A Study on Input${\cdot}$Output Waveform Solutions and Harmonics Analyses for a Novel PFC Step-up Converter (새로운 PFC 스텝-업 컨버터의 입출력 파형해석 및 고조파분석에 관한 연구)

  • Kwak Dong-Kurl
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.12
    • /
    • pp.622-628
    • /
    • 2005
  • This paper is given a full detail of mathematical analyses of input current and output voltage for a novel active type power factor correction (PFC) converter. These are compared with harmonics components of input current for a conventional PFC converter. The proposed PFC converter is constructed in using a new loss-less snubber circuit to achieve a soft switching of control device. Also the proposed converter for discontinuous conduction mode (DCM) eliminates the complicated circuit control requirement and reduces the size of components. The input current waveform in the proposed converter is got to be a sinusoidal form of discontinuous pulse in proportion to magnitude of ac input voltage under the constant duty cycle switching. Therefore, input power factor is nearly unity and the control method is simple. Particularly, the stored energy of loss-less snubber capacitor is recovered with input side and increases input current from resonant operation. The result is that input power factor of the proposed converter is higher than that of conventional PFC converter. Some simulative results on computer and experimental results are included to confirm the validity of the analytical results.

Perfluorocarbon Does Not Inhibit Chemokine Expression in Airway Epithelial Cells (Perfluorocarbon이 기도 상피세포 Chemokine 발현에 미치는 영향에 관한 연구)

  • Suh, Gee-Young;Kang, Kyeong-Woo;Park, Sang-Joon;Chung, Man-Pyo;Kim, Ho-Joong;Choi, Dong-Chull;Rhee, Chong-H;Kwon, O-Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.2
    • /
    • pp.223-235
    • /
    • 2000
  • Background: Liquid ventilation is associated with decreased inflammatory response in an injured lung. This study was performed to investigate if whether perfluorocarbon(PFC) can decrease chemokine expression in airway epithelial cells. Methods: A549 cells were used for airway epithelial cells and perfluorodecalin for PFC. To expose cells to PFC, lower chamber of Transwell$^{(R)}$plate was used. This study was performed in two parts. In the first part, we examined whether PFC could decrease chemokine expression in airway epithelial cells through inhibition of other inflammatory cells. Peripheral blood mononuclear cells(PBMC's) were isolated and stimulated with lipopolysaccharide(LPS, 10 ${\mu}g/mL$) for 24 hours with or without exposure to PFC. Then A549 cells were stimulated with conditioned media(CM) containing the culture supernatants of PBMC. After 24 hours, the expressions of interleukin-8(IL-8) and RANTES were measured. In the second part of the study, we studied whether PFC could directly suppress chemokine expression in airway epithelial cells. A549 cells were stimulated for 24 hours with interleukin-l$\beta$ and/or tumor necrosis factor-$\alpha$ with or without exposure to PFC, and then the chemokine expression was measured. Northern analysis was used to measure the mRNA expression, and ELISA was used for immunoreactive protein measurements in culture supernatant. Results: 1. IL-8 and RANTES mRNA expression and immunoreactive protein production were increased significantly by CM from LPS-stimulated PBMC in A459 cells compared to with CM from unstimulated PBCM (p<0.05), but exposure of PFC had no significant effect on either mRNA expression or immunoreactive protein expression. 2. IL-8 and RANTES mRNA expression and immunoreactive protein production were increased significantly by IL-1$\beta$ and TNF-$\alpha$ in A549 cells(p<0.05), but exposure of PFC had no significant effect on neither either mRNA expression nor immunoreactive protein production. Conclusion : Decreased chemokine expression of airway epithelial cells may not be involved in decreased inflammatory response observed in liquid ventilation. Further studies on possible mechanisms of decreased inflammatory response are warranted.

  • PDF

The characteristic comparison of power factor correction circuits for electronic ballasts (전자식 형광등용 역율 개선 회로의 특성 비교)

  • Park, Chong-Yeon;Cho, Gye-hyun
    • Journal of Industrial Technology
    • /
    • v.18
    • /
    • pp.165-172
    • /
    • 1998
  • In recent years, various power factor correction(PFC) circuits for the electronic ballast have been proposed. And these circuits have difference characteristics each other. We have researched several PFC circuits of them. And operational principles and characteristics of PFC circuits are compared by the cost and the electrical performance. Finally, we established the reference for the evaluation of PFC circuits with performance and the price.

  • PDF

Simulation and Experimentals of a Bi-Directional Converter with Input PFC on SRM System

  • Maged Maged N.F.
    • Journal of Power Electronics
    • /
    • v.6 no.2
    • /
    • pp.121-130
    • /
    • 2006
  • This paper presents the performance and efficiency of a drive system incorporating a switched-reluctance motor (SRM) with input power factor correction (PFC). The proposed system consists of a PFC, bi-directional converter, an inverter, and a SRM operating as based voltage source drives (VSD). First, theoretical analysis is made for each identified mode of operation in the drive system. This is followed by comparing the performance of the SRM drive system with and without a PFC circuit. The losses are also calculated for both systems and overall efficiency. Experimental results are presented to prove the theoretical analysis.

PFC control method using the charging current of the capacitor (커패시터 충전 전류를 이용한 PFC 제어 방법)

  • Lee, Seung-Heyon;Lee, Chi-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.13-14
    • /
    • 2014
  • This paper is proposed the PFC control method of boost converter using a charging current of the capacitor. Around AC voltage peak point, PFC operation is stopped and the charging current of the capacitor is flowed. The charging current of the capacitor and the switching current makes the AC input current. The 150[W] converter was confirmed high PF and low THD.

  • PDF

Membrane Characteristics for Removing Particulates in PFC Wastes (PFC제염폐액 내의 미립자 제거를 위한 여과막의 특성 연구)

  • Kim Gye-Nam;Lee Sung-Yeol;Won Hui-Jun;Jung Chong-Hun;Oh Won-Zin;Park Jin-Ho
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.2
    • /
    • pp.149-157
    • /
    • 2005
  • PFC(Perfluorocarbon) decontamination process is one of best methods to remove hot particulate adhered at inside surface of hot cell and surface of equipment in hot cell. It was necessary to develop a particulate filtration equipment to reuse PFC solution used on PFC decontamination due to its high cost and to minimize the volume of second wastewater. Contamination characteristics of hot particulate were investigated and then a filtration process was presented to remove hot particulate in PFC solution generated through PFC decontamination process. The removal efficiency of PVDF(Poly vinylidene fluoride), PP(Polypropylene), Ceramic(Al$_{2}$O$_{3}$ filter showed more than 95$\%$. The removal efficiency of PVDF filter was a little lower than those of other kiters at same pressure(3psi). A ceramic filter showed a higher removal efficiency with other filters, while a little lower flux rate than other filters. Due to inorganic composition, a ceramic filter was highly stable against radio nuclides in comparison with PVDF and PP membrane, which generate H$_{2}$ gas in e-radioactivity atmosphere. Therefore, the adoption of ceramic filter is estimated to be suitable for the real nitration process.

  • PDF

The Separation of Particulate within PFC Decontamination Wastewater Generated by PFC Decontamination (PFC 제염 후 발생된 제염폐액 내 오염입자의 제거)

  • Kim Gye-Nam;Lee Sung-Yeol;Won Hui-Jun;Jung Chong-Hun;Oh Won-Zin;Park Jin-Ho;narayan M.
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.32-39
    • /
    • 2005
  • When PFC(Perfluorocarbonate) decontamination technology is applied to removal of radioactive contaminated particulate adhered at surface during the operation of nuclear research facilities, it is necessary to develop a filtration equipment to reuse of PFC solution due to high price, also to minimize the volume of second wastewater. Contaminated characteristics of hot particulate was investigated and a filtration process was presented to remove suspended radioactive particulate from PFC decontamination wastewater generated on PFC decontamination. The range of size of hot particulate adhered at the surface of research facilities measured by SEM was $0.1{\sim}10{\mu}m$. Hot particulate of more than $2{\mu}m$ in PFC contamination wastewater was removed by first filter and then hot particulate of more than $0.2{\mu}m$ was removed by second filter. Results of filter experiments showed that filtration efficiency of PVDF(Poly vinylidene fluoride), PP(Polypropylene), Ceramic filter was $95{\sim}97\%$. A ceramic filter showed a higher filtration efficiency with a little low permeate volume. Also, a ceramic of inorganic compound could be broken easily on experiment and has a high price but was highly stable at radioactivity in comparison of PVDF and PP of a macromolecule which generate $H_2$ gas in alpha radioactivity environment.

  • PDF

PFC Ultrasonic Decontamination Efficiency on the Various Types of Metal Specimens (금속 시편 형태에 따른 PEC 초음파 제염 성능)

  • Won Hui-Jun;Kim Gye-Nam;Jung Chung-Hun;Park Jin-Ho;Oh Won-Zin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.4
    • /
    • pp.293-300
    • /
    • 2005
  • Ultrasonic decontamination of the type 304 stainless steel specimen loosely contaminated with $Eu_2O_3$ powders was investigated. Decontamination factors (DFs) by the three kinds of ultrasonic media such as water, pure PFC (Pefluorocarbon, $C_7F_{16}$) and a mixed solution of $99.9\;vol\%\;PFC\;and\;0.1\;vol\%$ anionic surfactant were determined. The determined DF values were 20, 50 and 200, respectively. This significant difference in the decontamination factors for the different decontamination solution was well explained by the surface tension of the media as well as the interaction between the positively charged surface of $Eu_2O_3$ powders and the anionic surfactant. Ultrasonic decontamination behavior of the loosely contaminated metal specimens such as plate, pipe, welding specimen and crevice specimen in the mixed solution of PFC and anionic surfactant was also investigated. The contaminants were completely removed for the tested specimens except for the longest specimen. For 6-cm long pipe specimen, however, $98.5\%$ of the contaminants were removed.

  • PDF

Performance Analysis of Single-phase SRM Drive System with Single-stage Power Factor Correction (1단구조방식의 PFC회로를 갖는 단상 SRM 구동시스템의 특성해석)

  • Lee, Dong-Hee;Lee, Jin-Kuk;An, Young-Ju;Ahn, Jin-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.328-339
    • /
    • 2006
  • In this paper the characteristic analysis of a single-phase switched reluctance motor (SRM) drive system with power factor correction (PFC) circuit is presented. The SRM is a low cost, simple and has a good high speed performance. The SRM drive with diode rectifier and filter capacitor has a low power factor because of short switch on time of capacitor. A novel switching topologic is presented to improve power factor and reduce torque ripple based on analysis of PFC circuit. Accordingly the SRM drive system with PFC circuit is also presented. Through the numerical analysis of the system, the toque ripple, power factor and efficiency with the change of rotary speed, load torque and capacity of the capacitor are achieved and compared with actual measured value.

Improved AC/DC PFC ZVT Boost Converter (개선된 AC/DC PFC ZVT Boost 컨버터)

  • Ryu, Jong-Gyu;Kim, Yong;Bae, Jin-Yong;Lee, Eun-Young;Cho, Kyu-Man
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.62-69
    • /
    • 2005
  • This paper presents the improved AC/DC PFC(Power-Factor-Correction) ZVT(Zero-Voltage-Transition) Boost Converter. The conventional AC/DC PFC ZVT Boost Converter minimizes the switching loss of the main switch within all of the load range. That is because AC/DC PFC ZVT Boost converter makes the main switch and the auxiliary switch turn on simultaneously so that it makes ZVS (Zero-Voltage-Switching) possible at the light load. However, it has two problems that ale large loss of the auxiliary switch and the increasing of the reverse current of the main switch. Therefore this research presents high efficiency to reduce the current stress of the auxiliary switch and the reverse current of main switch by adding a diode to the conventional ZVT converter. The prototype of 640[W], 100[kHz] system using MOSFET is implemented for this experimental verification.