• 제목/요약/키워드: PID(Proportional Integral Derivative)

검색결과 177건 처리시간 0.027초

A Robust PID Control Method with Neural Network

  • Kang, Seong-Ho;Lee, Yong-Gu;Eom, Ki-Hwan
    • Journal of information and communication convergence engineering
    • /
    • 제2권1호
    • /
    • pp.46-51
    • /
    • 2004
  • The problem of reducing the effect of an unknown disturbance on a dynamical system is one of the most fundamental issues in control design. We propose a robust PID (Proportional Integral Derivative) control method with neural network for improving the performance due to the rejection of an unknown disturbance. The proposed system consists of a model of the plant, a conventional PID controller and a multi-layer neural network, and is composed of two loop; the first loop enables the system to achieve stability of system, the second loop rejects an unknown disturbance. Simulation and experiment results show that the proposed method improves considerably on the performance of the conventional PID control method and the typical IMC method using neural network.

Determination of PID Coefficients for the Ascending and Descending System Using Proportional Valve of a Rice Transplanter

  • Siddique, Md. Abu Ayub;Kim, Wan-Soo;Baek, Seung-Yun;Kim, Yeon-Soo;Choi, Chang-Hyun;Kim, Yong-Joo;Park, Jin-Kam
    • Journal of Biosystems Engineering
    • /
    • 제43권4호
    • /
    • pp.331-341
    • /
    • 2018
  • Purpose: This study was conducted to develop a linear Proportional-Integral-Derivative (PID) control algorithm for the ascending and descending system of a rice transplanter and to analyze its response characteristics. Methods: A hydraulic model using a single-acting actuator, proportional valve and a PID control algorithm were developed for the ascending and descending system. The PID coefficients are tuned using the Ziegler-Nichols (Z-N) method and the characteristics of unit step response are analyzed to select the PID coefficients at various pump speeds. Results: Results showed that the performance of the PID controller was superior in any condition. It was found that the highest settling time and maximum overshoot were less than 0.210 s and 5%, respectively at all pump speed. It was determined that the steady state errors were 0% in all the cases. The lowest overshoot and settling time were calculated to be nearly 2.56% and 0.205 s, respectively at the pump rated speed (2650 rpm). Conclusions: The results indicated that the developed PID control algorithm would be feasible for the ascending and descending system of a rice transplanter. Finally, it would be helpful to plant the seedlings uniformly and improve the performance of the rice transplanter.

Applying TID-PSS to Enhance Dynamic Stability of Multi-Machine Power Systems

  • Mohammadi, Ramin Shir;Mehdizadeh, Ali;Kalantari, Navid Taghizadegan
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권5호
    • /
    • pp.287-297
    • /
    • 2017
  • Novel power system stabilizers (PSSs) have been proposed to effectively dampen low frequency oscillations (LFOs) in multi-machine power systems and have attracted increasing research interest in recent years. Due to this attention, recently, fractional order controllers (FOCs) have found new applications in power system stability issues. Here, a tilt-integral-derivative power system stabilizer (TID-PSS) is proposed to enhance the dynamic stability of a multi-machine power system by providing additional damping to the LFOs. The TID is an extended version of the classical proportional-integral-derivative (PID) applying fractional calculus. The design of the proposed three-parameter tunable TID-PSS is systematized as a nonlinear time domain optimization problem in which the tunable parameters are adjusted concurrently using a modified group search optimization (MGSO) algorithm. An integral of the time multiplied squared error (ITSE) performance index is considered as the objective function. The proposed stabilizer is simulated in the MATLAB/SIMULINK environment using the FOMCON toolbox and the dynamic performance is evaluated on a 3-machine 6-bus power system. The TID-PSS is compared with both classical PID-PSS (PID-PSS) and conventional PSS (CPSS) using eigenvalue analysis and time domain simulations. Sensitivity analyses are performed to assess the robustness of the proposed controller against large changes in system loading conditions and parameters. The results indicate that the proposed TID-PSS provides the better dynamic performance and robustness compared with the PID-PSS and CPSS.

도어제어장치(DCU)의 PID Control DB 생성장치 (Door Control Unit Create Provision for PID Control DB)

  • 김진헌;권영현;성창용;권민정;이한수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.3065-3072
    • /
    • 2011
  • PID Control Data Base creation device of DCU is safety operation technology of train door. For keeping the normal condition of door, measured value of regular condition and unusual(trouble detected) condition should be recorded by encoding. The door should be measured itself as this value is compared with standard vale. If it's condition of the door and for reaching the datum point and ot does self-diagnosis. This aim for Technical Realization is that carry out safety train operation by using the Estimation Data Base and protect before door-trouble.

  • PDF

Paper Machine Industrial Analysis on Moisture Control Using BF-PSO Algorithm and Real Time Implementation Setup through Embedded Controller

  • Senthil Kumar, M.;Mahadevan, K.
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.490-498
    • /
    • 2016
  • Proportional Integral Derivative (PID) controller tuning is an area of interest for researchers in many areas of science and engineering. This paper presents a new algorithm for PID controller tuning based on a combination of bacteria foraging and particle swarm optimization. BFO algorithm has recently emerged as a very powerful technique for real parameter optimization. To overcome delay in an optimization, combine the features of BFOA and PSO for tuning the PID controller. This new algorithm is proposed to combine both the algorithms to get better optimization values. The real time prototype model of paper machine is designed and controlled by using PIC microcontroller embedded with the programming in C language.

Analytical Method to Design Multiloop Control Systems via DCLR

  • Kim, Chang-Geun;Chun, Dae-Woong;Lee, Jie-Tae;Lee, Ki-Hong;Lee, Mon-Yong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.50.5-50
    • /
    • 2001
  • Although many advanced control strategies and concepts have been proposed recently, the most popular controller in the process industries is the PID controller because of its simplicity, easy implementation, and robustness. A multiloop PID controller design method using the general IMC tuning rule is presented in this paper. The IMC-PID controller is formed by combining the integral term designed by considering interactions between the individual loops with the proportional and derivative terms designed in circumstance neglecting the interactions. The multiloop PID controller designed by the proposed method can approximate the ideal multiloop controller throughout overall frequency range, and ...

  • PDF

A realization Fuzzy PI and Fuzzy PD Controller using a compensation Fuzzy Algorithms

  • Kim, Seung-Cheol;Choo, Yeon-Gyu;Kang, Shin-Chul;Lim, Young-Do;Park, Boo-Kwi;Lee, Ihn-Yong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.101.4-101
    • /
    • 2002
  • I. Introduction ▶The PID(Proportional-Integral-Derivative) controller is widely used in the industry it can be implemented easily for a typical second order plant. ▶The parameters of PID controller should be adapted complicatedly if a plant is various or the load is present. ▶For solving the problem, many control techniques have been developed. ▶A major method is a hybrid Fuzzy-PID controller. But, in case of using this method, we can not obtain characteristic of rapidly response and not achieved compensation on disturbance. ▶Therefore, we will use compensator fuzzy controller a front Hybrid type fuzzy-PID controller...

  • PDF

Analysis and Implementation of ANFIS-based Rotor Position Controller for BLDC Motors

  • Navaneethakkannan, C.;Sudha, M.
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.564-571
    • /
    • 2016
  • This study proposes an adaptive neuro-fuzzy inference system (ANFIS)-based rotor position controller for brushless direct current (BLDC) motors to improve the control performance of the drive under transient and steady-state conditions. The dynamic response of a BLDC motor to the proposed ANFIS controller is considered as standard reference input. The effectiveness of the proposed controller is compared with that of the proportional integral derivative (PID) controller and fuzzy PID controller. The proposed controller solves the problem of nonlinearities and uncertainties caused by the reference input changes of BLDC motors and guarantees a fast and accurate dynamic response with an outstanding steady-state performance. Furthermore, the ANFIS controller provides low torque ripples and high starting torque. The detailed study includes a MATLAB-based simulation and an experimental prototype to illustrate the feasibility of the proposed topology.

BLDCM 의 속도 제어를 위한 퍼지 P+ID 제어기 설계 (Design of a Fuzzy P+ID controller for brushless DC motor speed control)

  • 김영식;이창구;김성중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2161-2163
    • /
    • 2002
  • The PID type controller has been widely used in industrial application doc to its simply control structure, ease of design and inexpensive cost. However control performance of the PID type controller suffers greatly from high uncertainty and nonlinearity of the system, large disturbances and so on. This paper presents a hybrid fuzzy logic proportional plus conventional integral derivative controller (Fuzzy P+ID). In comparison with a conventional PID controller, only one additional parameter has to be adjusted to tune the Fuzzy P+ID controller. In this case, the stability of a system remains unchanged after the PID controller is replaced by the Fuzzy P+ID controller without modifying the original controller parameters. Finally, the proposed hybrid Fuazy P+ID controller is applied to BLDC motor drive. Simulation results demonstrated that the control performance of the proposed controlled is better than that of the conventional controller.

  • PDF

수처리공정의 모델링과 지능제어의 적용 (Modeling and Intelligent control for Wastewater treatment process)

  • 천성표;김봉철;김성신
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2333-2335
    • /
    • 2000
  • The main motivation of this research is to develop an intelligent control strategy for Activated Sludge Process(ASP). ASP is a complex and nonlinear dynamic system because of the characteristic of a wastewater, the change of an influent flow rate, weather conditions, and etc. The mathematical model of ASP also includes uncertainties which are ignored or not considered by process engineer or controller designer. The ASP is generally controlled by a PID controller that consists of fixed proportional, integral, and derivative gain values. The PID gains can be adjusted by the expert in the ASP. The ASP model based on Matlab$^{(R)}$5.3/Simulink$^{(R)}$3.0 is developed in this paper. Various control methods are applied to the ASP model and the control results are disscussed. Three control methods are designed and tested: conventional PID controller, fuzzy logic control approach to modify setpoints, and fuzzy-PID control method.

  • PDF