• 제목/요약/키워드: PFM

검색결과 252건 처리시간 0.023초

치과 CAD/CAM용 복합소재를 이용한 치과보철물의 제작에 대한 연구 (A Study on Hybrid material of Making Dental restorations by CAD/CAM System)

  • 최범진
    • 대한심미치과학회지
    • /
    • 제23권2호
    • /
    • pp.86-94
    • /
    • 2014
  • In recent years, perhaps the biggest driver in new material development is the desire to improve crown and bridge esthetics compared to the traditional PFM or all-metal restorations. As such, zirconia, leucite-containing glass ceramic and lithium disilicate glass ceramic have become prominent in the dental practice. Each material type performs differently regarding strength, toughness, ease of machining and the final preparation of the material prior to placement. For example, glass ceramic are typically weaker materials which limits its use to single-unit restorations. On the other hand, zirconia has a high fracture toughness which enables multi-unit restorations. This material requires a long sintering procedure which excludes its use for fast chair side production. Developed hybrid material of CAD/CAM is contained nano ceramic elements. This new material, called a Resin Nano Ceramic is unique in durability and function. The material is not a resin or composite. It is also not a pure ceramic. The material is a mixture of both and consists of ceramic. Like a composite, the material is not brittle and is fracture resistant. Like a glass ceramic, the material has excellent polish retention for lasting esthetics. The material is easily machined chair side or in a dental lab, polishes quickly to an esthetic finish and if necessary, can be useful restoratives.

모래분사법과 불투명 도재의 도포방법이 도재용착주조관의 전단결합강도에 미치는 영향 (The Influence of Surface Treatment and Opaque Application Methods on the Bond Strength of PFM Restorations)

  • 김성민;최성민;정인성
    • 대한치과기공학회지
    • /
    • 제33권4호
    • /
    • pp.339-347
    • /
    • 2011
  • Purpose: This study was investigated the bonding strength of two kinds of Ni-Cr alloy with respect to the condition of surface treatment. Methods: The surface treatment was performed on the two kinds of Ni-Cr alloy (B alloy and R alloy) specimens, which were sandblasted with $50{\mu}m$, $110{\mu}m$, and $250{\mu}m$ aluminium oxide and were treated with opaque application (paste and wash opaque). The roughness on the surfaces of the specimens was observed. The metal-ceramic interfaces were analyzed with EPMA in order to ionic diffusion, and the shear test was performed. Results: The BA250 specimen, which has higher surface roughness, showed the highest bonding strength in B specimens. In R specimens, the bonding strength of RA110 specimen was the highest. Conclusion: B specimen formed a mechanical bond between metal-ceramic interfaces; however, in the case of R specimen, a chemical bond was formed between that interfaces. There was no significant statistical difference between the bonding strengths of two types of specimens (p>0.05).

전류제어를 이용한 등기구 전원장치에 관한 연구 (A Study of Lighting Flxtures Power Supply That Use Current Control)

  • 이병선;김영선
    • 전자공학회논문지
    • /
    • 제49권11호
    • /
    • pp.199-204
    • /
    • 2012
  • 지지구 온난화 등과 관련하여 에너지 개발과 절약에 대한 연구가 활발하다. 본 연구에서는 전체 전기에너지 사용의 19%를 차지하는 조명기구 소비전력의 효율적인 절감과 수명연장을 위해 주파수변조와 펄스폭 변조를 혼용한 전류제어 방식의 새로운 형태인 하프브리지형 전원장치를 제안한다. 제안한 전원장치가 갖는 우수성과 안정성에 대해 입증하고 그 특성을 분석 하였다.

Simultaneous Detection of Biomolecular Interactions and Surface Topography Using Photonic Force Microscopy

  • 허승진;김기범;조용훈
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.402.1-402.1
    • /
    • 2014
  • Photonic force microscopy (PFM) is an optical tweezers-based scanning probe microscopy, which measures the forces in the range of fN to pN. The low stiffness leads proper to measure single molecular interaction. We introduce a novel photonic force microscopy to stably map various chemical properties as well as topographic information, utilizing weak molecular bond between probe and object's surface. First, we installed stable optical tweezers instrument, where an IR laser with 1064 nm wavelength was used as trapping source to reduce damage to biological sample. To manipulate trapped material, electric driven two-axis mirrors were used for x, y directional probe scanning and a piezo stage for z directional probe scanning. For resolution test, probe scans with vertical direction repeatedly at the same lateral position, where the vertical resolution is ~25 nm. To obtain the topography of surface which is etched glass, trapped bead scans 3-dimensionally and measures the contact position in each cycle. To acquire the chemical mapping, we design the DNA oligonucleotide pairs combining as a zipping structure, where one is attached at the surface of bead and other is arranged on surface. We measured the rupture force of molecular bonding to investigate chemical properties on the surface with various loading rate. We expect this system can realize a high-resolution multi-functional imaging technique able to acquire topographic map of objects and to distinguish difference of chemical properties between these objects simultaneously.

  • PDF

마그네트론 스퍼터용 모듈형 20kW 플라즈마 전원장치에 대한 연구 (The Study of Module Type 20kW Plasma Power Supply for Magnetron Sputter)

  • 한희민;서광덕;조용규;김준석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.56-58
    • /
    • 2006
  • 본 논문은 PVD(Physical Vapor Deposition)의 마그네트론 스퍼터(Magnetron sputter) 박막코팅(Thin film coating) 공정에서 플라즈마(Plasma)를 발생시키고 제어하는 DC 전원공급 장치에 관한 것이다. 이 논문에서는 임피던스의 변화가 심하고 아크(Arc)가 빈번히 발생하는 플라즈마 부하의 특성에 대해, 과도상태(Transient state)의 출력제어 성능을 향상시키고 아크 발생 시 부하로 전가되는 아크에너지를 저감시키기 위한 직류 전원 공급 장치에 대해 소개한다. 전원장치는 수하특성을 가지며 플라즈마 부하에 적합한 출력 제어성을 확보하고 아크 에너지를 최소화하기 위해 고주파 L-C 직렬공진회로 기법을 적용한다. 개발된 DC 20kW급 전원 장치는 인버터와 고주파 절연변압기, 정류기로 구성된다. 인버터는 $100{\sim}200kHz$의 제어주파수로 PFM 및 PWM 제어를 하며, 단위용량 5kW급 컨버터 4개를 직, 병렬 연결하여 출력리플을 최소화 하였다. 개발된 장치의 우수한 제어성능은 실제 플라즈마 공정에서 시험 평가한 결과를 통해 검증할 수 있었다.

  • PDF

Focal epithelial hyperplasia arising after delivery of metal-ceramic fixed dental prosthesis

  • Park, Min-Woo;Cho, Young-Ah;Kim, Soung-Min;Myoung, Hoon;Lee, Jong-Ho;Lee, Suk-Keun
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권6호
    • /
    • pp.555-558
    • /
    • 2014
  • Focal epithelial hyperplasia (FEH) is a human papillomavirus (HPV)-induced alteration of the oral mucosa that presents with a clinically distinct appearance. While other HPV-infected lesions such as squamous papilloma, verruca vulgaris, and condyloma acuminatum involve the skin, oral mucosa, and genital mucosa, FEH occurs only in the oral mucosa. The affected oral mucosa exhibits multiple papules and nodules with each papule/nodule being flat-topped or sessile. The affected region resembles the normal color of oral mucosa rather than appearing as a white color since the epithelial surface is not hyperkeratinized. Almost all cases present with multiple sites of occurrence. This rare, benign epithelial proliferation is related to low-risk HPV, especially HPV-13 and -32, and is not transformed into carcinoma. We report a case of FEH that arose on the attached gingiva of an East Asian male adult related to prosthesis without detection of any HPV subtype in HPV DNA chip and sequencing.

도재 전장 금관용 비귀금속 합금의 결합강도에 관한 연구 (A study on the Bond Strength of Non-Precious Alloys Used for the Porcelain Fused to Metal Crown)

  • 김철만;이종혁;조인호
    • 구강회복응용과학지
    • /
    • 제22권3호
    • /
    • pp.203-210
    • /
    • 2006
  • Although porcelain fused to metal crowns made from non-precious metal have good mechanical properties, they also have disadvantages such as the poor biological acceptability and the low corrosional resistance. Titanium is used as the alternative metal for porcelain fused to metal crowns, in spite of difficulties in casting. For that reason non-precious alloy including titanium which is easy to cast is currently used. This study evaluated the bond strength between non-precious alloy including titanium and Ni-Cr alloy. $Tilite^{(R)}V$ as non-precious alloy including titanium, $Rexilium^{(R)}V$ as Ni-Cr alloy and $Omega900^{(R)}$ and $Vintage(Regular)^{(R)}$ as porcelain powders were used. The results were as follows. 1. In comparison with the kind of alloy, the bond strength of $Tilite^{(R)}V$ was lower than that of $Rexilium^{(R)}V$. There was no significant difference between two groups. 2. In comparison with the kind of porcelain powder, the bond strength of $Omega900^{(R)}$ was higher than that of $Vintage(Regular)^{(R)}$ in $Tilite^{(R)}V$. There was significant difference between two groups(p < 0.05).

도재용착용 비귀금속 합금(Co-Cr)과 세라믹의 소성술식에 따른 전단결합강도 분석 (An analysis of shear bond strength of Co-Cr alloy of porcelain fused to metal and ceramic)

  • 임중재
    • 대한치과기공학회지
    • /
    • 제39권3호
    • /
    • pp.153-159
    • /
    • 2017
  • Purpose: In this study, a corresponding porcelain coating material was applied to dental Co-Cr metal among PFM. Methods: The bonding strength of the fired specimens was measured by a three-point flexural rigidity test. SEM/EDS was used to observe the surface component of specimens. Results: First, All groups were higher than the minimum bonding strength of 25 MPa specified in ISO 9693 for dental metal-ceramics specimens. Second, The bonding strength of control group(WO) is 44.64 MPa. Experimental group DM was 35.45 MPa and DP was 31.82 MPa(P<0.05). Tukey's HSD tests results have shown that the bonding strength in control group(WO) is higher than that of experimental group(DM, DP). Third, In the case of metal - porcelain bonding strength, the application of opaque porcelain and firing were higher than those of the group treated with degassing process. Conclusion: The bonding strength was higher when the powder opaque porcelain was applied than the paste opaque porcelain.

휴대용 배터리 구동 시스템을 위한 8V-12V 내장형 CMOS DC-DC 컨버터 (The Embedded 8V-to-12V CMOS DC-DC Converter for a Mobile Battery-Powered System)

  • 오원석;이승은;이성철;박진;최종찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2577-2579
    • /
    • 2002
  • In this paper, we describe a CMOS DC-DC converter with a variable output voltage(8-12V @100mA) for a portable battery-operated system applications. The proposed DC-DC converter is used along with a Pulse-Frequency Modulation (PFM) method and consists of a reference circuit, a feedback resistor, a controller, and an internal oscillator. The integrated DC-DC converter with two external passive components(L.C) has been designed and fabricated on a 0.6${\mu}m$ 2-poly, 3-metal CMOS process and could be applied to the Personal Digital Assistants(PDA), Cellular Phone, Laptop Computer, etc.

  • PDF

도재용착주조관용 비귀금속 합금의 사전 열처리가 도재-금속의 결합 강도에 미치는 효과 (The Effect of Oxidation Heat Treatment on Porcelain to Metal Bond Strength)

  • 김치영;남상용
    • 대한치과기공학회지
    • /
    • 제19권1호
    • /
    • pp.37-42
    • /
    • 1997
  • The interfacial bond strengh and microstructural analysis of pre-heat treated porcelain-fusedmetal(PFM) were investigated using a mechanical three-point bending tester and scanning electron microscope(SEM). Four kinds of heat treated samples were prepared as follows ; A: Heating $1200^{\circ}F{\to}1600^{\circ}F$, holding 1min, reheating ${\to}1850^{\circ}F$, hold 3min under vacuum, B: heating $1200^{\circ}F{\to}1600^{\circ}F$, holding 1min, reheating${\to}1850^{\circ}F$ under vacuum conditon, C: heating $1200^{\circ}F{\to}1600^{\circ}F$, holding 1min, reheating${\to}1850^{\circ}F$, holding 3min in the air, repeat same heat treatment process under vacuum condition, D: heating $1200^{\circ}F{\to}1600^{\circ}F$, holding 1min, reheating${\to}1850^{\circ}F$, holding 1min in the air. The three-point bening test result shows that the interfacial bond strength of specimen B and C were higher than that of A and D. The SEM study indicate that Specimen C shows the highest surface density.

  • PDF