• Title/Summary/Keyword: PET fiber

Search Result 464, Processing Time 0.019 seconds

Assessments of Creep Properties of Strip Type fiber Reinforcement (띠형 섬유보강재의 크리프 특성 평가)

  • 전한용;유중조;김홍택;김경모;김영윤
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.2
    • /
    • pp.279-289
    • /
    • 2003
  • Geosynthetic reinforced earth wall was introduced about 20 years ago and many structures have been constructed. Especially, segmental concrete panel facing and friction tie system are the most popular system in Korea, and this friction tie was composed of high tenacity PET filament and LDPE(Low Density Polyethylene) sheath. Due to the lack of direct-test results, design coefficients of friction tie (creep reduction factor) had been determined by quoting the previous and the foreign reference data. This is an unreasonable fact for the use of friction ties. In this study, the creep tests were performed to evaluate the creep behavior of friction tie, and the reduction factor of creep was calculated for the correct design of geosynthetic reinforced earth retaining walls. From the test results, finally it was found that the allowable creep strength of friction tie is 60% of Tult during service life, and creep reduction factor is 1.67 for each grade of friction ties.

Development of antibacterial PLA fiber to relieve atopy irritation (아토피완화용 PLA 항균사 개발)

  • Yong, Kwang-Joong;Nam, Seung-Min;Ham, Jin-Soo;Yang, Kwang-Wung;Rho, Yong-Hwan
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2011.11a
    • /
    • pp.52-52
    • /
    • 2011
  • PLA 섬유는 폴리머의 주성분이 옥수수에서 추출한 모노머를 중합한 화학섬유가 아닌 인체친화적인 식물성 소재이며 생분해성이 좋은 친환경 소재로 최근 주목받고 있는 섬유소재이다. 본 연구에서는 아토피완화용 여러 섬유 구조체 개발에서 사용되는 섬유소재중 PLA 원사에 항균성 물질을 혼입하여 PLA 항균사 제조를 위한 연구를 수행하였다. PLA Grade의 점도가 낮아질수록 Grade별 용융 지수값은 차이를 나타내지만 방사온도 $230^{\circ}C$를 변곡점으로 하여 용융점도가 급격히 변하였으며, 특히 방사온도 $240^{\circ}C$의 경우 용융지수가 100을 넘어가고 폴리머의 색깔이 황갈색을 띄어 폴리머의 열분해가 많이 일어났을 것으로 판단되었다. PLA의 적정 방사온도 구간은 $210{\sim}225^{\circ}C$ 구간이 최적이며 그 이상에서는 Color 변화 및 물성 저하가 나타나는 것으로 판단되었다. 항균성 PLA 섬유를 제조하기 위하여 피톤치드계 유기항균제를 이용하였으며, 피톤치드에 기능성 엘라스토머를 사용하여 Capsulation을 진행하였다. 이러한 유기항균제 Powder의 경우 비중이 낮아 표면적로 인하여 마스터배치 칩을 만드는 공정에서 잘 혼합되지 않는 문제점이 발생하였으나, 피톤치드의 함량을 조절하여 PLA와의 마스터배치 칩 제조를 시험하였다. 압출온도와 토출량, Screw 조건(Mixing, Zone)을 시험하여 적정 조건을 설정하였다. 항균사 PLA 섬유는 Sheath/Core 복합방사 형태와 단독사 형태의 2가지 Type을 제조하였다. Sheath/Core 복합방사 폴리머 구성은 Sheath부에 PLA항균사, Core부에 PLA 또는 저융점 PET를 사용하였다. Core부의 폴리머는 제사성에 큰 영향을 미치지 않았으나, 항균 마스터배치의 함량이 증가할수록 Pack압 상승이 급격히 일어나는 단점이 나타났다. 항균제 5% 정도가 혼입되어 있는 경우에 2.1 이상의 정균활성치와 99.8% 정도의 정균감소율 성능을 나타내었다. PLA 단독사의 경우, 항균제 최적 함량은 3% 이상으로 정균활성치 5.5 이상, 정균감소율 99.9%의 우수한 항균특성을 나타내었다.

  • PDF

A Study on the Application of Medical Compression Arm Sleeves Using a MRT(Moisture Responded Transformable) Fibers (MRT(Moisture Responded Transformable)섬유의 의료용 압박소매 적용에 관한 연구)

  • Cho, Daehyun;Jung, Taedu;Park, Eunhee;Park, Youngmi
    • Textile Coloration and Finishing
    • /
    • v.33 no.2
    • /
    • pp.87-95
    • /
    • 2021
  • In this study, the application of a medical compression sleeve of Moisture Responded Transformable(MRT) fibers to the treatment of lymphedema after surgery in breast cancer patients was investigated. MRT fibers were manufactured with PET and Nylon6 bi-component cross-section yarns, and compression sleeves of sleeves 1, 2, 3, and 4 were knitted in order of size, and then the physical properties and clinical tests were evaluated. As a result, the pressure of compression sleeve in wrinkle was the lowest in sleeve 1 with 3.81 kPa, and the highest in sleeve 4 with 5.22 kPa. Elastic recovery rate is that all parts except the top of the sleeve 1 exhibited 100%. The air permeability was good at 12.1 ~ 16.1 cm3/cm2/sec, and peeling was also comparatively excellent as grade 3. In addition, the weight of the compression sleeves 1, 2, and 3 decreased as 18.3 ~ 23.0 g/m2 depend on size, while the compared sample was heavier with 17.39 ~ 32.61 g/m2. In lymphoscintigraphy test, it was confirmed that the function of remaining lymph node was good in all patients. Although there were no differences between samples in skin irritation and tightness in wearing comfort, the manufactured sleeves showed better fit, lightness, fashion and breathability than the comparable sleeves.

Water Treatment Application of a Large Pore Micro-Filtration Membrane and Its Problems (대기공 정밀여과막의 수처리 응용 및 문제점)

  • Yun, Chang-Han;Kim, Jeong-Hak;Lee, Kang Won;Park, Sung Ho
    • Membrane Journal
    • /
    • v.24 no.3
    • /
    • pp.194-200
    • /
    • 2014
  • The purpose of this study was to evaluate the performance of newly developed Large Pore Micro-Filtration (LPMF) membrane in Lab size for the application of water treatment, and to find its problems with solutions. The out-to-inside filtration hollow fiber LPMF membrane of which average pore size was $5{\mu}m$ was used at this study and its material was the PET braid reinforced PVDF. Filtration tests were done through gravity with 30 cm water head difference or pressure below 1.5 bar, and the backwash was done instantaneously with the filtrate after pressurizing it to about 4 bar. The water flux of the LPMF membrane with 0.2 bar TMP (Trans Membrane Pressure) was 2 times higher than $0.4{\mu}m$ MF membrane with $0.05{\mu}m$ UF filtrate of the tap water and it was measured also with 20~30 cm water head difference which showed over 800 LMH at 30 cm water head difference. And Time-To-Filter (TTF) was performed by using $5{\mu}m$ filter paper to optimize coagulants and dosage which enhanced filtrate's turbidity and stabilized filtration flux. When the LPMF was operated with 30 cm gravity with very high dose of inorganic coagulants, the flux was maintained over 80 LMH with 93.5~99.5% turbidity removal. Especially, the filtration was maintained stably in the flux and about 97% of the recovery rate by instantaneous pressurized backwash with about 4 bar of the filtrate when the packing density was about 19%. But there was instability in filtration, since the TMP was continuously going up by inefficient backwash when the packing density was 43%.