• 제목/요약/키워드: PGM

검색결과 224건 처리시간 0.025초

한국인의 성분비액에서의 Phosphoglucomutase-1(PGM$_1$)아형에 관한 연구 (Studies on the Phosphoglucomutase-1 (PGM$_1$) Subtypes in Sex Secretions in Korean)

  • 최상규;김문규
    • 한국동물학회지
    • /
    • 제31권2호
    • /
    • pp.133-141
    • /
    • 1988
  • 본 연구는 polyacryiamide gel등을 전기영동을 응용, 보존시간에 따른 정액반, 질액반 등에서 PGM$_1$아형의 검출 및 효소활성의 안전성을 조사하여 다음과 같은 결론을 얻었다. (1). 정액반의경우, 실온에서 보존후 7일에는 85%,14일에는 15%의 PGM$_1$아형의 판정이 가능하였고, 21일에는 전혀 판정이 불가능 하였다. (2). 질액반의 경우, 실온에서 보존 후 7일에는 675의 PGM$_1$아형의 판정이 가능하였으나, 14일에는 전혀 불가능 하였다. 한편, 질액에 정액이 혼합된 경우, 질액의 PGM$_1$아형을 판정함으로서, 정액의 PGM$_1$아형의 추정이 가능하였다. 이 결과를 통하여 실제 법생물학 분야에 활용이 가능하다고 인정하였다.

  • PDF

Cloning of phosphoglucomutase gene (pgm) in Streptococcus parauberis

  • Woo, Sung-Ho;Han, Hyun-Ja;Kim, Do-Hyung;Park, Soo-Il
    • 한국어병학회지
    • /
    • 제23권2호
    • /
    • pp.239-244
    • /
    • 2010
  • Here, we have cloned and sequenced Streptococcus parauberis pgm gene, encoding the enzyme phosphoglucomutase (PGM), which is known to be in association with virulence in other streptococcal species. The PGM of S. parauberis is the most closely related to that of S. iniae based on their amino acid sequences.

연속형 시스템의 신뢰성 성장 관리 시험 설계 방안 (A Method of Reliability Growth Management Test Design for Continuous System)

  • 서양우;윤정환;이승상;엄천섭
    • 시스템엔지니어링학술지
    • /
    • 제16권2호
    • /
    • pp.87-96
    • /
    • 2020
  • In this paper we proposed the test design method of reliability growth management. First, we presented the process for establishing the reliability growth management test design considering the number of failures and the termination test time. Reliability growth analysis of continuous system was performed in accordance with the test design process presented. In case the reliability test result is not met with the reliability target value after more than three failures occurred, the required test times were analyzed that 1,725 hrs for one corrective action, 1,950 hrs for two corrective actions. If the number of failures is less than three, design a reliability demonstration test according to confidence level 80% and 90% was performed using RGA 11 Software. As a result, it is possible to establish the reliability growth management test design with sufficient use of available resources. The results of this study can be used when establishing a test design for assessment of reliability growth management of all continuous systems.

유도무기용 관성측정기 수명 시험 설계 및 평가 (Life Test Design and Evaluation of Inertial Measurement Unit for Guided Weapons)

  • 조경환;문상찬;윤석창;권승복;김도형;양일영
    • 항공우주시스템공학회지
    • /
    • 제16권5호
    • /
    • pp.94-101
    • /
    • 2022
  • 본 논문에서는 해외수출용 유도무기체계에 탑재되는 MEMS 관성측정기의 특성과 탑재되는 유도무기체계의 운용 환경 분석을 통해서 신뢰성 입증을 위한 관성측정기 가속계수를 도출하고, 이를 기반으로 관성측정기 수명 시험을 설계하였다. 또한 설계된 수명 시험을 토대로 관성측정기 3조에 대한 수명 시험 수행을 통해 12년의 목표 수명을 입증하였다.

칼코게나이드 유리 소재의 PGM 가공 렌즈를 사용한 저가의 적외선 광학계 설계와 제작 (Design and Fabrication of Low Cost Infrared Optical System Using Precision Glass Molding Lens Made by Chalcogenide Glass)

  • 오승은;이선규;최중규;송국현;백종식
    • 한국광학회지
    • /
    • 제23권4호
    • /
    • pp.154-158
    • /
    • 2012
  • 본 논문에서는 적외선 광학장비의 가격 경쟁력을 확보하고자 상대적으로 저렴한 비용으로 제작이 가능한 PGM(Precision Glass Molding) 가공 렌즈로 구성된, 비냉각형 검출기용 적외선 광학계를 설계 및 제작하였다. PGM 가공이 가능하도록 광학계의 모든 렌즈에 칼코게나이드 유리(Chalcogenide Glass) 소재를 사용하였으며, 자체 비열화가 구현되도록 설계하였다. 또한 기존 가공법인 SPDT(Single Point Diamond Turning) 방법으로 제작된 렌즈로, 동일한 광학계를 구성하여 PGM 가공 렌즈의 성능 측정에 사용하였다. 제작된 두 광학계의 변조전달함수(MTF) 측정 결과와 실제 영상의 촬영 결과를 비교하여 분석한 결과, 가공 방법에 따른 렌즈의 성능 차이는 그리 크지 않음을 확인할 수 있었다. 따라서 향후 PGM 가공 렌즈의 사용이 증가하면, 적외선 광학장비의 가격 경쟁력이 향상될 것으로 기대된다.

Recovery of Pd(II), Pt(IV), and Rh(III) Using Polyelectrolytes

  • Lee, You-Sean;Lee, Hoosung;Chung, Koo-Soon
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.561-568
    • /
    • 1995
  • Two methods, precipitation and ultrafiltration, were applied in order to recover platinum group metals(PGM) by complexing them with water-soluble polyelectrolytes, e.g., polyethyleneimine [PEl], poly(2-vinylpyridine) [2-PVP], poly (4-vinylpyridine) [4-PVP], and poly (styrene sulfonic acid) [PSSA]. In the precipitation method, the PGM-polyelectrolyte complex that was formed by mixing first with polybase, e.g.,4-PVP at pH 1 was precipitated by further mixing with polyacid, e.g., PSSA. However, the recovery of PGM obtained by this method was not quantitative(less than 70%). The "sandwiching" binding between the metal anions and two polyelectrolytes was examined by X-ray photoelectron spectroscopy(XPS). The XPS studies indicated that the PGM atom was bound with the acdic and basic polyelectrolyte via its oxygen and nitrogen atom, respectively. The recovery of PGM using polyelectrolyte was further studied by ultrafiltration methods as follows : The PGM ions, eomplexed at pH 1 with polyelectrolyte, allowed the applicntion of membrane filtration by virtue of the great differences in molecular weights between PGM and other low molecular weight species. By applying this method, Pd and Pt (ca. $10^{-4}M$) were selectively separated almost quantitatively from coexisting metal ions, e.g., $Cu^{2+}$ and $Ni^{2+}$. The EPR spectra and viscosity measurements indicated that these polyelectrlytes were not bound to $Cu^{2+}$ and $Ni^{2+}$ ions at this pH, which provided the basis for selective separation of PGM(Pd, Pt and Rh) from these coexisting ions.

  • PDF

항공기 장착 유도탄의 KW급 전력변환장치 설계와 정류방식에 따른 연구 (A Study on the Design and Rectification Method of a KW class Power Converter Unit for an Aircraft Mounted Guided Missile)

  • 김형재;정재원;이동현;김길훈;문미연
    • 한국항행학회논문지
    • /
    • 제26권2호
    • /
    • pp.99-104
    • /
    • 2022
  • 최근 국내에서도 항공기 플랫폼을 기반으로 한 무기체계 수요는 점진적으로 증가 추세이다. 특히 지상 요격 용도로 항공기에 장착되어 발사 후 수백 킬로미터를 순항한 뒤 표적에 침투하는 유도탄의 수요가 높지만 개발 초기단계이며 그에 따른 연구와 자료 역시 제한적이다. 본 논문은 항공기 플랫폼에 장착 할 공대지 유도탄의 전력변환장치(PCU)에 대한 연구이며 항공기와 유도탄 간 인터페이스인 MIL-STD-1760 기반, 배꼽 연결기의 특성과 구조 그리고 항공기와 전기적 연동 체계에 대해 확인한다. 또한 주요 기능인 유도탄 구성품에 전원을 공급해주는 전력변환장치 설계 사양을 언급하였고, 항공기 장착 상태에서 유도탄 전원 입력 조건이 되는 3상 교류 입력을 모의하여 PFC를 이용한 정류 방식과 브릿지 정류회로를 이용한 정류 방식 결과를 비교 하였다. 이는 추후 개발 될 항공기 장착 무기 체계의 전력변환장치 설계 기초 자료로 사용 될 수 있을 것이다.

Presampled MTF 기법에서 Slant Target의 다양한 각도에 대한 함수 Fitting이 적용된 MTF 측정기법에 관한 연구 (Study of MTF Measure That Adopts a Fitting Curve for the Variable Angle of a Slant Target in Presampled MTF)

  • 최시연;김정환;공현배;김동환;백경훈;박인구;전효원;이기남
    • 한국광학회지
    • /
    • 제33권6호
    • /
    • pp.310-316
    • /
    • 2022
  • Presampled 변조전달함수(MTF) 측정에서 slant 표적각도 변화에 따라 MTF 결과의 차이가 있음을 확인하였고, 표적각도 변화에 대한 오차를 줄이기 위하여 획득한 edge spread function 그래프를 fitting하여 측정값의 오차를 줄일 수 있는 측정기법을 연구하였다. Presampled MTF 방법의 특성상 표적이 회전함에 따라 투영되는 공간주파수의 강도분포는 표적의 회전각도에 따라 변화하며, 이로 인하여 MTF 차이가 발생함을 확인하였다. 이 연구에서는 획득한 영상의 1개의 열에 대해서만 fitting을 한 후 MTF를 계산하였다. Fitting을 이용한 계산은 기존의 presampled MTF 방법과 비교하여 표적 회전에 따른 오차가 줄어듬을 확인하였다. 이 방법은 MTF를 이용한 자동 초점 등 다양한 각도의 표적에 응용이 가능할 것으로 기대된다.

병렬처리 알고리즘 적용 유도탄 점검 (Inspection of guided missiles applied with parallel processing algorithm)

  • 정의재;고상훈;이유상;김영성
    • 한국항행학회논문지
    • /
    • 제25권4호
    • /
    • pp.293-298
    • /
    • 2021
  • 일반적으로 유도무기의 탐색기와 유도조종장치는 유도탄의 상태를 나타내기 위해 표적, 탐색, 인지, 포착정보를 처리하여 유도무기의 운용 및 제어를 담당하는 역할을 한다. 유도에 필요한 신호는 시선 변화율 신호, 시각 신호, 종말 단계 동체 지향 신호이며, 발사 통제에 필요한 신호는 표적, 감지 신호가 필요하다. 최근 유도탄의 복잡하고 처리하기 어려운 유도탄 신호를 실시간으로 처리하기 위해 유도탄의 데이터 처리 속도를 높여야 한다. 본 연구는 PLINQ(Parallel Language-Integrated Query)의 병렬 알고리즘 방법 중 스톱앤고와 역 열거형 알고리즘을 적용한 후 유도탄 점검 프로그램을 이용하여 실시간으로 유도탄 필요 신호 데이터 처리속도를 비교 후 처리결과를 나타내었다. 도출된 데이터 처리결과 기준으로 다중코어 처리방식과 단독코어 처리방식 CPU(Central Processing Unit) 처리속도 비교, CPU 코어 이용률을 비교하고 병렬처리 알고리즘 적용 시 유도탄 데이터 처리에 효과적 방법을 제안한다.

주기적 지연 데이터 처리를 위한 알고리즘 설계 및 테스트 베드 구축 방법 (The algorithm design and the test bed construction method of processing for periodic delayed data)

  • 고상훈;송호진;금남호;유필중;오세권;김영성
    • 한국항행학회논문지
    • /
    • 제27권1호
    • /
    • pp.102-110
    • /
    • 2023
  • 유도탄 체계개발 기간 중 유도탄 기능 점검을 위하여 유도탄 종합점검장비를 제작하여 사용하는데, 장비 제작을 위하여 전원 및 통신 등에 대한 요구사항을 관리한다. 유도탄 종합점검장비 개발자는 유도탄과 통신하는 데이터의 신뢰성 확보를 위하여 제시된 통신 규격에 따라 소프트웨어를 구현한다. 구현 후 테스트베드를 구축하여 자체 성능평가를 수행하고 기준 장비를 이용하여 검증하는 프로세스로 진행하는데, 테스트 베드 구축 시 데이터의 주기적 지연 전송 특성을 반영하여야 한다. 본 논문은 주기적 지연 데이터 처리를 위한 테스트 베드 구축 방법에 대하여 기술하였고, 기존 설계된 알고리즘을 변경하여 성능을 비교 평가 하였다.