• 제목/요약/키워드: PERFORMANCE MEASUREMENT

검색결과 7,002건 처리시간 0.034초

부분방전 측정에 의한 저압용 유도전동기의 절연성능 평가 (Evaluation on Insulation Performance of Low-voltage Induction Motors by Partial Discharge Measurement)

  • 박대원;최수연;최재성;길경석;이강원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1887-1891
    • /
    • 2008
  • In this paper, we dealt with a partial discharge (PD) measurement method that has been accepted as an effective and non-destructive technique to estimate insulation performance of low-voltage induction motors. The PD measurement system consists of a coupling network, a low noise amplifier, and associated electronics. A shielded box was used to reduce environmental noise. Frequency characteristic of the coupling network was estimated by a sinusoidal signal input, and the low cut-off frequency of the coupling network was 1 MHz (-3 dB). Also, we carried out a calibration test for the PD measurement system. Sensitivity of the system was of 84 m$V_{max}$/pC between stator winding and enclosure. In application test on a low-voltage three phase induction motor (5 HP), we could detect 88 pC at AC 800 $V_{max}$.

  • PDF

정밀 좌표측정용 머신비전 시스템의 광학적 해석에 관한 연구 (A Study on the optical aspects of machine vision based dimensional measurement system)

  • Lee, E.H.
    • 한국정밀공학회지
    • /
    • 제11권2호
    • /
    • pp.149-163
    • /
    • 1994
  • A novel method of dimensional measurement using machine vision, which is called Landmark Tracking System, has been developed. Its advantages come form tracking only the bright, standard shaped "landmarks" which are made from retroreflective sheets. In the design of the LTS, it is essential to know the relationship between optical parameters and their influence on system performance. Such optical parameters include the brightness of landmark image, the illumination system design, and the choice of imaging optics. And the performance of retroreflective material also plays important role in the LTS performances. Influences of such optical parameters on LTS's dimensional measurement characteristics are investigated, with respect to the retroreflective material, the imaging optics, and the illumination system. Measuremtn errors due to parameter variations are also analyzed. Experiments are performed with a LTS prototype. Retroreflective characteristics are verified, and the LTS's measurement performances are measured in the form of repeatability and accuracy. Experimental results shgow that the LTS has repeatability better than 1/30,000 of a field of view(30 degrees), and accuracy better tha 1/3,000 of a field fo view.d fo view.

  • PDF

열선을 이용한 혼합기체의 농도와 유량의 측정 (Measurement of Gas Concentration and flow Rate Using Hot Wire)

  • 김영한;최종정
    • 제어로봇시스템학회논문지
    • /
    • 제8권5호
    • /
    • pp.407-412
    • /
    • 2002
  • A measurement device for gas concentration and flow rate using hot wire is developed for the utilization in industrial applications. The device has two cells of measuring and reference, and a bridge circuit is installed to detect electric current through the hot wire in the cells. An amplification of the signal and conversion to digital output are conducted for the on-line measurement with a personal computer. The flow rate of air and carbon dioxide gas is separately measured for the performance examination of the device. Also, the concentration of air-carbon dioxide and carbon dioxide-argon mixtures is determined for the same evaluation. The outcome of the performance test indicates that the accuracy and stability of the device is satisfactory for the purpose of industrial applications.

건설기업 지적자산 측정모델에 관한 연구 (The Study on Intellectual Assets Measurement Model of Construction Corporation)

  • 손영찬;백종건;김재준
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2002년도 학술대회지
    • /
    • pp.257-260
    • /
    • 2002
  • 기업경영에 있어서 성과측정 시스템은 매우 중요하다. 측정이 있어야 문제점을 파악하고, 개선할 수 있기 때문이다. 기업의 유형자산은 재무제표나 손익계산서 등의 구체적인 금액으로 측정이 가능하나 기업의 무형자산은 지금까지 객관적이고 정량적인 측정방법을 볼 수 없었다. 이에 본 연구는 기업의 지적자산을 측정하는 모델을 통하여 건설기업의 무형자산(지적자산)의 크기를 객관적으로 정량화 시킬 수 있는 모델을 제시하고, 측정방법의 발전방향을 제시하고자 한다.

  • PDF

임펄스 측정잡음에 강인한 저가형 볼앤빔 시스템의 접촉식 볼 추적센서 개발 (Contact-Type Ball Tracking Sensor Robust to Impulsive Measurement Noises for Low-cost Ball-and-beam Systems)

  • 장주영;이자승;윤한솔;나원상
    • 제어로봇시스템학회논문지
    • /
    • 제20권11호
    • /
    • pp.1136-1141
    • /
    • 2014
  • This paper proposes a new contact type ball tracking sensor to improve the control performance of a low cost ball-and-beam system. It is well-known that the impulsive measurement noise contained in ball position measurement is one of the factors which severely degrades the ball-and-beam control performance. The impulsive ball position measurement noises often appear under the sporadical ball floating on the beam. This fact motivates us to devise a simple analog preprocessing circuit to determine whether the ball loses the contact or not. Once the abnormal ball position measurement is detected, the design problem of the ball tracking sensor can be cast into the typical state estimation problem with missing data. In order to tackle the real-time implementation issue, a steady-state Kalman filter is applied to the problem. Through the experimental results, the usefulness of the proposed scheme is demonstrated.

Voltage Measurement Accuracy Assessment System for Distribution Equipment of Smart Distribution Network

  • Cho, Jintae;Kwon, Seong-chul;Kim, Jae-Han;Won, Jong-Nam;Cho, Seong-Soo;Kim, Juyong
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1328-1334
    • /
    • 2015
  • A new system for evaluating the voltage management errors of distribution equipment is presented in this paper. The main concept of the new system is to use real distribution live-line voltage to evaluate and correct the voltage measurement data from distribution equipment. This new approach is suitable for a new Distribution Management System (DMS) which has been developed for a distribution power system due to the connection of distributed generation growth. The data from distribution equipment that is installed at distribution lines must be accurate for the performance of the DMS. The proposed system is expected to provide a solution for voltage measurement accuracy assessment for the reliable and efficient operation of the DMS. An experimental study on actual distribution equipment verifies that this voltage measurement accuracy assessment system can assess and calibrate the voltage measurement data from distribution equipment installed at the distribution line.

협대역 수중음향측정을 위한 신뢰도 기반의 측정정확도 분석 (Analysis of Measurement Accuracy Based on Confidences for Narrow-Band Underwater Acoustic Measurement)

  • 도경철;최재용;이용곤
    • 한국음향학회지
    • /
    • 제19권4호
    • /
    • pp.16-22
    • /
    • 2000
  • 본 연구에서는 오차분산을 명확하게 표현하지 못하는 협대역 수중음향 측정체계의 측정성능 및 운용성을 설계 단계에서 사전 예측할 목적으로, 신호대잡음비에 따른 신뢰도 기반의 협대역 측정정확도 예측 기준을 제안한다. 제안 기준에서 신호의 평균과 분산은 신호의 샘플 개수와 신호대잡음비에 의해 표현된다. 본 논문에서는 편향된 환경에서 수중음향을 분석하는 경우와 배경소음을 사전 예측하여 측정음향에서 제거시키는 경우에 대하여 협대역 수중음향 측정성능 예측을 제안 기준에 의해 시뮬레이션하고 그 결과를 고찰한다.

  • PDF

Adaptive Selective Compressive Sensing based Signal Acquisition Oriented toward Strong Signal Noise Scene

  • Wen, Fangqing;Zhang, Gong;Ben, De
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권9호
    • /
    • pp.3559-3571
    • /
    • 2015
  • This paper addresses the problem of signal acquisition with a sparse representation in a given orthonormal basis using fewer noisy measurements. The authors formulate the problem statement for randomly measuring with strong signal noise. The impact of white Gaussian signals noise on the recovery performance is analyzed to provide a theoretical basis for the reasonable design of the measurement matrix. With the idea that the measurement matrix can be adapted for noise suppression in the adaptive CS system, an adapted selective compressive sensing (ASCS) scheme is proposed whose measurement matrix can be updated according to the noise information fed back by the processing center. In terms of objective recovery quality, failure rate and mean-square error (MSE), a comparison is made with some nonadaptive methods and existing CS measurement approaches. Extensive numerical experiments show that the proposed scheme has better noise suppression performance and improves the support recovery of sparse signal. The proposed scheme should have a great potential and bright prospect of broadband signals such as biological signal measurement and radar signal detection.

WIRELESS SENSOR NETWORK BASED BRIDGE MANAGEMENT SYSTEM FOR INFRASTRUCTURE ASSET MANAGEMENT

  • Jung-Yeol Kim;Myung-Jin Chae;Giu Lee;Jae-Woo Park;Moon-Young Cho
    • 국제학술발표논문집
    • /
    • The 3th International Conference on Construction Engineering and Project Management
    • /
    • pp.1324-1327
    • /
    • 2009
  • Social infrastructure is the basis of public welfare and should be recognized and managed as important assets. Bridge is one of the most important infrastructures to be managed systematically because the impact of the failure is critical. It is essential to monitor the performance of bridges in order to manage them as an asset. But current analytical methods such as predictive modeling and structural analysis are very complicated and difficult to use in practice. To apply these methods, structural and material condition data collection should be performed in each element of bridge. But it is difficult to collect these detailed data in large numbers and various kinds of bridges. Therefore, it is necessary to collect data of major measurement items and predict the life of bridges roughly with advanced information technologies. When certain measurement items reach predefined limits in the monitoring bridges, precise performance measurement will be done by detailed site measurement. This paper describes the selection of major measurement items that can represent the tendency of bridge life and introduces automated bridge data collection test-bed using wireless sensor network technology. The following will be major parts of this paper: 1) Examining the features of conventional bridge management system and data collection method 2) Mileage concept as a bridge life indicator and measuring method of the indicator 3) Test-bed of automated and real-time based bridge life indicator monitoring system using wireless sensor network

  • PDF

BSC/DEA를 활용한 기업 연구개발 프로젝트 성과평가 (Performance Evaluation of Private R&D Projects using BSC/DEA)

  • 전익진;이학연
    • 경영과학
    • /
    • 제34권2호
    • /
    • pp.67-83
    • /
    • 2017
  • This paper proposes a R&D project performance measurement model for private firms combining balanced scorecard (BSC) and data envelopment analysis (DEA). The efficiency of R&D projects is measured in terms of each of the three perspectives of BSC by using DEA : the internal process perspective (DEA-P), the customer perspective (DEA-C), and the financial perspective (DEA-F). The performance indicators of the three perspectives of BSC are considered as outputs of the corresponding DEA models. To provide strategic implications for R&D planning, we also propose the R&D project performance matrices composed of two different types of efficiency dimensions. The proposed model is expected to be fruitfully utilized for R&D performance measurement of private firms.