• Title/Summary/Keyword: PDP cell

Search Result 179, Processing Time 0.032 seconds

Measurement of the excited Xe atoms density of matastable state$(1S_5)$ under various binary gas mixtures(Ne-Xe) by Laser Absorption Spectroscopy.

  • Lee, Jun-Ho;OH, P.Y.;Moon, M.W.;Ko, B.D.;Jeong, J.M.;Lee, H.J.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1218-1220
    • /
    • 2005
  • We have developed laser absorption spectroscopy system for the measurement of excited Xe atoms in micro-discharged AC-PDP plasma. In this study, we have measured the absorption signals for the $1S_5$ xenon metastable state in the PDP cell with the various gas mixtures of Ne-Xe(1%), Ne-Xe(4%) and Ne-Xe(10%) under fixed gas pressure of 350 Torr and the eletrode gap distance of 50um. It is found that the maximum excited xenon densities are $1.2^{\ast}10^{12}\;cm^{-3}$, $1.8^{\ast}10^{12}\;cm^{-3}$ and $2.7^{\ast}10^{12}cm^{-3}$ for gas mixtures of Ne-Xe(1%), Ne-Xe(4%) and Ne-Xe(10%) respectively, in this experiment.

  • PDF

Spatial Measurement of Plasma Temperature & Density in a microdischarge AC-PDP cell

  • 김진구
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.231-231
    • /
    • 1999
  • PDP(Plasma Display Panel)는 21세기 디스플레이 시장을 대체할 차세대 디스플레이 장치로서 넓은 시야각, 얇고, 가볍고, 메모리기능이 있다는 여러 가지 장점들을 가지고 있지만 현재 고휘도, 고효율, 저소비전력 등의 문제점들을 해결하여야 한다. 이러한 문제점들의 해결을 위해서는 명확한 미세방전 PDP 플라즈마에 대한 정확한 진단 및 해석이 필요하다. 따라서 본 연구에서는 미세 면방전 AC-PDP 플라즈마의 기초 변수들 (플라즈마 밀도 & 온도, 플라즈마 뜬 전위, 플라즈마 전위 등의 측정을 통해 고휘도, 고효율 PDP를 위한 최적의 방전환경을 알아내는 데 있다. 일반적으로 전자의 밀도는 방전전류에 비례하는 관계를 보인다. 전류에 대해 방전전압이 일정하다면 전자밀도가 커짐에 따라서 휘도는 포화되며 상대적으로 휘도와 전류의 비로 표시되는 발광효율은 감소하게 된다. 반면 전자밀도가 상당히 작다면 휘도는 전자밀도에 비례하고 효율은 최대값을 보인다. 따라서 미세구조 PDP에서 휘도와 발광효율, 양쪽에 부합하는 최적의 방전환경을 플라즈마 전자밀도와 온도의 측정을 통해서 해석하는 것이 필요하다. 본 실험에서는 방전기체의 종류와 Ne+Xe 방전기체의 조성비에 따른 플라즈마 밀도, 온도의 공간적인 분포특성을 진단하기 위해서 초미세 랑뮈에 탐침(지름: 수 $mu extrm{m}$)을 제작하였다. 제작된 초미세 탐침을 컴퓨터로 제어되는 스텝핑모터를 장착한 정밀 X, Y, Z stage에 부착하여서 수 $\mu\textrm{m}$간격의 탐침 삽입위치에 따라서 미세면방전 AC-PDP의 플라즈마 밀도 및 온도분포 특성을 진단하였다. PDP 방전공간에 초미세 랑뮈에 탐침을 삽입해서 -200~+200V의 바이어스 전압을 가해준다. 음의 바이어스 전압구간에서 이온 포화전류를 얻어내어 여기서 플라즈마 이온 밀도를 측정하고 양의 바이어스 전압구간에서 플라즈마 전자온도를 측정하면 미세면방전 AC-PDP 플라즈마의 기초 진단이 가능하다.

  • PDF

Measurement of excited Xe atoms density in accordance with various barrier ribs in AC-PDP by laser absorption spectroscopy

  • Jeong, Se-Hoon;Oh, P.Y.;Hong, Y.J.;Lee, S.B.;Moon, M.W.;Song, K.B.;Lee, H.J.;Yoo, N.L.;Son, C.G.;Han, Y.G.;Jeong, S.J.;Kim, J.H.;Park, E.Y.;Choi, Eun-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.949-952
    • /
    • 2006
  • We have measured the excited Xe atoms density in the $1s_5$ metastable states by laser absorption spectroscopy in accordance with various barrier ribs. In this experiment, the average density of one cell in the panel with stripe barrier rib has been measured to be $1.8{\times}10^{12}cm^{-3}$. The panel with close type barrier rib has been measured to be $5.1{\times}10^{12}cm^{-3}$.

  • PDF

Measurement of Spatiotemporal Distribution for the Density of Excited Xe Atoms in the 1s5 in Accordance with Various ITO-shapes in Ac-PDP (교류형 플라즈마 평판 표시장치(AC-PDP)에서 ITO 전극 구조에 따른 Xe 여기종의 시공간 밀도 분포 연구)

  • Cho, S.H.;Hong, Y.J.;Son, C.G.;Han, Y.G.;Jeong, Y.H.;Gwon, G.C.;Hong, B.H.;Cho, G.S.;Choi, E.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.1
    • /
    • pp.54-59
    • /
    • 2009
  • We have measured the spatiotemporal behavior for the density of excited Xe atoms in the $1s_5$ metastable states by laser absorption spectroscopy in accordance with various shapes of ITO electrode. The maximum density of excited Xe atoms in the Is5 state in a discharge cell for fish-boned, T-shaped and squared ITO electrodes has been measured to be $3.01{\times}10^{13}\;cm^{-3}$, $2.66{\times}10^{13}\;cm^{-3}$ and $2.06{\times}10^{13}\;cm^{-3}$, respectively. Throughout this experiment, we could understand the influence of the shapes of ITO electrode of micro discharge cell on the high efficiency of AC-PDPs.

Discharge Characteristic Analysis with a Ramp Reset Waveform Using 2-Dimensional Simulation in the PDP (AC PDP에서 2차원 수치해석을 이용한 Ramp Reset 구동파형에 따른 방전 특성 분석)

  • Park, Suk-Jae;Choi, Hoon Young;Seo, Jeong-Hyun;Lee, Seok-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.192-194
    • /
    • 2003
  • In this paper, we present a 2-Dimensional simulation model of the discharge in an ac plasma display panel cell. Therefore, we study a ramp reset waveform in an ac plasma display panel discharge cell using 2-Dimensional simulation. Finally We research a connection between priming particles' density and stability.

  • PDF

High Xe-content PDP

  • Oversluizen, G.;Dekker, T.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.55-58
    • /
    • 2004
  • High Xe-content PDP characteristics are discussed. A high efficacy, up to 5 lm/W for a 50% Xe in Ne gas mixture, is realized in 4-inch color PDP test panel designs with low cost stripe-type barrier rib structures, that are powder blasted in soda lime glass. Furthermore, for a high Xe-content a high luminance can be obtained with a relatively small electrode area. Therefore the inter cell gap and the driving margin can be increased in a stripe-type barrier rib structure. Finally, for a high Xe-content the panel lifetime increases, due to increasing luminance and firing voltage stability. Clearly, these findings may direct the design development for next generation PDPs towards a high Xe-content

  • PDF

Discharge Properties of an AC-Plasma Display Panel

  • Sungkyoo Lim
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.5 no.1
    • /
    • pp.1-6
    • /
    • 1998
  • Two kinds of the ac-plasma display panel (PDP) with the comb type and the matrix type electrodes were fabricated. The discharge properties were studied as a function of as species (Ne and Ne+He+Xe) and its pressure. The firing voltages (Vf) of the PDP with comb type electrodes were 159 V and 195 V under pure Ne and ne+He+Xe(68:30:2) gas mixture respectively. In case of PDP cell with the matrix type electrodes the Vf was increased to 200 V for pure Ne and 240 V for Ne+He+Xe gas mixture under the same gas pressure(300 mbar).

Studies about Visible Light Distribution in PDP Cells with 3-dimesional Optical Code

  • Eom, Chul-Whan;Kang, Jung-Won
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.582-584
    • /
    • 2007
  • In order to improve the accuracy of simulated results, new UV source was designed. Previously the optical simulation was performed with the symmetric planar UV source. To design new UV source, UV distribution from the plasma fluid code was implanted to the 3-dimensional optical code to generate the visible light distribution. The results from planar UV source and new UV source were compared with the ICCD (Intensified CCD) image in real PDP cell and analyzed the variation of geometries and optical properties.

  • PDF

Comparison of the fluid simulation with experimental data of excited Xe species density in PDP cell

  • Yang, Sung-Soo;Ko, Sang-Woo;Kim, Hyun-Chul;Mukherjee, Sudeshna;Lee, Jae-Koo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.739-742
    • /
    • 2003
  • We have compared 2-D and 3-D fluid simulation results of alternating current plasma display panel (AC-PDP) cell with experimentally measured two kinds of excited Xe species $Xe^{\ast}(^{3}P_{1})$ and $Xe^{\ast}(^{3}P_{2})$ characteristics. Although direct experimental access and diagnostics of the discharge in a PDP cell is problematic due to the small cell size, some of experimental technologies have made it possible to diagnose the behavior of excited Xe species [1, 2]. The simulation shows the similar characteristics to the experimental results in the excited Xe species density distribution and the number of excited Xe atoms in anode and cathode region. In certain cases, we obtained the arch-shaped discharge path between two sustain electrodes due to the additional pulse applied to address electrode analogous to experiment. This long path discharge induced higher luminous and discharge efficiency compared to the standard case.

  • PDF

Real time Image Processor for Reproduction of Gray Levels in Dark Areas on Plasma Display Panel (PDP) (플라즈마 디스플레이 패널의 어두운 영역에서의 계조 재현을 위한 실시간 영상처리기)

  • Lee, Chang-Hun;Park, Seung-Ho;Gang, Jin-Gu;Kim, Chun-U
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.1
    • /
    • pp.46-54
    • /
    • 2002
  • Plasma Display Panel (PDP) is required to be both the determination of white point of each gray level and the inverse gamma correction since no-balanced RGB cell and linear property of PDP, respectively. However, these two methods cause degradation of grey level representation and undesirable false contour in the dark areas on PDP. In this paper, we implemented real time image processor of the proposed error diffusion algorithm and unsharp masking operation to protect the blurring image caused by the error diffusion. Experimental results showed drastic improvements of gray level representation and reduction of undesirable false contour.