• Title/Summary/Keyword: PDP cell

Search Result 179, Processing Time 0.053 seconds

The Optimization of AC-PDP Cell by 2D Simulations

  • Kim, Woong;Y.K. Shin;C.H. Shon;J.H. Kang;Park, J.S.;Lee, J.K.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.227-227
    • /
    • 1999
  • Plasma display panel(PDP) is a leading technology for large-area flat panel displays. A current issue in operating the PDP cell is that the efficiency of the PDP cell is very low. To increase the efficiency of the PDP cell, the visible light needs to be maximized and the power consumption minimized. Since the excited xenons are related to the production of the visible light, it is important to optimize the cell geometry and the gas composition that produce the excited xenons more efficiently. A 2D-fluid code (FL2P) is developed and used to simulate the plasma dynamics and the radiation transport in the PDP cell. The cell is optimized with the code for various operating conditions and cell dimensions such as the voltage pulse, electrode length, electrode spacing, gap size, dielectric constant, gas mixture ratio, pressure, and pulse duration.

  • PDF

3-D Simulation of T-Shaped Electrode and Comparison of Results with Experiments

  • Shin, Yeong-Kyo;Hwang, Tae-Su;Kang, Seok-Dong;Park, Hun-Gun;Ryu, Jae-Hwa;Kim, Hyun-Chul;Shin, Seong-Won;Lee, Jae-Koo
    • Journal of Information Display
    • /
    • v.3 no.2
    • /
    • pp.13-18
    • /
    • 2002
  • Numerical simulation is one of the most useful tools to study gas discharge phenomena that occur in alternating current plasma display panel (AC-PDP) cell. Most PDP cell simulations have been performed for two-dimensional cell, is cross-section along the address electrode. We developed a three-dimensional PDP simulator and applied it to a T-shaped electrode cell in order to show the effects of sustain electrode shape that cannot be included in two-dimensional simulation. The dependence of power consumption on electrode shape and area in the simulation showed the same trend as experiment.

Formation of PDP cell structure using Nd:YAG laser beam (Nd:YAG 레이저빔에 의한 PDP 방전셀의 구조 형성)

  • Ahn, Min-Young;Lee, Kyoung-Cheol;Lee, Hong-Kyu;Lee, Cheon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.129-132
    • /
    • 2000
  • The PDP(Plasma Display Panel) barrier rib material on the glass substrate was patterned for fabrication of the PDP cell using Nd:YAG laser(1064 nm) which can generate the second(532 nm) and forth(266 nm) harmonic wave by HGM(harmonic generation modules). At a scan speed of 20 ${\mu}m/s$ with the second harmonic wave(532 nm) of Nd:YAG laser, the etching threshold laser fluence of the PDP material was 6.5 $mJ/cm^2$ and a sample(thickness = 180 ${\mu}m$) on the glass substrate was removed clearly at a laser fluence of 19.5 $mJ/cm^2$. In order to increase the throughput of the fabrication we divided a single-beam into multi-beams by using a metal mask between the sample and the focusing lens. As a result, 10 lines of PDP cell were formed by one laser beam scanning at a scan speed of 200 ${\mu}m/s$ and a laser fluence of 2.86 $J/cm^2$.

  • PDF

The Analysis for PDP Discharge as a Parameter of Electrode Structure by 3-Dimensional Light Emission Measurement (3차원 광 측정을 통한 PDP의 전극 구조별 방전 분석)

  • Woo, Seok-Gyun;Choi, Hoon-Young;Lee, Seok-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.4
    • /
    • pp.190-196
    • /
    • 2001
  • We measured 3-dimensional images of the light emitted from plasma display panel(PDP) by using newly proposed scanned point detecting method(SPDM). The SPDM has the point detector with pinhole. The light emitted from PDP cell at the in-focus position can pass through the pinhole and be collected by detector. On the contrary, the light emitted from PDP cell at the out-of-focus positions is focused on the front of or the behind of the pinhole. We could analyze the characteristic of 3-dimensional light emission distribution by SPDM. From 3-dimensional measurement of 828[nm], the efficient design of PDP cell, the importance of opening ration, and the relations between BUS electrode position and discharge intensity are obtained. Also, the relationship between discharge characteristics and sustain electrode structures in AC-PDP are studied by measuring luminance, current, and discharge voltage.

  • PDF

The 3-Dimensional Analysis for AC-PDP Discharge by Light Emission Measurement (AC-PDP의 3차원 광 측정을 통한 방전 분석)

  • 우석균;최훈영;이승걸;이석현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.577-580
    • /
    • 2000
  • We measured 3-dimensional images of the light emitted from plasma display panel(PDP) by using newly proposed scanned point detecting method(SPDM). The SPDM has the point detector with pinhole. The light emitted from PDP cell at the in-focus position can pass through the pinhole and be collected by detector. On the contrary, the light emitted from PDP cell at the out-of-focus positions is focused on the front of or the behind of the pinhole. We could analyze the characteristic of 3-dimensional light emission distribution by SPDM. From 3-dimensional measurement of 828nm, we found that the efficient design of PDP cell, the importance of opening ratio, and the relations between BUS electrode position and discharge intensity are obtained.

  • PDF

Influence of constraint MgO deposition onto phosphors on luminance properties in AC Plasma Display Panels

  • Jeoung, Jin-Man;OH, P.Y.;Moon, M.W.;Lee, J.H.;Jeong, J.E.;Lee, H.J.;Han, Y.K.;Lee, S.B.;Jeong, S.H.;Yoo, C.K.;Yoo, N.R.;Choi, E.H.;Ko, B.D.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1215-1217
    • /
    • 2005
  • One of the important problems in recent AC-PDP technology is the image sticking. In this research, we have investigated the PDP cell with constraint deposition MgO on phosphor, the electrical and optical properties in the PDP cell were examined. Also, we have investigated the correlation with image sticking and degraded MgO protective layer, phosphor in AC-PDP. As a result, we measured the secondary electron emission coefficient ${\gamma}$, discharge characteristics and Brightness for the constraint degraded phosphor are compared with those of nondegraded phosphor.

  • PDF

LGE's Strategy for PDP TV

  • Kim, Jae-Sung;Lee, Sung-Hyun;Ahn, Sung-Yong;Ahn, Young-Joon;Ryu, Jae-Hwa;Yoon, Kwang-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.71-74
    • /
    • 2005
  • There have been various efforts to achieve a better PDP TV, which have low power consumption, high image quality and low price. As the results, the power consumption of LG's new 42 inch HD PDP could be lower than 42 inch LCD under the general movie display load condition. And the address discharge time lag of ${\sim}1\;{\mu}s$ for 42 and 50 inch XGA single scan by which the cost can be reduced and image quality can be improved was achieved by using new MgO material and driving waveform. In addition, we have suggested TCA (Triangular Color pixel Arrangement) cell structure for realizing the full HDTV of 60inch diagonal size, which has $1920{\times}1080$ resolution. The luminous efficiency of the suggested TCA structure has been increased about 40% compared with that of the conventional cell structure.

  • PDF

Optimization on the Characteristics of DC Discharge Cell in the AND Gate PDPs (ADN Gate PDP의 DC 방전셀 방전특성 최적화)

  • Ryeom, Jeong-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.34-39
    • /
    • 2004
  • This research investigated the influence on the 4 cell of DC discharge on the side of the discharge characteristic. This DC discharge cells are that composes AND gate of AND gate PDP newly proposed. As for the discharge starting voltage of this discharge cell of 4 pieces, it has been understood that there is deeply a relation up to the space charge generated from the discharge of adjoining discharge cell through the experiment. The discharge voltages which had become each discharge cell optimizations from the experiment result were decided. Moreover, the width of the margin of two AND input voltages is wide and the AND function occurs clearly. However, it has been qualitatively understood that it is difficult enough to obtain the operation margin of the DC priming discharge used to address discharge of PDP.

Electro-Optical characteristics with dielectric thickness of AC-PDP

  • Jung, K.B.;Choi, J.H.;Kim, S.B.;Jung, Y.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.768-770
    • /
    • 2003
  • In AC PDP, since charges generated by gas discharge are accumulated on the dielectric. The dielectric is a major factor to determine cell capacitance and its memory effect is a play an important role in PDP driving. In this experiment, we have investigated the electro-optical characteristics with dielectric thickness and we have analyzed wall charge and wall voltage by Q-V energy diagram. The dielectric thickness was varied from 20 um to 50 um. As results, according to the dielectric thickness increase,cell capacitance and power consumption is reduced.

  • PDF

광학 시뮬레이션을 통한 PDP cell 구조의 최적화

  • Jeong Seon-Uk;Choe Hye-Rim;Gang Jeong-Won
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2006.05a
    • /
    • pp.160-163
    • /
    • 2006
  • 고정세 PDP에서 방전 cell의 휘도와 효율을 증가시키기 위해서는 cell을 구성하고 있는 layer의 광학 성질과 구조를 고려한 설계가 필요하다. 3-dimensional optical code를 사용한 새로운 접근 방법은 다양한 geometry의 구성, 광학 성질의 적용의 용이함, 정확한 분석 데이터 등의 장점을 활용하여 PDP cell의 구조와 재료 변화에 따른 광 패턴과 조도 ($1m/mm^2$)를 관찰함으로써 향상된 휘도와 효율 특성을 갖는 cell 구조를 설계할 수 있게 된다. 본 논문은 PDP 상판을 구성하는 ITO, bus electrode, dielectric layer의 구조와 광학특성을 변화 시키고, 현재 양산 모델에 적용중인 다양한 상판 구조를 optical code를 활용하여 연산하여 도출된 결과를 비교하였다.

  • PDF