• Title/Summary/Keyword: PHES

Search Result 9, Processing Time 0.099 seconds

Experimental Investigation of an Cross-Flow Air-Cooled Plate Heat Exchanger with Single-Wave and Double-Wave Plates (단일굴곡 및 이중굴곡 판 형상을 갖는 직교류 공랭식 판형열교환기의 전열특성에 대한 실험적 연구)

  • Kim, Min-Sung;Paik, Young-Jin;Lee, Jae-Hoon;Park, Seong-Ryong;Ra, Ho-Sang;Jeong, Jae-Hoon;Lim, Hyug
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.6
    • /
    • pp.347-354
    • /
    • 2009
  • Experimental study on a cross-flow air-cooled plate heat exchanger (PHE) was performed. Two types of PHEs were manufactured either with single-wave plates or with double-wave plates in parallel. Cooling air flows through the PHEs in a crosswise direction against internal hot water. The heat exchanger aims to substitute open-loop cooling towers with closed-loop water circulation, which guarantees cleanliness and compactness. In this study, prototype single-wave and double-wave PHEs were designed and tested in a laboratory scale experiments. From the tests, the double-wave PHE shows approximately 50% enhanced heat transfer performance compared to the single-wave PHE. However, the double-wave PHE costs 30% additional pressure drop. For the commercialization, a wide channel design for air flow would be essential for performance and reliability.

Electronic Properties and Conformation of$\pi$-Conjugated Molecules with Phenyl and Heterocyclic Group

  • Eunho Oh;Kim, Cheol-Ju
    • Journal of Photoscience
    • /
    • v.7 no.2
    • /
    • pp.67-71
    • /
    • 2000
  • A quantum-chemical investigation on the conformations and electronic properties of trans(diphenyl-diheterocyclic) ethenes(t-PHEs) as building block for fully $\pi$-conjuated polymer are performed in order to display the effects of heterocyclic ring substitution. Structures for the molecules, t-PHEs were fully optimized by using semiempirical AM1, PM3 methods, and ab initio HF methods, with 6-31G basic set. The potential energy curves with respect to the change of single are obtained by using ab initio HF/6-31G basic set. The curves are not similar shapes in the molecules with respect to heterocyclic rings. It is shown that the steric repulsion interactions between phenyl ring and heterocyclic ring are subjected to different type with the respect to each heterocyclic ring. Electronic properties of the molecules were molecules were obtained by applying the optimized structures and selected geometries to the extended Huckel method. To investigate the change of HOMO-LUMO gap with respedt to the torsion angle, we select the optimized structures. By using the results, the dependency of conjugation for the energy gaps is analyzed. For t-PHE the energy gap increase up to 0.52 eV compared with its planar structure. In the cases of t-PHE and t-PHE, the energy gap increase by 1.29 and 1.15 eV, respectively, compared with its planar structure.

  • PDF

A Study on Thermal Performance Comparison between Large and Small Sized Plate Heat Exchanger (판형 열교환기 크기에 따른 전열성능 비교에 관한 연구)

  • Park, Jae-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.528-534
    • /
    • 2020
  • The early development and use of plate heat exchangers (PHE) were in response to stringent statutory requirements from dairy products in the late 19th century, but PHEs were not exploited commercially until the 1920s. Since then, although the basic concept of PHEs has changed little, its design and construction have progressed significantly to accommodate higher temperatures and pressures, as well as large heat exchanging capacities. The development of current chevron-type corrugated heat plates has been ongoing since the oil shock in the 1970s to improve energy efficiency. The development trend of PHEs is consistent with the development of larger heat plates with better thermal efficiency, lower pressure drop, and good flow distribution. In this study, the thermal performance of small heat plates (PHE-S) and large heat plates (PHE-L) with the same plate depth and corrugation pitch were analyzed experimentally for each channel (H, M, and L type) to suggest development directions of heat plates. The test results showed that for the convectional heat transfer coefficient, the PHE-S was on average, 16.5% higher in the H type, 25% higher in the M type, and 40% higher in the L type than PHE-L. In the case of the pressure drop, the PHE-S was 19% higher in the H type, 46% higher in the M type, and 61% higher in the L type than PHE-L. These results were attributed to the differences in fluid distribution areas between the PHE-S and PHE-L, among other potential causes.

A Study on Thermal Performance of Plate Cooler for Cooling Medium Speed Engine Lubricant Oil (선박용 중속엔진 오일냉각용 판형쿨러의 전열성능에 관한 연구)

  • Park, Jae-Hong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.83-90
    • /
    • 2020
  • Plate heat exchangers(PHE) have been commercialized since the 1920s. Since then, although the basic concept of PHEs has changed little, its design and construction have progressed significantly to accommodate higher temperatures, higher pressures, and large heat exchanging capacities. The development trend of PHEs is consistent with heat plate developments with better thermal efficiency, lower pressure drop, and good flow distribution. The purpose of this paper is to introduce the main development processes of a plate cooler for medium-speed engine lubricant oil cooling in vessels which is in line with the development trend of PHEs and to provide its thermal performance data that were found out during experimental tests. The plate cooler in this study cannot measure the wall temperatures directly due to its structural characteristics, so the heat transfer coefficients were calculated using the modified Wilson Plot method. The water-to-water tests were first conducted experimentally to figure out the characteristics of heat transfer coefficients and pressure drops on the water side and then the water-to-oil tests followed to obtain the heat transfer coefficients on the oil side. The test results showed that heat transfer coefficients and pressure drops on both water and oil side increased with flow rates, and it was also found that all the development targets of the plate cooler in this study were achieved successfully.

Intelligent Energy Harvesting Power Management and Advanced Energy Storage System (지능형 에너지 저장시스템과 ESS 개발을 위한 소재 및 공정 기술)

  • Heo, Kwan-Jun;Kim, Sung-Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.7
    • /
    • pp.417-427
    • /
    • 2014
  • Renewable energy sources such as solar, wind and hydro provides utilizing renewable power and reduce the using fossil fuels. On the other hand, it is too critical to apply power system due to the intermittent nature of renewable energy sources, the continuous fluctuations of the power load, and the storage with high energy density. Energy storage system, including pumped-hydroelectric energy storage, compressed-air energy storage, superconducting magnetic energy storage, and electrochemical devices like batteries, supercapacitors and others have shown that solve some of the challenges. In this paper, we review the current state of applications of energy storage systems, and atomic layer deposition technology, graphene materials on the energy storage systems and processes.

Development of an Cross Flow Air-Cooled Plate Heat Exchanger (직교류 공랭식 판형열교환기의 성능평가)

  • Kim, Min-Sung;Lee, Jae-Hoon;Park, Seong-Ryong;Ra, Ho-Sang;Jeong, Jae-Hoon;Lim, Hyug
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.235-240
    • /
    • 2007
  • Performance of an air-cooled plate heat exchanger (PHE) was evaluated in this study. The PHE was manufactured in two types of single-wave and double-wave plates in parallel assembly. The heat exchanger aims to substitute open-loop cooling towers with closed-loop water circulation, which guarantees cleanliness and compactness. In this study, prototype single-wave and double-wave PHEs were designed and tested in a laboratory scale experiments. From the tests, the double-wave PHE shows approximately 50% enhanced heat transfer performance compared to the single-wave PHE. However, the double-wave PHE costs 30% additional pressure drop. For the commercialization, a wide channel design for air flow would be essential for performance and reliability.

  • PDF

Investigation of the effect of Erythrosine B on a β-amyloid (1-40) peptide using molecular modeling method

  • Lee, Juho;Kwon, Inchan;Cho, Art E.;Jang, Seung Soon
    • Proceeding of EDISON Challenge
    • /
    • 2015.03a
    • /
    • pp.14-23
    • /
    • 2015
  • Alzheimer's disease is one of the most common types of degenerative dementia. As a considerable cause of Alzheimer's disease, neurotoxic plaques composed of 39 to 42 residue-long amyloid beta($A{\beta}$) fibrils have been found in the patient's brain in large quantity. A previous study found that erythrosine B (ER), a red color food dye approved by FDA, inhibits the formation of amyloid beta fibril structures. Here, in an attempt to elucidate the inhibition mechanism, we performed molecular dynamics simulations to demonstrate the conformational change of $A{\beta}40$ induced by 2 ERs in atomistic detail. During the simulation, the ERs bound to the surfaces of both N-terminus and C-terminus regions of $A{\beta}40$ rapidly. The observed stacking of the ERs and the aromatic side chains near the N-terminus region suggests a possible inhibition mechanism in which disturbing the inter-chain stacking of PHEs destabilizes beta-sheet enriched in amyloid beta fibrils. The bound ERs block water molecules and thereby help stabilizing alpha helical structure at the main chain of C-terminus and interrupt the formation of the salt-bridge ASP23-LYS28 at the same time. Our findings can help better understanding of the current and upcoming treatment studies for Alzheimer's disease by suggesting inhibition mechanism of ER on the conformational transition of $A{\beta}40$ at the molecular level.

  • PDF

Korean Drift Gillnet Fishery For Flying Squid , Ommastrephes bartrami ( Lesueur ) , and the Variation of Oceanographic Conditions in the North Western Pacific Ocean (한국의 빨간 오징어 유자망 어업과 북서태평양의 해황 변동)

  • 임기봉
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.22 no.3
    • /
    • pp.8-16
    • /
    • 1986
  • The fishing conditions of flying squid, ommastrePhes barsram(Lesueur), in the North Pacific Ocean was studied based on the horizontal water temperature data, satellite data from NOAA and statistical data of flying squid fisheries which were collected from 1980 to 1984. The obtained results were as follows; 1. Since 1979, the Korean drift giIlnet fishery for flying squid was launched in North Pacific. Number of operating vessel and catch of flying squid increased gradually every year. The number of vessels were 111 and their annual catches were 42, 977 M/T in 1984. Therefore, Korean drift giIlnet fishery for this species has played an important role in the products of Korean high-sea fisheries. 2. In the beginning of the fisheries, fishing grounds was formed in the west of long. 1800E. In 1982, in consequence of the center which extended eastward, the fishing ground was formed long. 166$^{\circ}$W in the central North Pacific Ocean. Since 1983, the fishing grounds were formed as far as long. 161$^{\circ}$W. The range of general fishing season in the central North Pacific was from June to August. After september, fishing ground was shifted to the west, in the Northwestern Pacific. 3. The Predominant fishing season for the flying squid was August through January of the coming year. Optimum water temperature for flying sguid at surface layer in the Pacific Ocean ranged from 11 $^{\circ}$e to 17$^{\circ}$e in winter, 13$^{\circ}$e to 17$^{\circ}$e in spring, 12. 8$^{\circ}$C to 19.7$^{\circ}$e in summer and 1O.6$^{\circ}$e -18.7$^{\circ}$e in fall. 4. In summer, the Oceanographic condition in the North Pacific Ocean showed that the water temperature at surface layer was lower in 1980, 1983 and higher in 1981, 1982 and 1984 as compared with mean annual water temperature. 5. The characteristics df oceanographic conditions in the fluation, disformation, mixing and other factors of the Kuroshio and Oyashio currents, which have considerably influenced upon the water masses of the areas. 6. The data and information on surface thermal Structure interpreted from Infrared Satellite Imaginary from NOAA-7 and NOAA-8 are very available in estimating water temperature on the areas and investigating the major fishing grounds. 7. According to the fisheries statics of Japanese drift gilInet, the annual catches of flying squid considerably decreased from 225, 942 M/T in 1983 to 133, 217 M/T in 1984. 8. The fishing grounds in the central North Pacific in several fishing seasons were formed as follows: In June, the initial fishing season, the fishing grounds were formed in the vicinity of lat. 35 - 40oN, the central North Pacific east of 179$^{\circ}$E. In July, the fishing ground were formed in the wide arEa of the central North Pacific north of 400N and long. 174$^{\circ}$E-145$^{\circ}$W In Auguest, concentrative fishing operation carried out in :he central North Pacific north of 43$^{\circ}$N and East of 165$^{\circ}$W. On the other hand, in September, main fishing grounds were disappeared and moved to the west.

  • PDF

Diurnal Variations in Milk and Blood Urea Nitrogen and Whole Blood Ammonia Nitrogen in Dairy Cows

  • Hwang, Sen-Yuan;Lee, Mei-Ju;Peh, Huo-Cheng
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.12
    • /
    • pp.1683-1689
    • /
    • 2001
  • The levels of urea nitrogen both in blood (BUN) and milk (MUN), and milk protein (MP) reflect protein and energy intake in dairy herd feeding. Blood and milk constituents may be changes rhythmically and influence by different sampling time within a day and after feeding. Trials were conducted using five dietary treatments in both lactating and dry cows to study the effects of sampling time on concentrations of BUN, MUN and whole blood ammonia nitrogen (BAN) in practical dairy cow feeding in Taiwan. The conventional feed ingredients and forages including corn silage, alfalfa hay, timothy or pangola hay and corn grain were used as major source of the diet to follow practical dairy cow feeding. Five different diets were varying in amounts (low=L; standard=S; high=H) of crude protein (P) and energy (E) according to the NRC (1989). The energy to protein ratios in kcal/kg for the PSES, PLES, PHES, PSEH and PSEL were 10.82, 12.54, 9.41, 12.53 and 9.13 in lactating cows, and 11.38, 13.33, 9.78, 13.28 and 9.74 in dry cows, respectively. Results showed that after feeding at 9:30, BUN reached peak at 13:30 and was significantly higher than those to that sampled at 14:30 to 18:30 (p<0.05) in dry cows. Therefore the best blood sampling time for urea nitrogen assay in dry cows is 4 hours after morning feeding. In lactating cows, BUN of 13:30 was significantly higher than those of 8:30 to 11:30 (p<0.05), but there were no significant difference between the BUN values of other sampling time. Hence the suitable blood sampling time for BUN value in lactating cows was located on 3 to 8 hours after morning feeding, but the best time was 4 hours after morning feeding. MUN content is significantly higher in the afternoon collected bulk milk than the fore-strip morning milk (p<0.05), therefore the best sampling time for MUN is from afternoon collected bulk milk. Diurnal BAN changed without traceable rhythmic pattern and was negatively correlated to the BUN (r = -0.78). It is suggested that BAN may not be a good indicator for monitoring dairy cow feeding.