• Title/Summary/Keyword: PI plane

Search Result 115, Processing Time 0.022 seconds

Software development for the visualization of brain fiber tract by using 24-bit color coding in diffusion tensor image

  • Oh, Jung-Su;Song, In-Chan;Ik hwan Cho;Kim, Jong-Hyo;Chang, Kee-Hyun;Park, Kwang-Suk
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.133-133
    • /
    • 2002
  • Purpose: The purpose of paper is to implement software to visualize brain fiber tract using a 24-bit color coding scheme and to test its feasibility. Materials and Methods: MR imaging was performed on GE 1.5 T Signa scanner. For diffusion tensor image, we used a single shot spin-echo EPI sequence with 7 non-colinear pulsed-field gradient directions: (x, y, z):(1,1,0),(-1,1,0),(1,0,1),(-1,0,1),(0,1,1),(0,1,-1) and without diffusion gradient. B-factor was 500 sec/$\textrm{mm}^2$. Acquisition parameters are as follows: TUTE=10000ms/99ms, FOV=240mm, matrix=128${\times}$128, slice thickness/gap=6mm/0mm, total slice number=30. Subjects consisted of 10 normal young volunteers (age:21∼26 yrs, 5 men, 5 women). All DTI images were smoothed with Gaussian kernel with the FWHM of 2 pixels. Color coding schemes for visualization of directional information was as follows. HSV(Hue, Saturation, Value) color system is appropriate for assigning RGB(Red, Green, and Blue) value for every different directions because of its volumetric directional expression. Each of HSV are assigned due to (r,$\theta$,${\Phi}$) in spherical coordinate. HSV calculated by this way can be transformed into RGB color system by general HSV to RGB conversion formula. Symmetry schemes: It is natural to code the antipodal direction to be same color(antipodal symmetry). So even with no symmetry scheme, the antipodal symmetry must be included. With no symmetry scheme, we can assign every different colors for every different orientation.(H =${\Phi}$, S=2$\theta$/$\pi$, V=λw, where λw is anisotropy). But that may assign very discontinuous color even between adjacent yokels. On the other hand, Full symmetry or absolute value scheme includes symmetry for 180$^{\circ}$ rotation about xy-plane of color coordinate (rotational symmetry) and for both hemisphere (mirror symmetry). In absolute value scheme, each of RGB value can be expressed as follows. R=λw|Vx|, G=λw|Vy|, B=λw|Vz|, where (Vx, Vy, Vz) is eigenvector corresponding to the largest eigenvalue of diffusion tensor. With applying full symmetry or absolute value scheme, we can get more continuous color coding at the expense of coding same color for symmetric direction. For better visualization of fiber tract directions, Gamma and brightness correction had done. All of these implementations were done on the IDL 5.4 platform.

  • PDF

Flow Resistance and Modeling Rule of Fishing Nets -2. Flow Resistance of Bag Nets- (그물어구의 유수저항과 모형수칙 -2. 자루형 그물의 유수저항-)

  • KIM Dae-An
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.2
    • /
    • pp.194-201
    • /
    • 1995
  • In order to make clear the resistance of bag nets, the resistance R of bag nets with wall area S designed in pyramid shape was measured in a circulating water tank with control of flow velocity v and the coefficient k in $R=kSv^2$ was investigated. The coefficient k showed no change In the nets designed in regular pyramid shape when their mouths were attached alternately to the circular and square frames, because their shape in water became a circular cone in the circular frame and equal to the cone with the exception of the vicinity of frame in the square one. On the other hand, a net designed in right pyramid shape and then attached to a rectangular frame showed an elliptic cone with the exception of the vicinity of frame in water, but produced no significant difference in value of k in comparison with that making a circular cone in water. In the nets making a circular cone in water, k was higher in nets with larger d/l, ratio of diameter d to length I of bars, and decreased as the ratio S/S_m$ of S to the area $S_m$ of net mouth was increased or as the attack angle 9 of net to the water flow was decreased. But the value of ks15m was almost constant in the region of S/S_m=1-4$ or $\theta=15-90^{\circ}$ and in creased linearly in S/S_m>4 or in $\theta<15^{\circ}$ However, these variation of k could be summarized by the equation obtained in the previous paper. That is, the coefficient $k(kg\;\cdot\;sec^2/m^4)$ of bag nets was expressed as $$k=160R_e\;^{-01}(\frac{S_n}{S_m})^{1.2}\;(\frac{S_m}{S})^{1.6}$$ for the condition of $R_e<100$ and $$k=100(\frac{S_n}{S_m})^{1.2}\;(\frac{S_m}{S})^{1.6}$$ for $R_e\geq100$, where $S_n$ is their total area projected to the plane perpendicular to the water flow and $R_e$ the Reynolds' number on which the representative size was taken by the value of $\lambda$ defined as $$\lambda={\frac{\pi d^2}{21\;sin\;2\varphi}$$ where If is the angle between two adjacent bars, d the diameter of bars, and 21 the mesh size. Conclusively, it is clarified that the coefficient k obtained in the previous paper agrees with the experimental results for bag nets.

  • PDF

A Study on Comparison of Strength Parameters of Hydrostatic Pressure-Dependent Yield Criteria (정수압에 의존하는 항복기준의 강도정수 비교연구)

  • Lee, Seung-Hyun;Han, Jin-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.529-535
    • /
    • 2016
  • In this theoretical study, the strength parameters of the Drucker-Prager yield criterion and Mohr-Coulomb yield criterion were set to equal values, in order to analyze the correlation among the parameters. The Drucker-Prager strength parameters ${\alpha}$ and k were represented by the Mohr-Coulomb strength parameters c and ${\phi}$. Specifically it can be seen that k is function of c, ${\phi}$ and ${\alpha}$ is function of ${\phi}$ alone. Drucker-Prager strength parameter ${\alpha}$ increases as the internal friction angle of soil increases. ${\alpha}_{av}$ which is the average of ${\alpha}_c$ and ${\alpha}_i$ was proportional to internal friction angle in which ${\alpha}_c$ and ${\alpha}_i$ are ${\alpha}$ values corresponding to the circles of the Drucker-Prager yield cirteria circumscribes and inscribes the Mohr-Coulomb yield criterion respectively. The values of the ${\alpha}_{av}$ was 0.07 and 0.29 which correspond to the internal friction angle of $10^{\circ}$ and $45^{\circ}$ respectively. In addition, value of ${\alpha}_c/{\alpha}_i$ was proportional to internal friction angle of soil and the values of ${\alpha}_c/{\alpha}_i$ 1.12 and 1.62 which corresponds to internal friction angle of $10^{\circ}$ and $45^{\circ}$ respectively.The influence of the Mohr-Coulomb strength parameters on the Drucker-Prager strength parameter k was investigated and it was found that k was mainly influenced by the cohesion of the soil, except in the case of the minimum assumed value of c of 10kPa. The deviator stresses, $S_{c0}$ and $S_{t0}$, which correspond to the cases of the Mohr-Coulomb yield criterion under uniaxial compression and uniaxial tension, respectively, and $S_{0(ave)}$, which is the average value of $S_{c0}$ and $S_{t0}$, decrease as the internal friction angle increases. Furthermore, the hexagon, which represents the Mohr-Coulomb yield locus, becomes more irregular, and the deviations of $S_{c0}$ and $S_{t0}$ from $S_{0(ave)}$ also increase, as the internal friction angle increases.

Flow Resistance and Modeling Rule of Fishing Nets 4. Flow Resistance of Trawl Nets (그물어구의 유수저항과 모형수칙 4. 트롤그물의 유수저항)

  • KIM Dae-An
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.5
    • /
    • pp.691-699
    • /
    • 1997
  • In order to find out the properties in flow resistance of trawlR=1.5R=1.5\;S\;v^{1.8}\;S\;v^{1.8} nets and the exact expression for the resistance R (kg) under the water flow of velocity v(m/sec), the experimental data on R obtained by other, investigators were pigeonholed into the form of $R=kSv^2$, where $k(kg{\cdot}sec^2/m^4)$ was the resistance coefficient and $S(m^2)$ the wall area of nets, and then k was analyzed by the resistance formular obtained in the previous paper. The analyzation produced the coefficient k expressed as $$k=4.5(\frac{S_n}{S_m})^{1.2}v^{-0.2}$$ in case of bottom trawl nets and as $$k=5.1\lambda^{-0.1}(\frac{S_n}{S_m})^{1.2}v^{-0.2}$$ in midwater trawl nets, where $S_m(m^2)$ was the cross-sectional area of net mouths, $S_n(m^2)$ the area of nets projected to the plane perpendicular to the water flow and $\lambda$ the representitive size of nettings given by ${\pi}d^2/2/sin2\varphi$ (d : twine diameter, 2l: mesh size, $2\varphi$ : angle between two adjacent bars). The value of $S_n/S_m$ could be calculated from the cone-shaped bag nets equal in S with the trawl nets. In the ordinary trawl nets generalized in the method of design, however, the flow resistance R (kg) could be expressed as $$R=1.5\;S\;v^{1.8}$$ in bottom trawl nets and $$R=0.7\;S\;v^{1.8}$$ in midwater trawl nets.

  • PDF

Patients with brain metastases the usefulness of contrast-enhanced FLAIR images after delay (뇌전이 환자의 조영 증강 후 지연 FLAIR 영상의 유용성)

  • Byun, Jae-Hu;Park, Myung-Hwan;Lee, Jin-Wan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.1
    • /
    • pp.13-19
    • /
    • 2014
  • Purpose: FLAIR image is beneficial for the diagnosis of various bran diseases including ischemic CVS, brain tumors and infections. However the border between the legion of brain metastasis and surrounding edema may not be clear. Therefore, this study aims to investigate the practical benefits of delayed imaging by comparing the image from a patient with brain metastasis before a contrast enhancement and the image 10 minutes after a contrast enhancement. Materials and methods: Of the 92 people who underwent MRI brain metastases in suspected patients 13 people in three patients there is no video to target the 37 people confirmed cases, and motion artifacts brain metastases in our hospital June-December 2013, 18 people measurement position except for the three incorrect patient (male: 11 people, female: 7 people, average age: 60 years) in the target, test equipment, 3.0T MR System (ACHIEVA Release, Philips, I was 8ChannelSENSE Head Coil use Best, and the Netherlands). TR 11000 ms, TE 125 ms, TI2800 ms, Slice Thickness 5 mm, gap 5 mm, is a Slice number 21, the parameters of the 3D FFE, T2 FLAIR variable that was used to test, TR 8.1 ms, TE 3.7 ms, Slice number 240 I set to. The experiment was conducted by acquiring the FLAIR prior to contrast enhancement (heretofore referred to as Pre FLAIR), and acquiring the 3D FFE CE five minutes after the contrast enhancement, and recomposing the images in an axial plane of S/T 3mm, G 0mm (heretofore referred to as MPR TRA CE). Using the FLAIR 10 minutes after the contrast enhancement (heretofore referred to as Post FLAIR) and Pi-View, a retrospective study was conducted. Using MRIcro on the image of a patient confirmed for his diagnosis, the images before and after the contrast media, as well as the CNR and SNR of the MPR TRA CE images of the lesion and the site absent of lesion were compared and analyzed using a one-way analysis of variance. Results: CNR for Pre FLAIR and Post FLAIR were 34.35 and 60.13, respectively, with MPR TRA CE at 23.77 showing no significant difference (p<0.050). Post-experiment analysis shows a difference between Pre FLAIR and Post FLAIR in terms of CNR (p<0.050), but no difference in CNR between Post FLAIR and MPR TRA CE (p>0.050), indicating that the contrast media had an effect only on Pre FLAIR and Post FLAIR. The SNR for the normal site Pre FLAIR was 106.43, and for the lesion site 140.79. Post FLAIR for the normal site was 107.79, and for the lesion site 167.91. MPR TRA CE for the normal site was 140.23 and for the lesion site 183.19, showing significant difference (p<0.050), and post-experiment analysis shows that there was a difference in SNR only on the lesion sites for Pre FLAIR and Post FLAIR (p<0.050). There was no difference in SNR between the normal site and lesion site for Post FLAIR and MPR TRA CE, indicating no effect from the contrast media (p>0.050). Conclusions: This experiment shows that Post FLAIR has a higher contrast than Pre FLAIR, and a higher SNR for lesions, It was not not statistically significant and MPR TRA CE but CNR came out high. Inspection of post-contrast which is used in a high magnetic field is frequently used images of 3D T1 but, since the signal of the contrast medium and the blood flow is included, this method can be diagnostic accuracy is reduced, it is believed that when used in combination with Post FLAIR, and that can provide video information added to the diagnosis of brain metastases.

  • PDF