• Title/Summary/Keyword: PDP(Plasma Display)

Search Result 684, Processing Time 0.039 seconds

Composition and Properties of Substrate Glasses for Plasma Display Panel (Plasma Display Panel용 기판 유리의 조성과 성질)

  • Kim, Ki-Dong;Jung, Woo-Man;Kwon, Sung-Ku;Choi, Se-Young
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.5 s.288
    • /
    • pp.293-298
    • /
    • 2006
  • For substrate glass applied to PDP (Plasma Display Panel), it has been developed many glass compositions that have to not only meet the specifications of PDP but also satisfy the float process as production technology. In the present work several compositions with no deformation at PDP processing temperature and thermal expansion coefficient of $83{\sim}9{\times}10^{-7}/K$ were designed. Based on viscosity at high temperature and liquidus temperature for those compositions, three candidate compositions named T-2, T-4, T-6 were selected finally. It was examined additionally that thermal shrinkage at PDP processing temperature and visible transmittance. The properties of T-series were compared with those of commercial glasses and discussed from the view point of PDP device and glass production.

Design and Implementation of an Automated Visual Inspection System of PDP Frames (PDP 프레임 자동시각검사 시스템 설계 및 구현)

  • Park, Byung-Joon;Hahn, Kwang-Soo;Shin, Eun-Seok
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.4
    • /
    • pp.512-525
    • /
    • 2010
  • A PDP(Plasma Display Panel) Frame is critical part of PDP and also produces couple hundred thousand every month. In the process of mass production, product inspection is very important process. Also to increase the reliance, inspection each part and every final product is asked quite often. Purpose of this paper is to use computer vision system to inspect the PDP parts which is Automated visual process inspection. This paper contains the system design for inspecting defects of hole, tab, stud, rivet of PDP Frame. The system also can inspect various kinds of PDP frames. Quick and accurate 100% inspection of all shapes can improve the manufacturing productivity. Inspection results can be stored in a database and analyzed to find the cause of defects. After applying the system to the industry, the result shows the possibility of fast and accuracy of the inspection.

Measurement of ion-induced secondary electron emission coefficient for MgO thin film with $O_{2}$ plasma treatment

  • Jeong, H.S.;Oh, J.S.;Lim, J.Y.;Cho, J.W.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.802-805
    • /
    • 2003
  • The ion-induced secondary electron emission coefficient ${\gamma}$ for MgO thin film with $O_{2}$ plasma treatment has been investigated by ${\gamma}$-FIB (focused ion beam) system. The MgO thin film deposited from sintered material with $O_2$ plasma treatment is found to have higher ${\gamma}$ than that without $O_{2}$ plasma treatment. The energy of $Ne^{+}$ ions used has been ranged from 100eV to 200eV throughout this experiment. It is found that the highest secondary electron emission coefficient ${\gamma}$ has been achieved for 10 minutes of $O_{2}$ plasma treatment.

  • PDF

Influence of the degradation of MgO protective layer on the Surface profiles and discharge characteristics in AC-PDP.

  • Lee, Soo-Beom;Jeoung, J.M.;Ko, B.D.;Oh, P.Y.;Moon, M.W.;Lee, J.H.;Lim, J.E.;Lee, H.J.;Han, Y.G.;Yoo, N.L.;Jeoung, S.H.;Son, C.G.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1207-1210
    • /
    • 2005
  • The MgO protective layer provides protection from the discharge, lowers the discharge voltage and prolongs the AC-PDP lifetime. We have investigated the characteristics of degradation of MgO protective layer, which correlates to the image-sticking[1] and the lifetime in AC-PDP. The degraded MgO have been changed the surface morphology of MgO. It was found that panel lifetime depended on degradation of MgO protective.

  • PDF

Measurement of excited Xe atoms density in accordance with various barrier ribs in AC-PDP by laser absorption spectroscopy

  • Jeong, Se-Hoon;Oh, P.Y.;Hong, Y.J.;Lee, S.B.;Moon, M.W.;Song, K.B.;Lee, H.J.;Yoo, N.L.;Son, C.G.;Han, Y.G.;Jeong, S.J.;Kim, J.H.;Park, E.Y.;Choi, Eun-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.949-952
    • /
    • 2006
  • We have measured the excited Xe atoms density in the $1s_5$ metastable states by laser absorption spectroscopy in accordance with various barrier ribs. In this experiment, the average density of one cell in the panel with stripe barrier rib has been measured to be $1.8{\times}10^{12}cm^{-3}$. The panel with close type barrier rib has been measured to be $5.1{\times}10^{12}cm^{-3}$.

  • PDF

Thermal characteristics variation of PDP in compliance with dielectric loss

  • Lee, Tae-Ho;Jung, Jae-Chul;Lee, Sang-Kuk;Kim, Joong-Kyun;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.265-268
    • /
    • 2009
  • The discharge condition of Plasma display panel(PDP) changes as the display time increases. Imaginary part of permittivity of dielectric material which is related to dielectric loss has been often neglected because of relatively small value compare to that of the real part. The thermal characteristics of PDPs with two different dielectrics has been studied and compared.

  • PDF

Influences of degradation in MgO protective layer and phosphors on ion-induced secondary electron emission coefficient and static margins in alternating current plasma display panels

  • Jeong, H.S.;Lim, J.E.;Park, W.B.;Jung, K.B.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.518-521
    • /
    • 2004
  • The degradation characteristics of MgO protective layer and phosphors have been investigated in terms of the ion-induced secondary electron emission coefficient ${\gamma}$ and static margin of discharge voltages, respectively, in this experiment. The ion-induced secondary electron emission coefficients ${\gamma}$ for the degraded MgO protective layer and phosphors have been studied by ${\gamma}$ -focused ion beam system. The energy of Ne+ ions used is from 80 eV to 200 eV in this experiment. The degraded MgO and phosphor layers are found to have higher ${\gamma}$ than that of normal ones without degradations or aged one. Also, the static margin of discharge voltages for test panels with degraded MgO protective layer and phosphors been found to be seriously decreased in comparison with those of normal ones without degradations.

  • PDF

Surface Discharge in Various Electrode Geometries

  • Joh, Dai-Geun;Kim, Hyun-Sook;Gill, Do-Hyun;Kim, Young-Goun;Choi, Eun-Ha;Cho, Guang-Sup
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.111-112
    • /
    • 2000
  • The breakdown characteristics of surface discharge investigated experimentally agree well with the analytic results of previous reports [1-3] in various electrode geometries. Additionally, we find that the electrode geometry effects on the firing voltage can be understood with the ionization probability relating to the number of priming particles. We have also observed the shape of surface discharge and the surface striations in the gap geometry with the pressure, the applied voltage, and the driving frequency.

  • PDF

Measurement of the excited Xe atoms density of matastable state$(1S_5)$ under various binary gas mixtures(Ne-Xe) by Laser Absorption Spectroscopy.

  • Lee, Jun-Ho;OH, P.Y.;Moon, M.W.;Ko, B.D.;Jeong, J.M.;Lee, H.J.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1218-1220
    • /
    • 2005
  • We have developed laser absorption spectroscopy system for the measurement of excited Xe atoms in micro-discharged AC-PDP plasma. In this study, we have measured the absorption signals for the $1S_5$ xenon metastable state in the PDP cell with the various gas mixtures of Ne-Xe(1%), Ne-Xe(4%) and Ne-Xe(10%) under fixed gas pressure of 350 Torr and the eletrode gap distance of 50um. It is found that the maximum excited xenon densities are $1.2^{\ast}10^{12}\;cm^{-3}$, $1.8^{\ast}10^{12}\;cm^{-3}$ and $2.7^{\ast}10^{12}cm^{-3}$ for gas mixtures of Ne-Xe(1%), Ne-Xe(4%) and Ne-Xe(10%) respectively, in this experiment.

  • PDF

High Efficient Energy Recovery Circuit for AC Plasma Display Panel (AC Plasma Display Panel 구동 장치의 고효율 전력 회수 회로에 관한 연구)

  • 윤원식;강필순;김철우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.481-488
    • /
    • 2001
  • The sustaining driver for color AC Plasma Display Panel should provide alternating high voltage pulses and recover the energy discharged from the intrinsic capacitance between the scanning and sustaining electrodes inside the panel In this paper a novel efficient energy recovery circuit employing boost-up function is proposed to achieve a faster rise-time and in order to obtain a stable sustain voltage The principle of operation. features simulated results and experiment results are illustrated and verified on a 7.5-inch-panel with 200[kHz]switch frequency.

  • PDF