• Title/Summary/Keyword: PDM-117

Search Result 2, Processing Time 0.021 seconds

Utilization-Focused Reduction of Radiation Exposure with XCP-DS FIT Sensor Holder by Measuring Dose of Dental X-ray Generator (구내 방사선발생기의 선량 분포측정을 통한 필름유지기구(XCP-DS FIT)의 피폭선량감소에 대한 유용성)

  • Lee, Kyung Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.465-471
    • /
    • 2012
  • In this study, three dimensional X-ray dose distribution from dental X-ray generator system was measured by ALOKA PDM-117 dosimeter. The X-ray dose distribution will be change with XCP-DS FIT in oral shot, because the distance between X-ray generator and the dosimeter. The X-ray dose change affects on patient exposure and radiograph image quality. Therefore, it is important to obtain relation between the X-ray dose and the distance. The X-ray dose at the central position was decreased with increasing the distance. Furthermore, the dose at the edge of the X-ray flux was increased with increasing the distance. The increased dose affects on the patient radiation exposure. The present results will provide for good dental radiograph image and reducing radiation over-exposure on patient.

Study on the Exposure Field of Head and Neck with Measurement of X-ray dose Distribution for Dental Panoramic X-ray System (치과 파노라마 장치의 X선 공간선량분포 측정을 통한 두경부 피폭영역 조사에 대한 연구)

  • Oh, Yoonjin;Hong, Girang;Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.17-21
    • /
    • 2015
  • Recently, As people's interest in the health of teeth is increased in the medical field changed into aging society, the number of times for the radiological diagnosis is increased. It can be said that the radiation exposure dose of Korean population is increased. It is also growing concern about radiation exposure. Therefore, the basic data for the dental panoramic X-ray system, its investigation and measuring the radiation dose is needed. In this study, we used ALOKA PDM-117 dosimeter and estimated a two-dimensional dose distribution of the dental panoramic X-ray system (VATEC Pax-400). Dose evaluation about the distribution is confirmed from the point of radiation exposure of a patient. Dose distribution of the dental panoramic X-ray system irradiated chin and the facial region to high dose as well as the parts of teeth. It was founded that the eye lens which are sensitive to radiation are exposed to unnecessary radiation, considering the effect of scattered radiation. The results of this study will be used more accurate dose assessment in a variety of object size and location of measuring dose.