• Title/Summary/Keyword: PIN diode

Search Result 165, Processing Time 0.017 seconds

Cooling Performance Study of a Impinging Water Jet System with Heat Sink for High Power LEDs (분사냉각모듈 내에 부착된 히트싱크에 따른 고출력 LED의 냉각성능에 관한 연구)

  • Ku, G.M.;Kim, K.;Park, S.H.;Choi, S.D.;Heo, J.W.
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.6
    • /
    • pp.152-158
    • /
    • 2013
  • The purpose of this study is to investigate cooling performance of high power LEDs from 100 to 200 W class by using a jet impingement cooling module. The numerical analysis of forced convection cooling inside cooling module is carried out using a multi-purpose CFD software, FLUENT 6.3. In the experiments, the LED cooling system consists of jet impingement module, heat exchanger, water reservoir, and pump. In the present study, the cooling performance of jet impingement cooling module is investigated to determine the effect of the heat sink types on the impinging surface, the space and length of fins. Numerical and experimental studies show the reasonable agreement of LED metal PCB temperature between those results and give the optimized design parameters such as the space of fin and the length of fin. Also, the pin fin type of heat sink is found to be more efficient than the plate type heat sink in jet impingement cooling.

A Study on the Efficiency Improvement of Dye Sensitized Solar Cell (염료감응형 태양전지의 효율향상에 관한 연구)

  • Kim, Hee-Je;Seok, Young-Kuk;Kim, Ming-Chul
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2009.06a
    • /
    • pp.467-470
    • /
    • 2009
  • A novel 8 V DC power source with an external series-parallel connection of 50 Dye-Sensitized Solar Cells(DSSCs) has been proposed. One DSC has the optimized length to width ratio of $5.2{\times}2.6$ cm and an active area 8 $cm^2$($4.62{\times}1.73$ cm) which attained a conversion efficiency of 4.2%. From the electrochemical impedance spectroscopic analysis, it was found that the resistance elements related to the Pt electrode and electrolyte interface behave like that of diode and the series resistance corresponds to the sum of the other resistance elements. In addition, the TEMoo mode pulsed Nd:YAG laser beam is used to improve the incident photon to current efficiency(IPCE) of DSSC. From this result, this novel 8V-0.38A DC power source shows stable performance with an energy conversion efficiency of about 4.5% under 1 sun illumination(AM 1.5, Pin of 100 $mW/cm^2$).

  • PDF

The effects of light colour on female rabbit reproductive performance and the expression of key genes in follicular development

  • Xiaoqing, Pan;Xinglong, Wang;Le, Shao;Jie, Yang;Feng, Qin;Jian, Li;Xia, Zhang;Pin, Zhai
    • Journal of Animal Science and Technology
    • /
    • v.64 no.3
    • /
    • pp.432-442
    • /
    • 2022
  • The purpose of this study was to analyse the effects of light colour on rabbit reproductive performance and the expression of key follicular development genes. Rabbits (n = 1,068, 5 months old, 3.6-4.4 kg live body weight) were divided randomly into four groups, housed individually in wire mesh cages and exposed to red, green, blue, and white light-emitting diode (LED) light (control). The lighting schedule was 16 L : 8 D-15 d / 150 lx / 6:00 am-22:00 pm (3 d preartificial insemination to 12 d postartificial insemination). Red light and white light affected the conception rate and kindling rate and increased the total litter size at birth (p < 0.05). The effects of red light on litter size at weaning, litter weight at weaning, and individual weight at weaning increased compared with the green and blue groups. The effects of red light on live litter size at birth were increased compared with those in the blue group (p < 0.05). Compared to white light, green and blue light reduced the number of secondary follicles (p < 0.05). Compared to red light, green and blue light reduced the number of tertiary follicles (p < 0.05). Compared with white light, red LED light resulted in greater ovarian follicle stimulating hormone receptor and luteinizing hormone receptor mRNA expression (p < 0.05). Compared with green and blue LED light, red LED light resulted in greater B-cell lymphom-2 mRNA expression (p < 0.05). Compared with green LED light, red LED light inhibited FOXO1 mRNA expression in rabbit ovaries (p < 0.05). Red light can affect the reproductive performance of female rabbits and the expression of key genes for follicular development.

Comparative evaluation of photobiomodulation therapy at 660 and 810 nm wavelengths on the soft tissue local anesthesia reversal in pediatric dentistry: an in-vivo study

  • Ankita Annu;Sujatha Paranna;Anil T. Patil;Sandhyarani B.;Adhithi Prakash;Renuka Rajesh Bhurke
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.23 no.4
    • /
    • pp.229-236
    • /
    • 2023
  • Background: Local anesthesia has been reliably used to control pain during dental procedures and is important in pediatric dentistry. However, children occasionally complain of prolonged numbness after dental treatment, leading to several problems. Studies conducted to reverse the effect of local anesthesia using phentolamine mesylate and photobiomodulation therapy (PBM) are encouraging but limited. PBM is a type of light therapy that utilizes visible and near-infrared non-ionizing electromagnetic spectral light sources. Hence, this study used this modality to compare the reversal of local anesthesia at two different wavelengths. This study compared the effect of PBM at 660 and 810 nm wavelengths on the reversal of soft tissue local anesthesia using a diode LASER in pediatric dentistry. Method: Informed consent and assent were obtained, and the participants were then divided randomly into three groups of 20 children each: control group-without LASER irradiation, LASER irradiation at 660 nm, and LASER irradiation at 810 nm. Sixty children aged 4-8 years with deciduous mandibular molars indicated for pulp therapy were administered an inferior alveolar nerve block. After 45 min of injection, a duration that was similar to the approximate duration of treatment, they were exposed to 660- and 810-nm LASER irradiation according to their groups until reversal of local anesthesia was achieved. The control group did not undergo LASER irradiation. The reversal of the soft tissue local anesthetic effect was evaluated using palpation and pin prick tests every 15 min, and the LASER irradiation cycle continued until reversal of the soft tissue local anesthesia was achieved. Results: A significant reduction of 55.5 min (27.6%) in the mean soft tissue local anesthesia reversal time was observed after the application of 810 nm wavelength PBM and 69 min (34.7%) after 660 nm wavelength LASER irradiation. Conclusion: PBM with a 660 nm wavelength was more effective in reducing the mean soft tissue local anesthesia reversal duration, and thus can be used as a reversal agent for soft tissue local anesthesia in pediatric dentistry.

HVL Measurement of the Miniature X-Ray Tube Using Diode Detector (다이오드 검출기를 이용한 초소형 X선관(Miniature X-ray Tube)의 반가층 측정)

  • Kim, Ju-Hye;An, So-Hyeon;Oh, Yoon-Jin;Ji, Yoon-Seo;Huh, Jang-Yong;Kang, Chang-Mu;Suh, Hyunsuk;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.279-284
    • /
    • 2012
  • The X ray has been widely used in both diagnosis and treatment. Recently, a miniature X ray tube has been developed for radiotherapy. The miniature X ray tube is directly inserted into the body irradiated, so that X rays can be guided to a target at various incident angles according to collimator geometry and, thus, minimize patient dose. If such features of the miniature X ray tube can be applied to development of X ray imaging as well as radiation treatment, it is expected to open a new chapter in the field of diagnostic X ray. However, the miniature X ray tube requires an added filter and a collimator for diagnostic purpose because it was designed for radiotherapy. Therefore, a collimator and an added filter were manufactured for the miniature X ray tube, and mounted on. In this study, we evaluated beam characteristics of the miniature X ray tube for diagnostic X ray system and accuracy of measuring the HVL. We used the Si PIN Photodiode type Piranha detector (Piranha, RTI, Sweden) and estimated the HVL of the miniature X ray tube with added filter and without added filter. Through an another measurement using Al filter, we evaluated the accuracy of the HVL obtained from a direct measurement using the automatic HVL calculation function provided by the Piranha detector. As a result, the HVL of the miniature X ray tube was increased around 1.9 times with the added filter mounted on. So we demonstrated that the HVL was suitable for diagnostic X ray system. In the case that the added filter was not mounted on, the HVL obtained from use of the automatic HVL calculation function provided by Piranha detector was 50% higher than the HVL estimated using Al filter. Therefore, the HVL automatic measurement from the Piranha detector cannot be used for the HVL calculation. However, when the added filter was mounted on, the HVL automatic measurement value using the Piranha detector was approximately 15% lower than the estimated value using Al filter. It implies that the HVL automatic measurement can be used to estimate the HVL of the miniature X ray tube with the added filter mounted on without a more complicated measurement method using Al filter. It is expected that the automatic HVL measurement provided by the Piranha detector enables to make kV-X ray characterization easier.