• Title/Summary/Keyword: PHR

Search Result 423, Processing Time 0.021 seconds

A Study on Physical Properties of EPDM/Polyhedral Oligomeric Silsesquioxane (POSS) Composites (EPDM/POSS(Polyhedral oligomeric silsesquioxane) 복합재료의 물성 연구)

  • Park, Hyun-Ho
    • Applied Chemistry for Engineering
    • /
    • v.32 no.4
    • /
    • pp.472-477
    • /
    • 2021
  • The crosslinking behavior of polyhedral oligomeric silsesquioxane (POSS) containing eight acrylate groups in a cage form in ethylene-propylene-diene rubber (EPDM) peroxide crosslinking, the effect on mechanical properties, and the thermal stability were investigated. An EPDM/POSS composite material was prepared by mixing 0 to 12 parts per hundreds of rubber (phr) of POSS per 100 phr of rubber by content and adding a peroxide crosslinking agent. As a result of crosslinking properties, it was found that the acrylate group of POSS was activated by peroxide and improved the peroxide crosslinking efficiency. Although the dispersion stability of POSS in EPDM/POSS composites was poor, the fracture strength, elongation and thermal stability were improved.

A Study on Dielectric Properties of Flame-Retardant Silicone Rubber Due to Silica Amount Change (실리카 양 변화에 의한 난연성 실리콘 고무의 유전특성에 관한 연구)

  • Lee, Sung Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.5
    • /
    • pp.364-370
    • /
    • 2021
  • In this study, the dielectric properties of flame retardant silicone rubber mixed with the amount of silica 50~65 phr were measured at frequencies ranging from 1 to 2.7 MHz and temperature ranges from 30℃ to 160℃. The permittivity decreased with higher frequencies and higher temperatures, and tanδ are thought to have decreased due to the increased heat oxidation of the methyl group bound to Si, which increased the hardness of silicone rubber. FT-IR analysis of specimen mixed with SiO2 of 50~65 phr showed oscillations of OH groups bound to SiO2 between wavenumber 3,600 and 3,300. As a result of analyzing surface components by Energy Dispersive X-ray (EDX) on all specimens mixed with SiO2 of 50 to 65 phr, all specimens contained Si, and the analysis by field emission scanning electron (FE-SEM) confirmed that about 1~5 ㎛ particles were distributed regularly on the surface of the specimens.

An Experimental Study for Electro-active Polymer Electrode and Actuator (전기활성 고분자 전극 및 구동기에 관한 실험적 연구)

  • Lee, Jun-Man;Ryu, Sang-Ryeoul;Lee, Dong-Joo;Lin, Zheng-Jie
    • Composites Research
    • /
    • v.26 no.5
    • /
    • pp.289-294
    • /
    • 2013
  • A thinner is used to improve the multi-walled carbon nano-tube (CNT) and carbon black (CB) dispersion in a polymer matrix and to make a soft electrode. The electrical and mechanical properties of the soft electrodes are investigated as functions of CNT, CB and thinner content. The optimal mixing condition for the electrode is thinner 80, CNT 3.5, CB 18 (phr) on the basis of matrix (KE-12). The specific resistance of that is 73 (${\Omega}{\cdot}cm$), and tensile strength, tensile modulus, and elongation of that is 0.45 MPa, 0.21 MPa, and 184%, respectively. Also, a simple structure of the actuator with an optimized electrode and elastomer is fabricated and its characteristic is evaluated. At the operating voltage 25 kV, the displacement of an elastomer KE-12 is 2.24 mm, and that of an elastomer KE-12 with thinner 50 (phr) is 4.05 mm. It shows a higher displacement compared to that of 3M 4910 which has similar modulus. The actuator made with elastomer and electrode of the same material (KE-12) may have advantages for fatigue life and application.

Design and Implementation of the Chronic Disease Management Platform based on Personal Health Records (개인건강기록 기반 만성질환 관리 플랫폼의 설계 및 구현)

  • Song, Je-Min;Lee, Yong-Jun;Nam, Kwang-Woo
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.17 no.1
    • /
    • pp.47-62
    • /
    • 2012
  • To propagate clinical disease management service, there should be built a ecosystem where service developers, service providers, device suppliers closely cooperate for u-Health platform. However, most u-Health platform is difficult to build an effective ecosystem due to the lack of secure and effective PHR(Personal Health Record) management, the lack of personalized and intelligent service, difficulties of N-screen service. To solve these problems we suggest the CDMP(Chronic Disease Management Platform) architecture. The CDMP is a software platform that provides the core functions to develop the chronic disease management services and performs a hub function for the link and integration rbetween various services and systems. CDMP is SOA based platform that enables a provision of reusability, expansibility and it provides open API where everybody can share information, contents and services easily. CDMP supports the multi platform system foN-screen service and the self management functions via SNS. In this paper, we design and implement the CDMP including PHR service based on hybrid data model for privacy preservation. Experiment results prove the effectiveness of hybrid model-based PHR service.

Effect of Styrene and Maleic Anhydride Content on Properties of PP/Pulp Composites and Reactive Extrusion of Random PP (랜덤 PP의 반응압출 및 PP/Pulp 복합체 특성에 대한 스티렌과 무수말레인산 함량의 영향)

  • Lee, Jong Won;Kim, Ji Hyun;Kim, Youn Cheol
    • Applied Chemistry for Engineering
    • /
    • v.25 no.3
    • /
    • pp.318-323
    • /
    • 2014
  • In order to analyze the effect of maleic anhydride (MAH) content and styrene monomer (SM)/MAH mole ratio on reactive extrusion of maleic anhydride grafted random polypropylenes (MAH-g-rPP), MAH-g-rPPs were prepared by using a twin screw extruder. MAH contents were 0.5, 1.0, 3.0, and 5.0 phr and SM/initiator mole ratio was 0.0, 1.0, and 2.0. Dicumyl peroxide (DCP) was used as an initiator. The graft degree of MAH was confirmed by the existence of carbonyl group (C = O) stretching peak at $1700cm^{-1}$ from FT-IR spectrum. The degree of graft reaction increased up to 3.0 phr MAH and showed the optimum value at 1.0 SM/MAH mole ratio from the area ratio of C = O and C-H stretching peak. Thermal and crystallization properties of MAH-g-rPP and PP/MAH-g-rPP/pulp composites were investigated by DSC, TGA, XRD, and POM. There was a decrease in non-isothermal crystallization temperature of PP/MAH-g-PP/pulp composites. Based on tensile properties and SEM pictures for the fractured surface of PP/MAH-g-PP/pulp composites, MAH content of 1.0 wt% and SM/MAH mole ratio of 1.0 were the optimum formulation as the compatibilizer. The rheological properties of the composites were measured by dynamic Rheometer to compare the processability of the composites with and without compatibilizer. The power law index showed slightly low value at the composites with compatibilizer.

A Study on Surface Properties of Mechanical Interfacial Behavior of DGEBA/PMR-15 Blends (DGEBA/PMR-15 블렌드계의 표면특성 변화가 기계적 계면특성에 미지는 영향)

  • Park, Soo-Jin;Lee, Hwa-Young;Han, Mijeong;Hong, Sung-Kwon
    • Journal of Adhesion and Interface
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 2003
  • In this work, the effect of PMR-15 content on the variation of surface free energy of the DGEBA/PMR-15 blend system was investigated in terms of contact angles and mechanical interfacial tests. Based on FT-IR result of the blend system. C=O (1,772, $1,778cm^{-1}$) and C-N ($1,372cm^{-1}$) peaks appeared with imidization of PMR-15 and -OH ($3,500cm^{-1}$) peak showed broadly at 10 phr of PMR-15 by ring-opening of epoxy. Contact angle measurements were performed by using deionized water and diiodomethane as testing liquids. As a result, the surface free energy of the blends gave a maximum value at 10 phr of PMR-15, due to the significant increasing of specific component. The mechanical interfacial properties measured from the critical stress intensity factor ($K_{IC}$) and the critical strain energy release rate ($G_{IC}$) showed a similar behavior with the results of surface energetics. This behavior was probably attributed to The improving of the interfacial adhesion between intermolecules, resulting from increasing the hydrogen bondings of the blends.

  • PDF

Study on Development a Personal Health Record Application of Atopic Dermatitis in Korean Medicine (아토피피부염 개인건강기록 앱 개발에 관한 연구)

  • Seo, Jin-Soon;Kim, Young-Eun;Lee, Seung-Ho;Kim, An-Na;Nam, Bo-Ryeong;Jang, Hyun-Chul
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.32 no.1
    • /
    • pp.32-41
    • /
    • 2019
  • Objective : The purpose of this study is to develop a personal health record(PHR) application of atopic dermatitis in Korean Medicine(KM). Methods : We have identified the items necessary to provide an PHR application that helps to record and manage the symptoms of an atopic dermatitis in KM. We also derived the symptom collection process and method and applied it to the application. Results : In this study, the types of symptoms collected for atopic dermatitis were derived. Symptoms include daily check, stool/urine/sleep, daily emotion, meal management, symptom photographs, SCORAD, quality of life, progress check, original symptom, pediatric health check, weakness check, and subjective symptoms. The recording cycle can be divided into the first, daily, weekly, specific day, and subjective. We developed the PHR application of atopic dermatitis in KM by deriving the type of symptoms and symptom recording process. The app organized menus into dashboards, checklists, daily checks, and health records. Conclusions : We developed a PHR application for atopic dermatitis by deriving symptom collection items of atopic dermatitis and developing symptom collection process and collection technique. The app does not make an accurate diagnosis of atopic dermatitis symptoms, but it helps facilitate symptom collection and helps to identify or predict a person's health condition. It can also be used for medical treatment through sharing symptoms with Korean medicine. Patients are able to communicate in both directions on a daily, weekly, self-aware basis, at the request of a doctor, to record their symptoms and use them for medical purposes. If the doctor asks for a progress check to refer to the next examination, it can be written through the system. This manages atopic dermatitis in daily life and can be used in the clinical field.

Physical Properties of Elastic Epoxies for High Voltage

  • Lee, Kwan-Woo;Park, Yong-Sung;Park, Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.2
    • /
    • pp.51-54
    • /
    • 2004
  • In this paper, the thermal and mechanical properties of elastic epoxy for the application of high voltage products were investigated. Glass transition temperature (Tg) of elastic epoxies cannot be found from room temperature to 20$0^{\circ}C$ by DSC (Differential Scanning Calorimetry). Weight reduction occurred at 285$^{\circ}C$ and 451$^{\circ}C$ according to a thermogravimeter. The first temperature was affected by addictives and the second by epoxies characteristic. Maximum tensile strain showed 28.3kgf/$\textrm{cm}^2$/$\textrm{cm}^2$ at 20% of mechanical stress in addictives 35 (phr). The SEM (Scanning electron microscope) micrograph of the fracture surface observed void and tearing of elastic epoxy at addictives 35 (phr). On the other side, the SEM micrograph of the rigid epoxy showed a broken trace.