• Title/Summary/Keyword: PEC cylinder

Search Result 2, Processing Time 0.015 seconds

Convergence rates of the TE EFIE scattering solutions from a PEC cylinder (PEC 원통을 TE EFIE 방법으로 산란 해석한 결과의 수렴율)

  • Hong, Chinsoo;Bae, HyungChul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.7189-7195
    • /
    • 2015
  • The method of moments (MoM) is implemented to simulate scattering from a PEC (perfectly electric conductor) cylinder in the TE(transversw electric) EFIE (Electric Field Integral Equation) approach. The procedure expresses the singularity integral and the hypersingularity integral in terms of an analytic function and employs a singularity isolation process coupled with numerical technique along the discretized segment to evaluate the self terms. It is known that, in the MoM technique, the choice of base functions and test functions is very important for the accuracy and convergence of the numerical analysis. Thus, in this paper, three conditions, obtained from the combination of basis functions and test functions, are adopted to get the induced currents on the PEC surface. These currents are compared to the analytical one in the relative rms current error to get the condition that shows fast convergence rate. The fast order of convergence of the current error, 2.528, is obtained under the combination of pulse basis function/delta test function.

The Lowest Dose for CT Attenuation Correction in PET/CT

  • Kang, Byung-Sam;Son, Jin-Hyun;Park, Hoon-Hee;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.3
    • /
    • pp.111-115
    • /
    • 2011
  • PET/CT(Positron Emission Tomography/Computed Tomography) is an examination combining morphological and functional information in one examination. The purpose of this study is to see the lowest CT dose for attenuation correction in the PET/CT maintaining good image quality when considering CT scan dose to the patients. We injected $^{18}F$-FDG and water into the cylinder shaped phantom, and obtained emission images for 3 mins and transmission images(140 kVp, 8 sec, 10~200 mA for transmission images), and reconstructed the images to PET/CT images with Iterative method. Data(Maximum, Minimum, Average, Standard Deviation) were obtained by drawing a circular ROI(Region Of Interest) on each sphere in each image set with Image J program. And then described SD according to the CT and PEC/CT images as graphes. Through the graphes, we got the relationships of mA and quality of images. SDs according to CT graph were 16.25 at 10 mA, 7.26 at 50 mA, 5.5 at 100 mA, 4.29 at 150 mA, and 3.83 at 200 mA, i.e. the higer mA, the better image quality was presented. SDs according to PET/CT graph were 1823.2 at 10 mA, 1825.1 at 50 mA, 1828.4 at 100 mA, 1813.8 at 150 mA, and 1811.3 at 200 mA. Calculated SDs at PET/CT images were maintained. This means images quality is maintained having nothing to do with mA of high and low.

  • PDF