIV and Digital Mask Technique)

  • 김상문;김현동;김경천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2700-2703
    • /
    • 2008
  • An experiment on bubble-driven flow was performed in order to understand fundamental knowledge of flow structure around a rising bubble in a stagnant fluid. The measurement technique consists of a combination of the three most often used PIV techniques in multiphase flows: PIV with fluorescent tracer particles, the digital phase separation with a masking technique and a shadowgraphy. The key point of the measurement is that the background intensity of a PIV recording can be shifted to a higher level than a bubble region using a shadowgraphy in order to distinguish from fluorescent particles and a bubble as well. Flow fields were measured without an inaccurate analysis around a fluid-bubble interface by using only one camera simply.

  • PDF