• 제목/요약/키워드: PHC piles

검색결과 107건 처리시간 0.025초

Recycling of In-site waste soil material to fill a hollow between PHC pile and Earthen wall

  • Jang, Myung-Houn;Choi, Hee-Bok
    • 한국건축시공학회지
    • /
    • 제12권5호
    • /
    • pp.510-517
    • /
    • 2012
  • This study evaluated the recycling potential of in-site waste soil as pile back filling material (PBFM). We performed experiments to check workability, segregation resistance, bond strength, direct shear stress test, and dynamic load test using in-site waste soil in coastal areas. We found that PBFM showed better performance than general cement paste in terms of workability, segregation resistance, and bond strength. On the other hand, the structural performance of PBFM was slightly lower than that of general cement paste due to the skin friction force of pile by Pile Driving Analyzer and direct shear stress. However, because this type of performance degradation in terms of structure can be improved through the use of piles with larger diameter or by changing the type of pile, considering the economics and environment, we considered that recycling of PBFM has sufficient value.

말뚝 강성을 고려한 지반의 지진하중 저감 효과에 관한 해석 연구 (Analysis on the Seismic Load Reduction Effect of a Ground by Considering Pile Strength)

  • 김상연;박종배;박용부;김동수;이세현
    • 토지주택연구
    • /
    • 제3권4호
    • /
    • pp.451-456
    • /
    • 2012
  • 최근에 건설되는 고층 건물들은 지하 3층 이상의 깊은 지하층을 갖는 경우가 일반적이며, 이 경우에 국내 지반의 특성상 기반암 깊이가 얕아 지하층하부가 암반에 장착되거나 지중에 위치하는 경우가 많다. 현행 우리나라 내진설계기준의 지진하중은 자유장인 지표면에서의 응답을 바탕으로 하고 있어 말뚝이 매설된 기초 하부 지반에서의 지진하중과 상이하므로 비교 및 검증이 요구된다. 이를 위하여 본 연구에서는 2차원 동적(2D Dynamic) 수치해석 기법을 이용하여 말뚝기초가 기반암에 근입될 때 말뚝 강성효과에 의한 기초저면에서의 지진하중 감소를 확인하였으며 경제적인 내진설계를 수행할 수 있는 가능성을 확인해 보았다. 현행 내진 설계기준에 따른 자유장 지표면 가속도를 설계 지진 하중산정 과정에서 말뚝 강성을 고려한 지진 하중 저감효과를 평가하기 위해 PLAXIS 2D 프로그램을 사용하여 말뚝 개수 4개, 8개, 12개인 세가지 말뚝 배치 경우에 대하여 지중 및 기초상부의 최대 지진 가속도와 동일 깊이의 자유장 최대 지진 가속도를 수치해석을 통하여 비교한 결과, 지반내 매설된 말뚝 기초에 의해 20~25%가량의 지진하중 저감효과가 있는 것을 확인하였다. 그러나 말뚝의 개수 및 콘크리트 기초의 크기는 지진응답 특성에 큰 영향을 미치지 않는 것으로 평가되었다.

3차원 수치해석을 통한 궤도지지말뚝의 동적거동 평가 (Evaluation of Dynamic Behavior for Pile-Supported Slab Track System by 3D Numerical Analysis)

  • 유민택;백민철;이일화;이진선
    • 한국지진공학회논문집
    • /
    • 제21권5호
    • /
    • pp.255-264
    • /
    • 2017
  • Dynamic numerical simulation of pile-supported slab track system embedded in a soft soil and embankment was performed. 3D model was formulated in a time domain to consider the non-linearity of soil by utilizing FLAC 3D, which is a finite difference method program. Soil non-linearity was simulated by adopting the hysteric damping model and liner elements, which could consider soil-pile interface. The long period seismic loads, Hachinohe type strong motions, were applied for estimating seismic respose of the system, Parametric study was carried out by changing subsoil layer profile, embankment height and seismic loading conditions. The most of horizontal permanent displacement was initiated by slope failure. Increase of the embedded height and thickness of the soft soil layer leads increase of member forces of PHC piles; bending moment, and axial force. Finally, basic guidelines for designing pile-supported slab track system under seismic loading are recommended based on the analysis results.

Calculation method for settlement of micropile installed in rock layers through field tests

  • Hwang, TaeHyun;Cho, JungMin;Lee, YeongSaeng
    • Geomechanics and Engineering
    • /
    • 제31권2호
    • /
    • pp.197-208
    • /
    • 2022
  • Micropiles consisting of steel bars and grouts are commonly used in underpinning methods to reinforce supports or to suppress the subsidence of existing structures. Recently, applications in the field of geotechnical engineering have expanded. Despite the increasing use of micropiles are used, the PHC or steel pile formula is still applied for the settlement amount of micropiles. Compared with field test results, the amount of micropile subsidence obtained from the existing method may result in a very large error in the displacement of the micropile. Therefore, it is difficult to utilize micropiles effectively. Hence, to solve this problem, this study evaluated the behaviors and support characteristics of micropiles through field compression and tensile tests, and proposed a method for predicting the amounts of their subsidence. To confirm the appropriateness of the proposed method, field test results and the results obtained using the proposed method were compared. It was found that the settlement amounts of the micropiles as predicted through the existing method were significantly overestimated (error ≈ 50-80%) relative to the field test results, whereas the settlement errors of the piles predicted through the proposed method decreased (error ≈6-32%). Thus, it is possible to reduce the previously overestimated amount of settlement, and the modified method of this study allows more efficient design than the conventional method.

주변 지반의 열전도도를 고려한 PHC 에너지파일의 열 거동 및 파일 간 열 간섭 현상에 대한 수치해석 연구 (Thermal Behavior of Energy Pile Considering Ground Thermal Conductivity and Thermal Interference Between Piles)

  • 고규현;윤석;박도원;이승래
    • 대한토목학회논문집
    • /
    • 제33권6호
    • /
    • pp.2381-2391
    • /
    • 2013
  • 일반적으로 에너지파일의 열적 성능에 영향을 주는 중요한 인자로 지반의 열 물성, 열 교환기 형태, 운용방법, 파일 간 열 간섭 등이 고려될 수 있다. 본 연구에서는 지반의 실제 조건을 반영한 수치모델을 통해 이들 인자들이 미치는 영향을 살펴보았다. 지반의 포화 정도에 따라서 파일의 열 교환율은 최대 3배까지 차이를 보였으며, 열 저항은 최대 8.7%의 차이가 발생하였다. 또한 열 교환기 유형이 파일의 열 성능에 영향을 주며, 3U-Type이 W나 U-Type에 비해 상대적으로 높은 열 효율을 보였다. 운용방법에 있어서, 부분가동 시(8시간 가동, 16시간 휴지) 연속가동에 비해서 약 20%의 열효율을 보전할 수 있으며, 장기적인 열 축적현상을 방지하는데 유리하다. 지반의 조건에 따라 군 말뚝에 의한 열 간섭 정도가 달라지는데, 지반이 포화상태에서 건조 상태로 갈수록 군 말뚝에 의한 열 간섭효과는 감소한다. 일반적인 지반조건에서 열 교환 감소율 1%미만을 유지하는 적정 이격 거리는 U-Type에서 최대 3.2D, W-Type에서 최대 3.6D, 3U-Type에서 최대 3.7D로 산정되었다.

에너지 파일의 현장 열응답 시험에 관한 연구 (Evaluation of Thermal Response Test of Energy Pile)

  • 윤석;이승래;김민준;고규현
    • 한국지반공학회논문집
    • /
    • 제30권4호
    • /
    • pp.93-99
    • /
    • 2014
  • 최근 들어 경제적인 지열에너지 활용을 위하여 에너지 파일의 적용이 확대되고 있다. 특히 더 높은 열 교환 효율을 확보하고자 에너지 파일의 경우 통상적인 U자형 또는 W자형과 같은 라인형 지중 열교환기가 아닌 코일형 지중 열교환기를 매입하는 경우가 늘어나고 있다. 본 연구에서는 매립지 부지에 PHC 코일형 열교환기 형태의 에너지 파일을 설치하고 240시간 동안 현장 열응답 시험(thermal response test)을 실시하였다. 또한 현장에서 지층별로 시료를 채취하여 실내에서 현장 지층 물성으로 시료를 재조성한 후 비정상 탐침법(non-steady state probe method)을 이용하여 지층별 열전도도와 열확산계수를 측정하였고 등가의 열물성으로 환산하였다. 실험 결과 현장 열응답 시험에 의한 지반의 열전도도와 실내 탐침법으로 측정된 지반의 열전도도는 5%내에서 일치하였으며 아울러 지반의 또 하나의 중요한 설계인자인 등가 열확산계수의 측정방법도 제시하였다.

항타 말뚝에서 항타관리시스템(Pile Installation Recorder-Driven Pile)의 적용성에 관한 연구 (Study on Application of PIR-D(Pile Installation Recorder-Driven Pile) in Driven Pile)

  • 박봉근;박민철;최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.28-35
    • /
    • 2004
  • Driven pile has the excellent bearing characteristics and good economics, so it is known as the comparative piling method. To use the advantages of driven pile fully, it is necessary to perform the proper construction management. Engineers must drive pile to the proper bearing layer with proper blow energy and measure the blow count and penetration per certain depth to analyze the bearing capacity and driveability. In conventional method, these parameters have been measured manually so it was difficult to get good accuracy. After PIR-D(Pile Installation Recorder-Driven Pile) was attached to the driving equipment, the hammer efficiency, blow count and penetration in blow/10cm were measured automatically. In this paper, to givethe rational judgement criteria of bearing layer, driveability, blow/10cm according to pile depth during pile driving, the some relationship between the driving resistance and ground layer distribution was analyzed. The ground investigation during piles (PHC ${\Phi}450,\;{\Phi}400\;&\;Steel\;Pile\;{\Phi}609{\ast}16t$) installation in the marine clay layer in Incheon, the sandy soil layer in Yongin and the tuff layer in Pusan was done. And measuring hammer efficiency not doing recently, we could compare hammer efficiency(Eh) by PIR-D and energy transfer ratio(ETR) by Pile Dynamic Analyzer(PDA).

  • PDF