Conducted Noise Reduction in PFC Boost Converter for Air Conditioner (에어컨용 PFC Boost Converter의 전도 노이즈 저감)

  • Lee S.H.;Kim L.H.;Kim Y.G.;Won C.Y.;Kim T.D.;Kim D.K.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.793-797
    • /
    • 2003
  • Switching PFC converters are widely used not only to comply the power quality specification but also for maximum efficiency. However switching PFC converters generate serious electromagnetic interference (EMI). In this paper to solve this problem, we applied the APW(Anti Phase Winding) and RPWM(Ran-dom PWM) technique to PFC boost converter and obtained satisfactory results. Simulation and experimental results show the improved harmonic and reduced EMI effect in air-conditioner system.

  • PDF

High Power Factor High Efficiency PFC AC/DC Converter for LCD Monitor Adapter (LCD 모니터의 어댑터를 위한 고역률 고효율 PFC AC/DC 컨버터)

  • Park K. H.;Kim C. E.;Youn M. J.;Moon G. W.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.85-89
    • /
    • 2003
  • Many single-stage PFC(power-facto.-correction) ACHC converters suffer from the high link voltage at high input voltage and light load condition. In this paper, to suppress the link voltage, a novel high power factor high efficiency PFC AC/DC converter is proposed using the single controller which generates two gate signals so that one of them is used far gate signal of the flyback DC/DC converter switch and the other is applied to the Boost PFC stage. A 130w prototype for LCD monitor adapter with universal input $(90-265V_{rms})$ and 19.5V 6.7A output is implemented to verify the operational principles and performances. The experimental results show that the maximum link voltage stress is about 450V at 270Vac input voltage. Moreover, efficiency and power factor are over $84\%$ and 0.95, respectively, under the full load condition.

  • PDF

Soft Switching Bridgeless PFC Buck Converters

  • Emrani, Amin;Mahdavi, Mohammad;Adib, Ehsan
    • Journal of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.268-275
    • /
    • 2012
  • Based on the standards that limit the harmonic pollution of electronic systems, the use of PFC converters is mandatory. In this paper, a new resonant bridgeless PFC converter is introduced. By eliminating the input bridge diodes, the efficiency is improved. Moreover, soft switching conditions for all of the semiconductor elements are achieved without adding any extra switches. As a result, high efficiency is attained. The proposed converter is analyzed and the theoretical and simulation results of the proposed converter are presented. In order to verify the validity of the analysis, a 40 w prototype converter is implemented and experimental results are presented. The experimental results show that high efficiency is attained while achieving a high power factor.

Analysis of the Admittance Component for Digitally Controlled Single-Phase Bridgeless PFC Converter

  • Cho, Younghoon;Mok, Hyungsoo;Lai, Jih-Sheng
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.600-608
    • /
    • 2013
  • This paper analyzes the effect of the admittance component for the digitally controlled single-phase bridgeless power factor correction (PFC) converter. To do this, it is shown how the digital delay effects such as the digital pulse-width modulation (DPWM) and the computation delays restrict the bandwidth of the converter. After that, the admittance effect of the entire digital control system is analyzed when the bridgeless PFC converter which has the limited bandwidth is connected to the grid. From this, the waveform distortion of the input current is explained and the compensation method for the admittance component is suggested to improve the quality of the input current. Both the simulations and the experiments are performed to verify the analyses taken in this paper for the 1 kW bridgeless PFC converter prototype.

A Study on the Continuous Current Mode $S^4$-PFC Converter using Auxiliary Resonant Circuit (공진형 보조 회로를 이용한 연속 전류 모드 $S^4$-PFC 컨버터에 관한 연구)

  • Han, Dae-Hee;Kim, Yong;Bae, Jin-Yong;Lee, Eun-Young;Kwon, Soon-Do
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.200-203
    • /
    • 2002
  • This paper presents Continuous-current mode of $S^4$-PFC(Single-Stage Single-switch Power Factor Correction) converter. Proposed converter operates in the continueous current mode(CCM) at full load and discontinuous current mode(DCM) at light load. So, characteristic of proposed converter is no bus voltage stress and Zero Voltage Switching(ZVS) using resonant auxiliary circuit. And. This paper presents characteristic of $S^4$-PFC converter and effect of circuit parameter of proposed converter through the input inductor, PFC capacitor's variation. All of these theory and characteristic verified through the experiment with a 72W(12V, 6A), $90^{kHz}$ prototype converter.

  • PDF

Separation and Extraction of Hot Particulate from contaminated Perfluorocarbon solution

  • Kim Gye-Nam;Narayan Mathuresh;Wou Hui-Jun;Jung Chong-Hun;Oh Won-Zin
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.70-71
    • /
    • 2005
  • It was an idea to develop a system to remove the contaminated hot particulate to make clean nuclear research facilities to the clear visibility for researcher. In order to clean micron and sub micron size particulates from used PFC solution as a decontamination tool. Since PFC solution is very expensive so it was a high recommendation to develop the some filtration equipment to purify PFC for next decontamination process, in additionally, reduce the secondary waste. However, we developed an easy and economic filter system to purify the PFC solution. The major advantage of the process operates in closed loop under near ambient conditions, thus minimizing the potential for fugitive TRU emissions and reduces the secondary waste. This has very significant safety and cost impacts. Here we proposed the two types PFC filter systems.

  • PDF

A study on the characteristics of power factor correction circuits with input active boost converter (입력 능동 부스트 컨버터를 고려한 역률개선회로의 특성분석)

  • Jang, Jun-Young;Lee, Kwan-Yong;Kim, Cherl-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.270-272
    • /
    • 2003
  • Switching power supplies are widely used in many industrial fields. Power factor correction(PFC) circuits have tendency to be applied in new power supply designs. The input active power factor correction(APFC) circuits can be implemented using either the two-stage approach or the single-stage approach. The single-stage PFC circuit has advantage to reduce the number of components by eliminating a need for the PFC switch and control circuit. However, unlike in the two-stage approach, the do voltage on the energy storage capacitor in a single-stage PFC circuit is not well regulated. As a result. in universal line application($90{\sim}265Vac$), the storage capacitor voltage varies with the load and line variation. In this paper, the performance of output voltage regulation and transient response are clarified here. The validity of designed boost PFC circuit is confirmed by MATLAB simulation and experimental results of 2 [kW] prototype converter.

  • PDF

High Efficiency and High Power Density 3-Level Power Factor Correction Converter (고효율 및 고전력밀도 3-레벨 PFC 컨버터)

  • Yang, Jung-woo;Ji, Sang-Keun;Kang, Jeong-il;Han, Sang-Kyoo
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.207-209
    • /
    • 2018
  • 본 논문은 고효율 및 고전력밀도 3-레벨 PFC(Power Factor Correction) 컨버터를 제안한다. 기존 PFC의 고 전력밀도를 위한 스위칭 주파수 상승은 스위칭 특성이 우수한 소자를 적용하거나, 별도의 스너버 회로가 요구되므로 설계가 복잡하며 고전력밀도 달성에 한계가 있다. 제안 PFC 컨버터는 3-레벨 방식을 적용하여 각 스위칭 소자의 전압 스트레스를 절반으로 감소시켰으며, 스위치 손실 저감을 통한 고속 스위칭 동작으로 리액티브 소자의 고밀도화를 달성하였다. 또한, 기존의 3-레벨방식은 디지털 제어를 통해 스위칭 소자의 전압 평형이 이루어졌지만, 본 논문에서는 아날로그 IC에 전압 평형을 위한 RC Delay 회로와 소수의 SMD(Surface-mount devices) 소자만을 이용하여 별도의 제어회로 없이 전압 평형이 가능하므로 고 전력밀도 달성에 유리하다. 제안회로의 타당성을 검증하기 위해 CRM(Critical conduction mode) PFC 컨버터를 기반으로 250W급 시작품 제작을 통한 실험 결과를 제시한다.

  • PDF

Digital Implementation methode of Totem-pole PFC using GaN Transistor (GaN 트랜지스터를 적용한 토템폴 역률개선회로의 디지털 구현방법)

  • Kwak, Bongwoo;Kim, Myungbok
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.120-121
    • /
    • 2019
  • 본 논문은 GaN 트랜지스터를 적용한 토템폴 PFC(Power Factor Correction)의 디지털 구현을 위한 방법을 제시한다. 특히, GaN 트랜지스터의 낮은 역회복 특성으로 토템폴 PFC의 연속 연속 모드 동작을 가능하게 한다. 토템폴 PFC는 고속 스위칭을 하는 레그를 GaN 트랜지스터를 사용하고, 라인 주파수로 스위칭 하는 레그는 일반적인 MOSFET을 사용하게 된다. 구조적으로 토템폴 PFC는 제로 크로싱에서 전류 스파이크 문제가 발생한다. GaN 트랜지스터는 전류 스파이크에 취약하기 때문에 최소화되어야 한다. 따라서, 본 논문은 디지털 구현에 있어 제로 크로싱에서 소프트 스타트 구현을 통해 이 문제를 최소화 하고, 모의실험을 통해 디지털 구현의 타당성을 입증하였다.

  • PDF

A Study on PFC-Inverter Soft-Switching (소프트-스위칭 PFC-인버터에 대한 연구)

  • Lee, S.R.;Kwon, S.S.;Joo, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1212-1214
    • /
    • 2000
  • A new soft-switching PFC-Inverter for Induction Motor's operation with single phase or three phase medium size is proposed. In order to improve the power factor and the efficiency, in this paper, the ZVT topology in the conventional PFC-Inverter is adopted. So, the operation mode of the proposed ZVT PFC-inverter is analyzed and the optimum circuit is designed. At last, the PSPICE simulation and experiment results are presented in order to verify the validity of the proposed circuit.

  • PDF